Objective Assessment of Listening Effort: Coregistration of Pupillometry and EEG

Open access

Abstract

Listening to speech in noise is effortful, particularly for people with hearing impairment. While it is known that effort is related to a complex interplay between bottom-up and top-down processes, the cognitive and neurophysiological mechanisms contributing to effortful listening remain unknown. Therefore, a reliable physiological measure to assess effort remains elusive. This study aimed to determine whether pupil dilation and alpha power change, two physiological measures suggested to index listening effort, assess similar processes. Listening effort was manipulated by parametrically varying spectral resolution (16- and 6-channel noise vocoding) and speech reception thresholds (SRT; 50% and 80%) while 19 young, normal-hearing adults performed a speech recognition task in noise. Results of off-line sentence scoring showed discrepancies between the target SRTs and the true performance obtained during the speech recognition task. For example, in the SRT80% condition, participants scored an average of 64.7%. Participants’ true performance levels were therefore used for subsequent statistical modelling. Results showed that both measures appeared to be sensitive to changes in spectral resolution (channel vocoding), while pupil dilation only was also significantly related to their true performance levels (%) and task accuracy (i.e., whether the response was correctly or partially recalled). The two measures were not correlated, suggesting they each may reflect different cognitive processes involved in listening effort. This combination of findings contributes to a growing body of research aiming to develop an objective measure of listening effort.

Overview

CoChat Summary

TL;DR

This study corecorded pupillometry and EEG alpha power in 19 young normal-hearing adults during a noise-vocoded speech recognition task to test whether two proposed physiological indices of listening effort assess similar processes. Both measures were sensitive to spectral degradation, but only pupil dilation tracked true performance and task accuracy, and the two measures were not correlated.

Key findings

  • Both measures were sensitive to spectral resolution: pupil size was 1.49% larger in 6-channel than 16-channel vocoding (p < .01), and alpha power change was −30.0% lower in 6-channel than 16-channel vocoding (p = .03).
  • Pupil dilation, but not alpha power, was related to true performance: as true performance increased toward 100%, pupil size decreased by −0.05% (p < .01), whereas alpha power showed no effect (p = .75).
  • Pupil size was 1.61% larger for partially correct than correctly recalled sentences (p < .01), while alpha power showed no task-accuracy effect (p = .63).
  • Pupil dilation and alpha power were not significantly correlated within individuals for any condition (n = 19, p > .05; collapsed mean r = .01, SD = .08).

Methods

  • Nineteen normal-hearing monolingual English-speaking adults (12 women, 7 men; mean age 27 years, SD = 4.28, range 22–34) were included after exclusions from 27 recruited; simultaneous pupil and EEG recordings were made during a speech recognition-in-noise task.
  • BKB-A sentences and four-talker babble were noise-vocoded into 16 or 6 channels; individual 50% and 80% SRTs were obtained behaviorally, and fixed participant-specific SNRs were used during physiological testing.
  • Linear mixed-effects models in R (nlme) with random intercept for individual tested effects of SRT/vocoding, true performance/vocoding, task accuracy/vocoding, and SNR; correlations were averaged across participants, and intraclass correlations assessed reliability.

Limitations

  • The paper states that alpha power analyses were confined to parietal electrodes and that the 8–12 Hz alpha band may be too coarse, potentially averaging parallel attentional (8–10 Hz) and linguistic/semantic (10–12 Hz) processes; future work should consider whole-head and narrow-band analyses.
  • The paper reports that true performance during physiological testing deviated from target SRTs, especially for the 80% SRT (true performance averaged 64.7% collapsed across vocoding; range of averages 36–93%), which may have contributed to the nonsignificant SRT effect; session differences in motivation/fatigue are also suggested.
  • Evident from the text: the sample was young, normal-hearing, and cognitively robust, so findings may not generalize to older adults or people with hearing loss; removing incorrect responses also reduced statistical power for alpha power.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1177/2331216517706396

Cites

77 of 77 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1. Average pupil size over time for all trials and participants, for 16 - and 6-channel vocoding. The 0 s timepoint refers to the beginning of noise. All sentences finished at the 3.5 s timepoint. Shading represents ± 1 SE of the mean. The top panel represents the presentation protocol.
Figure 1. Average pupil size over time for all trials and participants, for 16 - and 6-channel vocoding. The 0 s timepoint refers to the beginning of noise. All sentences finished at the 3.5 s timepoint. Shading represents ± 1 SE of the mean. The top panel represents the presentation protocol.CC BY-NC · PubMed Central
Figure 2. Time–frequency representation of the EEG activity averaged across all participants, in the parietal region, for 16 - and 6-channel vocoding. The time–frequency representations are relative to the activity occurring during the 1 s of noise beginning at the 0 s timepoint. All sentences finished at the 3.5 s timepoint.
Figure 2. Time–frequency representation of the EEG activity averaged across all participants, in the parietal region, for 16 - and 6-channel vocoding. The time–frequency representations are relative to the activity occurring during the 1 s of noise beginning at the 0 s timepoint. All sentences finished at the 3.5 s timepoint.CC BY-NC · PubMed Central
Figure 3. Mean ± 1 SE of maximum pupil size and alpha power change relative to baseline, by SRT and channel vocoding.
Figure 3. Mean ± 1 SE of maximum pupil size and alpha power change relative to baseline, by SRT and channel vocoding.CC BY-NC · PubMed Central
Figure 4. Pearson’s r correlation coefficients of pupil dilation and alpha power by participant and channel vocoding.
Figure 4. Pearson’s r correlation coefficients of pupil dilation and alpha power by participant and channel vocoding.CC BY-NC · PubMed Central

Verification

Claims the paper makes

0 Valid · 0 Not valid · 33 Not checked · 66 Own results and interpretations

61 more claims

Create a free account to see all 99 claims and to verify the 35 references still open.

See all claims — free account
  • It may state two separate claims as one. 19
  • Probably not a substantial claim. 19

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

2 more claims about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

3 of 3

Citations

Cites

Research works printed but not linked: 1

  1. Pichora-Fuller, M. K. (2006). Perceptual effort and apparent cognitive decline: implications for audiologic rehabilitation. Seminars in Hearing , 27 (4), 284–293. · DOI

Cited by

See all 128

Metadata

Authors
Miles, K., McMahon, C., Boisvert, I., Ibrahim, R., de Lissa, P., Graham, P., & Lyxell, B.
Affiliations
  • Linköping University (SE)
  • Macquarie University (AU)
Corresponding author
Miles, Kelly
Venue
Trends in Hearing
Published
2017-01
Volume
21
Pages
2331216517706396-2331216517706396
ISSN
2331-2165 (ISSN-L)
OpenAlex
W2741995250
Cited by
128
References
77
Citations by year
2026: 7 · 2025: 24 · 2024: 13 · 2023: 14 · 2022: 19 · 2021: 19 · 2020: 14 · 2019: 10 · 2018: 7 · 2017: 1
FWCI
9.63
Type
journal article
Language
en
Open access
Licence
  • cc-by-nc
  • journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
Locations
  • Trends in Hearing (publishedVersion, cc-by-nc)
  • Macquarie University (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
  • PubMed Central (publishedVersion, cc-by-nc)
  • DiVA (Digitala Vetenskapliga Arkivet) (submittedVersion, other-oa)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • Australian Government
  • Macquarie University
Topics
  • Health Sciences › Health Professions › Speech and Hearing › Hearing Loss and Rehabilitation
  • Life Sciences › Neuroscience › Sensory Systems › Hearing, Cochlea, Tinnitus, Genetics
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Phonetics and Phonology Research
Keywords
listening effort, pupil dilation, alpha power, speech perception in noise, spectral resolution, speech reception threshold, speech recognition (audiology), pupillometry, EEG, top-down processing, bottom-up processing
MeSH terms
Acoustic Stimulation, Adult, Alpha Rhythm, Attention, Auditory Threshold, Brain, Brain Mapping, Cognition, Electroencephalography, Female, Humans, Male, Noise, Perceptual Masking, Pupil, Speech Intelligibility, Speech Perception, Speech Reception Threshold Test, Time Factors, Mydriasis, Recognition, Psychology, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-11-19, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-11-19 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.