Exhaled breath condensate: methodological recommendations and unresolved questions
Open accessThe DOI matches its Crossref record; 281 of the 281 references it cites were found in a registry or an index.
Abstract
Collection of exhaled breath condensate (EBC) is a noninvasive method for obtaining samples from the lungs. EBC contains large number of mediators including adenosine, ammonia, hydrogen peroxide, isoprostanes, leukotrienes, nitrogen oxides, peptides and cytokines. Concentrations of these mediators are influenced by lung diseases and modulated by therapeutic interventions. Similarly EBC pH also changes in respiratory diseases. The aim of the American Thoracic Society/European Respiratory Society Task Force on EBC was to identify the important methodological issues surrounding EBC collection and assay, to provide recommendations for the measurements and to highlight areas where further research is required. Based on the currently available evidence and the consensus of the expert panel for EBC collection, the following general recommendations were put together for oral sample collection: collect during tidal breathing using a noseclip and a saliva trap; define cooling temperature and collection time (10 min is generally sufficient to obtain 1–2 mL of sample and well tolerated by patients); use inert material for condenser; do not use resistor and do not use filter between the subject and the condenser. These are only general recommendations and certain circumstances may dictate variation from them. Important areas for future research involve: ascertaining mechanisms and site of exhaled breath condensate particle formation; determination of dilution markers; improving reproducibility; employment of EBC in longitudinal studies; and determining the utility of exhaled breath condensate measures for the management of individual patients. These studies are required before recommending this technique for use in clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“EBC was obtained approximately 70 min before swimming began and 35 min after swimming ended using an EcoScreen condenser (Jaeger GmbH, Würzburg, Germany) following American Thoracic Society/European Respiratory Society Task Force recommendations (Horvath et al. 2005).”
From Short-Term Changes in Respiratory Biomarkers after Swimming in a Chlorinated Pool (2010) · cites this paper as Horvath et al. 2005
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Brainard, D. H. (1997) · Spatial Vision · doi:10.1163/156856897x00357 · Cited by 19,702
The VideoToolbox software for visual psychophysics: transforming numbers into movies
Pelli, D. G. (1997) · Spatial Vision · doi:10.1163/156856897x00366 · Cited by 11,098
Mixed-Effects Models in S and S-PLUS
(2001) · Technometrics · doi:10.1198/tech.2001.s574 · Cited by 9,278
Best Linear Unbiased Estimation and Prediction under a Selection Model
Henderson, C. R. (1975) · Biometrics · doi:10.2307/2529430 · Cited by 2,497
Metabonomics: a platform for studying drug toxicity and gene function
Nicholson, J. K., Connelly, J., Lindon, J. C., & Holmes, E. (2002) · Nature Reviews Drug Discovery · doi:10.1038/nrd728 · Cited by 1,914
Nonlinear Mixed Effects Models for Repeated Measures Data
Lindstrom, M. J., & Bates, D. M. (1990) · Biometrics · doi:10.2307/2532087 · Cited by 1,795
That BLUP is a Good Thing: The Estimation of Random Effects
Robinson, G. K. (1991) · Statistical Science · doi:10.1214/ss/1177011926 · Cited by 1,686
Effects of antioxidant enzymes in the molecular control of reactive oxygen species toxicology
Matés, >. M. (2000) · Toxicology · doi:10.1016/s0300-483x(00)00306-1 · Cited by 1,518
Peroxynitrite-mediated tyrosine nitration catalyzed by superoxide dismutase
Ischiropoulos, H., Zhu, L., Chen, J., Tsai, M., Martin, J. C., Smith, C. D., & Beckman, J. S. (1992) · Archives of Biochemistry and Biophysics · doi:10.1016/0003-9861(92)90431-u · Cited by 1,495
Research works printed but not linked: 40
- 2002, Am J Respir Crit Care Med, 65, 663
- 1999, Eur Respir Rev, 68, 246
- 1985, Am Rev Respir Dis, 131, 894
- 2002, Eur J Med Res, 7, 353
- 2003, Eur J Med Res, 8, 505
- 1998, Monaldi Arch Chest Dis, 53, 268
- 1999, Eur Respir J, 14, 245
- 10.1002/1615-9861(200206)2:6<690::aid-prot690>3.0.co;2-6 · doi:10.1002/1615-9861(200206)2:6<690::aid-prot690>3.0.co;2-6
- 2000, Monaldi Arch Chest Dis, 55, 185
- 2003, Clin Lab, 49, 637
- 1997, Eur Respir J, 10, 1231
- 1986, Lancet, I, 11
- 1993, Anesth Analg, 77, 963
- 2003, Physiol Res, 52, 327
- 1995, Lancet, 346, 1235
- 10.1053/rmed.2001.1117 · DOI
- 1993, J Pharmacol Exp Ther, 267, 1529
- 1993, Am Rev Respir Dis, 15, 161
- 2002, Int Marit Health, 53, 93
- 1995, Appl Cardiopulmon Pathophysiol, 5, 215
- 10.1164/rccm.200206-507oc · DOI · Paper page
- 2003, Am J Respir Crit Care Med, 167, 91
- 2002, Int J Biol Markers, 17, 141
- 2001, J Heart Lung Transplant, 20, 184
- 1998, Pneumologie, 52, 426
- 2002, Eur J Med Res, 7, 290
- 2002, Curr Opin Pulm Med, 1, 25
- 2002, Int J Occup Med Environ Health, 15, 317
- 2003, Am J Respir Crit Care Med, 168, 1129
- 2004, Undersea Hyperb Med, 31, 217
- 2004, Physiol Res, 53, 561
- 2004, J Chromatogr B Analyt Technol Biomed Life Sci, 809, 199, 10.1016/s1570-0232(04)00513-6 · doi:10.1016/s1570-0232(04)00513-6
- 10.1007/s00408-004-2506-3 · DOI
- 10.1136/vr.155.23.744 · doi:10.1136/vr.155.23.744
- 2004, Thorax, 59, 1005
- 10.1002/rcm.1682 · DOI
- 2004, Physiol Res, 53, 561
- 10.1016/j.jfms.2003.12.002 · DOI
- 2004, Environ Health Perspect, 112, 1293, 10.1289/ehp.7108 · DOI
- 10.1016/s0956-5663(02)00083-0 · DOI · Paper page
Cited by
Items 201–300 of 1,000
Profile of eicosanoids in breath condensate in asthma and COPD
Fritscher, L. G., Post, M., Rodrigues, M. T., Silverman, F., Balter, M., Chapman, K. R., & Zamel, N. (2012) · Journal of Breath Research · doi:10.1088/1752-7155/6/2/026001 · Cited by 62
“to high variability [1].”
BackgroundInfluentialInflammatory markers in exhaled breath condensate from patients with asthma
Ueno, T., Kataoka, M., Hirano, A., Iio, K., Tanimoto, Y., Kanehiro, A., Okada, C., Soda, R., Takahashi, K., & Tanimoto, M. (2008) · Respirology · doi:10.1111/j.1440-1843.2008.01315.x · Cited by 66
Markers of lipid oxidative damage in the exhaled breath condensate of nano TiO2production workers
Pelclová, D., Ždímal, V., Kačer, P., Zíková, N., Komarc, M., Fenclová, Z., Vlčková, Š., Schwarz, J., Makeš, O., Syslová, K., et al. (2016) · Nanotoxicology · doi:10.1080/17435390.2016.1262921 · Cited by 62
“Their formation in the respiratory tract has been attributed either to turbulent airflow or by a process of bubble bursting during opening of the bronchioles following exhalation (Horvath et al., 2005).”
BackgroundMethodInfluentialBregy, L., Nussbaumer‐Ochsner, Y., Sinues, P., García‐Gómez, D., Suter, Y., Gaisl, T., Stebler, N., Gaugg, M. T., Kohler, M., & Zenobi, R. (2018) · Clinical mass spectrometry · doi:10.1016/j.clinms.2018.02.003 · Cited by 65
Verma, G., & Gupta, A. (2025) · Small · doi:10.1002/smll.202411495 · Cited by 64
Conventz, A., Musiol, A., Brodowsky, C., Müller-Lux, A., Dewes, P., Kraus, T., & Schettgen, T. (2007) · Journal of Chromatography B · doi:10.1016/j.jchromb.2007.10.031 · Cited by 61
Eoxins: A new inflammatory pathway in childhood asthma
Sachs‐Olsen, C., Sanak, M., Lang, A. M., Gielicz, A., Mowinckel, P., Carlsen, K. L., Carlsen, K., & Szczeklik, A. (2010) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2010.07.015 · Cited by 61
“003 SPT, any positive, n (%) 5 (21) 73 (68)k 2 (11) <.”
Pulmonary biomarkers in COPD exacerbations: a systematic review
Koutsokera, A., Κostikas, Κ., Nicod, L. P., & Fitting, J.-W. (2013) · Respiratory Research · doi:10.1186/1465-9921-14-111 · Cited by 65
“Although readily implemented in the research laboratory, their wide application has long been hampered by the lack of standardization and the absence of reference values, issues that are being increasingly addressed in the literature [4,5].”
BackgroundEffects of CPAP therapy withdrawal on exhaled breath pattern in obstructive sleep apnoea
Schwarz, E. I., Martinez-Lozano Sinues, P., Bregy, L., Gaisl, T., Garcia Gomez, D., Gaugg, M. T., Suter, Y., Stebler, N., Nussbaumer-Ochsner, Y., Bloch, K. E., et al. (2016) · Thorax · doi:10.1136/thoraxjnl-2015-207597 · Cited by 60
“following the recommendations suggested by the ATS/ERS task force.[21] These samples were”
MethodMotta, A., Paris, D., D’Amato, M., Melck, D. J., Calabrese, C., Vitale, C., Stanziola, A. A., Corso, G., Sofia, M., & Maniscalco, M. (2014) · Journal of Proteome Research · doi:10.1021/pr5010407 · Cited by 63
Ferguson, M., Semmens, E. O., Dumke, C. L., Quindry, J. C., & Ward, T. J. (2016) · Journal of Occupational and Environmental Medicine · doi:10.1097/jom.0000000000000688 · Cited by 64
Sofia, M., Maniscalco, M., de Laurentiis, G., Paris, D., Melck, D. J., & Motta, A. (2011) · BioMed Research International · doi:10.1155/2011/403260 · Cited by 60
Metabolomics: A New Frontier for Research in Pediatrics
Carraro, S., Giordano, G., Reniero, F., Perilongo, G., & Baraldi, E. (2009) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2009.01.014 · Cited by 67
Xu, Z., Shen, F., Li, X., Wu, Y. H., Chen, Q., Xu, J., & Yao, M. (2012) · PLoS ONE · doi:10.1371/journal.pone.0041137 · Cited by 60
“In addition, EBC collection is strictly limited to the method condensation only in most studies [38].”
MethodProfiling the Proteome of Exhaled Breath Condensate in Healthy Smokers and COPD Patients by LC-MS/MS
Fumagalli, M., Ferrari, F., Luisetti, M., Stolk, J. N., Hiemstra, P. S., Capuano, D., Viglio, S., Fregonese, L., Cerveri, I., Corana, F., et al. (2012) · International Journal of Molecular Sciences · doi:10.3390/ijms131113894 · Cited by 60
“, Austin, TX, USA) according to ATS/ERS guidelines [21].”
Mandon, J., Högman, M., Merkus, P. J. F. M., van Amsterdam, J., Harren, F. J. M., & Cristescu, S. M. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.1.017003 · Cited by 65
Oxidative Stress Levels in Exhaled Breath Condensate Associated With COPD and Smoking
İnönü, H., Doruk, S., Şahin, Ş., Erkorkmaz, Ü., Çelik, D., Çelikel, S., & Seyfıklı, Z. (2012) · Respiratory Care · doi:10.4187/respcare.01302 · Cited by 60
Exhaled Breath Condensate pH and Childhood Asthma
Nicolaou, N. C., Lowe, L. A., Murray, C. S., Woodcock, A. A., Simpson, A., & Čustović, A. (2006) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200601-140oc · Cited by 59
Prediction of asthma exacerbations in children: results of a one‐year prospective study
Robroeks, C. M. H. H. T., van Vliet, D., Jöbsis, Q., Braekers, R., Rijkers, G. T., Wodzig, W. K. W. H., Bast, A., Zimmermann, L. J. I., & Dompeling, E. (2012) · Clinical & Experimental Allergy · doi:10.1111/j.1365-2222.2012.03992.x · Cited by 63
Koczulla, A. R., Noeske, S., Herr, C., Jörres, R. A., Römmelt, H., Vogelmeier, C. F., & Bals, R. (2009) · Respiration · doi:10.1159/000245325 · Cited by 59
“also found a correlation between pH and NH 4 + ; however, this group did not use nose clips as recommended [”
MethodKilk, K., Aug, A., Ottas, A., Soomets, U., Altraja, S., & Altraja, A. (2018) · International Journal of Molecular Sciences · doi:10.3390/ijms19030666 · Cited by 59
“, Austin, TX, USA) with the condenser precooled down to −80 ◦C by a cooling sleeve according to manufacturer’s instructions and published recommendations [29,55].”
MethodExhaled breath condensate collection in the mechanically ventilated patient
Carter, S. R., Davis, C. S., & Kovacs, E. J. (2012) · Respiratory Medicine · doi:10.1016/j.rmed.2012.02.003 · Cited by 61
“Over 10,000 individual collections have been performed using different devices in laboratories all over the world and no adverse events have been reported (8).”
BackgroundInfluentialMakris, D. A., Paraskakis, E., Korakas, P., Karagiannakis, E., Sourvinos, G., Siafakas, N. M., & Tzanakis, N. (2007) · Respiration · doi:10.1159/000106377 · Cited by 59
Thomas, P. S., Lowe, A. J., Samarasinghe, P., Lodge, C., Huang, Y. C., Abramson, M. J., Dharmage, S. C., & Jaffé, A. (2013) · Pediatric Pulmonology · doi:10.1002/ppul.22776 · Cited by 63
“In addition to FENO, breath analysis research has continued to progress with further studies of the volatile fraction of the exhaled breath using ‘‘electronic noses,’’ which are directed towards a diagnostic approach, while soluble volatile and non-volatile components can be collected and measured as exhaled breath co…”
Asymmetric Dimethylarginine in Exhaled Breath Condensate and Serum of Children With Asthma
Carraro, S., Giordano, G., PIACENTINI, G. L., Kantar, A., Moser, S., Cesca, L., Berardi, M., Gangi, I. M. D., & Baraldi, E. (2013) · CHEST Journal · doi:10.1378/chest.12-2379 · Cited by 58
Exhaled Nitric Oxide and Exhaled Breath Condensate pH in Severe Refractory Asthma
Tseliou, E., Bessa, V., Hillas, G., Delimpoura, V., Papadaki, G. F., Roussos, C., Papiris, S. A., Bakakos, P., & Loukides, S. (2010) · CHEST Journal · doi:10.1378/chest.09-1257 · Cited by 58
Shenai, S., Amisano, D., Ronacher, K., Kriel, M., Banada, P. P., Song, T., Lee, M., Joh, J.-S., Winter, J. A., Thayer, R., et al. (2013) · Journal of Clinical Microbiology · doi:10.1128/jcm.01743-13 · Cited by 65
Pelclová, D., Barošová, H., Kukutschová, J., Ždímal, V., Navrátil, T., Fenclová, Z., Vlčková, Š., Schwarz, J., Zíková, N., Kačer, P., et al. (2015) · Journal of Breath Research · doi:10.1088/1752-7155/9/3/036008 · Cited by 65
“Exhaled breath condensate (EBC) is the liquid obtained after cooling the exhaled air of a subject, supposedly reflecting the composition of the bronchoalveolar lining fluid [11, 12].”
BackgroundLex, C., Zacharasiewicz, A. S., Payne, D., Wilson, N., Nicholson, A. G., Kharitonov, S. A., Barnes, P. J., & Bush, A. (2006) · Respiratory Research · doi:10.1186/1465-9921-7-63 · Cited by 58
“However, it has been noted that comparisons of data obtained in different laboratories are currently difficult because of the lack of standardised procedure for validated analytic techniques [11].”
BackgroundMethodSelf-citationGarcía‐Gómez, D., Sinues, P., Barrios‐Collado, C., Vidal‐de‐Miguel, G., Gaugg, M. T., & Zenobi, R. (2015) · Analytical Chemistry · doi:10.1021/ac504796p · Cited by 61
Detection of Pseudomonas aeruginosa in sputum headspace through volatile organic compound analysis
Goeminne, P. C., Vandendriessche, T., Van Eldere, J., Nicolai, B. M., Hertog, M. L., & Dupont, L. J. (2012) · Respiratory Research · doi:10.1186/1465-9921-13-87 · Cited by 55
“aeruginosa infection and the monitoring of response to treatment (eg eradication therapy) [35].”
BackgroundPredictive Biomarkers for Asthma Therapy
Medrek, S. K., Parulekar, A. D., & Hanania, N. A. (2017) · Current Allergy and Asthma Reports · doi:10.1007/s11882-017-0739-5 · Cited by 60
Exhaled Breath Condensate: A Promising Source for Biomarkers of Lung Disease
Liang, Y., Yeligar, S. M., & Brown, L. A. S. (2012) · The Scientific World JOURNAL · doi:10.1100/2012/217518 · Cited by 57
“The Scientific World Journal Volume 2012, Article ID 217518, 7 pages doi:10.1100/2012/217518 The cientificWorldJOURNAL”
BackgroundInfluentialRT-PCR diagnosis of COVID-19 from exhaled breath condensate: a clinical study
Sawano, M., Takeshita, K., Ohno, H., & Oka, H. (2021) · Journal of Breath Research · doi:10.1088/1752-7163/ac0414 · Cited by 58
Rapid Molecular Assays for the Diagnosis of Drug-Resistant Tuberculosis
Nandlal, L., Perumal, R., & Naidoo, K. (2022) · Infection and Drug Resistance · doi:10.2147/idr.s381643 · Cited by 58
“sampling the respiratory tract, which can be performed with minimal patient effort using portable equipment, and which can be repeated several times within short intervals.(16) Breath analysis has predominantly focused on the detection of volatile organic compound with TB-specific signatures.”
MethodBreath metabolomic profiling by nuclear magnetic resonance spectroscopy in asthma
Ibrahim, B., Marsden, P., Smith, J. A., Čustović, A., Nilsson, M., & Fowler, S. J. (2013) · Allergy · doi:10.1111/all.12211 · Cited by 61
“The samples in the Carraro study were dried before adding D2O while we used the intact sample; drying might cause the loss of some of the metabolites, especially volatile and unstable compounds (20).”
BackgroundMethodWalsh, B. K., Mackey, D. J., Pajewski, T. N., Yu, Y., Gaston, B. M., & Hunt, J. F. (2006) · Respiratory Care · doi:10.4187/respcare.06511125 · Cited by 56
Self-citationCritical Relevance of Stochastic Effects on Low-Bacterial-Biomass 16S rRNA Gene Analysis
Erb‐Downward, J. R., Falkowski, N. R., D’Souza, J. C., McCloskey, L., McDonald, R. A., Brown, C. A., Shedden, K., Dickson, R. P., Freeman, C. M., Stringer, K. A., et al. (2020) · mBio · doi:10.1128/mbio.00258-20 · Cited by 57
Exhaled Breath Condensate—A Non-Invasive Approach for Diagnostic Methods in Asthma
Połomska, J., Bar, K., & Sozańska, B. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10122697 · Cited by 60
“It was indicated that subjects usually tolerate this period of collection without fatigue [9].”
BackgroundMethodInfluentialBrindicci, C., Ito, K., Torre, O., Barnes, P. J., & Kharitonov, S. A. (2008) · CHEST Journal · doi:10.1378/chest.08-0964 · Cited by 59
Self-citationSurfactant protein A and albumin in particles in exhaled air
Larsson, P., Mirgorodskaya, E. E., Samuelsson, L., Bake, B., Almstrand, A., Bredberg, A., & Olin, A. (2011) · Respiratory Medicine · doi:10.1016/j.rmed.2011.10.008 · Cited by 60
Characterization of Exhaled Particles from the Human Lungs in Airway Obstruction
Schwarz, K., Biller, H., Windt, H., Koch, W., & Hohlfeld, J. M. (2014) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2013.1104 · Cited by 55
“(4) In this study, we investigated the effects of airway obstruction.”
Proteomics of exhaled breath: methodological nuances and pitfalls
Kurova, V. S., Anaev, E. K., Kononikhin, A. S., Fedorchenko, K. Y., Popov, I. A., Kalupov, T. L., Братанов, Д. О., Николаев, Е. Н., & Varfolomeev, S. D. (2009) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2009.166 · Cited by 55
Gube, M., Ebel, J., Brand, P., Göen, T., Holzinger, K., Reisgen, U., & Kraus, T. (2010) · International Archives of Occupational and Environmental Health · doi:10.1007/s00420-010-0516-4 · Cited by 58
Schillebeeckx, E., van Meerbeeck, J. P., & Lamote, K. (2021) · European Respiratory Review · doi:10.1183/16000617.0057-2021 · Cited by 62
Noninvasive glucose detection in exhaled breath condensate
Tankasala, D., & Linnes, J. C. (2019) · Translational research · doi:10.1016/j.trsl.2019.05.006 · Cited by 55
Evaluation of exhaled breath condensate pH as a biomarker for COPD
MacNee, W., Rennard, S. I., Hunt, J. F., Edwards, L. D., Miller, B. E., Locantore, N., & Tal‐Singer, R. (2011) · Respiratory Medicine · doi:10.1016/j.rmed.2011.02.009 · Cited by 54
Self-citationDeterminants of variability of protein content, volume and pH of exhaled breath condensate
Bloemen, K., Lissens, G., Desager, K., & Schoeters, G. E. R. (2006) · Respiratory Medicine · doi:10.1016/j.rmed.2006.10.008 · Cited by 54
Yoda, Y., Otani, N., Sakurai, S., & Shima, M. (2014) · Journal of Epidemiology · doi:10.2188/jea.je20130155 · Cited by 57
Oxidative stress and inflammatory markers in the exhaled breath condensate of children with OSA
Malakasioti, G., Alexopoulos, E. Ι., Befani, C. D., Tanou, K., Varlami, V., Ziogas, D. C., Liakos, P., Gourgoulianis, K. I., & Kaditis, A. G. (2011) · Sleep And Breathing · doi:10.1007/s11325-011-0560-7 · Cited by 53
“The method is based on the assumption that concentrations of substances in EBC reflect the composition of the fluid layer which covers the bronchoalveolar epithelium [17].”
MethodFunctional and biological characteristics of asthma in cleaning workers
Vizcaya, D., Mirabelli, M. C., Orriols, R., Antó, J. M., Barreiro, E., Burgos, F., Arjona, L., Gómez, F. P., & Zock, J. (2013) · Respiratory Medicine · doi:10.1016/j.rmed.2013.01.011 · Cited by 54
Leukotriene B 4 Contributes to Exhaled Breath Condensate and Sputum Neutrophil Chemotaxis in COPD
Corhay, J.-L., Henket, M. A., Nguyen, D., Duysinx, B., Sele, J., & Louis, R. E. (2009) · CHEST Journal · doi:10.1378/chest.08-2782 · Cited by 53
Mitochondrial DNA mutations in exhaled breath condensate of patients with lung cancer
Yang Ai, S. S., Hsu, K., Herbert, C., Cheng, Z., Hunt, J., Lewis, C. R., & Thomas, P. S. (2013) · Respiratory Medicine · doi:10.1016/j.rmed.2013.02.007 · Cited by 52
Self-citationNon‐invasive biomarkers in exacerbations of obstructive lung disease
Warwick, G., Thomas, P. S., & Yates, D. H. (2013) · Respirology · doi:10.1111/resp.12089 · Cited by 52
Feasibility of a new method to collect exhaled breath condensate in pre‐school children
Rosias, P. P. R., Robroeks, C. M. H. H. T., van de Kant, K. D. G., Rijkers, G. T., Zimmermann, L. J. I., van Schayck, O. C. P., Heynens, J., Jöbsis, Q., & Dompeling, E. (2009) · Pediatric Allergy and Immunology · doi:10.1111/j.1399-3038.2009.00909.x · Cited by 54
Kotoulas, S., Pataka, A., Domvri, K., Spyratos, D. G., Katsaounou, P. A., Porpodis, Κ., Fouka, E., Markopoulou, A., Passa, K. F., Grigoriou, I., et al. (2020) · Respirology · doi:10.1111/resp.13806 · Cited by 52
Mickleborough, T. D., Vaughn, C. L., Shei, R., Davis, E. M., & Wilhite, D. P. (2013) · Respiratory Medicine · doi:10.1016/j.rmed.2013.04.010 · Cited by 52
Chu, B. H., Kang, B. S., Chang, C., Ren, F., Goh, A., Sciullo, A., Wu, W., Lin, J., Gila, B. P., Pearton, S. J., et al. (2009) · IEEE Sensors Journal · doi:10.1109/jsen.2009.2035213 · Cited by 52
New diagnostic methods for pneumonia in the ICU
Douglas, I. S. (2016) · Current Opinion in Infectious Diseases · doi:10.1097/qco.0000000000000249 · Cited by 53
Lee, A. L., Button, B., Denehy, L., Roberts, S., Bamford, T. L., Mu, F., Mifsud, N. A., Stirling, R. G., & Wilson, J. W. (2014) · Respiratory Care · doi:10.4187/respcare.03570 · Cited by 51
Pulmonary function testing in children and infants
Vogt, B., Falkenberg, C., Weiler, N., & Frerichs, I. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/3/r59 · Cited by 55
“However, the duration of the examination is a limiting factor because the children tend to cooperate less with time (Horvath et al 2005).”
BackgroundInfluentialZhu, X., Zhang, Q., Du, X., Jiang, Y., Niu, Y., Wei, Y., Zhang, Y., Chillrud, S. N., Liang, D., Li, H., et al. (2023) · Environmental Health Perspectives · doi:10.1289/ehp11139 · Cited by 52
Ritz, T., Ayala, E. S., Trueba, A. F., Vance, C. D., & Auchus, R. J. (2011) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201005-0691oc · Cited by 49
Ziętkowski, Z., Skiepko, R., Tomasiak, M. M., & Bodzenta‐Łukaszyk, A. (2010) · Respiration · doi:10.1159/000317137 · Cited by 50
“FEV 1 was evaluated. Before the examination, the patients did not take any medications that could change spirometry results. The highest value from three technically satisfactory attempts was recorded.EBC was collected by using a commercially available condenser (EcoScreen; Erich Jaeger GmbH) according to current Amer…”
MethodWinters, B. R., Pleil, J. D., Angrish, M. M., Stiegel, M. A., Risby, T. H., & Madden, M. C. (2017) · Journal of Breath Research · doi:10.1088/1752-7163/aa8bbc · Cited by 50
Human skin keratins are the major proteins in exhaled breath condensate
Hoffmann, H. J., Tabaksblat, L. M., Enghild, J. J., & Dahl, R. (2008) · European Respiratory Journal · doi:10.1183/09031936.00059707 · Cited by 50
“Exhaled breath condensate (EBC), which has been the subject of a recent American Thoracic Society/European Respiratory Society Task Force [ 2 ], is obtained by collecting condensed liquid from exhaled breath in a cold trap.”
BackgroundExhaled Breath Analysis: From Laboratory Test to Wearable Sensing
Heng, W., Yin, S., Chen, Y., & Gao, W. (2024) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2024.3481360 · Cited by 57
“Furthermore, attention must be paid to the potential degradation of active substances and dilution ratio variations of samples due to differences in temperature and humidity to ensure the accuracy and reliability of the collected data [237].”
Biomarkers in neonatology: the new “omics” of bronchopulmonary dysplasia
Piersigilli, F., & Bhandari, V. (2015) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.3109/14767058.2015.1061495 · Cited by 51
“EBC is a biofluid collected noninvasively by cooling the air expired during tidal breathing [42].”
BackgroundMöller, W., Heimbeck, I., Höfer, T., Saba, G. K., Neiswirth, M., Frankenberger, M., & Ziegler-Heitbrock, L. (2012) · PLoS ONE · doi:10.1371/journal.pone.0033505 · Cited by 52
The clinical utility of biomarkers in asthma and COPD
Snell, N. J. C., & Newbold, P. (2008) · Current Opinion in Pharmacology · doi:10.1016/j.coph.2008.04.001 · Cited by 49
Zhang, X., Zou, Y., An, C., Ying, K., Chen, X., & Wang, P. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.10.139 · Cited by 49
Bowler, R. P., Wendt, C. H., Fessler, M. B., Foster, M. W., Kelly, R. S., Lasky-Su, J. A., Rogers, A. J., Stringer, K. A., & Winston, B. W. (2017) · Annals of the American Thoracic Society · doi:10.1513/annalsats.201710-770ws · Cited by 52
Exhaled breath condensate (EBC) biomarkers in pulmonary fibrosis
Chow, S., Thomas, P. S., Malouf, M. A., & Yates, D. H. (2012) · Journal of Breath Research · doi:10.1088/1752-7155/6/1/016004 · Cited by 49
“EBC was collected using a dedicated refrigeration circuit (Ecoscreen R ©, Erich Jaeger GmbH, Hochberg, Germany) according to ERS/ATS recommendations [17].”
MethodHydrogen peroxide and nitrite reduction in exhaled breath condensate of COPD patients
Stefanska, J., Sarniak, A., Włodarczyk, A., Sokołowska, M., Doniec, Z., Białasiewicz, P., Nowak, D., & Pawliczak, R. (2012) · Pulmonary Pharmacology & Therapeutics · doi:10.1016/j.pupt.2012.06.001 · Cited by 49
Inflammatory markers in childhood asthma
Dodig, S., Richter, D., & Zrinski-Topić, R. (2011) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2011.094 · Cited by 52
Ziętkowski, Z., Tomasiak, M. M., Skiepko, R., Mroczko, B., Szmitkowski, M., & Bodzenta‐Łukaszyk, A. (2008) · Respiratory Medicine · doi:10.1016/j.rmed.2008.10.003 · Cited by 48
“There has been increasing interest in measuring EBC in the assessment of inflammatory biomarkers (both local and systemic) in the pathophysiology and treatment monitoring of asthma.(14) The aim of the study was to assess hs-CRP levels in the EBC of asthmatics with different degrees of disease severity, and to establis…”
BackgroundMethodInfluentialEIA and GC/MS analysis of 8-isoprostane in EBC of children with problematic asthma
Carraro, S., Cogo, P. E., Isak, I., Simonato, M., Corradi, M., Carnielli, V. P., & Baraldi, E. (2009) · European Respiratory Journal · doi:10.1183/09031936.00074909 · Cited by 48
Exhaled breath condensate for lung cancer protein analysis: a review of methods and biomarkers
Hayes, S. A., Haefliger, S., Harris, B. D. W., Pavlakis, N., Clarke, S. J., Molloy, M. P., & Howell, V. M. (2016) · Journal of Breath Research · doi:10.1088/1752-7155/10/3/034001 · Cited by 51
“Although guidelines for EBC collection and biomarker measurement were published by the American Thoracic Society (ATS)/European Respiratory Society (ERS) Task Force in 2005 [20], there is still great variability in published protocols used between laboratories using EBC for proteomic analysis.”
BackgroundMethodInfluentialPersonalized Medicine in Allergy
Ferrando, M., Bagnasco, D., Varricchi, G., Bernardi, S., Bragantini, A., Passalacqua, G., & Canonica, G. W. (2016) · Allergy Asthma and Immunology Research · doi:10.4168/aair.2017.9.1.15 · Cited by 50
“In asthmatic patients, EBC analysis shows increased concentrations of endogenous reactive oxygen species (ROS), adenosine, arachidonic acid metabolites, nitrogen reactive products, ammonia, and pro-inflammatory cytokines.(49) Unfortunately, EBC analysis has not been standardized yet, and we have no guidelines.”
BackgroundMass-Spectrometric Detection of Omega-Oxidation Products of Aliphatic Fatty Acids in Exhaled Breath
Gaugg, M. T., Bruderer, T., Nowak, N., Eiffert, L., Sinues, P., Kohler, M., & Zenobi, R. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b02092 · Cited by 48
8-isoprostane and Leukotrienes in Exhaled Breath Condensate in Czech Subjects with Silicosis
Pelclová, D., Fenclová, Z., Kačer, P., Navrátil, T., Kuzma, M., Lebedová, J., & Klusáčková, P. (2007) · Industrial Health · doi:10.2486/indhealth.45.766 · Cited by 50
Effects of breath holding at low and high lung volumes on amount of exhaled particles
Holmgren, H., Gerth, E., Ljungström, E., Larsson, P., Almstrand, A., Bake, B., & Olin, A. (2012) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2012.10.010 · Cited by 50
Eicosanoids in Exhaled Breath Condensate and BAL Fluid of Patients With Sarcoidosis
Piotrowski, W. J., Antczak, A. J., Marczak, J., Nawrocka, A., Kurmanowska, Z., & Górski, P. (2007) · CHEST Journal · doi:10.1378/chest.07-0215 · Cited by 48
Clinical applications of lung function tests: A revisit
Liang, B., Lam, D. C.-L., & Feng, Y. (2012) · Respirology · doi:10.1111/j.1440-1843.2012.02149.x · Cited by 56
Metabolomics Approach in Allergic and Rheumatic Diseases
Scrivo, R., Casadei, L., Valerio, M., Priori, R., Valesini, G., & Manetti, C. (2014) · Current Allergy and Asthma Reports · doi:10.1007/s11882-014-0445-5 · Cited by 48
Protein profile of exhaled breath condensate determined by high resolution mass spectrometry
Muccilli, V., Saletti, R., Cunsolo, V., Ho, J., Gili, E., Conte, E., Sichili, S., Vancheri, C., & Foti, S. (2014) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2014.11.050 · Cited by 54
Exhaled breath condensate pH as a biomarker of COPD severity in ex-smokers
Papaioannou, A. Ι., Loukides, S., Minas, M., Kontogianni, K., Bakakos, P., Gourgoulianis, K. I., Alchanatis, M., Papiris, S. A., & Κostikas, Κ. (2011) · Respiratory Research · doi:10.1186/1465-9921-12-67 · Cited by 47
“Exhaled breath condensate (EBC) was collected using a commercially available condenser (EcoScreen; Viasys, Hoechberg, Germany) according to the ATS/ERS recommendations [7].”
BackgroundMethodGlück, J., Rymarczyk, B., Kasprzak, M., & Rogala, B. (2016) · International Archives of Allergy and Immunology · doi:10.1159/000444017 · Cited by 50
Santini, G., Mores, N., Shohreh, R., Valente, S., Dabrowska, M. E., Trové, A., Zini, G., Cattani, P., Fuso, L., Mautone, A., et al. (2016) · Journal of Breath Research · doi:10.1088/1752-7155/10/1/017102 · Cited by 47
“All the techniques used for assessing inflammation/oxidative stress are noninvasive, except sputum induction, which is semi-invasive; the methodology used is reliable as PGE2 and 15-F2t-isoprostane were measured with techniques previously validated by GC/MS or HPLC [7,21,22], which are analytical gold standard, wherea…”
MethodSecondary electrospray ionization proceeds via gas-phase chemical ionization
Rioseras, A. T., Gaugg, M. T., & Sinues, P. (2017) · Analytical Methods · doi:10.1039/c7ay01121k · Cited by 49
Exhaled biomarkers in childhood asthma: old and new approaches
Ferraro, V. A., Carraro, S., Bozzetto, S., Zanconato, S., & Baraldi, E. (2018) · Asthma Research and Practice · doi:10.1186/s40733-018-0045-6 · Cited by 50
Zhang, Y., Shen, F., Yang, Y., Niu, M., Chen, D., Chen, L., Wang, S., Zheng, Y., Sun, Y., Zhou, F., et al. (2022) · Environmental Science & Technology · doi:10.1021/acs.est.2c00688 · Cited by 49
Detection of microorganisms in exhaled breath condensate during acute exacerbations of COPD
Zakharkina, T., Koczulla, A. R., Mardanova, O. A., Hattesohl, A., & Bals, R. (2011) · Respirology · doi:10.1111/j.1440-1843.2011.01977.x · Cited by 47
Breath Formate Is a Marker of Airway S-Nitrosothiol Depletion in Severe Asthma
Greenwald, R., Fitzpatrick, A. M., Gaston, B. M., Marozkina, N. V., ERZURUM, S. C., & Teague, W. G. (2010) · PLoS ONE · doi:10.1371/journal.pone.0011919 · Cited by 49
“EBC contains minute quantities of non-volatile material entrained from collapsed menisci of lower airway surface liquids [8,9,10] as well as volatile species that are the product of gas-aqueous phase partitioning anywhere along an exhaled breath flow path [11].”
Beck, O., Sandqvist, S., Eriksen, P. B., Franck, J., & Palmskog, G. (2011) · Journal of Analytical Toxicology · doi:10.1093/anatox/35.3.129 · Cited by 47
Chu, B. H., Kang, B. S., Hung, S. C., Chen, K. H., Ren, F., Sciullo, A., Gila, B. P., & Pearton, S. J. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400122 · Cited by 46
Metabolomics in asthma: A platform for discovery
Xu, S., Panettieri, R. A., & Jude, J. A. (2021) · Molecular Aspects of Medicine · doi:10.1016/j.mam.2021.100990 · Cited by 50
Assessing and accessing the small airways; implications for asthma management
Scichilone, N., Contoli, M., Paleari, D., Pirina, P., Rossi, A., Sanguinetti, C. M., Santus, P., Sofia, M., & Sverzellati, N. (2012) · Pulmonary Pharmacology & Therapeutics · doi:10.1016/j.pupt.2012.10.001 · Cited by 46
Presence of cytokeratins in exhaled breath condensate of mechanical ventilated patients
Geßner, C., Dihazi, H., Brettschneider, S., Hammerschmidt, S., Kühn, H., Eschrich, K., Keller, T., Engelmann, L., Sack, U., & Wirtz, H. R. W. (2007) · Respiratory Medicine · doi:10.1016/j.rmed.2007.08.012 · Cited by 46
“Investigations of EBC most frequently have focused on H2O2, 8-isoprostanes, eicosanoids, and cytokines.(10) Although the quantification of well-known biochemical parameters in various lung diseases is of course worthwhile, the identification of new markers of lung injury is another challenging task.”
BackgroundBraun, P. X., Gmachl, C. F., & Dweik, R. A. (2012) · IEEE Sensors Journal · doi:10.1109/jsen.2012.2210403 · Cited by 46
“This is the same reasoning behind favoring direct analysis of exhaled breath over techniques like collection of exhaled breath condensate (EBC), which, in addition to uncertain clinical effectiveness [84], [85], requires collection and handling by a skilled technician and laboratory analysis; due to its likely expense…”
Background
Metadata
- Authors
- Horváth, I., Hunt, J., & Barnes, P. J.
- Affiliations
- Országos Korányi Tbc és Pulmonológiai Intézet (HU)
- University of Virginia (US)
- Institute of Cancer Research (GB)
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2005-09
- Volume
- 26
- Issue
- 3
- Pages
- 523-548
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W1989935661
- Cited by
- 1,284
- References
- 280
- Citations by year
- 2026: 43 · 2025: 28 · 2024: 35 · 2023: 30 · 2022: 51 · 2021: 43 · 2020: 47 · 2019: 50 · 2018: 53 · 2017: 61 · 2016: 60 · 2015: 68 · 2014: 76 · 2013: 82 · 2012: 107
- FWCI
- 48.86
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- European Respiratory Journal (publishedVersion)
- PubMed (publishedVersion)
- Research Publications (Maastricht University) (publishedVersion, other-oa)
- Publikationsdatenbank der Fraunhofer-Gesellschaft (Fraunhofer-Gesellschaft) (submittedVersion)
- Fraunhofer-Publica (Fraunhofer-Gesellschaft) (submittedVersion)
- Radboud Repository (Radboud University) (submittedVersion)
- OpenAgrar (submittedVersion)
- Padua Research Archive (University of Padova) (submittedVersion)
- Research Publications (Maastricht University) (submittedVersion, other-oa)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Chemical Sensor Technologies
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Asthma and respiratory diseases
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Chronic Obstructive Pulmonary Disease (COPD) Research
- Keywords
- exhaled breath condensate, adenosine, hydrogen peroxide, isoprostanes, leukotrienes, nitrogen oxides, cytokines, reproducibility, longitudinal study, lung disease
- MeSH terms
- Breath Tests, Humans, Lung Diseases, Reproducibility of Results, Biomarkers, Oxidative Stress
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.