Quantitative Live-Cell Confocal Imaging of 3D Spheroids in a High-Throughput Format
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Accurately predicting the human response to new compounds is critical to a wide variety of industries. Standard screening pipelines (including both in vitro and in vivo models) often lack predictive power. Three-dimensional (3D) culture systems of human cells, a more physiologically relevant platform, could provide a high-throughput, automated means to test the efficacy and/or toxicity of novel substances. However, the challenge of obtaining high-magnification, confocal z stacks of 3D spheroids and understanding their respective quantitative limitations must be overcome first. To address this challenge, we developed a method to form spheroids of reproducible size at precise spatial locations across a 96-well plate. Spheroids of variable radii were labeled with four different fluorescent dyes and imaged with a high-throughput confocal microscope. 3D renderings of the spheroid had a complex bowl-like appearance. We systematically analyzed these confocal z stacks to determine the depth of imaging and the effect of spheroid size and dyes on quantitation. Furthermore, we have shown that this loss of fluorescence can be addressed through the use of ratio imaging. Overall, understanding both the limitations of confocal imaging and the tools to correct for these limits is critical for developing accurate quantitative assays using 3D spheroids.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The third dimension bridges the gap between cell culture and live tissue
Pampaloni, F., Reynaud, E. G., & Stelzer, E. H. K. (2007) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2236 · Cited by 2,817 · cited 5×
“Multicellular spheroids are emerging as a possible solution, but challenges still remain with respect to workflow, spheroid formation, the long-term stability of spheroids, and the high-magnification imaging of spheroids necessary to acquire the quantitative high-content information that spheroids can provide.(1,2,5,1…”
InfluentialModeling Tissue Morphogenesis and Cancer in 3D
Yamada, K. M., & Cukierman, E. (2007) · Cell · doi:10.1016/j.cell.2007.08.006 · Cited by 1,751
Multicellular tumor spheroids: An underestimated tool is catching up again
Hirschhaeuser, F., Menne, H., Dittfeld, C., West, J., Mueller-Klieser, W., & Kunz-Schughart, L. A. (2010) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2010.01.012 · Cited by 1,674
Opportunities and challenges for use of tumor spheroids as models to test drug delivery and efficacy
Mehta, G., Hsiao, A. Y., Ingram, M., Luker, G. D., & Takayama, S. (2012) · Journal of Controlled Release · doi:10.1016/j.jconrel.2012.04.045 · Cited by 1,172 · cited 2×
“Multicellular spheroids are emerging as a possible solution, but challenges still remain with respect to workflow, spheroid formation, the long-term stability of spheroids, and the high-magnification imaging of spheroids necessary to acquire the quantitative high-content information that spheroids can provide.(1,2,5,1…”
Vinci, M., Gowan, S., Boxall, F., Patterson, L., Zimmermann, M., Court, W., Lomas, C., Mendiola, M., Hardisson, D., & Eccles, S. A. (2012) · BMC Biology · doi:10.1186/1741-7007-10-29 · Cited by 1,024 · cited 1×
“For some cancer models, large spheroids with necrotic cores are thought to mimic the complexity of tumors in vivo.(12,22,27) But for other assays, such as those that use primary cells or that wish to replicate normal physiology, smaller spheroids are preferable with their high viability and lack of confounding influen…”
High-throughput 3D spheroid culture and drug testing using a 384 hanging drop array
Tung, Y.-C., Hsiao, A. Y., Allen, S. G., Torisawa, Y.-S., Ho, M., & Takayama, S. (2011) · The Analyst · doi:10.1039/c0an00609b · Cited by 969 · cited 2×
“For some cancer models, large spheroids with necrotic cores are thought to mimic the complexity of tumors in vivo.(12,22,27) But for other assays, such as those that use primary cells or that wish to replicate normal physiology, smaller spheroids are preferable with their high viability and lack of confounding influen…”
Chang, T. T., & Hughes-Fulford, M. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2007.0434 · Cited by 311
Chitcholtan, K., Asselin, E., Parent, S., Sykes, P. H., & Evans, J. J. (2013) · Experimental Cell Research · doi:10.1016/j.yexcr.2012.09.012 · Cited by 173
Cited by
Three-Dimensional Spheroids as In Vitro Preclinical Models for Cancer Research
Pinto, B., Henriques, A. C., Silva, P. M. A., & Bousbaa, H. (2020) · Pharmaceutics · doi:10.3390/pharmaceutics12121186 · Cited by 440
Challenges of applying multicellular tumor spheroids in preclinical phase
Han, S. J., Kwon, S., & Kim, K. S. (2021) · Cancer Cell International · doi:10.1186/s12935-021-01853-8 · Cited by 428
Shah, S., & D’Souza, G. G. M. (2025) · Cells · doi:10.3390/cells14100732 · Cited by 83
“The second strategy involves optical sectioning through confocal laser scanning microscopy, which acquires fluorescence from successive focal planes along the Z-axis to generate high-resolution Z-stacks of the spheroid’s internal structure [186,248].”
Atherton, E., Brown, S., Papiez, E., Restrepo, M. I., & Borton, D. A. (2021) · Scientific Reports · doi:10.1038/s41598-021-01616-5 · Cited by 10
Metadata
- Authors
- Leary, E., Rhee, C., Wilks, B. T., & Morgan, J. R.
- Venue
- SLAS Technology
- Publisher
- Elsevier BV
- Published
- 2018-06
- Volume
- 23
- Issue
- 3
- Pages
- 231-242
- ISSN
- 2472-6303 (ISSN-L)
- OpenAlex
- W2792018371
- Cited by
- 53
- References
- 8
- FWCI
- 2.42
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative Live-Cell Confocal Imaging of 3D Spheroids in a High-Throughput Format. https://app.cochat.ai/papers/10.1177/2472630318756058
- The paper
- Leary, E., Rhee, C., Wilks, B. T., & Morgan, J. R. (2018). Quantitative Live-Cell Confocal Imaging of 3D Spheroids in a High-Throughput Format. SLAS Technology. https://doi.org/10.1177/2472630318756058
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.