Reproducibility of exhaled nitric oxide measurements in healthy and asthmatic adults and children
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Airway inflammation in asthma is not measured routinely in clinical practice. Fractional exhaled nitric oxide (FE NO), a marker of airway inflammation, is increasingly used as an outcome measure in asthma intervention studies and yet the reproducibility of FE NO measurements is unknown. The reproducibility, daytoday, diurnal variation and perception of standardised FE NO measurements were examined in 59 subjects (40 children aged 7–13 yrs and 19 adults aged 18–60 yrs), both healthy (n=30) and with mild (n=29) asthma. FE NO was measured on five consecutive days (four measurements on the same day) for adults and twice on the same day for children. The coefficient of reproducibility expressed as the mean pooled standard deviation (n=59, 675 estimations) was 2.11 parts per billion (ppb) and intraclass correlation coefficient was 0.99 in both children and adults. FE NO was significantly higher in asthma subjects (32.3 ppb) than in healthy subjects (16.3 ppb). There was no diurnal or daytoday variation, or a learning effect, as the result of FE NO measurements were identical at results of the beginning and at the end of the study. It was concluded that fractional exhaled nitric oxide measurements are simple, reproducible, free from diurnal and daytoday variation, and acceptable by both healthy and asthmatic adults and children, as a part of their routine visit to a physician.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Increased nitric oxide in exhaled air of asthmatic patients
Kharitonov, S. A., Yates, D., Robbins, R. A., Barnes, P. J., Logan-Sinclair, R., & Shinebourne, E. A. (1994) · The Lancet · doi:10.1016/s0140-6736(94)90931-8 · Cited by 1,436
Self-citationExhaled Markers of Pulmonary Disease
KHARITONOV, S. A., & BARNES, P. J. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.7.2009041 · Cited by 844
Self-citation(1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.160.6.ats8-99 · Cited by 771
Kharitonov, S., Alving, K., & Barnes, P. (1997) · European Respiratory Journal · doi:10.1183/09031936.97.10071683 · Cited by 664
Self-citationInhaled glucocorticoids decrease nitric oxide in exhaled air of asthmatic patients.
Kharitonov, S. A., Yates, D. H., & Barnes, P. J. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.153.1.8542158 · Cited by 580
Self-citationThe Predictive Value of Exhaled Nitric Oxide Measurements in Assessing Changes in Asthma Control
JONES, S. L., KITTELSON, J., COWAN, J. O., FLANNERY, E. M., HANCOX, R. J., MCLACHLAN, C. R., & TAYLOR, D. R. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.164.5.2012125 · Cited by 439
Changes in Sputum Eosinophils Predict Loss of Asthma Control
JATAKANON, A., LIM, S., & BARNES, P. J. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.161.1.9809100 · Cited by 404
Self-citationIncreased exhaled nitric oxide in asthma is mainly derived from the lower respiratory tract.
Kharitonov, S. A., Chung, K. F., Evans, D., O'Connor, B. J., & Barnes, P. J. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.153.6.8665033 · Cited by 287
Self-citationChanges in the dose of inhaled steroid affect exhaled nitric oxide levels in asthmatic patients
Kharitonov, S., Yates, D., Chung, K., & Barnes, P. (1996) · European Respiratory Journal · doi:10.1183/09031936.96.09020196 · Cited by 243
Self-citationKharitonov, S. A. (2002) · Thorax · doi:10.1136/thorax.57.10.889 · Cited by 239
Self-citation
Cited by
(2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200406-710st · Cited by 3,203
Dweik, R. A., Boggs, P. B., Erzurum, S. C., Irvin, C. G., Leigh, M. W., Lundberg, J. O., Olin, A.-C., Plummer, A. L., & Taylor, D. R. (2011) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.9120-11st · Cited by 2,539
“The variation increases to approximately 20% in patients with asthma (75, 96, 97).”
British Guideline on the Management of Asthma
British Thoracic Society Scottish Intercollegiate Guidelines Network (2008) · Thorax · doi:10.1136/thx.2008.097741 · Cited by 2,021
Reddel, H. K., Taylor, D. R., Bateman, E. D., Boulet, L.-P., Boushey, H. A., Busse, W. W., Casale, T. B., Chanez, P., Enright, P. L., Gibson, P. G., et al. (2009) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200801-060st · Cited by 1,918
Use of Exhaled Nitric Oxide Measurements to Guide Treatment in Chronic Asthma
Smith, A. D., Cowan, J. O., Brassett, K. P., Herbison, G. P., & Taylor, D. R. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043596 · Cited by 974
Outcomes for COPD pharmacological trials: from lung function to biomarkers
Cazzola, M., MacNee, W., Martinez, F. J., Rabe, K. F., Franciosi, L. G., Barnes, P. J., Brusasco, V., Burge, P. S., Calverley, P. M. A., Celli, B. R., et al. (2008) · European Respiratory Journal · doi:10.1183/09031936.00099306 · Cited by 858
Self-citationExhaled nitric oxide measurements: clinical application and interpretation
Taylor, D. R., Pijnenburg, M. W., Smith, A. D., & Jongste, J. C. D. (2006) · Thorax · doi:10.1136/thx.2005.056093 · Cited by 507
Breath analysis by nanostructured metal oxides as chemo-resistive gas sensors
Righettoni, M., Amann, A., & Pratsinis, S. E. (2015) · Materials Today · doi:10.1016/j.mattod.2014.08.017 · Cited by 487
Szefler, S. J., Wenzel, S., Brown, R., Erzurum, S. C., Fahy, J. V., Hamilton, R. G., Hunt, J. F., Kita, H., Liu, A. H., Panettieri, R. A., et al. (2012) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2011.12.979 · Cited by 395
Measurements of exhaled nitric oxide in healthy subjects age 4 to 17 years
Buchvald, F., Baraldi, E., Carraro, S., Gaston, B., De Jongste, J., Pijnenburg, M. W. H., Silkoff, P. E., & Bisgaard, H. (2005) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2005.03.020 · Cited by 377
Exhaled Nitric Oxide: A Predictor of Steroid Response
Smith, A. D., Cowan, J. O., Brassett, K. P., Filsell, S., McLachlan, C., Monti-Sheehan, G., Herbison, G. P., & Taylor, D. R. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200411-1498oc · Cited by 371
The Use of Exhaled Nitric Oxide to Guide Asthma Management: A Randomized Controlled Trial
Shaw, D. E., Berry, M. A., Thomas, M., Green, R. H., Brightling, C. E., Wardlaw, A. J., & Pavord, I. D. (2007) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200610-1427oc · Cited by 341
Pulmonary Biomarkers in Chronic Obstructive Pulmonary Disease
Barnes, P. J., Chowdhury, B., Kharitonov, S. A., Magnussen, H., Page, C. P., Postma, D., & Saetta, M. (2006) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200510-1659pp · Cited by 298
Self-citationExhaled nitric oxide predicts asthma relapse in children with clinical asthma remission
Pijnenburg, M. W. (2005) · Thorax · doi:10.1136/thx.2004.023374 · Cited by 294
BARNES, P. J. (1996) · British Journal of Clinical Pharmacology · doi:10.1046/j.1365-2125.1996.03721.x · Cited by 270
Self-citationReference Ranges for Exhaled Nitric Oxide Derived from a Random Community Survey of Adults
Travers, J., Marsh, S., Aldington, S., Williams, M., Shirtcliffe, P., Pritchard, A., Weatherall, M., & Beasley, R. (2007) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200609-1346oc · Cited by 222
“chemoluminescence [ 3 ]. In health, the fraction of nitric oxide in exhaled breath (FENO)”
BackgroundExhaled nitric oxide from lung periphery is increased in COPD
Brindicci, C., Ito, K., Resta, O., Pride, N. B., Barnes, P. J., & Kharitonov, S. A. (2005) · European Respiratory Journal · doi:10.1183/09031936.04.00125304 · Cited by 206
“Mean eNO at each expiratory flow was calculated by the analyser during an NO plateau of o3 s with NO variability within 10% of the plateau or i1 ppb [ 1 ].”
BackgroundMethodResultInfluentialKharitonov, S. A., & Barnes, P. J. (2006) · Chest · doi:10.1378/chest.130.5.1541 · Cited by 196
Self-citationPerformance of a new hand-held device for exhaled nitric oxide measurement in adults and children
Alving, K., Janson, C., & Nordvall, L. (2006) · Respiratory Research · doi:10.1186/1465-9921-7-67 · Cited by 191
“In this study, the new hand-held device was compared to a chemiluminescence-based stationary device for exhaled NO measurements that has previously proven to provide repeatable results [14].”
MethodHuman asthma phenotypes: from the clinic, to cytokines, and back again
Bhakta, N. R., & Woodruff, P. G. (2011) · Immunological Reviews · doi:10.1111/j.1600-065x.2011.01032.x · Cited by 186
“FeNO is a highly reproducible measurement that is relatively easy to perform for both patients and providers (91).”
Silkoff, P. E., Carlson, M., Bourke, T., Katial, R., Ögren, E., & Szefler, S. J. (2004) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2004.08.042 · Cited by 163
Airway responsiveness and inflammation in adolescent elite swimmers
Pedersen, L., Lund, T. K., Barnes, P. J., Kharitonov, S. A., & Backer, V. (2008) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2008.04.041 · Cited by 75
“FeNO measurements have been shown to be reproducible and free from diurnal and day-to-day variation.(34) EBC.”
BackgroundSelf-citationExhaled markers of inflammatory lung diseases: ready for routine monitoring?
Kharitonov, S. (2004) · Swiss Medical Weekly · doi:10.4414/smw.2004.10411 · Cited by 74
Self-citationMarkers of lung disease in exhaled breath: nitric oxide
Choi, J., Hoffman, L. A., Rodway, G. W., & Sethi, J. M. (2006) · Biological Research For Nursing · doi:10.1177/1099800405286131 · Cited by 43
Metadata
- Authors
- Kharitonov, S. A., Gonio, F., Kelly, C., Meah, S., & Barnes, P. J.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2003-03
- Volume
- 21
- Issue
- 3
- Pages
- 433-438
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2134129134
- Cited by
- 315
- References
- 26
- FWCI
- 11.22
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.