Exhaled breath condensate: methodological recommendations and unresolved questions
Open accessThe DOI matches its Crossref record; 281 of the 281 references it cites were found in a registry or an index.
Abstract
Collection of exhaled breath condensate (EBC) is a noninvasive method for obtaining samples from the lungs. EBC contains large number of mediators including adenosine, ammonia, hydrogen peroxide, isoprostanes, leukotrienes, nitrogen oxides, peptides and cytokines. Concentrations of these mediators are influenced by lung diseases and modulated by therapeutic interventions. Similarly EBC pH also changes in respiratory diseases. The aim of the American Thoracic Society/European Respiratory Society Task Force on EBC was to identify the important methodological issues surrounding EBC collection and assay, to provide recommendations for the measurements and to highlight areas where further research is required. Based on the currently available evidence and the consensus of the expert panel for EBC collection, the following general recommendations were put together for oral sample collection: collect during tidal breathing using a noseclip and a saliva trap; define cooling temperature and collection time (10 min is generally sufficient to obtain 1–2 mL of sample and well tolerated by patients); use inert material for condenser; do not use resistor and do not use filter between the subject and the condenser. These are only general recommendations and certain circumstances may dictate variation from them. Important areas for future research involve: ascertaining mechanisms and site of exhaled breath condensate particle formation; determination of dilution markers; improving reproducibility; employment of EBC in longitudinal studies; and determining the utility of exhaled breath condensate measures for the management of individual patients. These studies are required before recommending this technique for use in clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“EBC was obtained approximately 70 min before swimming began and 35 min after swimming ended using an EcoScreen condenser (Jaeger GmbH, Würzburg, Germany) following American Thoracic Society/European Respiratory Society Task Force recommendations (Horvath et al. 2005).”
From Short-Term Changes in Respiratory Biomarkers after Swimming in a Chlorinated Pool (2010) · cites this paper as Horvath et al. 2005
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Brainard, D. H. (1997) · Spatial Vision · doi:10.1163/156856897x00357 · Cited by 19,702
The VideoToolbox software for visual psychophysics: transforming numbers into movies
Pelli, D. G. (1997) · Spatial Vision · doi:10.1163/156856897x00366 · Cited by 11,098
Mixed-Effects Models in S and S-PLUS
(2001) · Technometrics · doi:10.1198/tech.2001.s574 · Cited by 9,278
Best Linear Unbiased Estimation and Prediction under a Selection Model
Henderson, C. R. (1975) · Biometrics · doi:10.2307/2529430 · Cited by 2,497
Metabonomics: a platform for studying drug toxicity and gene function
Nicholson, J. K., Connelly, J., Lindon, J. C., & Holmes, E. (2002) · Nature Reviews Drug Discovery · doi:10.1038/nrd728 · Cited by 1,914
Nonlinear Mixed Effects Models for Repeated Measures Data
Lindstrom, M. J., & Bates, D. M. (1990) · Biometrics · doi:10.2307/2532087 · Cited by 1,795
That BLUP is a Good Thing: The Estimation of Random Effects
Robinson, G. K. (1991) · Statistical Science · doi:10.1214/ss/1177011926 · Cited by 1,686
Effects of antioxidant enzymes in the molecular control of reactive oxygen species toxicology
Matés, >. M. (2000) · Toxicology · doi:10.1016/s0300-483x(00)00306-1 · Cited by 1,518
Peroxynitrite-mediated tyrosine nitration catalyzed by superoxide dismutase
Ischiropoulos, H., Zhu, L., Chen, J., Tsai, M., Martin, J. C., Smith, C. D., & Beckman, J. S. (1992) · Archives of Biochemistry and Biophysics · doi:10.1016/0003-9861(92)90431-u · Cited by 1,495
Research works printed but not linked: 40
- 2002, Am J Respir Crit Care Med, 65, 663
- 1999, Eur Respir Rev, 68, 246
- 1985, Am Rev Respir Dis, 131, 894
- 2002, Eur J Med Res, 7, 353
- 2003, Eur J Med Res, 8, 505
- 1998, Monaldi Arch Chest Dis, 53, 268
- 1999, Eur Respir J, 14, 245
- 10.1002/1615-9861(200206)2:6<690::aid-prot690>3.0.co;2-6 · doi:10.1002/1615-9861(200206)2:6<690::aid-prot690>3.0.co;2-6
- 2000, Monaldi Arch Chest Dis, 55, 185
- 2003, Clin Lab, 49, 637
- 1997, Eur Respir J, 10, 1231
- 1986, Lancet, I, 11
- 1993, Anesth Analg, 77, 963
- 2003, Physiol Res, 52, 327
- 1995, Lancet, 346, 1235
- 10.1053/rmed.2001.1117 · DOI
- 1993, J Pharmacol Exp Ther, 267, 1529
- 1993, Am Rev Respir Dis, 15, 161
- 2002, Int Marit Health, 53, 93
- 1995, Appl Cardiopulmon Pathophysiol, 5, 215
- 10.1164/rccm.200206-507oc · DOI · Paper page
- 2003, Am J Respir Crit Care Med, 167, 91
- 2002, Int J Biol Markers, 17, 141
- 2001, J Heart Lung Transplant, 20, 184
- 1998, Pneumologie, 52, 426
- 2002, Eur J Med Res, 7, 290
- 2002, Curr Opin Pulm Med, 1, 25
- 2002, Int J Occup Med Environ Health, 15, 317
- 2003, Am J Respir Crit Care Med, 168, 1129
- 2004, Undersea Hyperb Med, 31, 217
- 2004, Physiol Res, 53, 561
- 2004, J Chromatogr B Analyt Technol Biomed Life Sci, 809, 199, 10.1016/s1570-0232(04)00513-6 · doi:10.1016/s1570-0232(04)00513-6
- 10.1007/s00408-004-2506-3 · DOI
- 10.1136/vr.155.23.744 · doi:10.1136/vr.155.23.744
- 2004, Thorax, 59, 1005
- 10.1002/rcm.1682 · DOI
- 2004, Physiol Res, 53, 561
- 10.1016/j.jfms.2003.12.002 · DOI
- 2004, Environ Health Perspect, 112, 1293, 10.1289/ehp.7108 · DOI
- 10.1016/s0956-5663(02)00083-0 · DOI · Paper page
Cited by
Reddel, H. K., Taylor, D. R., Bateman, E. D., Boulet, L.-P., Boushey, H. A., Busse, W. W., Casale, T. B., Chanez, P., Enright, P. L., Gibson, P. G., et al. (2009) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200801-060st · Cited by 1,918
“Methodologic aspects of EBC collection and analysis have been reviewed by an ERS working party (258).”
MethodOutcomes for COPD pharmacological trials: from lung function to biomarkers
Cazzola, M., MacNee, W., Martinez, F. J., Rabe, K. F., Franciosi, L. G., Barnes, P. J., Brusasco, V., Burge, P. S., Calverley, P. M. A., Celli, B. R., et al. (2008) · European Respiratory Journal · doi:10.1183/09031936.00099306 · Cited by 858
Self-citationA European Respiratory Society technical standard: exhaled biomarkers in lung disease
Horváth, I., Barnes, P. J., Loukides, S., Sterk, P. J., Högman, M., Olin, A.-C., Amann, A., Antus, B., Baraldi, E., Bikov, A., et al. (2017) · European Respiratory Journal · doi:10.1183/13993003.00965-2016 · Cited by 638
Self-citationDiagnosis and treatment of asthma in childhood: a PRACTALL consensus report
Bacharier, L. B., Boner, A., Carlsen, K. ‐., Eigenmann, P. A., Frischer, T., Götz, M., Helms, P. J., Hunt, J., Liu, A., Papadopoulos, N., et al. (2008) · Allergy · doi:10.1111/j.1398-9995.2007.01586.x · Cited by 640
“However, this method has not yet been fully validated and cannot be recommended in routine clinical practice for assessing airway inflammation (292).”
MethodSelf-citationDiagnosis and Management of Work-Related Asthma
Tarlo, S. M., Balmes, J., Balkissoon, R., Beach, J., Beckett, W., Bernstein, D., Blanc, P. D., Brooks, S. M., Cowl, C. T., Daroowalla, F., et al. (2008) · Chest · doi:10.1378/chest.08-0201 · Cited by 547
A novel peptide CXCR ligand derived from extracellular matrix degradation during airway inflammation
Weathington, N. M., van Houwelingen, A. H., Noerager, B. D., Jackson, P. L., Kraneveld, A. D., Galin, F. S., Folkerts, G., Nijkamp, F. P., & Blalock, J. E. (2006) · Nature Medicine · doi:10.1038/nm1361 · Cited by 496
“Future longitudinal studies in humans for multiple PGP-related peptides, perhaps with breath-condensate sample”
BackgroundExacerbations of chronic obstructive pulmonary disease
Celli, B. R., & Barnes, P. J. (2007) · European Respiratory Journal · doi:10.1183/09031936.00109906 · Cited by 462
Self-citationThe Mechanism of Breath Aerosol Formation
Johnson, G. R., & Morawska, L. (2009) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2008.0720 · Cited by 434
Malondialdehyde as a Potential Oxidative Stress Marker for Allergy-Oriented Diseases: An Update
Cordiano, R., Di Gioacchino, M., Mangifesta, R., Panzera, C., Gangemi, S., & Minciullo, P. L. (2023) · Molecules · doi:10.3390/molecules28165979 · Cited by 432
Solid-state gas sensors for breath analysis: A review
Di Natale, C., Paolesse, R., Martinelli, E., & Capuano, R. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.03.014 · Cited by 365
Liu, L., Poon, R., Chen, L., Frescura, A.-M., Montuschi, P., Ciabattoni, G., Wheeler, A., & Dales, R. (2009) · Environmental Health Perspectives · doi:10.1289/ehp.11813 · Cited by 354
Clinical Application of Volatile Organic Compound Analysis for Detecting Infectious Diseases
Sethi, S., Nanda, R., & Chakraborty, T. (2013) · Clinical Microbiology Reviews · doi:10.1128/cmr.00020-13 · Cited by 331
Breath Analysis in Disease Diagnosis: Methodological Considerations and Applications
Lourenço, C., & Turner, C. (2014) · Metabolites · doi:10.3390/metabo4020465 · Cited by 314
“In 2005, recommendations were also published for exhaled breath condensate sampling and analysis [89].”
Sample normalization methods in quantitative metabolomics
Wu, Y., & Li, L. (2016) · Journal of Chromatography A · doi:10.1016/j.chroma.2015.12.007 · Cited by 280
Pulmonary Biomarkers in Chronic Obstructive Pulmonary Disease
Barnes, P. J., Chowdhury, B., Kharitonov, S. A., Magnussen, H., Page, C. P., Postma, D., & Saetta, M. (2006) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200510-1659pp · Cited by 298
Self-citationOverview of the Mechanisms of Oxidative Stress: Impact in Inflammation of the Airway Diseases
Albano, G. D., Gagliardo, R. P., Montalbano, A. M., & Profita, M. (2022) · Antioxidants · doi:10.3390/antiox11112237 · Cited by 256
“EBC is a helpful method used to identify OS products found in the airways [112].”
MethodRecent advances in wide bandgap semiconductor biological and gas sensors
Pearton, S. J., Ren, F., Wang, Y.-L., Chu, B. H., Chen, K. H., Chang, C. Y., Lim, W., Lin, J., & Norton, D. P. (2010) · Progress in Materials Science · doi:10.1016/j.pmatsci.2009.08.003 · Cited by 286
Application of ’omics technologies to biomarker discovery in inflammatory lung diseases
Wheelock, C. E., Goss, V. M., Balgoma, D., Nicholas, B., Brandsma, J., Skipp, P. J., Snowden, S., Burg, D., D'Amico, A., Horvath, I., et al. (2013) · European Respiratory Journal · doi:10.1183/09031936.00078812 · Cited by 272
Self-citationCollection, particle sizing and detection of airborne viruses
Pan, M., Lednicky, J. A., & Wu, C. ‐. (2019) · Journal of Applied Microbiology · doi:10.1111/jam.14278 · Cited by 261
“The exhaled breath condensate (EBC) is another condensation-based device used for sampling influenza A H3N2 virus (Horvath et al. 2005; Xu et al. 2012).”
MethodExhaled biomarkers in lung cancer
Horváth, I., Lázár, Z., Gyulai, N., Kollai, M., & Losonczy, G. (2009) · European Respiratory Journal · doi:10.1183/09031936.00142508 · Cited by 268
Self-citationWesthoff, M., Litterst, P., Freitag, L., Urfer, W., Bader, S., & Baumbach, J.-I. (2009) · Thorax · doi:10.1136/thx.2008.099465 · Cited by 260
“Horvath et al , 1 who summarised the general requirements for breath analysis in the recommendations of the American Thoracic Society/European Respiratory Society (ATS/ERS), concluded that the ideal test should produce a ‘‘breathogram’’.”
BackgroundHuang, W., Wang, G., Lu, S.-E., Kipen, H., Wang, Y., Hu, M., Lin, W., Rich, D., Ohman-Strickland, P., Diehl, S. R., et al. (2012) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201205-0850oc · Cited by 251
“It is important to recognize some fundamental limitations of the EBC approach (32, 60).”
BackgroundMethodClinical use of exhaled volatile organic compounds in pulmonary diseases: a systematic review
van de Kant, K. D., van der Sande, L. J., Jöbsis, Q., van Schayck, O. C., & Dompeling, E. (2012) · Respiratory Research · doi:10.1186/1465-9921-13-117 · Cited by 252
“Thirdly, more insight is needed in the physiological meaning and biochemical origin of endogenous formed VOCs.”
BackgroundBarraza-Villarreal, A., Sunyer, J., Hernandez-Cadena, L., Escamilla-Nuñez, M. C., Sienra-Monge, J. J., Ramírez-Aguilar, M., Cortez-Lugo, M., Holguin, F., Diaz-Sánchez, D., Olin, A. C., et al. (2008) · Environmental Health Perspectives · doi:10.1289/ehp.10926 · Cited by 243
“Samples were obtained following the ATS/ERS (European Respiratory Society) Task Force recommenda tions (Horvath et al. 2005; Hunt 2002).”
MethodMetabolomics Applied to Exhaled Breath Condensate in Childhood Asthma
Carraro, S., Rezzi, S., Reniero, F., Héberger, K., Giordano, G., Zanconato, S., Guillou, C., & Baraldi, E. (2007) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200606-769oc · Cited by 242
Oxidative Stress in COPD: Sources, Markers, and Potential Mechanisms
McGuinness, A., & Sapey, E. (2017) · Journal of Clinical Medicine · doi:10.3390/jcm6020021 · Cited by 243
“Albumin is the most abundant protein in serum, whilst glutathione levels in alveolar lining fluid is approximately 140 times higher than in blood in healthy individuals [42] and these high extracellular levels are required in order to protect against the potential for damage offered by ROS.”
BackgroundMethodMaier, D., Laubender, E., Basavanna, A., Schumann, S., Güder, F., Urban, G. A., & Dincer, C. (2019) · ACS Sensors · doi:10.1021/acssensors.9b01403 · Cited by 233
A smart mask for exhaled breath condensate harvesting and analysis
Heng, W., Yin, S., Min, J., Wang, C., Han, H., Shirzaei Sani, E., Li, J., Song, Y., Rossiter, H. B., & Gao, W. (2024) · Science · doi:10.1126/science.adn6471 · Cited by 208
Does Chronic Microaspiration Cause Idiopathic Pulmonary Fibrosis?
Lee, J. S., Collard, H. R., Raghu, G., Sweet, M. P., Hays, S. R., Campos, G. M., Golden, J. A., & King, T. E. (2010) · The American Journal of Medicine · doi:10.1016/j.amjmed.2009.07.033 · Cited by 209
Xing, R., Xu, L., Song, J., Zhou, C., Li, Q., Liu, D., & Wei Song, H. (2015) · Scientific Reports · doi:10.1038/srep10717 · Cited by 211
Toward clinically applicable biomarkers for asthma: An EAACI position paper
Diamant, Z., Vijverberg, S., Alving, K., Bakirtas, A., Bjermer, L., Custovic, A., Dahlen, S., Gaga, M., Gerth van Wijk, R., Del Giacco, S., et al. (2019) · Allergy · doi:10.1111/all.13806 · Cited by 201
Popov, T. A. (2011) · Annals of Allergy, Asthma & Immunology · doi:10.1016/j.anai.2011.02.016 · Cited by 206
Exhaled Breath Condensate: An Overview
Hunt, J. (2007) · Immunology and Allergy Clinics of North America · doi:10.1016/j.iac.2007.09.001 · Cited by 201
“Certain biomarkers are seemingly best collected under set condensation conditions, but these conditions are markedly different for various biomarkers(11).”
BackgroundMethodInfluentialSelf-citationThe clinical potential of exhaled breath analysis for diabetes mellitus
Minh, T. D. C., Blake, D. R., & Galassetti, P. R. (2012) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2012.02.006 · Cited by 200
“Additionally, direct measurements of compounds in EBC is now possible[87]; typically, exhaled breath is trapped in a collection tube, cooled to an aqueous form, and analyzed by various chromatographic techniques[3].”
BackgroundMethodInfluentialBaker, E. H., Clark, N., Brennan, A. L., Fisher, D. A., Gyi, K. M., Hodson, M. E., Philips, B. J., Baines, D. L., & Wood, D. M. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01425.2006 · Cited by 200
“combined task force acknowledged desirability of correction for dilution but concluded that it was unlikely that changes in condensate mediator concentrations in inflammatory lung disease were completely explained by differences in dilution (13).”
Kubáň, P., & Foret, F. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.07.049 · Cited by 194
Current Status of Methods and Techniques for Breath Analysis
Cao, W., & Duan, Y. (2007) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408340600976499 · Cited by 191
The dynamics of SARS-CoV-2 infectivity with changes in aerosol microenvironment
Oswin, H. P., Haddrell, A. E., Otero-Fernandez, M., Mann, J. F. S., Cogan, T. A., Hilditch, T. G., Tian, J., Hardy, D. A., Hill, D. J., Finn, A., et al. (2022) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2200109119 · Cited by 179
Exhaled breath analysis: Novel approach for early detection of lung cancer
Chan, H. P., Lewis, C., & Thomas, P. S. (2009) · Lung Cancer · doi:10.1016/j.lungcan.2008.05.020 · Cited by 183
Sputum Proteomics in Inflammatory and Suppurative Respiratory Diseases
Gray, R. D., MacGregor, G., Noble, D., Imrie, M., Dewar, M., Boyd, A. C., Innes, J. A., Porteous, D. J., & Greening, A. P. (2008) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200703-409oc · Cited by 178
Kirwan, J. A., Brennan, L., Broadhurst, D., Fiehn, O., Cascante, M., Dunn, W. B., Schmidt, M. A., & Velagapudi, V. (2018) · Clinical Chemistry · doi:10.1373/clinchem.2018.287045 · Cited by 170
“For exhaled breath condensate, the American Thoracic Society and the European Respiratory Society published a list of guidelines in 2005 (147) on the collection of this type of specimen.”
BackgroundKomakula, S., Khatri, S., Mermis, J., Savill, S., Haque, S., Rojas, M., Brown, L., Teague, G. W., & Holguin, F. (2007) · Respiratory Research · doi:10.1186/1465-9921-8-32 · Cited by 178
“Seventh, our study is limited by determining airway oxidation stress using 8-isoprostanes using a commercial EIA kit which, although this method is highly specific and has been validated by gas chromatography, there have been contradictory results in the reproducibility of this essay [51].”
MethodAnalysis of breath, exhaled via the mouth and nose, and the air in the oral cavity
Wang, T., Pysanenko, A., Dryahina, K., Španěl, P., & Smith, D. (2008) · Journal of Breath Research · doi:10.1088/1752-7155/2/3/037013 · Cited by 164
Bartoli, M. L., Novelli, F., Costa, F., Malagrinò, L., Melosini, L., Bacci, E., Cianchetti, S., Dente, F. L., Di Franco, A., Vagaggini, B., et al. (2011) · Mediators of Inflammation · doi:10.1155/2011/891752 · Cited by 160
“We checked storage stability of EBC samples, just in few samples showing a good repeatability; however, we analyzed all samples within 6 months from the collection, as suggested by the international recommendations and previous papers [5, 9, 11].”
MethodComparison of Biomarkers in Exhaled Breath Condensate and Bronchoalveolar Lavage
Jackson, A. S., Sandrini, A., Campbell, C., Chow, S., Thomas, P. S., & Yates, D. H. (2007) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200601-107oc · Cited by 159
“EBC samples a larger portion of the respiratory tract than BAL, including the alveolar lining fluid and fluid derived from the larger airways ( 8 ).”
BackgroundMethodInfluentialExhaled Breath Condensate: Technical and Diagnostic Aspects
Konstantinidi, E. M., Lappas, A. S., Tzortzi, A., & BEHRAKIS, P. K. (2015) · The Scientific World JOURNAL · doi:10.1155/2015/435160 · Cited by 175
“Exercise withdrawal is recommended 1 hour prior to the sample collection, since it may be responsible for changes in EBC compounds concentration [1].”
BackgroundMethodInfluentialMontuschi, P. (2007) · Therapeutic Advances in Respiratory Disease · doi:10.1177/1753465807082373 · Cited by 158
Pijnenburg, M. W., Baraldi, E., Brand, P. L. P., Carlsen, K.-H., Eber, E., Frischer, T., Hedlin, G., Kulkarni, N., Lex, C., Mäkelä, M. J., et al. (2015) · European Respiratory Journal · doi:10.1183/09031936.00088814 · Cited by 148
Mutti, A., Corradi, M., Goldoni, M., Vettori, M. V., Bernard, A., & Apostoli, P. (2006) · Chest · doi:10.1378/chest.129.5.1288 · Cited by 157
Self-citationWeisel, C. P., Richardson, S. D., Nemery, B., Aggazzotti, G., Baraldi, E., Blatchley, E. R., Blount, B. C., Carlsen, K.-H., Eggleston, P. A., Frimmel, F. H., et al. (2009) · Environmental Health Perspectives · doi:10.1289/ehp.11513 · Cited by 153
“The technique is safe and easy to perform even for children as young as 4 years of age, but its relationship to asthma, pre-asthma conditions, or early-stage changes that may or may not lead to asthma has not been validated (Horvath et al. 2005).”
BackgroundSelf-citationMontuschi, P., Paris, D., Melck, D. J., Lucidi, V., Ciabattoni, G., Raia, V., Calabrese, C., Bush, A., Barnes, P. J., & Motta, A. (2011) · Thorax · doi:10.1136/thoraxjnl-2011-200072 · Cited by 152
Self-citationHealth surveillance study of workers who manufacture multi-walled carbon nanotubes
Lee, J. S., Choi, Y. C., Shin, J. H., Lee, J. H., Lee, Y., Park, S., Baek, J. E., Park, J. D., Ahn, K., & Yu, I. J. (2014) · Nanotoxicology · doi:10.3109/17435390.2014.978404 · Cited by 159
“The pulmonary function test (PFT) was performed in accordance with the international guidelines provided by the American Thoracic Society (ATS) and European Respiratory Society (ERS) using a 1022 digital spirometer (SensorMedics, San Diego, CA) (Brusasco et al., 2005).”
MethodRecent developments in wearable breath sensors for healthcare monitoring
Kim, D., Lee, J., Park, M. K., & Ko, S. H. (2024) · Communications Materials · doi:10.1038/s43246-024-00480-w · Cited by 157
“the exhaled breath, collection methods like exhaled breath condensate (EBC) and associated exhaled breath aerosol (EBA) sampling have gained attention for retrieving SVOCs, proteins, lipids, DNA, bacteria, and viruses from the lower airways 1,14 .”
Rapid Flu Diagnosis Using Silicon Nanowire Sensor
Shen, F., Wang, J., Xu, Z., Wu, Y. H., Chen, Q., Li, X., Xu, J., Li, L., Yao, M., Guo, X., et al. (2012) · Nano Letters · doi:10.1021/nl301516z · Cited by 149
Biomarkers in asthma: state of the art
Tiotiu, A. I. (2018) · Asthma Research and Practice · doi:10.1186/s40733-018-0047-4 · Cited by 161
Monitoring asthma in childhood: lung function, bronchial responsiveness and inflammation
Mœller, A., Carlsen, K., Sly, P. D., Baraldi, E., PIACENTINI, G. L., Pavord, I. D., Lex, C., & Saglani, S. (2015) · European Respiratory Review · doi:10.1183/16000617.00003914 · Cited by 163
Romieu, I., Barraza‐Villarreal, A., Escamilla-Núñez, C., Almstrand, A., Díaz-Sánchez, D., Sly, P. D., & Olin, A. (2008) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2007.12.004 · Cited by 155
Applicability of non-invasively collected matrices for human biomonitoring
Smolders, R., Schramm, K., Nickmilder, M., & Schoeters, G. E. R. (2009) · Environmental Health · doi:10.1186/1476-069x-8-8 · Cited by 153
“These methods are generally well validated and documented, as are the measurement techniques [97].”
MethodExhaled markers of oxidative stress in idiopathic pulmonary fibrosis
Psathakis, K., Mermigkis, D., Papatheodorou, G., Loukides, S., Panagou, P., Polychronopoulos, V., Siafakas, N. M., & Bouros, D. (2006) · European Journal of Clinical Investigation · doi:10.1111/j.1365-2362.2006.01636.x · Cited by 136
Metabolomics in Sleep, Insomnia and Sleep Apnea
Humer, E. C., Pieh, C., & Brandmayr, G. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21197244 · Cited by 151
“Organic compounds comprise of amino acids and their derivatives, peptides, proteins, urea, organic acids, surfactants and macromolecules [46].”
BackgroundCardiovascular Biomarkers in Exhaled Breath
Cikach, F. S., & Dweik, R. A. (2012) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2012.05.005 · Cited by 137
“Aerosolized droplets in exhaled breath can be captured by a variety of methods and analyzed for a wide range of biomarkers from metabolic end products to proteins to a variety of cytokines and chemokines and the possibilities continue to expand.(69) A major hurdle that faced this field as it transitions from the labor…”
Exhaled breath condensate biomarkers in COPD
Borrill, Z., Roy, K. C., & Singh, D. (2008) · European Respiratory Journal · doi:10.1183/09031936.00116107 · Cited by 143
Laurentiis, G. D., Paris, D., Melck, D. J., Maniscalco, M., Marsico, S. A., Corso, G., Motta, A., & Sofia, M. (2008) · European Respiratory Journal · doi:10.1183/09031936.00072408 · Cited by 136
Electrical detection of biomaterials using AlGaN/GaN high electron mobility transistors
Kang, B. S., Wang, H. T., Ren, F., & Pearton, S. J. (2008) · Journal of Applied Physics · doi:10.1063/1.2959429 · Cited by 142
Asthma severity in childhood and metabolomic profiling of breath condensate
Carraro, S., Giordano, G., Reniero, F., Carpi, D., Stocchero, M., Sterk, P. J., & Baraldi, E. (2012) · Allergy · doi:10.1111/all.12063 · Cited by 134
“EBC is a biofluid collected noninvasively by cooling the air expired during tidal breathing, and it provides information on pathological processes involving the lung (14).”
BackgroundConrad, D. H., Goyette, J., & Thomas, P. S. (2007) · Journal of General Internal Medicine · doi:10.1007/s11606-007-0411-1 · Cited by 134
Bikov, A., Lázár, Z., & Horvath, I. (2015) · Journal of Breath Research · doi:10.1088/1752-7155/9/3/034001 · Cited by 127
“Various water-soluble inflammatory mediators such as 8-isoprostane can be measured in EBC and correlated with clinical variables [133, 134].”
BackgroundSelf-citationNoninvasive methods for assessment of airway inflammation in occupational settings
Quirce, S., Lemière, C., Frederic de, B. L. A. Y., del Pozo, V., van Wijk, R. G., Maestrelli, P., Pauli, G., Pignatti, P., Raulf‐Heimsoth, M., Sastre, J., et al. (2009) · Allergy · doi:10.1111/j.1398-9995.2009.02274.x · Cited by 148
Treatment of asthma with antileukotrienes: First line or last resort therapy?
Dahlén, S. (2006) · European Journal of Pharmacology · doi:10.1016/j.ejphar.2005.12.070 · Cited by 133
Wallace, M. A. G., & Pleil, J. D. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.01.069 · Cited by 137
Airway inflammation in chronic obstructive pulmonary disease.
Angelis, N., Porpodis, Κ., Zarogoulidis, P., Spyratos, D., Kioumis, I. P., Papaiwannou, A., Pitsiou, G., Tsakiridis, K., Mpakas, A., Arikas, S., et al. (2014) · PubMed · doi:10.3978/j.issn.2072-1439.2014.03.07 · Cited by 122
Detecting COVID-19 from Breath: A Game Changer for a Big Challenge
Giovannini, G., Haick, H., & Garoli, D. (2021) · ACS Sensors · doi:10.1021/acssensors.1c00312 · Cited by 131
Recommendations for epidemiological studies on COPD
Bakke, P. S., Rönmark, E., Eagan, T., Pistelli, F., Annesi‐Maesano, I., Maly, M., Meren, M., Vermeire, P. A., Vestbo, J., Viegi, G., et al. (2011) · European Respiratory Journal · doi:10.1183/09031936.00193809 · Cited by 143
The Acute Effects of Water-Pipe Smoking on the Cardiorespiratory System
Hakim, F., Hellou, E., Goldbart, A. D., Katz, R., Bentur, Y., & Bentur, L. (2010) · CHEST Journal · doi:10.1378/chest.10-1833 · Cited by 126
Janicka, M., Kot‐Wasik, A., Kot, J., & Namieśnik, J. (2010) · International Journal of Molecular Sciences · doi:10.3390/ijms11114631 · Cited by 125
“However, it is well known that multiple frosting-defrosting cycles could destroy some biomarkers like prostaglandins [52].”
BackgroundMethodInfluentialSchwarz, K., Biller, H., Windt, H., Koch, W., & Hohlfeld, J. M. (2010) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2009.0809 · Cited by 119
Short-Term Changes in Respiratory Biomarkers after Swimming in a Chlorinated Pool
Font-Ribera, L., Kogevinas, M., Zock, J.-P., Gómez, F. P., Barreiro, E., Nieuwenhuijsen, M. J., Fernandez, P., Lourencetti, C., Pérez-Olabarría, M., Bustamante, M., et al. (2010) · Environmental Health Perspectives · doi:10.1289/ehp.1001961 · Cited by 119
“EBC was obtained approximately 70 min before swimming began and 35 min after swimming ended using an EcoScreen condenser (Jaeger GmbH, Würzburg, Germany) following American Thoracic Society/European Respiratory Society Task Force recommendations (Horvath et al. 2005).”
Oyeniran, C., Sturgill, J., Hait, N. C., Huang, W., Avni, D., Maceyka, M. W., Newton, J. C., Allegood, J. C., Montpetit, A. J., Conrad, D. H., et al. (2015) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2015.02.031 · Cited by 125
Leukotriene modifiers for asthma treatment
Montuschi, P., & Peters‐Golden, M. L. (2010) · Clinical & Experimental Allergy · doi:10.1111/j.1365-2222.2010.03630.x · Cited by 112
Fu, Y., He, H., Zhao, T., Dai, Y., Han, W., Ma, J., Xing, L., Zhang, Y., & Xue, X. (2018) · Nano-Micro Letters · doi:10.1007/s40820-018-0228-y · Cited by 121
Exhaled breath analysis: the new frontier in medical testing
Dweik, R. A., & Amann, A. (2008) · Journal of Breath Research · doi:10.1088/1752-7163/2/3/030301 · Cited by 128
“Aerosolized droplets in exhaled breath can be captured by a variety of methods and analyzed for a wide range of biomarkers from metabolic end products to proteins to a variety of cytokines and chemokines, and the possibilities continue to expand [6].”
BackgroundSilkoff, P. E., ERZURUM, S. C., Lundberg, J. O., George, S. C., Marczin, N., Hunt, J. F., Effros, R. M., & Horváth, I. (2006) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200406-710st · Cited by 128
Self-citationExhaled breath biomarker sensing
Vasilescu, A., Hrinczenko, B. W., Swain, G. M., & Peteu, S. F. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113193 · Cited by 115
Evidence of unexpected oxidative stress in airways of adolescents born very pre-term
Filippone, M., Bonetto, G., Corradi, M., Frigo, A. C., & Baraldi, E. (2012) · European Respiratory Journal · doi:10.1183/09031936.00185511 · Cited by 119
“Despite some technical limitations, relating mainly to EBC dilution issues[34], recent literature supports its use as an indirect method for sampling the composition of the airway lining fluid[17,19,18,20,35].”
BackgroundMethodMatsunaga, K., Yanagisawa, S., Ichikawa, T., Ueshima, K., Akamatsu, K., Hirano, T., Nakanishi, M., Yamagata, T., Minakata, Y., & Ichinose, M. (2006) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2006.04.020 · Cited by 113
Recent developments and highlights in biomarkers in allergic diseases and asthma
Eguíluz‐Gracia, I., Tay, T. R., Hew, M. J., Escribese, M. M., Barber, D., O’Hehir, R. E., & Torres, M. J. (2018) · Allergy · doi:10.1111/all.13628 · Cited by 120
“a high degree of versatility, as it is applicable to a great variety of matrices, whose nature can be tailored to the disease of interest.(4,7) In chronic respiratory diseases, the metabolic analysis of exhaled”
BackgroundCzebe, K., Barta, I., Antus, B., Valyon, M., Horváth, I., & Kullmann, T. (2008) · Respiratory Medicine · doi:10.1016/j.rmed.2007.12.013 · Cited by 113
Self-citationThe effect of ambient air pollution on respiratory health of school children: a panel study
Epton, M. J., Dawson, R. D., Brooks, W. M., Kingham, S., Aberkane, T., Cavanagh, J.-A. E., Frampton, C. M., Hewitt, T., Cook, J. M., McLeod, S., et al. (2008) · Environmental Health · doi:10.1186/1476-069x-7-16 · Cited by 114
“The potential drawbacks of EBC analysis, including assay variability and very low biomarker concentration have been highlighted in a recent review article [42] and are addressed in the ATS/ERS taskforce position paper on EBC [43].”
MethodBreath condenser coatings affect measurement of biomarkers in exhaled breath condensate
Rosias, P. P. R., Robroeks, C. M. H. H. T., Niemarkt, H. J., Kester, A. D. M., Vernooy, J. H. J., Suykerbuyk, J., Teunissen, J., Heynens, J., Hendriks, H. J. E., Jöbsis, Q., et al. (2006) · European Respiratory Journal · doi:10.1183/09031936.06.00110305 · Cited by 121
Comparison of two methods for exhaled breath condensate collection
Soyer, O. U., Dizdar, E. A., Keskin, O., Lilly, C. M., & Kalaycı, Ö. (2006) · Allergy · doi:10.1111/j.1398-9995.2006.01064.x · Cited by 110
“There has been an increasing interest in the use of exhaled breath condensate (EBC) as a noninvasive method to investigate lung diseases (1, 2).”
BackgroundMethodOxidative stress and its determinants in the airways of children with asthma
Dut, R., Dizdar, E. A., Birben, E., Saçkesen, C., Soyer, O. U., Besler, H. T., & Kalaycı, Ö. (2008) · Allergy · doi:10.1111/j.1398-9995.2008.01766.x · Cited by 114
“Recently, there has been an increasing interest in the use of EBC as a noninvasive method to investigate the diseases of the airways (23, 24).”
MethodWearable respiratory sensors for health monitoring
Yin, Z., Yang, Y., Hu, C. F., Li, J., Qin, B., & Yang, X. (2024) · NPG Asia Materials · doi:10.1038/s41427-023-00513-9 · Cited by 115
“However, this lack of adoption does not detract from the potential of EBC analysis to address unmet medical needs and expand the portfolio of noninvasive testing for respiratory disease 168,175 – 178 .”
InfluentialExhaled breath condensate eicosanoid levels associate with asthma and its severity
Kazani, S. D., Planagumà, A., Ono, E., Bonini, M., Zahid, M., Marigowda, G., Wechsler, M. E., Levy, B. D., & Israel, E. (2013) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2013.01.058 · Cited by 108
Barreto, M., Villa, M. P., Olita, C., Martella, S., Ciabattoni, G., & Montuschi, P. (2008) · CHEST Journal · doi:10.1378/chest.08-0722 · Cited by 107
Sinues, P., & de la Mora, J. F. (2008) · Analytical Chemistry · doi:10.1021/ac801185e · Cited by 107
Exhaled breath condensate in intubated neonates- a window into the lung’s glutathione status
Rosso, M. I., Roark, S., Taylor, E., Ping, X., Ward, J. M., Roche, K. J., McCracken, C., Brown, L. A. S., & Gauthier, T. W. (2014) · Respiratory Research · doi:10.1186/1465-9921-15-1 · Cited by 106
“EBC was collected from the exhalation limb of the ventilator in intubated newborns which reduced possible contamination from volatiles in the atmosphere or the mouth as has been demonstrated in spontaneously breathing subjects [12-14].”
BackgroundMethodExhaled breath condensate: a comprehensive update
Ahmadzai, H., Huang, S., Hettiarachchi, R., Lin, J.-L., Thomas, P. S., & Zhang, Q. (2013) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2012-0593 · Cited by 115
“Ambient room air contains molecules, which can interact with EBC biomarkers through several mechanisms such as directly contributing to EBC, reacting with compounds present in EBC (thus altering or consuming biomarkers) or causing biochemical or inflammatory changes in the airways [ 1 ].”
InfluentialDavis, M. D., Montpetit, A. J., & Hunt, J. (2012) · Immunology and Allergy Clinics of North America · doi:10.1016/j.iac.2012.06.014 · Cited by 105
“First, despite EBC methodological recommendations set forth by an American Thoracic Society/European Respiratory Society task force in 2005, many investigators do not fully describe collection methods.(11) Second,”
InfluentialSelf-citationSeparating Smoking-Related Diseases Using NMR-Based Metabolomics of Exhaled Breath Condensate
de Laurentiis, G., Paris, D., Melck, D. J., Montuschi, P., Maniscalco, M., Bianco, A., Sofia, M., & Motta, A. (2013) · Journal of Proteome Research · doi:10.1021/pr301171p · Cited by 111
Exhaled breath condensate pH standardised for CO2partial pressure
Kullmann, T., Barta, I., Lázár, Z., Szili, B., Barát, E., Valyon, M., Kollai, M., & Horváth, I. (2006) · European Respiratory Journal · doi:10.1183/09031936.00084006 · Cited by 103
Self-citation
Metadata
- Authors
- Horváth, I., Hunt, J., & Barnes, P. J.
- Affiliations
- Országos Korányi Tbc és Pulmonológiai Intézet (HU)
- University of Virginia (US)
- Institute of Cancer Research (GB)
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2005-09
- Volume
- 26
- Issue
- 3
- Pages
- 523-548
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W1989935661
- Cited by
- 1,284
- References
- 280
- Citations by year
- 2026: 43 · 2025: 28 · 2024: 35 · 2023: 30 · 2022: 51 · 2021: 43 · 2020: 47 · 2019: 50 · 2018: 53 · 2017: 61 · 2016: 60 · 2015: 68 · 2014: 76 · 2013: 82 · 2012: 107
- FWCI
- 48.86
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- European Respiratory Journal (publishedVersion)
- PubMed (publishedVersion)
- Research Publications (Maastricht University) (publishedVersion, other-oa)
- Publikationsdatenbank der Fraunhofer-Gesellschaft (Fraunhofer-Gesellschaft) (submittedVersion)
- Fraunhofer-Publica (Fraunhofer-Gesellschaft) (submittedVersion)
- Radboud Repository (Radboud University) (submittedVersion)
- OpenAgrar (submittedVersion)
- Padua Research Archive (University of Padova) (submittedVersion)
- Research Publications (Maastricht University) (submittedVersion, other-oa)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Chemical Sensor Technologies
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Asthma and respiratory diseases
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Chronic Obstructive Pulmonary Disease (COPD) Research
- Keywords
- exhaled breath condensate, adenosine, hydrogen peroxide, isoprostanes, leukotrienes, nitrogen oxides, cytokines, reproducibility, longitudinal study, lung disease
- MeSH terms
- Breath Tests, Humans, Lung Diseases, Reproducibility of Results, Biomarkers, Oxidative Stress
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.