Exhaled breath condensate: methodological recommendations and unresolved questions
Open accessThe DOI matches its Crossref record; 281 of the 281 references it cites were found in a registry or an index.
Abstract
Collection of exhaled breath condensate (EBC) is a noninvasive method for obtaining samples from the lungs. EBC contains large number of mediators including adenosine, ammonia, hydrogen peroxide, isoprostanes, leukotrienes, nitrogen oxides, peptides and cytokines. Concentrations of these mediators are influenced by lung diseases and modulated by therapeutic interventions. Similarly EBC pH also changes in respiratory diseases. The aim of the American Thoracic Society/European Respiratory Society Task Force on EBC was to identify the important methodological issues surrounding EBC collection and assay, to provide recommendations for the measurements and to highlight areas where further research is required. Based on the currently available evidence and the consensus of the expert panel for EBC collection, the following general recommendations were put together for oral sample collection: collect during tidal breathing using a noseclip and a saliva trap; define cooling temperature and collection time (10 min is generally sufficient to obtain 1–2 mL of sample and well tolerated by patients); use inert material for condenser; do not use resistor and do not use filter between the subject and the condenser. These are only general recommendations and certain circumstances may dictate variation from them. Important areas for future research involve: ascertaining mechanisms and site of exhaled breath condensate particle formation; determination of dilution markers; improving reproducibility; employment of EBC in longitudinal studies; and determining the utility of exhaled breath condensate measures for the management of individual patients. These studies are required before recommending this technique for use in clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“EBC was obtained approximately 70 min before swimming began and 35 min after swimming ended using an EcoScreen condenser (Jaeger GmbH, Würzburg, Germany) following American Thoracic Society/European Respiratory Society Task Force recommendations (Horvath et al. 2005).”
From Short-Term Changes in Respiratory Biomarkers after Swimming in a Chlorinated Pool (2010) · cites this paper as Horvath et al. 2005
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Brainard, D. H. (1997) · Spatial Vision · doi:10.1163/156856897x00357 · Cited by 19,702
The VideoToolbox software for visual psychophysics: transforming numbers into movies
Pelli, D. G. (1997) · Spatial Vision · doi:10.1163/156856897x00366 · Cited by 11,098
Mixed-Effects Models in S and S-PLUS
(2001) · Technometrics · doi:10.1198/tech.2001.s574 · Cited by 9,278
Best Linear Unbiased Estimation and Prediction under a Selection Model
Henderson, C. R. (1975) · Biometrics · doi:10.2307/2529430 · Cited by 2,497
Metabonomics: a platform for studying drug toxicity and gene function
Nicholson, J. K., Connelly, J., Lindon, J. C., & Holmes, E. (2002) · Nature Reviews Drug Discovery · doi:10.1038/nrd728 · Cited by 1,914
Nonlinear Mixed Effects Models for Repeated Measures Data
Lindstrom, M. J., & Bates, D. M. (1990) · Biometrics · doi:10.2307/2532087 · Cited by 1,795
That BLUP is a Good Thing: The Estimation of Random Effects
Robinson, G. K. (1991) · Statistical Science · doi:10.1214/ss/1177011926 · Cited by 1,686
Effects of antioxidant enzymes in the molecular control of reactive oxygen species toxicology
Matés, >. M. (2000) · Toxicology · doi:10.1016/s0300-483x(00)00306-1 · Cited by 1,518
Peroxynitrite-mediated tyrosine nitration catalyzed by superoxide dismutase
Ischiropoulos, H., Zhu, L., Chen, J., Tsai, M., Martin, J. C., Smith, C. D., & Beckman, J. S. (1992) · Archives of Biochemistry and Biophysics · doi:10.1016/0003-9861(92)90431-u · Cited by 1,495
Research works printed but not linked: 40
- 2002, Am J Respir Crit Care Med, 65, 663
- 1999, Eur Respir Rev, 68, 246
- 1985, Am Rev Respir Dis, 131, 894
- 2002, Eur J Med Res, 7, 353
- 2003, Eur J Med Res, 8, 505
- 1998, Monaldi Arch Chest Dis, 53, 268
- 1999, Eur Respir J, 14, 245
- 10.1002/1615-9861(200206)2:6<690::aid-prot690>3.0.co;2-6 · doi:10.1002/1615-9861(200206)2:6<690::aid-prot690>3.0.co;2-6
- 2000, Monaldi Arch Chest Dis, 55, 185
- 2003, Clin Lab, 49, 637
- 1997, Eur Respir J, 10, 1231
- 1986, Lancet, I, 11
- 1993, Anesth Analg, 77, 963
- 2003, Physiol Res, 52, 327
- 1995, Lancet, 346, 1235
- 10.1053/rmed.2001.1117 · DOI
- 1993, J Pharmacol Exp Ther, 267, 1529
- 1993, Am Rev Respir Dis, 15, 161
- 2002, Int Marit Health, 53, 93
- 1995, Appl Cardiopulmon Pathophysiol, 5, 215
- 10.1164/rccm.200206-507oc · DOI · Paper page
- 2003, Am J Respir Crit Care Med, 167, 91
- 2002, Int J Biol Markers, 17, 141
- 2001, J Heart Lung Transplant, 20, 184
- 1998, Pneumologie, 52, 426
- 2002, Eur J Med Res, 7, 290
- 2002, Curr Opin Pulm Med, 1, 25
- 2002, Int J Occup Med Environ Health, 15, 317
- 2003, Am J Respir Crit Care Med, 168, 1129
- 2004, Undersea Hyperb Med, 31, 217
- 2004, Physiol Res, 53, 561
- 2004, J Chromatogr B Analyt Technol Biomed Life Sci, 809, 199, 10.1016/s1570-0232(04)00513-6 · doi:10.1016/s1570-0232(04)00513-6
- 10.1007/s00408-004-2506-3 · DOI
- 10.1136/vr.155.23.744 · doi:10.1136/vr.155.23.744
- 2004, Thorax, 59, 1005
- 10.1002/rcm.1682 · DOI
- 2004, Physiol Res, 53, 561
- 10.1016/j.jfms.2003.12.002 · DOI
- 2004, Environ Health Perspect, 112, 1293, 10.1289/ehp.7108 · DOI
- 10.1016/s0956-5663(02)00083-0 · DOI · Paper page
Cited by
Items 401–500 of 1,000
Stefanska, J., Sokołowska, M., Sarniak, A., Włodarczyk, A., Doniec, Z., Nowak, D., & Pawliczak, R. (2009) · Pulmonary Pharmacology & Therapeutics · doi:10.1016/j.pupt.2009.09.003 · Cited by 35
“Any material that might come in contact with EBC, including devices used for collection, processing and assaying EBC was thoroughly rinse with highly pure (distilled/de-ionised) water [7].”
BackgroundInfluentialAdenosine Triphosphate Concentration of Exhaled Breath Condensate in Asthma
Lázár, Z., Cervenak, L., Orosz, M., Gálffy, G., Komlósi, Z. I., Bikov, A., Losonczy, G., & Horváth, I. (2010) · CHEST Journal · doi:10.1378/chest.10-0085 · Cited by 35
Self-citationGarrod, R., Robson-Ansley, P. J., Canavan, J. L., & Jewell, A. (2006) · Medical Hypotheses · doi:10.1016/j.mehy.2006.07.028 · Cited by 41
Biomarkers in the assessment and management of airways diseases
Taylor, D. R., & Pavord, I. D. (2008) · Postgraduate Medical Journal · doi:10.1136/pgmj.2008.069864 · Cited by 36
“Exhaled breath condensate has attracted interest as a potential non-invasive means for assessing airway inflammation, but it is at an early stage of development and there are several unresolved methodological issues.(18) Whether markers of inflammation measured in exhaled air can provide important information that is…”
BackgroundZiętkowski, Z., Skiepko, R., Tomasiak, M. M., & Bodzenta‐Łukaszyk, A. (2007) · Respiratory Research · doi:10.1186/1465-9921-8-76 · Cited by 34
“ET-1 levels were measured in exhaled breath condensate (EBC), collecting by cooling exhaled air – noninvasive procedure, easily performed and effort independent, a rapid method for obtaining samples from the lower respiratory tract [10].”
BackgroundMethodExhaled Breath Condensate pH Is Increased after Moderate Exercise
Riediker, M., & Danuser, B. (2007) · Journal of Aerosol Medicine · doi:10.1089/jam.2006.0567 · Cited by 33
Calabrese, C., Tosco, A., Abete, P., Carnovale, V., Basile, C., Magliocca, A., Quattrucci, S., Sanctis, S. D., Alatri, F., Mazzarella, G., et al. (2014) · Journal of Cystic Fibrosis · doi:10.1016/j.jcf.2014.09.014 · Cited by 33
Canu, I. G., Crézé, C., Hemmendinger, M., Rayana, T. B., Besançon, S., Jouannique, V., Debatisse, A., Wild, P. P., Sauvain, J., Suárez, G., et al. (2021) · International Journal of Hygiene and Environmental Health · doi:10.1016/j.ijheh.2021.113837 · Cited by 40
Ko, F. W. S. (2008) · International Journal of COPD · doi:10.2147/copd.s4158 · Cited by 33
Zhang, S., Chen, Y., Riezk, A., Ming, D. K. Y., Tsvik, L., Sützl, L., Holmes, A. H., & O’Hare, D. (2022) · ACS Sensors · doi:10.1021/acssensors.2c01739 · Cited by 36
The role and regulation of microRNAs in asthma
Ariel, D., & Upadhyay, D. (2011) · Current Opinion in Allergy and Clinical Immunology · doi:10.1097/aci.0b013e32834ecb7f · Cited by 34
Kastelijn, E. A., Rijkers, G. T., van Moorsel, C. H. M., Zanen, P., Erp, J. M. K., van de Graaf, E. A., van Kessel, D. A., Grutters, J. C., & van den Bosch, J. M. M. (2010) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2010.04.013 · Cited by 33
Sinha, A., Krishnan, V., Sethi, T., Roy, S., Ghosh, B., Lodha, R., Kabra, S. K., & Agrawal, A. (2012) · European Respiratory Journal · doi:10.1183/09031936.00047711 · Cited by 33
Endothelin-1 in exhaled breath condensate of stable and unstable asthma patients
Ziętkowski, Z., Skiepko, R., Tomasiak, M. M., & Bodzenta‐Łukaszyk, A. (2007) · Respiratory Medicine · doi:10.1016/j.rmed.2007.10.013 · Cited by 33
“There has been increasing interest in measuring EBC—a very useful method, especially in the assessment of inflammatory mediators related to the bronchial epithelium, in the pathophysiology and evaluation of new strategies for the treatment of asthma.(5)”
MethodAlpha-1 antitrypsin is elevated in exhaled breath condensate and serum in exacerbated COPD patients
Koczulla, A. R., Noeske, S., Herr, C., Koepke, J., Jörres, R. A., Nell, C., Schmid, S., Vogelmeier, C. F., & Bals, R. (2011) · Respiratory Medicine · doi:10.1016/j.rmed.2011.06.015 · Cited by 33
Pelclová, D., Ždímal, V., Kačer, P., Komarc, M., Fenclová, Z., Vlčková, Š., Zíková, N., Schwarz, J., Makeš, O., Navrátil, T., et al. (2016) · Reviews on Environmental Health · doi:10.1515/reveh-2016-0030 · Cited by 33
“All subjects breathed tidally for 15 min through a mouthpiece connected to the condenser (−20 °C) while wearing a nose-clip; the collection was performed in accordance with the guidelines of the American Thoracic Society and European Respiratory Society (7).”
BackgroundMethodInfluentialSpicuzza, L., Parisi, G. F., Tardino, L. G., Ciancio, N., Nenna, R., Midulla, F., & Leonardi, S. (2017) · Journal of Breath Research · doi:10.1088/1752-7163/aa9b39 · Cited by 33
Measuring Airway Inflammation in Asthmatic Children
Tenero, L., Zaffanello, M., Piazza, M., & PIACENTINI, G. L. (2018) · Frontiers in Pediatrics · doi:10.3389/fped.2018.00196 · Cited by 33
Mazur, W., Stark, H., Sovijärvi, A. R. A., Myllärniemi, M., & Kinnula, V. L. (2009) · Respiration · doi:10.1159/000206010 · Cited by 35
“Another noninvasive method for obtaining samples from the airways is a collection of exhaled breath condensate (EBC), which traps aerosolized particles (that is, cytokines and eicosanoids) and volatile compounds (that is, hydrogen peroxide) from the exhaled air. The analysis of EBC is difficult due to the dilution of…”
MethodOno, E., Mita, H., Taniguchi, M., Higashi, N., Tsuburai, T., Hasegawa, M., Miyazaki, E., Kumamoto, T., & Akiyama, K. (2008) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2008.06.009 · Cited by 35
“(male) 13 (9) 18 (8) Mean age (y; range) 35 (18-55) 31 (18-48) Duration of asthma (y) 15 (3-32) 18 (1-38) Total serum IgE (IU/mL) 755 (255-6852) 960 (252-15,480) Allergen IgE (UA/mL) 7.”
Inflamación pulmonar y sistémica en 2 fenotipos de EPOC
Alonso, J. L. I., Almonacid, C., Parra, T., & Pérez, J. (2006) · Archivos de Bronconeumología · doi:10.1016/s1579-2129(06)60542-9 · Cited by 33
Elevated inflammatory markers at preschool age precede persistent wheezing at school age
van de Kant, K. D. G., Jansen, M. A., Klaassen, E. M. M., van der Grinten, C. P. M., Rijkers, G. T., Muris, J. W. M., van Schayck, O. C. P., Jöbsis, Q., & Dompeling, E. (2011) · Pediatric Allergy and Immunology · doi:10.1111/j.1399-3038.2011.01244.x · Cited by 32
“Although an American/European Taskforce has presented recommendations about the methodology of EBC collection (22), there is still considerable room for improvement in collection methods and assays.”
BackgroundBrussino, L., Culla, B., Bucca, C. B., Giobbe, R., Boita, M., Isaia, G., Heffler, E. M., OLIARO, A., Filosso, P. L., & Rolla, G. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/2/027110 · Cited by 34
Youssef, O., Sarhadi, V. K., Armengol, G., Piirilä, P. L., Knuuttila, A., & Knuutila, S. (2016) · Genes Chromosomes and Cancer · doi:10.1002/gcc.22399 · Cited by 33
Airoldi, C., Ciaramelli, C., Fumagalli, M., Bussei, R., Mazzoni, V., Viglio, S., Iadarola, P., & Stolk, J. N. (2016) · Journal of Proteome Research · doi:10.1021/acs.jproteome.6b00648 · Cited by 34
Ding, L., Xu, S., Huang, Y., Yao, Y., Wang, Y., Chen, L., Zeng, Y., Li, L., Lin, Z., & Guo, L. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.1c05179 · Cited by 32
Manganese in exhaled breath condensate: A new marker of exposure to welding fumes
Hulo, S., Chérot‐Kornobis, N., Howsam, M., Crucq, S., de Broucker, V., Sobaszek, A., & Edmé, J. (2014) · Toxicology Letters · doi:10.1016/j.toxlet.2014.01.034 · Cited by 35
Exhaled leukotriene B4 in children with community acquired pneumonia
Carraro, S., Andreola, B., Alinovi, R., Corradi, M., Freo, L., Dalt, L. D., & Baraldi, E. (2008) · Pediatric Pulmonology · doi:10.1002/ppul.20889 · Cited by 32
“EBC was collected and processed according to recent ATS/ERS recommendations.(8) EBC was collected using the TURBO-DECCS (transportable unit for research on biomarkers obtained from disposable exhaled condensate collection systems) (ItalChill, Parma, Italy).”
Manney, S., Meddings, C., Harrison, R. M., Mansur, A., Karakatsani, A., Analitis, A., Katsouyanni, K., Perifanou, D., Kavouras, I. G., Kotronarou, N., et al. (2012) · Occupational and Environmental Medicine · doi:10.1136/oemed-2011-100255 · Cited by 32
Environmental temperature and relative humidity influence exhaled breath condensate pH: Table 1—
Kullmann, T., Barta, I., Antus, B., Valyon, M., & Horváth, I. (2008) · European Respiratory Journal · doi:10.1183/09031936.00128007 · Cited by 32
Self-citationMitchell, M. I., Ben‐Dov, I. Z., Ye, K. Q., Liu, C., Shi, M. K., Sadoughi, A., Shah, C. D., Siddiqui, T., Okorozo, A., Gutiérrez, M., et al. (2024) · Journal of Extracellular Vesicles · doi:10.1002/jev2.12440 · Cited by 31
“…hope to help develop more accurate lung cancer detection strategies (Anglim et al., 2008; Boots et al., 2015; Chen et al., 2021; Engel et al., 2004; Horváth et al., 2005; Matthiesen, 2020; Mutlu et al., 2021; Papineni & Rosenthal, 1997; Rahimpour et al., 2018; Safiri et al., 2022; Schmidt et al.,…”
BackgroundMethodHoffmeyer, F., Raulf, M., Harth, V., Bünger, J., & Brüning, T. (2009) · BMC Pulmonary Medicine · doi:10.1186/1471-2466-9-48 · Cited by 31
“Discussion EBC is an attractive non-invasive method for assessing airway diseases but its clinical use is still hampered by methodical limitations [5].”
BackgroundMethodInfluentialThe Role of Nicotinamide Adenine Dinucleotide Phosphate Oxidases in Lung Architecture Remodeling
Harijith, A. K., Natarajan, V., & Fu, P. (2017) · Antioxidants · doi:10.3390/antiox6040104 · Cited by 31
Outdoor fungal spores and acute respiratory effects in vulnerable individuals
Tham, R., Erbas, B., Dharmage, S. C., Tang, M. L. K., Aldakheel, F. M., Lodge, C., Thomas, P. S., Taylor, P. E., Abramson, M. J., & Lowe, A. J. (2019) · Environmental Research · doi:10.1016/j.envres.2019.108675 · Cited by 31
Biomarkers to predict asthma in wheezing preschool children
Bannier, M. A. G. E., van de Kant, K. D. G., Jöbsis, Q., & Dompeling, E. (2014) · Clinical & Experimental Allergy · doi:10.1111/cea.12460 · Cited by 31
DASH for asthma: A pilot study of the DASH diet in not-well-controlled adult asthma
Ma, J., Strub, P., Lavori, P. W., Buist, A. S., Camargo, C. A., Nadeau, K. C., Wilson, S. R., & Xiao, L. (2013) · Contemporary Clinical Trials · doi:10.1016/j.cct.2013.04.008 · Cited by 34
“Potential mediators—Markers of inflammation will be examined as mechanistic outcomes and potential mediators of the intervention effect on asthma control, including FeNO (using a NIOX MINO portable hand-held NO analyzer [91-95]), EBC pH (by CO2 standardization method) [96,97], serum total and differential leukocyte co…”
MethodHoffmeyer, F., Raulf, M., Weiß, T., Lehnert, M., Gawrych, K., Kendzia, B., Harth, V., Henry, J., Pesch, B., Brüning, T., et al. (2012) · Journal of Breath Research · doi:10.1088/1752-7155/6/2/027105 · Cited by 32
“Sampling of EBC is non-invasive and offers a suitable matrix for assessing markers of inflammation and oxidative stress (Horvath et al 2005, Hoffmeyer et al 2009a).”
BackgroundPappas, L. K., & Filippatos, G. S. (2011) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2011.05.010 · Cited by 31
Exhaled breath condensate sampling is not a new method for detection of respiratory viruses
Houspie, L., Coster, S. D., Keyaerts, E., Narongsack, P., Roy, R. D., Talboom, I., Sisk, M., Maes, P., Verbeeck, J., & Ranst, M. A. V. (2011) · Virology Journal · doi:10.1186/1743-422x-8-98 · Cited by 35
“EBCs mainly consist of water vapour but a small fraction contains respiratory droplets derived from the airway lining fluid [1,2].”
BackgroundAssessment of nanoparticles and metal exposure of airport workers using exhaled breath condensate
Marie, C., Dubosson, M., Touri, L., Zimmermann, E., Gaude-Môme, M., Leclerc, L., Durand, C., Klerlein, M., Molinari, N., Vachier, I., et al. (2016) · Journal of Breath Research · doi:10.1088/1752-7155/10/3/036006 · Cited by 33
“EBC collection and standardization EBC collection was performed using the RTubeTM device from Respiratory Research (USA) and following the American Thoracic Society/European Respiratory Society recommendations [26].”
MethodCruickshank-Quinn, C. I., Armstrong, M., Powell, R. L., Gomez, J., Elie, M. R., & Reisdorph, N. A. (2017) · Respiratory Research · doi:10.1186/s12931-017-0538-5 · Cited by 31
“EBC was collected per ATS/ERS recommendations [30].”
Proton Pump Inhibitor Improves Breath Marker in Moderate Asthma with Gastroesophageal Reflux Disease
Shimizu, Y., Dobashi, K., Zhao, J. J., Kawata, T., Ono, A., Yanagitani, N., Kaira, K., Utsugi, M., Hisada, T., Ishizuka, T., et al. (2007) · Respiration · doi:10.1159/000101437 · Cited by 31
“The analysis of exhaled breath condensate (EBC) is a novel approach to monitoring pulmonary disease and evaluating disease-related soluble markers in the airways [”
BackgroundBreath condensate nitrite correlates with hyperinflation in chronic obstructive pulmonary disease
Geßner, C., Hammerschmidt, S., Kühn, H., Hoheisel, G. B., Gillissen, A., Sack, U., & Wirtz, H. R. W. (2007) · Respiratory Medicine · doi:10.1016/j.rmed.2007.06.024 · Cited by 31
Reinhold, P., Jaeger, J., & Schroeder, C. (2006) · Biomarkers · doi:10.1080/13547500600572764 · Cited by 31
“According to the recommendations of a joint Task Force of the European Respiratory and the American Thoracic Societies, ‘exhaled breath condensate’ is the preferred term to describe the method of collecting condensate by cooling the exhaled breath (Horváth et al. 2005).”
MethodMalik, M., Demetrowitsch, T. J., Schwarz, K., & Kunze, T. (2024) · Communications Biology · doi:10.1038/s42003-024-05943-x · Cited by 30
“However, the devices are complex and require a cooling tool thatenablescondensationofbreath 11 .”
BackgroundMethodInfluentialZiętkowski, Z., Skiepko, R., Tomasiak, M. M., Mroczko, B., Szmitkowski, M., & Bodzenta‐Łukaszyk, A. (2009) · Respiration · doi:10.1159/000264923 · Cited by 30
“In the present study, we aimed to determine the role of RANTES expression in the airways in the pathogenesis of EIB in asthmatics.The study was performed on exhaled breath condensate (EBC). EBC samples were collected by cooling exhaled air – a noninvasive, easily performed and effort-independent, rapid procedure to ob…”
MethodEarly diagnosis and screening in lung cancer.
Cainap, C. I., Pop, L., Bălăcescu, O., & Cainap, S. S. (2020) · PubMed Central · Cited by 38
Fouka, E., Lamprianidou, E., Arvanitidis, K. I., Filidou, E., Kolios, G. C., Miltiades, P., Paraskakis, E., Antoniadis, A. P., Kotsianidis, Ι., & Bouros, D. E. (2014) · Lung · doi:10.1007/s00408-014-9619-0 · Cited by 30
Variability of exhaled breath condensate leukotriene B4and 8-isoprostane in COPD patients
Borrill, Z., Starkey, R. C., & Singh, D. (2007) · International Journal of COPD · doi:10.2147/copd.2007.2.1.71 · Cited by 30
Hasan, R. A., O’Brien, E., & Mancuso, P. (2011) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0b013e3182231644 · Cited by 32
Bajaj, P., & Ishmael, F. T. (2013) · Journal of Analytical Sciences Methods and Instrumentation · doi:10.4236/jasmi.2013.31004 · Cited by 33
“The concentration of biomolecules in EBC is highly diluted (up to 2000 to 10,000 fold) by condensed water vapor [6],”
Non‐invasive biomarker sampling and analysis of the exhaled breath proteome
Bloemen, K., Hooyberghs, J., Desager, K., Witters, E., & Schoeters, G. E. R. (2009) · PROTEOMICS - CLINICAL APPLICATIONS · doi:10.1002/prca.200800095 · Cited by 30
“Exhaled breath condensate was collected using an RTube (Respiratory Research), according to the ATS/ERS guidelines [12].”
MethodNon-invasive assessment of exhaled biomarkers in lung transplantation
Yates, D. H., Krishnan, A., Chow, S., & Thomas, P. S. (2011) · Journal of Breath Research · doi:10.1088/1752-7155/5/2/024001 · Cited by 32
“In September 2005, the ATS/ERS Task force published their recommendations on EBC, highlighting the various methodological issues and guidelines for standardizing this technique [20].”
MethodVagaggini, B., Bartoli, M. L., Cianchetti, S., Costa, F., Bacci, E., Dente, F. L., Franco, A. D., Malagrinò, L., & Paggiaro, P. (2010) · Respiratory Research · doi:10.1186/1465-9921-11-5 · Cited by 34
“Subjects breathed tidally for 15 min through a two-way non-rebreathing valve in order to prevent inspiratory and espiratory air mixing and saliva trapping [25].”
MethodGarcía‐de‐la‐Asunción, J., del Olmo, E. G., Perez-Griera, J., Martí, F., Galán, G., Aixelá, A. M., Wins, R., Guijarro, R., Arnau, A., Sarriá, B., et al. (2015) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezv207 · Cited by 30
“The samples were immediately deaerated with argon (350 ml/min for 10 min [13, 14]) and stored at −80°C until analysis.”
BackgroundMethodInfluentialBiomarkers of eosinophilic inflammation in asthma
Loutsios, C., Farahi, N., Porter, L., Lok, L. S. C., Peters, A. M., Condliffe, A. M., & Chilvers, E. R. (2014) · Expert Review of Respiratory Medicine · doi:10.1586/17476348.2014.880052 · Cited by 30
“Fireman E, Shtark M, Priel IE, et al. Hydrogen peroxide in exhaled breath condensate (EBC) vs eosinophil count in induced sputum (IS) in parenchymal vs airways lung diseases.”
BackgroundInfluentialSrinivasan, P., Dhingra, K., & Kailasam, K. (2023) · Journal of Materials Chemistry A · doi:10.1039/d3ta02660d · Cited by 30
Vijverberg, S. J. H., Koster, E. S., Koenderman, L., Arets, H. G. M., van der Ent, C. K., Postma, D. S., Koppelman, G. H., Raaijmakers, J. A. M., & der Zee, A. H. M. (2012) · Pediatric Allergy and Immunology · doi:10.1111/j.1399-3038.2012.01279.x · Cited by 30
“, standardization of EBC collection, the establishment of reference values for individual markers in EBC) need to be addressed before this technique can enter clinical practice (22).”
MethodChildhood asthma biomarkers: present knowledge and future steps
Moschino, L., Zanconato, S., Bozzetto, S., Baraldi, E., & Carraro, S. (2015) · Paediatric Respiratory Reviews · doi:10.1016/j.prrv.2015.05.001 · Cited by 34
Automated in Vivo Nanosensing of Breath-Borne Protein Biomarkers
Chen, H., Li, J., Zhang, X., Li, X., Yao, M., & Zheng, G. (2018) · Nano Letters · doi:10.1021/acs.nanolett.8b01070 · Cited by 29
Chen, C., Liu, S., Dong, W., Song, Y., Chu, M., Xu, J., Guo, X., Zhao, B., & Deng, F. (2020) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2020.141726 · Cited by 31
Tomasiak, M. M., Ziętkowski, Z., Przesław, K., Tomasiak, M., Skiepko, R., & Bodzenta‐Łukaszyk, A. (2012) · International Archives of Allergy and Immunology · doi:10.1159/000335674 · Cited by 29
Mastalerz, L., Sanak, M., Kumik, J., Gawlewicz‐Mroczka, A., Celejewska‐Wójcik, N., Ćmiel, A., & Szczeklik, A. (2012) · Journal of Allergy · doi:10.1155/2012/696792 · Cited by 29
Yeh, M. Y., Burnham, E. L., Moss, M. M., & Brown, L. A. S. (2007) · Respiratory Medicine · doi:10.1016/j.rmed.2007.09.005 · Cited by 31
“Reports from the EBC Task Force by the major American and European respiratory societies state that although dilution may be a factor influencing EBC data, it does not appear to improve reproducibility [24].”
BackgroundRoca, O., Gómez‐Ollés, S., Cruz, M. J., Muñoz, X., Griffiths, M., & Masclans, J. R. (2008) · Critical Care · doi:10.1186/cc6911 · Cited by 29
Mutti, A., & Corradi, M. (2006) · PubMed · Cited by 40
Maniscalco, M., Candia, C., Fuschillo, S., Ambrosino, P., Paris, D., & Motta, A. (2024) · Journal of Breath Research · doi:10.1088/1752-7163/ad7a9a · Cited by 28
“The temperature of the collecting room should be kept constant (24 ◦ C ± 1.0 ◦ C) throughout the sampling, and air contaminants possibly present in the collecting room should also be monitored [16].”
InfluentialBhimji, A., Bhaskaran, A., Singer, L. G., Kumar, D., Humar, A., Pavan, R., Lipton, J. H., Kuruvilla, J. G., Schuh, A. C., Yee, K. W. L., et al. (2017) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2017.09.018 · Cited by 30
Liu, H.-C., Lu, M., Lin, Y., Wu, T., Hsu, J., Jan, M., & Chen, C. (2012) · Journal of the Formosan Medical Association · doi:10.1016/j.jfma.2012.09.018 · Cited by 30
“The design of the condensing device and collection methods were based on recommendations by the American Thoracic Society/European Respiratory Society task force on EBC.(13) The details of the custom-made EBC collecting device are illustrated in Fig.”
BackgroundMethodInfluentialEotaxin-1 in exhaled breath condensate of stable and unstable asthma patients.
Ziętkowski, Z., Tomasiak, M. M., Skiepko, R., Ziętkowska, E., & Bodzenta‐Łukaszyk, A. (2010) · Respiratory Research · doi:10.1186/1465-9921-11-110 · Cited by 28
“EBC was collected by using a commercially available condenser (EcoScreen; Erich Jaeger GmbH, Hoechberg, Germany) according to the current ATS/ERS guidelines [7].”
BackgroundMethodInfluentialHillas, G., Loukides, S., Κostikas, Κ., & Bakakos, P. (2009) · Current Medicinal Chemistry · doi:10.2174/092986709788803178 · Cited by 33
Biomarkers in adult asthma: a systematic review of 8-isoprostane in exhaled breath condensate
Peel, A. M., Crossman-Barnes, C.-J., TANG, J. C. Y., Fowler, S. J., Davies, G. A., Wilson, A. M., & Loke, Y. K. (2017) · Journal of Breath Research · doi:10.1088/1752-7163/aa5a8a · Cited by 28
Two techniques to sample non-volatiles in breath—exemplified by methadone
Ljungkvist, G., Ullah, S., Tinglev, Å., Stein, K., Bake, B., Larsson, P., Almstrand, A., Viklund, E., Hammar, O., Sandqvist, S., et al. (2017) · Journal of Breath Research · doi:10.1088/1752-7163/aa8b25 · Cited by 29
“Exhaled breath condensate (EBC), obtained by cooling exhaled breath, was the first method used [9, 10].”
MethodKonieczna, L., Pyszka, M., Okońska, M., Niedźwiecki, M., & Bączek, T. (2018) · Journal of Chromatography A · doi:10.1016/j.chroma.2018.02.019 · Cited by 28
Analysis of exhaled air for early-stage diagnosis of lung cancer: opportunities and challenges
Ganeev, A. A., Gubal, A. R., Lukyanov, G., Арсеньев, А. И., Барчук, А. А., Jahatspanian, I. E., Gorbunov, I. S., Rassadina, A., Nemets, V. M., Nefedov, A., et al. (2018) · Russian Chemical Reviews · doi:10.1070/rcr4831 · Cited by 28
Korovesi, I., Papadomichelakis, E., Orfanos, S. E., Giamarellos‐Bourboulis, E. J., Livaditi, O., Πελεκάνου, Α., Sotiropoulou, C., Koutsoukou, A., Dimopoulou, I., Ekonomidou, F., et al. (2011) · Anesthesiology · doi:10.1097/aln.0b013e31820d84db · Cited by 29
Chromium in exhaled breath condensate and pulmonary tissue of non-small cell lung cancer patients
Goldoni, M., Caglieri, A., Corradi, M., Poli, D., Rusca, M., Carbognani, P., & Mutti, A. (2007) · International Archives of Occupational and Environmental Health · doi:10.1007/s00420-007-0242-8 · Cited by 33
Corradi, M., Pignatti, P., Brunetti, G., Goldoni, M., Caglieri, A., Nava, S., Moscato, G., & Balbi, B. (2008) · PubMed · Cited by 28
Differential Cytokine Pattern in the Exhaled Breath of Patients with Lung Cancer
Kullmann, T., Barta, I., Csiszér, E., Antus, B., & Horváth, I. (2008) · Pathology & Oncology Research · doi:10.1007/s12253-008-9046-8 · Cited by 28
Self-citationExploring the Potential Role of Metabolomics in COPD: A Concise Review
Tirelli, C., Mira, S., Belmonte, L. A., Filippi, F. D., Grassi, M. D., Italia, M., Maggioni, S., Guido, G., Mondoni, M., Canonica, G. W., et al. (2024) · Cells · doi:10.3390/cells13060475 · Cited by 27
“Compared to NMRS, MS offers higher intrinsic sensitivity and specificity, although it typically requires a preceding separation step, such as gas chromatography (GC), high-performance liquid chromatography (HPLC), ultra-per-formance liquid chromatography (UPLC), or capillary electrophoresis (CE) [15].”
BackgroundBelo, J., Martins, P., Papoila, A. L., Palmeiro, T., Caires, I., Alves, M., Nogueira, S., Aguiar, F., Mendes, A., Cano, M., et al. (2019) · Journal of Environmental Science and Health Part A · doi:10.1080/10934529.2019.1637206 · Cited by 27
Airway inflammatory and spirometric measurements in obese children.
Chow, J. S. W., Leung, A. S. M., Li, W. W. S., Tse, T. P. K., Sy, H. Y., & Leung, T. (2009) · PubMed · Cited by 27
Newport, S., Amin, N., & Dozor, A. J. (2009) · Pediatric Pulmonology · doi:10.1002/ppul.21078 · Cited by 27
Cathcart, M. P. M., Love, S., & Hughes, K. (2011) · The Veterinary Journal · doi:10.1016/j.tvjl.2011.08.016 · Cited by 30
Carpagnano, G. E., Spanevello, A., Palladino, G. P., Gramiccioni, C., Ruggieri, C., Carpagnano, F., & Barbaro, M. P. F. (2009) · Lung Cancer · doi:10.1016/j.lungcan.2009.03.033 · Cited by 27
Biomarkers for Invasive Aspergillosis: The Challenges Continue
Johnson, G. L., Ferrini, A., Dolan, S. K., Nolan, T., Agrawal, S. G., Doyle, S., & Bustin, S. A. (2014) · Biomarkers in Medicine · doi:10.2217/bmm.13.129 · Cited by 31
Antioxidants and Mucolytics in COPD Management: When (if ever) and in Whom?
Hillas, G., Nikolakopoulou, S., Hussain, S. N. A., & Vassilakopoulos, T. (2013) · Current Drug Targets · doi:10.2174/1389450111314020007 · Cited by 28
Jafari, M., Solhi, E., Tagi, S., Hasanzadeh, M., Jouyban‐Gharamaleki, V., Jouyban, A., & Shadjou, N. (2018) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2018.10.048 · Cited by 27
Mechanical ventilation induces changes in exhaled breath condensate of patients without lung injury
Roca, O., Gómez‐Ollés, S., Cruz, M. J., Muñoz, X., Griffiths, M., & Masclans, J. R. (2010) · Respiratory Medicine · doi:10.1016/j.rmed.2010.01.013 · Cited by 27
Safety and feasibility of exhaled breath condensate collection in ventilated infants and children
Müller, W. G., Morini, F., Eaton, S. D., Peters, M. J., & Jaffé, A. (2006) · European Respiratory Journal · doi:10.1183/09031936.06.00063505 · Cited by 27
“A standardised approach to EBC collection in children does not exist, but is clearly needed for the interpretation and comparison of results [ 20 ].”
ResultKita-Milczarska, K., Gawinowska, M., Chełmińska, M., & Niedoszytko, M. (2024) · International Journal of Molecular Sciences · doi:10.3390/ijms25137395 · Cited by 28
“Results based on immunological analyses should be verified using precise analytical methods, such as LC-MS and high-performance liquid chromatography, to ensure the quantitative analysis of compounds in EBC [19,104,105].”
BackgroundMethodInfluentialGangi, I. M. D., Pirillo, P., Carraro, S., Gucciardi, A., Naturale, M., Baraldi, E., & Giordano, G. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.09.032 · Cited by 26
Hu, Z., Zhao, Y., Cheng, Y., Guo, C., Wang, X., Li, N., Liu, J., Kang, H. D., Xia, G., Hu, P., et al. (2016) · Chinese Medical Journal · doi:10.4103/0366-6999.189923 · Cited by 26
“Exhaled breath condensate collection and measurement EBC was collected according to the European Respiratory Society/American Thoracic Society recommendations,[10] using a Chinese‐made EBC collector (Converge‐Sci Co.”
MethodWardzyńska, A., Makowska, J. S., Pawelczyk, M., Piechota-Polańczyk, A., Kurowski, M. M., & Kowalski, M. L. (2017) · Allergy Asthma and Immunology Research · doi:10.4168/aair.2017.9.2.126 · Cited by 26
“EBC samples were collected using TURBODECCS 09 unit (Medivac, Parma, Italy) according to the manufacturer’s instructions and ERS/ATS recommendations.(19) Patients were asked to breath tidally for 10 minutes through the mouthpiece with a saliva trap in the sitting position.”
MethodAdigal, S. S., Rayaroth, N. V., John, R. V., Pai, K. M., Bhandari, S., Mohapatra, A. K., Lukose, J., Patil, A., Bankapur, A., & Chidangil, S. (2021) · Expert Review of Molecular Diagnostics · doi:10.1080/14737159.2021.1874355 · Cited by 26
“urged the scientists to use it as potential specimen for respiratory disorders [47].”
BackgroundDavis, C. S., Gagermeier, J. P., Dilling, D. F., Alex, C. G., Lowery, E. M., Kovacs, E. J., Love, R. B., & Fisichella, P. M. (2010) · Clinical Transplantation · doi:10.1111/j.1399-0012.2010.01243.x · Cited by 28
“to help gain understanding of the time courses of important pathologic processes’’ (68).”
BackgroundMethodRoberge, R. J. (2012) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2012.715066 · Cited by 30
“At sedentary levels(19) or low work rates, most individuals are nasal breathers, with the switch from nasal to oronasal breathing occurring at activity levels associated with breathing volumes ∼35 L/min.”
BackgroundNyberg, A. G., Stricklin, D. L., & Sellström, Å. (2011) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph8124521 · Cited by 26
“It is likely that even more sensitive assays will be able as more potent antibodies are developed and new molecular techniques are introduced [36].”
BackgroundDiagnostic approach in cases with suspected work-related asthma
Aasen, T., Burge, P. S., Henneberger, P. K., Schlünssen, V., Baur, X., on behalf of the ERS Task Force on the Management of Work-related Asthma, & EOM Society (2013) · Journal of Occupational Medicine and Toxicology · doi:10.1186/1745-6673-8-17 · Cited by 30
“EBC is collected by cooling or freezing exhaled air and is also totally non-invasive [113,114].”
BackgroundAhmed, N., Bezabeh, T., Ijare, O. B., Myers, R. L., Alomran, R., Aliani, M., Nugent, Z. J., Banerji, S. O., Kim, J. S., Qing, G., et al. (2016) · Magnetic Resonance Insights · doi:10.4137/mri.s40864 · Cited by 28
Metadata
- Authors
- Horváth, I., Hunt, J., & Barnes, P. J.
- Affiliations
- Országos Korányi Tbc és Pulmonológiai Intézet (HU)
- University of Virginia (US)
- Institute of Cancer Research (GB)
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2005-09
- Volume
- 26
- Issue
- 3
- Pages
- 523-548
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W1989935661
- Cited by
- 1,284
- References
- 280
- Citations by year
- 2026: 43 · 2025: 28 · 2024: 35 · 2023: 30 · 2022: 51 · 2021: 43 · 2020: 47 · 2019: 50 · 2018: 53 · 2017: 61 · 2016: 60 · 2015: 68 · 2014: 76 · 2013: 82 · 2012: 107
- FWCI
- 48.86
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- European Respiratory Journal (publishedVersion)
- PubMed (publishedVersion)
- Research Publications (Maastricht University) (publishedVersion, other-oa)
- Publikationsdatenbank der Fraunhofer-Gesellschaft (Fraunhofer-Gesellschaft) (submittedVersion)
- Fraunhofer-Publica (Fraunhofer-Gesellschaft) (submittedVersion)
- Radboud Repository (Radboud University) (submittedVersion)
- OpenAgrar (submittedVersion)
- Padua Research Archive (University of Padova) (submittedVersion)
- Research Publications (Maastricht University) (submittedVersion, other-oa)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Chemical Sensor Technologies
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Asthma and respiratory diseases
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Chronic Obstructive Pulmonary Disease (COPD) Research
- Keywords
- exhaled breath condensate, adenosine, hydrogen peroxide, isoprostanes, leukotrienes, nitrogen oxides, cytokines, reproducibility, longitudinal study, lung disease
- MeSH terms
- Breath Tests, Humans, Lung Diseases, Reproducibility of Results, Biomarkers, Oxidative Stress
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.