Exhaled breath condensate: methodological recommendations and unresolved questions
Open accessThe DOI matches its Crossref record; 281 of the 281 references it cites were found in a registry or an index.
Abstract
Collection of exhaled breath condensate (EBC) is a noninvasive method for obtaining samples from the lungs. EBC contains large number of mediators including adenosine, ammonia, hydrogen peroxide, isoprostanes, leukotrienes, nitrogen oxides, peptides and cytokines. Concentrations of these mediators are influenced by lung diseases and modulated by therapeutic interventions. Similarly EBC pH also changes in respiratory diseases. The aim of the American Thoracic Society/European Respiratory Society Task Force on EBC was to identify the important methodological issues surrounding EBC collection and assay, to provide recommendations for the measurements and to highlight areas where further research is required. Based on the currently available evidence and the consensus of the expert panel for EBC collection, the following general recommendations were put together for oral sample collection: collect during tidal breathing using a noseclip and a saliva trap; define cooling temperature and collection time (10 min is generally sufficient to obtain 1–2 mL of sample and well tolerated by patients); use inert material for condenser; do not use resistor and do not use filter between the subject and the condenser. These are only general recommendations and certain circumstances may dictate variation from them. Important areas for future research involve: ascertaining mechanisms and site of exhaled breath condensate particle formation; determination of dilution markers; improving reproducibility; employment of EBC in longitudinal studies; and determining the utility of exhaled breath condensate measures for the management of individual patients. These studies are required before recommending this technique for use in clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“EBC was obtained approximately 70 min before swimming began and 35 min after swimming ended using an EcoScreen condenser (Jaeger GmbH, Würzburg, Germany) following American Thoracic Society/European Respiratory Society Task Force recommendations (Horvath et al. 2005).”
From Short-Term Changes in Respiratory Biomarkers after Swimming in a Chlorinated Pool (2010) · cites this paper as Horvath et al. 2005
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Brainard, D. H. (1997) · Spatial Vision · doi:10.1163/156856897x00357 · Cited by 19,702
The VideoToolbox software for visual psychophysics: transforming numbers into movies
Pelli, D. G. (1997) · Spatial Vision · doi:10.1163/156856897x00366 · Cited by 11,098
Mixed-Effects Models in S and S-PLUS
(2001) · Technometrics · doi:10.1198/tech.2001.s574 · Cited by 9,278
Best Linear Unbiased Estimation and Prediction under a Selection Model
Henderson, C. R. (1975) · Biometrics · doi:10.2307/2529430 · Cited by 2,497
Metabonomics: a platform for studying drug toxicity and gene function
Nicholson, J. K., Connelly, J., Lindon, J. C., & Holmes, E. (2002) · Nature Reviews Drug Discovery · doi:10.1038/nrd728 · Cited by 1,914
Nonlinear Mixed Effects Models for Repeated Measures Data
Lindstrom, M. J., & Bates, D. M. (1990) · Biometrics · doi:10.2307/2532087 · Cited by 1,795
That BLUP is a Good Thing: The Estimation of Random Effects
Robinson, G. K. (1991) · Statistical Science · doi:10.1214/ss/1177011926 · Cited by 1,686
Effects of antioxidant enzymes in the molecular control of reactive oxygen species toxicology
Matés, >. M. (2000) · Toxicology · doi:10.1016/s0300-483x(00)00306-1 · Cited by 1,518
Peroxynitrite-mediated tyrosine nitration catalyzed by superoxide dismutase
Ischiropoulos, H., Zhu, L., Chen, J., Tsai, M., Martin, J. C., Smith, C. D., & Beckman, J. S. (1992) · Archives of Biochemistry and Biophysics · doi:10.1016/0003-9861(92)90431-u · Cited by 1,495
Research works printed but not linked: 40
- 2002, Am J Respir Crit Care Med, 65, 663
- 1999, Eur Respir Rev, 68, 246
- 1985, Am Rev Respir Dis, 131, 894
- 2002, Eur J Med Res, 7, 353
- 2003, Eur J Med Res, 8, 505
- 1998, Monaldi Arch Chest Dis, 53, 268
- 1999, Eur Respir J, 14, 245
- 10.1002/1615-9861(200206)2:6<690::aid-prot690>3.0.co;2-6 · doi:10.1002/1615-9861(200206)2:6<690::aid-prot690>3.0.co;2-6
- 2000, Monaldi Arch Chest Dis, 55, 185
- 2003, Clin Lab, 49, 637
- 1997, Eur Respir J, 10, 1231
- 1986, Lancet, I, 11
- 1993, Anesth Analg, 77, 963
- 2003, Physiol Res, 52, 327
- 1995, Lancet, 346, 1235
- 10.1053/rmed.2001.1117 · DOI
- 1993, J Pharmacol Exp Ther, 267, 1529
- 1993, Am Rev Respir Dis, 15, 161
- 2002, Int Marit Health, 53, 93
- 1995, Appl Cardiopulmon Pathophysiol, 5, 215
- 10.1164/rccm.200206-507oc · DOI · Paper page
- 2003, Am J Respir Crit Care Med, 167, 91
- 2002, Int J Biol Markers, 17, 141
- 2001, J Heart Lung Transplant, 20, 184
- 1998, Pneumologie, 52, 426
- 2002, Eur J Med Res, 7, 290
- 2002, Curr Opin Pulm Med, 1, 25
- 2002, Int J Occup Med Environ Health, 15, 317
- 2003, Am J Respir Crit Care Med, 168, 1129
- 2004, Undersea Hyperb Med, 31, 217
- 2004, Physiol Res, 53, 561
- 2004, J Chromatogr B Analyt Technol Biomed Life Sci, 809, 199, 10.1016/s1570-0232(04)00513-6 · doi:10.1016/s1570-0232(04)00513-6
- 10.1007/s00408-004-2506-3 · DOI
- 10.1136/vr.155.23.744 · doi:10.1136/vr.155.23.744
- 2004, Thorax, 59, 1005
- 10.1002/rcm.1682 · DOI
- 2004, Physiol Res, 53, 561
- 10.1016/j.jfms.2003.12.002 · DOI
- 2004, Environ Health Perspect, 112, 1293, 10.1289/ehp.7108 · DOI
- 10.1016/s0956-5663(02)00083-0 · DOI · Paper page
Cited by
Items 901–1,000 of 1,000
Briceño, F. A. C., Espinosa‐Ramírez, M., Viscor, G., & Araneda, O. F. (2020) · European Journal of Applied Physiology · doi:10.1007/s00421-020-04456-9 · Cited by 7
“In the respiratory system, its genesis falls on phagocytes, type II pneumocytes, and epithelial cells of the airway (Horváth et al. 2005; Araneda et al. 2016).”
BackgroundMethodGade, I. L., Schultz, J. G., Cehofski, L. J., Kjærgaard, B., Severinsen, M. T., Rasmussen, B. S., Vorum, H., Honoré, B., & Kristensen, S. R. (2020) · Journal of Breath Research · doi:10.1088/1752-7163/abd3f2 · Cited by 8
“Also, importantly, the controlled volume of exhaled breath during mechanical ventilation minimizes variations in EBC volumes caused by individual breathing patterns [8, 30].”
Changes in exhaled breath condensate pH in healthy and asthmatic pregnant women
Eszes, N., Bikov, A., Lázár, Z., Bohács, A., Müller, V., Stenczer, B., Rigó, J. J., Losonczy, G., Horváth, I., & Tamási, L. (2013) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.1111/aogs.12094 · Cited by 7
Self-citationImmunological and inflammatory assessments
Lemière, C., & Bernstein, D. I. (2013) · CRC Press eBooks · doi:10.1201/b15116-13 · Cited by 7
Optoelectronic Control of the Phase and Frequency of Semiconductor Lasers
Satyan, N. (2011) · CaltechTHESIS (California Institute of Technology) · doi:10.7907/24dm-vw62 · Cited by 7
Rizik, S., Bar‐Yoseph, R., Hanna, M., Hakim, F., Broza, Y. Y., Sader, A., Toukan, Y., Haick, H., Bentur, L., & Gur, M. (2025) · ERJ Open Research · doi:10.1183/23120541.01096-2024 · Cited by 7
“- Serum and exhaled breath condensate (EBC) cytokines : EBC (a noninvasive sampling of the lower airways) was collected in dedicated test tubes (Respiratory Research, Charlottesville, VA, USA) according to the manufacturer ’ s instructions and ERS recommendations [31, 32].”
Breath biopsy biomarkers: cell-free nucleic acids in exhaled breath condensate
Pös, O., Styk, J., Kubanova, M., Bokorová, S., Buglyó, G., Soltész, B., Lukasz, P., Beneš, V., Repiská, V., Nagy, B., et al. (2025) · Frontiers in Medicine · doi:10.3389/fmed.2025.1693114 · Cited by 6
Redox signaling in chronic airway diseases: pathogenic mechanisms and therapeutic implications
Cazzola, M., Rogliani, P., Calzetta, L., van Haren, F. M. P., Page, C. P., & Matera, M. G. (2026) · Frontiers in Physiology · doi:10.3389/fphys.2026.1734890 · Cited by 7
“4-HNE can be measured in both sputum and exhaled breath condensate, although its quantification is technically difficult due to rapid metabolism (Horváth et al., 2005).”
Association between long‐term occupational exposure to PM 10 and allergic diseases in subway workers
Freund, R., Sauvain, J., Suárez, G., Wild, P. P., Charreau, T., Pralong, J. A., Debatisse, A., Jouannique, V., Sakthithasan, K., & Canu, I. G. (2024) · Clinical & Experimental Allergy · doi:10.1111/cea.14472 · Cited by 6
PATTNAIK, B. R., Sryma, P., Bhatraju, N. K., Mittal, S., Arava, S., Jain, D., Nayak, B., Tiwari, P., Hadda, V., Mohan, A., et al. (2024) · ERJ Open Research · doi:10.1183/23120541.00078-2024 · Cited by 6
“The surge of interest in the study of EBC led to the formation of guidelines by a joint task force of the American Thoracic Society (ATS) and European Respiratory Society (ERS) in 2001 [16].”
Sensor platform for noninvasive evaluation of pulmonary oxidative status
Andreev, E. A., Shavokshina, V. A., Nikitina, V. N., Pozdnyakova, D. D., Baranova, I. A., Chuchalin, A. G., & Karyakin, A. A. (2025) · Talanta · doi:10.1016/j.talanta.2025.127792 · Cited by 6
Partial Oxygen and Carbon Dioxide Pressure of Exhaled Breath Condensate
Dodig, S., Čepelak, I., Vlašić, Ž., Topić, R. Z., Živčić, J., & Nogalo, B. (2008) · Laboratory Medicine · doi:10.1309/63e061u2yrv5t2a9 · Cited by 7
Jing, J., Sang, X., You, S., Zhu, B., Cui, Y., Li, C., Wang, Z., Zhao, X., Liu, X., Tian, M., et al. (2021) · Hepatology Research · doi:10.1111/hepr.13594 · Cited by 7
Ruzsányi, V., & Kalapos, M. P. (2023) · Journal of Breath Research · doi:10.1088/1752-7163/ace647 · Cited by 6
“Moreover, different methodological aspects can vary the constitution of EBC among others the use of nose clip [18] or face mask [19] during sampling, the collection through the mouth or endotracheal tubes [18], the application of inspiratory filters [20] and different exhalation maneuvers [21].”
InfluentialParticles in Exhaled Air (PExA): Clinical Uses and Future Implications
Roe, T., Silveira, S., Luo, Z., Osborne, E. L., Murugan, G. S., Grocott, M. P. W., Postle, A. D., & Dushianthan, A. (2024) · Diagnostics · doi:10.3390/diagnostics14100972 · Cited by 8
“The European Respiratory Society (ERS) and American Thoracic Society (ATS) Task Force (TF) defines EBC as exhaled breath cooled to a fluid or frozen using a condenser [20,21].”
BackgroundBano, A., Yadav, P., Sharma, M., Verma, D., Vats, R., Chaudhry, D., Kumar, P., & Bhardwaj, R. (2024) · Journal of Breath Research · doi:10.1088/1752-7163/ad5eae · Cited by 7
“RTUBE (Respiratory Research, Inc. Austin, TX), a portable device used for breath condensation and collection, was utilized to collect EBC samples [15].”
Breath: An Often Overlooked Medium in Biomarker Discovery
Beauchamp, J. D., & Pleil, J. D. (2015) · Wiley eBooks · doi:10.1002/9783527680658.ch5 · Cited by 8
Nitric Oxide in the Exhaled Breath Condensate of Healthy Volunteers Collected With a Reusable Device
Vento, D. A., Arcêncio, L., & Rodrigues, A. J. (2012) · Archivos de Bronconeumología · doi:10.1016/j.arbr.2011.11.011 · Cited by 9
Airway oxidative stress in chronic cough
Koskela, H. O., & Purokivi, M. (2013) · Cough · doi:10.1186/1745-9974-9-26 · Cited by 7
“EBC is a very dilute solution of biomarkers and for many of them, assays are often employed at or near their detection limits [24].”
BackgroundMethodHoffmeyer, F., Bünger, J., Monsé, C., Berresheim, H., Jettkant, B., Beine, A., Brüning, T., & Sucker, K. (2016) · Advances in experimental medicine and biology · doi:10.1007/5584_2016_242 · Cited by 6
du Preez, S., Raidal, S. L., Doran, G., Nielsen, S. G., & Hughes, K. (2017) · The Veterinary Journal · doi:10.1016/j.tvjl.2017.07.005 · Cited by 6
Study of the Molecular Composition of Exhaled Breath Condensate by High-Resolution Mass Spectrometry
Kononikhin, A. S., Zakharova, N. V., Yusupov, A. E., Ryabokon, A. M., Fedorchenko, K. Y., Indeykina, M. I., Бугрова, А. Е., Spassky, A. I., Popov, I. A., Varfolomeev, S. D., et al. (2019) · Russian Journal of Physical Chemistry B · doi:10.1134/s1990793119060216 · Cited by 6
Soma, T., Uchida, Y., Nakagome, K., Hoshi, R., & Nagata, M. (2020) · Allergology International · doi:10.1016/j.alit.2020.04.014 · Cited by 6
Approaches to Sampling the Respiratory Microbiome
Dickson, R. P. (2022) · Respiratory medicine · doi:10.1007/978-3-030-87104-8_1 · Cited by 7
Takahashi, S., Anada, M., Kinoshita, T., Nishide, T., & Shibata, T. (2022) · In Vivo · doi:10.21873/invivo.12855 · Cited by 6
Quartz Crystal Microbalance Study of Acetone Vapor Adsorption onto Microporous Carbon Adsorbent
Simonov, V. N., Artamonova, S. D., Фомкин, А. А., Shkolin, A. V., & Men’shchikov, I. E. (2022) · Protection of Metals and Physical Chemistry of Surfaces · doi:10.1134/s2070205122040220 · Cited by 6
Awchi, M., Sinues, P., Datta, A., García‐Gómez, D., & Singh, K. D. (2023) · Journal of Proteome Research · doi:10.1021/acs.jproteome.2c00835 · Cited by 6
Rubio, K., Müller, J. M., Mehta, A., Watermann, I., Olchers, T., Koch, I., Wessels, S., Schneider, M. A., Araujo-Ramos, T., Singh, I., et al. (2023) · Discover Oncology · doi:10.1007/s12672-023-00799-9 · Cited by 6
“Briefly, EBC collection was performed using the RTube (Respiratory Research) as described online (http:// www. res piratoryresearch.com/products-rtube-how.htm) and following the guidelines for EBC sampling by the ERS/ATS Task Force [27, 28].”
MethodExhaled Breath Condensate pH in Lung Cancer, the Impact of Clinical Factors
Bikov, A., Lázár, Z., Gyulai, N., Szentkereszty, M., Losonczy, G., Horváth, I., & Gálffy, G. (2015) · Lung · doi:10.1007/s00408-015-9778-7 · Cited by 6
“cooled chamber [2].”
Self-citationFabrication of Homogeneous High-Density Antibody Microarrays for Cytokine Detection
Hospach, I., Joseph, Y., Mai, M., Krasteva, N., & Nelles, G. (2014) · Microarrays · doi:10.3390/microarrays3040282 · Cited by 6
Stern, G., Latzin, P., Thamrin, C., & Frey, U. (2007) · Paediatric Respiratory Reviews · doi:10.1016/j.prrv.2007.07.008 · Cited by 7
Analysis of human exhaled breath in a population of young volunteers
Zarić, B. L., Petrović, S., Bjekić, M., Rajic, I., Popović, A. R., & Djordjevic, D. S. (2014) · Archives of Biological Sciences · doi:10.2298/abs1404529z · Cited by 6
Tahan, F., Akar, H. H., & Saraymen, B. (2015) · Allergologia et Immunopathologia · doi:10.1016/j.aller.2014.10.003 · Cited by 6
Górska, K., Nejman‐Gryz, P., Paplińska‐Goryca, M., Proboszcz, M., & Krenke, R. (2016) · Advances in experimental medicine and biology · doi:10.1007/5584_2016_162 · Cited by 7
Role of serum periostin as a biomarker in diagnosis of bronchial asthma
Ibrahim, I., Mohammed, D. A., Abdelnaby, A. Y., & Zamran, E. E. (2018) · Egyptian Journal of Chest Diseases and Tuberculosis · doi:10.4103/ejcdt.ejcdt_4_17 · Cited by 6
Biomarkers of respiratory allergy in laboratory animal care workers: an observational study
Tafuro, F., Selis, L., Goldoni, M., Stendardo, M., Mozzoni, P., Ridolo, E., Boschetto, P., & Corradi, M. (2018) · International Archives of Occupational and Environmental Health · doi:10.1007/s00420-018-1321-8 · Cited by 6
van der Zee, P. A., van Walree, I. C., Fijen, J.-W., van Houte, A., van Velzen‐Blad, H., Rijkers, G. T., Gommers, D. A. M. P. J., & Endeman, H. (2020) · Disease Markers · doi:10.1155/2020/2696317 · Cited by 6
“We decided to present the raw data as there is no consensus on the calculation of EBC sample dilution [3, 5].”
MethodKlein, E. F., Adir, Y., Fireman, E. M., & Kessel, A. (2020) · ERJ Open Research · doi:10.1183/23120541.00361-2019 · Cited by 8
Terrington, D. L., Kim, J. W., Ravenhill, G., TANG, J. C. Y., Piec, I., Fowler, S. J., Fraser, W. D., & Wilson, A. M. (2020) · Journal of Breath Research · doi:10.1088/1752-7163/abb763 · Cited by 6
“The principle composition of EBC is water vapour [39] with small amounts of water soluble volatile compounds and non-volatile molecules [8].”
BackgroundMethodKreißl, S., Hendler, S., Akmatov, M. K., von Meien, M., Range, U., Peßler, F., & Vogelberg, C. (2020) · The Journal of Allergy and Clinical Immunology In Practice · doi:10.1016/j.jaip.2020.10.058 · Cited by 9
Horváth, I., Szili, B., & Kullmann, T. (2006) · European Respiratory Journal · doi:10.1183/09031936.06.00033506 · Cited by 6
Self-citationCollecting exhaled breath condensate from non-ventilated preterm-born infants: a modified method
Urs, R. C., Stoecklin, B., Pillow, J. J., Hartmann, B., Hall, G. L., & Simpson, S. J. (2021) · Pediatric Research · doi:10.1038/s41390-021-01474-x · Cited by 6
Fox, L., Gates, J., Vos, R. D., Wiffen, L., Hicks, A., Rupani, H., Williams, J., Brown, T., & Chauhan, A. (2021) · JMIR Research Protocols · doi:10.2196/23831 · Cited by 6
Mubarak, B., Shakoor, H., & Masood, F. (2019) · IntechOpen eBooks · doi:10.5772/intechopen.84297 · Cited by 8
“EBC is obtained at the time of quiet respiration, as a result of cooling and liquefaction of the air droplets that breathe out [51].”
BackgroundSimpson, J. L., & Wark, P. A. B. (2008) · Expert Opinion on Medical Diagnostics · doi:10.1517/17530059.2.6.607 · Cited by 6
Collection of Aerosolized Human Cytokines Using Teflon® Filters
McKenzie, J. H., McDevitt, J., Fabian, M. P., Hwang, G. M., & Milton, D. K. (2012) · PLoS ONE · doi:10.1371/journal.pone.0035814 · Cited by 6
“EBC samples consist of a mixture of three main components [6].”
BackgroundMethodInfluentialKlinische und diagnostische Befunde bei Exposition gegenüber Nanopartikeln und neuen Materialien
Mittmann-Frank, M., Berger, H., Pföhler, C., Bücker, A., Wilkens, H., Arzt, E., Schmitt, K., Wennemuth, G., Hannig, M., & Buchter, A. (2010) · Zentralblatt für Arbeitsmedizin Arbeitsschutz und Ergonomie · doi:10.1007/bf03344310 · Cited by 6
“Als wesentlicher und sehr sensitiver Entzündungsmarker wird er von neutrophilen und eosinophilen Granulozyten sowie von Makrophagen und Epithel - zellen freigesetzt (Horvath et al. 2005).”
BackgroundSibilancias recurrentes en menores de tres años: evidencias y oportunidades
Pérez‐Yarza, E. G., Sardón‐Prado, O., & Murúa, J. K. (2008) · Anales de Pediatría · doi:10.1157/13126564 · Cited by 12
Kurova, V. S., Kurochkin, I., Kalamkarov, G. R., Бугрова, А. Е., Fedorchenko, K. Y., & Varfolomeev, S. D. (2009) · Biotechnology Advances · doi:10.1016/j.biotechadv.2009.05.010 · Cited by 5
Streckenbach, B. (2022) · CHIMIA International Journal for Chemistry · doi:10.2533/chimia.2022.322 · Cited by 5
Ljubičić, A., Varnai, V. M., Vučemilo, M., Matković, K., Milić, D., & Macan, J. (2014) · Journal of Occupational and Environmental Medicine · doi:10.1097/jom.0000000000000151 · Cited by 5
Exhaled nitric oxide and other major exhaled compounds for the diagnosis of metabolic diseases
Maniscalco, M., Palladino, F., Mormile, M., & Sofia, M. (2009) · Expert Opinion on Medical Diagnostics · doi:10.1517/17530050903104072 · Cited by 5
“) plus some droplets from the airway lining fluid [50,51].”
BackgroundInfluentialExhaled matrix metalloproteinase 9 in patients with stable COPD - an observational study
Maskey‐Warzęchowska, M., Górska, K., Nejman‐Gryz, P., Paplińska‐Goryca, M., Grzela, T., Krejner, A., Grzela, K., & Krenke, R. (2018) · Polskie Archiwum Medycyny Wewnętrznej · doi:10.20452/pamw.4302 · Cited by 6
Sharma, A. K. (2023) · IntechOpen eBooks · doi:10.5772/intechopen.104046 · Cited by 5
Liu, M., Cheng, Z. J., Xue, M., Lin, R., Zhang, T., & Sun, B. (2023) · Precision Medical Sciences · doi:10.1002/prm2.12106 · Cited by 5
Mitchell, M. I., Ben‐Dov, I. Z., Liu, C., Wang, T., Hazan, R. B., BAUER, T. L., Zakrzewski, J. L., Donnelly, K., Chow, K. F., Ma, J., et al. (2024) · Extracellular Vesicles and Circulating Nucleic Acids · doi:10.20517/evcna.2023.77 · Cited by 5
New markers in chronic obstructive pulmonary disease
Akdeniz, Y. S., & Özkan, S. (2024) · Advances in clinical chemistry · doi:10.1016/bs.acc.2024.06.001 · Cited by 6
Szili, B., Bikov, A., Kollai, M., & Horváth, I. (2007) · Orvosi Hetilap · doi:10.1556/oh.2007.27986 · Cited by 5
Self-citationInterleukins and other proteins
Geßner, C., & Wirtz, H. R. W. (2010) · European Respiratory Society eBooks · doi:10.1183/1025448x.00019509 · Cited by 5
Analyses of exhaled breath condensate cytokines for identification of lung cancer
Geßner, C., Ruschpler, P., Fricke, S., Gillissen, A., Hoheisel, G. B., Lehmann, J., & Sack, U. (2017) · Journal of Laboratory Medicine · doi:10.1515/labmed-2017-0054 · Cited by 5
“Nevertheless, the application of EBC protein analysis in clinical routine requires further validation and standardization of specific biomarkers and their assign to each pathogenic issue of the lung [33].”
MethodDickson, R. P., & Cox, M. J. (2019) · European Respiratory Society eBooks · doi:10.1183/2312508x.10015418 · Cited by 8
Avaliação da inflamação das vias aéreas. Vias áreas superiores e compartimento broncopulmonar
Geraldes, L., Todo‐Bom, A. M., Loureiro, C., & Pinto, M. (2009) · Revista Portuguesa de Pneumologia · doi:10.1016/s0873-2159(15)30145-8 · Cited by 6
Duman, B., Börekçi, Ş., Akdeniz, N., Gazioglu, S. B., Deniz, G., & Gemicioğlu, B. (2021) · Journal of Asthma · doi:10.1080/02770903.2021.1962341 · Cited by 5
“A number of noninvasive methods are used to indicate inflammation in the airways in asthma, such as sputum samples and various markers in exhaled breath samples (10,21,22).”
BackgroundMethodPutative Biomarkers for Acute Pulmonary Embolism in Exhaled Breath Condensate
Gade, I. L., Schultz, J. G., Brøndum, R. F., Kjærgaard, B., Nielsen‐Kudsk, J. E., Andersen, A., Kristensen, S. R., & Honoré, B. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10215165 · Cited by 5
“This biological specimen, called exhaled breath condensate (EBC), can be collected non-invasively in both conscious and intubated individuals [4].”
BackgroundCourse, C. W., Lewis, P. A., Kotecha, S. J., Cousins, M., Hart, K., Watkins, W. J., Heesom, K. J., & Kotecha, S. (2023) · Scientific Reports · doi:10.1038/s41598-023-34233-5 · Cited by 5
Genomic and systems approaches to translational biomarker discovery in immunological diseases
MacIsaac, K. D., Wang, I., Menetski, J. P., & Roberts, C. (2013) · Drug Discovery Today · doi:10.1016/j.drudis.2013.10.002 · Cited by 5
Dennis, J. O., Rabih, A. A. S., Khir, M. H. M., Abdullah, M. A., & Ahmed, M. G. (2015) · Journal of biomimetics, biomaterials and biomedical engineering · doi:10.4028/www.scientific.net/jbbbe.22.77 · Cited by 5
“The collection of EBC sample requires tidal breathing through a mouthpiece and a non-rebreathing valve into a cooled collection chamber [5, 28], and it needs preservation under special conditions such as low temperature and specific pH to keep H2O2 from degradation [14, 15].”
BackgroundMethodInfluentialCollection of exhaled breath and exhaled breath condensate in veterinary medicine. A review
Zollinger, E., Clauß, M., Steinmetz, H. W., & Hatt, J. (2006) · Veterinary Quarterly · doi:10.1080/01652176.2006.9695215 · Cited by 6
Liu, H., Li, Z., Zhang, X., Zhao, J., Chai, J., & Chang, C. (2025) · Microorganisms · doi:10.3390/microorganisms13081761 · Cited by 4
“EBC collection adhered to the recent ATS/ERS recommendations [21].”
The exhaled breath pattern as a potential method for biometrics identification
Paleczek, A., Grochala, J., Grochala, D., Pręgowska, A., Osial, M. E., Oyeleke, R. O., Pihut, M., Loster, J. E., & Rydosz, A. M. (2025) · Scientific Reports · doi:10.1038/s41598-025-19463-z · Cited by 4
“The exhaled breath analysis in terms of medical applications is well-known, and it has been a subject of research for the last four decades, fractioned exhaled nitric oxide (FeNO) 48 and exhaled breath condensate (EBC) analysis 49 have been approved by medical societies for clinical use.”
Markers of pancreatic function in the breath
Roberts, K., Liu, I., Jaffé, A., Verge, C. F., & Thomas, P. S. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/4/046009 · Cited by 4
“Dilution of EBC was not estimated in this study as there is no standardized and validated method for calculating dilution and changes in lung function have not been shown to result in changes in dilution of EBC samples [15, 26].”
MethodNoninvasive evaluation of airway inflammation in patients with severe asthma
Papaporfyriou, A., Tseliou, E., Loukides, S., Κostikas, Κ., & Bakakos, P. (2013) · Annals of Allergy Asthma & Immunology · doi:10.1016/j.anai.2012.12.026 · Cited by 4
Stolk, J. N., Fumagalli, M., Viglio, S., & Iadarola, P. (2015) · COPD Journal of Chronic Obstructive Pulmonary Disease · doi:10.3109/15412555.2015.1021910 · Cited by 4
Advances in exhaled breath condensate markers for severe asthma management: a systematic review
Gagliani, C., Brinkman, P., Riccio, M. D., Benfante, A., Khamas, S. S., der Zee, A. H. M., Principe, S., & Scichilone, N. (2025) · Expert Review of Respiratory Medicine · doi:10.1080/17476348.2025.2522743 · Cited by 4
“EIA approach is cheaper and easier to perform but less sensitive and specific than GC-MS [66] and it has some weaknesses in the analysis of EBC (i.e. the assay works close to its detection limit).”
Li, W., & Glaum, M. C. (2017) · Springer eBooks · doi:10.1007/978-981-10-1998-2_4 · Cited by 5
Hao, W., Li, M., Zhang, Y., Zhang, C., & Wang, P. (2019) · Lung · doi:10.1007/s00408-019-00263-y · Cited by 4
Kanık, E. T., Yılmaz, Ö., Özdoğru, E., Alper, H., Ulman, C., Kanık, A., Simsek, Y., & Yüksel, H. (2020) · Journal of Breath Research · doi:10.1088/1752-7163/ab670d · Cited by 4
Organic Volatile Compounds Used in Type 2 Diabetes
Petrus, M., Popa, C., & Bratu, A. (2021) · IntechOpen eBooks · doi:10.5772/intechopen.94752 · Cited by 4
О роли цитокинов при бронхиальной астме
Дугарова, И. Д., Anaev, E. K., & Чучалин, А. Г. (2009) · PULMONOLOGIYA · doi:10.18093/0869-0189-2009-4-96-102 · Cited by 4
Portacci, A., Pierucci, P., Quaranta, V. N., Quaranta, S., Iorillo, I., Locorotondo, C., Buonamico, E., Dragonieri, S., & Carpagnano, G. E. (2022) · Expert Review of Respiratory Medicine · doi:10.1080/17476348.2022.2130764 · Cited by 5
“easy to perform, although it requires a variable amount of time to complete the sampling procedure [9].”
BackgroundThe influence of advanced materials on the analytical performance of semiconductor-based gas sensors
Jouyban‐Gharamaleki, V., Jin, H., Jouyban, A., & Soleymani, J. (2023) · Physical Chemistry Chemical Physics · doi:10.1039/d3cp01756g · Cited by 4
Kaske, M., Reinhold, P., Pardon, B., & Bokma, J. (2024) · Springer eBooks · doi:10.1007/978-3-031-51788-4_12 · Cited by 6
Novel extraction of volatile biomarkers from canine breath for gas chromatography–mass spectrometry
Dissanayake, S., Lathan, P., & Mlsna, T. (2012) · Journal of Breath Research · doi:10.1088/1752-7155/6/4/041001 · Cited by 4
“Numerous studies have been completed on this topic, but the literature is difficult to compare because variations in sample collection, concentration and analytical instrumentation preclude proper comparisons (Horvath et al 2005).”
BackgroundMethodExhaled Breath Condensate in Critically Ill Mechanically Ventilated Patients
Roca, O., & Masclans, J. R. (2012) · Clinical Pulmonary Medicine · doi:10.1097/cpm.0b013e3182493892 · Cited by 4
“Leukotriene B4 Moloney et al(11) 45 26 CABG 19 lobectomy 64 (56-72)w RTube Prelobectomy 4 (2-11) pg/mLz Postlobectomy 23 (5-64) pg/mLz Roca et al(15) 6 ALI 56 (46-76)z EcoScreen Before salbutamol 1.”
BackgroundSmith, K. F., Quinn, R. L., & Rahilly, L. J. (2015) · Journal of Veterinary Emergency and Critical Care · doi:10.1111/vec.12317 · Cited by 12
Mesure de l’inflammation pulmonaire dans la mucoviscidose
Fayon, M. J., Chiron, R., & Abély, M. (2008) · Revue des Maladies Respiratoires · doi:10.1016/s0761-8425(08)73800-2 · Cited by 5
Analysis of Exhaled Breath Condensate in a Mixed Population of Psittacine Birds
Foldenauer, U., Simova-Curd, S., Nitzl, D., Bogdanova, A. Y., Zollinger, E., & Hatt, J. (2010) · Journal of Avian Medicine and Surgery · doi:10.1647/2008-060.1 · Cited by 5
“8) in healthy subjects of various species.(21) The EBC pH has been reported to decrease by .”
BackgroundBiomarkers of adult asthma and personalized medicine
Sim, D. W., & Lee, J. (2016) · Allergy Asthma & Respiratory Disease · doi:10.4168/aard.2016.4.1.4 · Cited by 4
Incremento de interleucina-6 (IL-6) en condensado de aire exhalado de niños asmáticos
Linares-Segovia, B., Sandoval, G. C., & Pacheco, F. D. R. E. (2016) · Archivos de Bronconeumología · doi:10.1016/j.arbres.2016.06.008 · Cited by 4
Serum but not exhaled breath condensate periostin level is increased in competitive athletes
Kurowski, M. M., Jurczyk, J., Jarzębska, M., Wardzyńska, A., Krysztofiak, H., & Kowalski, M. L. (2018) · The Clinical Respiratory Journal · doi:10.1111/crj.12759 · Cited by 4
“EBC samples were obtained using a Turbo DECCS (Disposable Exhaled Condensate Collection System) 09 device (Medivac di Romei Vanna, Parma, Italy) immediately before and 30 minutes after exercise challenge in accordance with the current recommendations.(18,19) Exhaled air entered and left the chamber through one-way val…”
MethodSilva, D., Moreira, R., Sokhatska, O., Beltrão, M., Montanha, T., García-Larsen, V., Villegas, R., Severo, M., Pizarro, A. I. N., Pinto, M., et al. (2018) · Contemporary Clinical Trials Communications · doi:10.1016/j.conctc.2018.05.010 · Cited by 4
Exhaled breath condensate and aerosol
Davis, M. D. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-819967-1.00007-4 · Cited by 4
Olarve, R. S., Torre, H. M. D., Foronda, J. R. F., Santos, M., SAJOR, N. J. B., Lopez, T. B. G., Haygood, K. J. F., & Santos, G. N. C. (2021) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2015/1/012102 · Cited by 4
“However, many of the VOC detected in exhaled breath are endogenous substances that originate from the physiological processes that occur in the body such as pentanal, hexanal, octanal, and nonanal [3,4,5].”
BackgroundMetabolomics in Exhaled Breath Condensates
Carraro, S., gualbert, G. C., Reniero, F., Giordano, G., & Baraldi, E. (2008) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.177.2.236a · Cited by 4
Biomarkers in allergic asthma: Which matrix should we use?
Maniscalco, M., & Motta, A. (2017) · Clinical & Experimental Allergy · doi:10.1111/cea.12978 · Cited by 4
“EBC is mainly (>99%) formed by water vapour, but also contains aerosol particles in which several biomolecules, including leukotrienes, 8-isoprostane, prostaglandins, hydrogen peroxide, nitric oxide-derived products and hydrogen ions, can be detected.(7) It is expected that airway surface liquid becomes aerosolized du…”
BackgroundIyer, M. (2018) · RIT Scholar Works (Rochester Institute of Technology) · Cited by 5
Maniscalco, M., Fuschillo, S., Candia, C., Corso, G., Paris, D., & Motta, A. (2025) · Journal of Breath Research · doi:10.1088/1752-7163/ae2f95 · Cited by 3
“The ratio of concentration of non-volatile compounds in EBC and the concentration of non-volatile compounds in ALF is often used as an indicator of the degree of EBC dilution, and can vary between 1000 and 50 000 [49].”
Die Rolle von Viren bei tiefen Atemwegsinfektionen des Erwachsenen
Ott, S. R., Lepper, P., Hauptmeier, B., Bals, R., Pletz, M. W., Schumann, C., Steininger, C., Kleines, M., & Geerdes-Fenge, H. F. (2009) · Pneumologie · doi:10.1055/s-0029-1215232 · Cited by 3
Xiong, H., Sun, J., Xue, Y., Yu, W., Zhou, Y. G., Wan, H., & Wang, P. (2022) · IEEE International Symposium on Olfaction and Electronic Nose (ISOEN) · doi:10.1109/isoen54820.2022.9789634 · Cited by 3
Early Diagnosis of Bronchopulmonary Dysplasia with E-Nose: A Pilot Study in Preterm Infants
Tenero, L., Piazza, M., Sandri, M. F., Ferrante, G., Giacomello, E., Ficial, B., Zaffanello, M., Biban, P., & PIACENTINI, G. L. (2024) · Sensors · doi:10.3390/s24196282 · Cited by 4
“The sample integrity was further preserved by placing the EBC cooling trap in an ice bath and applying it to the container dedicated to EBC collection, as illustrated by Hunt and Kononikhin [16,21,22].”
Method
Metadata
- Authors
- Horváth, I., Hunt, J., & Barnes, P. J.
- Affiliations
- Országos Korányi Tbc és Pulmonológiai Intézet (HU)
- University of Virginia (US)
- Institute of Cancer Research (GB)
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2005-09
- Volume
- 26
- Issue
- 3
- Pages
- 523-548
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W1989935661
- Cited by
- 1,284
- References
- 280
- Citations by year
- 2026: 43 · 2025: 28 · 2024: 35 · 2023: 30 · 2022: 51 · 2021: 43 · 2020: 47 · 2019: 50 · 2018: 53 · 2017: 61 · 2016: 60 · 2015: 68 · 2014: 76 · 2013: 82 · 2012: 107
- FWCI
- 48.86
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- European Respiratory Journal (publishedVersion)
- PubMed (publishedVersion)
- Research Publications (Maastricht University) (publishedVersion, other-oa)
- Publikationsdatenbank der Fraunhofer-Gesellschaft (Fraunhofer-Gesellschaft) (submittedVersion)
- Fraunhofer-Publica (Fraunhofer-Gesellschaft) (submittedVersion)
- Radboud Repository (Radboud University) (submittedVersion)
- OpenAgrar (submittedVersion)
- Padua Research Archive (University of Padova) (submittedVersion)
- Research Publications (Maastricht University) (submittedVersion, other-oa)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Chemical Sensor Technologies
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Asthma and respiratory diseases
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Chronic Obstructive Pulmonary Disease (COPD) Research
- Keywords
- exhaled breath condensate, adenosine, hydrogen peroxide, isoprostanes, leukotrienes, nitrogen oxides, cytokines, reproducibility, longitudinal study, lung disease
- MeSH terms
- Breath Tests, Humans, Lung Diseases, Reproducibility of Results, Biomarkers, Oxidative Stress
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.