Exhaled breath condensate: methodological recommendations and unresolved questions
Open accessThe DOI matches its Crossref record; 281 of the 281 references it cites were found in a registry or an index.
Abstract
Collection of exhaled breath condensate (EBC) is a noninvasive method for obtaining samples from the lungs. EBC contains large number of mediators including adenosine, ammonia, hydrogen peroxide, isoprostanes, leukotrienes, nitrogen oxides, peptides and cytokines. Concentrations of these mediators are influenced by lung diseases and modulated by therapeutic interventions. Similarly EBC pH also changes in respiratory diseases. The aim of the American Thoracic Society/European Respiratory Society Task Force on EBC was to identify the important methodological issues surrounding EBC collection and assay, to provide recommendations for the measurements and to highlight areas where further research is required. Based on the currently available evidence and the consensus of the expert panel for EBC collection, the following general recommendations were put together for oral sample collection: collect during tidal breathing using a noseclip and a saliva trap; define cooling temperature and collection time (10 min is generally sufficient to obtain 1–2 mL of sample and well tolerated by patients); use inert material for condenser; do not use resistor and do not use filter between the subject and the condenser. These are only general recommendations and certain circumstances may dictate variation from them. Important areas for future research involve: ascertaining mechanisms and site of exhaled breath condensate particle formation; determination of dilution markers; improving reproducibility; employment of EBC in longitudinal studies; and determining the utility of exhaled breath condensate measures for the management of individual patients. These studies are required before recommending this technique for use in clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“EBC was obtained approximately 70 min before swimming began and 35 min after swimming ended using an EcoScreen condenser (Jaeger GmbH, Würzburg, Germany) following American Thoracic Society/European Respiratory Society Task Force recommendations (Horvath et al. 2005).”
From Short-Term Changes in Respiratory Biomarkers after Swimming in a Chlorinated Pool (2010) · cites this paper as Horvath et al. 2005
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Brainard, D. H. (1997) · Spatial Vision · doi:10.1163/156856897x00357 · Cited by 19,702
The VideoToolbox software for visual psychophysics: transforming numbers into movies
Pelli, D. G. (1997) · Spatial Vision · doi:10.1163/156856897x00366 · Cited by 11,098
Mixed-Effects Models in S and S-PLUS
(2001) · Technometrics · doi:10.1198/tech.2001.s574 · Cited by 9,278
Best Linear Unbiased Estimation and Prediction under a Selection Model
Henderson, C. R. (1975) · Biometrics · doi:10.2307/2529430 · Cited by 2,497
Metabonomics: a platform for studying drug toxicity and gene function
Nicholson, J. K., Connelly, J., Lindon, J. C., & Holmes, E. (2002) · Nature Reviews Drug Discovery · doi:10.1038/nrd728 · Cited by 1,914
Nonlinear Mixed Effects Models for Repeated Measures Data
Lindstrom, M. J., & Bates, D. M. (1990) · Biometrics · doi:10.2307/2532087 · Cited by 1,795
That BLUP is a Good Thing: The Estimation of Random Effects
Robinson, G. K. (1991) · Statistical Science · doi:10.1214/ss/1177011926 · Cited by 1,686
Effects of antioxidant enzymes in the molecular control of reactive oxygen species toxicology
Matés, >. M. (2000) · Toxicology · doi:10.1016/s0300-483x(00)00306-1 · Cited by 1,518
Peroxynitrite-mediated tyrosine nitration catalyzed by superoxide dismutase
Ischiropoulos, H., Zhu, L., Chen, J., Tsai, M., Martin, J. C., Smith, C. D., & Beckman, J. S. (1992) · Archives of Biochemistry and Biophysics · doi:10.1016/0003-9861(92)90431-u · Cited by 1,495
Research works printed but not linked: 40
- 2002, Am J Respir Crit Care Med, 65, 663
- 1999, Eur Respir Rev, 68, 246
- 1985, Am Rev Respir Dis, 131, 894
- 2002, Eur J Med Res, 7, 353
- 2003, Eur J Med Res, 8, 505
- 1998, Monaldi Arch Chest Dis, 53, 268
- 1999, Eur Respir J, 14, 245
- 10.1002/1615-9861(200206)2:6<690::aid-prot690>3.0.co;2-6 · doi:10.1002/1615-9861(200206)2:6<690::aid-prot690>3.0.co;2-6
- 2000, Monaldi Arch Chest Dis, 55, 185
- 2003, Clin Lab, 49, 637
- 1997, Eur Respir J, 10, 1231
- 1986, Lancet, I, 11
- 1993, Anesth Analg, 77, 963
- 2003, Physiol Res, 52, 327
- 1995, Lancet, 346, 1235
- 10.1053/rmed.2001.1117 · DOI
- 1993, J Pharmacol Exp Ther, 267, 1529
- 1993, Am Rev Respir Dis, 15, 161
- 2002, Int Marit Health, 53, 93
- 1995, Appl Cardiopulmon Pathophysiol, 5, 215
- 10.1164/rccm.200206-507oc · DOI · Paper page
- 2003, Am J Respir Crit Care Med, 167, 91
- 2002, Int J Biol Markers, 17, 141
- 2001, J Heart Lung Transplant, 20, 184
- 1998, Pneumologie, 52, 426
- 2002, Eur J Med Res, 7, 290
- 2002, Curr Opin Pulm Med, 1, 25
- 2002, Int J Occup Med Environ Health, 15, 317
- 2003, Am J Respir Crit Care Med, 168, 1129
- 2004, Undersea Hyperb Med, 31, 217
- 2004, Physiol Res, 53, 561
- 2004, J Chromatogr B Analyt Technol Biomed Life Sci, 809, 199, 10.1016/s1570-0232(04)00513-6 · doi:10.1016/s1570-0232(04)00513-6
- 10.1007/s00408-004-2506-3 · DOI
- 10.1136/vr.155.23.744 · doi:10.1136/vr.155.23.744
- 2004, Thorax, 59, 1005
- 10.1002/rcm.1682 · DOI
- 2004, Physiol Res, 53, 561
- 10.1016/j.jfms.2003.12.002 · DOI
- 2004, Environ Health Perspect, 112, 1293, 10.1289/ehp.7108 · DOI
- 10.1016/s0956-5663(02)00083-0 · DOI · Paper page
Cited by
Items 801–900 of 1,000
Corradi, M., Goldoni, M., Caglieri, A., Folesani, G., Poli, D., Corti, M., & Mutti, A. (2008) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2007.0644 · Cited by 12
“On the basis of this hypothesis, the H 2 O 2 in the first condenser could come partly from directly exhaled H 2 O 2 , the in vivo sources of which are well documented, (23) and partly from the reaction of free radicals during condensation.”
InfluentialCirculating and exhaled vascular endothelial growth factor in asthmatic pregnancy
Bikov, A., Bohács, A., Eszes, N., Weiszhár, Z., Ivancsó, I., Müller, V., Rigó, J. J., Losonczy, G., Tamási, L., & Horváth, I. (2012) · European Respiratory Journal · doi:10.1183/13993003/erj.42.suppl_57.p3548 · Cited by 11
Self-citationLower Limit of Normal Is Better Than 70% or 80%
Hansen, J. E. (2011) · CHEST Journal · doi:10.1378/chest.10-1117 · Cited by 11
Exhaled Breath Analysis Through the Lens of Molecular Communication: A Survey
Bhattacharjee, S., Bi, D., Hofmann, P., Wietfeld, A., Becke, S., Lommel, M., Zhou, P., Zheng, R., Kertzscher, U., Deng, Y., et al. (2025) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2025.3605748 · Cited by 14
“1].”
Exhaled breath condensate in pulmonary arterial hypertension
Warwick, G., Kotlyar, E., Chow, S., Thomas, P. S., & Yates, D. H. (2012) · Journal of Breath Research · doi:10.1088/1752-7155/6/3/036006 · Cited by 11
“1, Jaeger, Germany) according to ERS/ATS recommendations [17] with patients breathing at tidal volume for 10 min.”
BackgroundMethodMarkers of airway inflammation in the exhaled breath condensate of preschool wheezers.
Caballero, S., Martorell, A., Escribano, A., & Belda, J. (2013) · PubMed · Cited by 10
Maskey‐Warzęchowska, M., Nejman‐Gryz, P., Osinka, K., Lis, P., Malesa, K., Górska, K., & Krenke, R. (2016) · Advances in experimental medicine and biology · doi:10.1007/5584_2016_141 · Cited by 10
Mollarasouli, F., Bakırhan, N. K., & Özkan, S. A. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822859-3.00008-0 · Cited by 10
Inflammatory cytokines in exhaled breath condensate in children with inflammatory bowel diseases
Krenke, K., Peradzyńska, J., Lange, J., Banaszkiewicz, A., Łazowska‐Przeorek, I., Grzela, K., Radzikowski, A., & Kulus, M. (2013) · Pediatric Pulmonology · doi:10.1002/ppul.22953 · Cited by 10
“The measurements of cytokine concentration was performed within 3 months from sampling time.(8) Interleukin 6 (IL-6), tumor necrosis factor-a (TNF-a), interleukin-1b (IL-1b), and interleukin 8 (IL-8) were measured using a commercially available enzyme-linked immunoabsorbent assay kit (ELISA) according to the manufactu…”
MethodSánchez‐Vidaurre, S., Cruz, M. J., Gómez‐Ollés, S., Morell, F., & Muñoz, X. (2012) · Annals of Allergy Asthma & Immunology · doi:10.1016/j.anai.2011.12.010 · Cited by 13
Pirozzi, C. S., Sturrock, A., Carey, P., Whipple, S., Haymond, H., Baker, J., Weng, H.-Y., Greene, T., Scholand, M. B., Kanner, R. E., et al. (2015) · COPD Research and Practice · doi:10.1186/s40749-015-0004-z · Cited by 10
“However, these acute changes resolve quickly [26, 37].”
MicroRNA-155 expression in exhaled breath condensate of patients with lung cancer
Ibrahim, F. K., Ali‐Labib, R., Galal, I., & Mahmoud, H. (2017) · Egyptian Journal of Chest Diseases and Tuberculosis · doi:10.1016/j.ejcdt.2017.10.003 · Cited by 10
Swimming versus running: effects on exhaled breath condensate pro-oxidants and pH
Araneda, O. F., Briceño, F. A. C., Cavada, G., & Viscor, G. (2018) · European Journal of Applied Physiology · doi:10.1007/s00421-018-3958-0 · Cited by 10
Diseño y evaluación de un equipo para obtener aire espirado condensado
Araneda, O. F., & Encina, M. P. S. (2009) · Jornal Brasileiro de Pneumologia · doi:10.1590/s1806-37132009000100010 · Cited by 10
Syslová, K., Böhmová, A., Demirbağ, E., Šimková, K., Kuzma, M., Pelclová, D., Sedlák, V., Čáp, P., Pavel Martasek, E., & Kačer, P. (2013) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2013.03.026 · Cited by 10
Effect of Salt-Bromide-Iodine Thermal Water Inhalation on Functional and Biochemical Lung Parameters
Corradi, M., Folesani, G., Gergelová, P., Goldoni, M., Pinelli, S., Gainotti, G., Palma, G. D., & Mutti, A. (2012) · ISRN Pulmonology · doi:10.5402/2012/534290 · Cited by 11
“The increased EBC nitrate levels were expected on the basis of the known enhanced production of nitric oxide oxidative products into airways of diseased subjects [13].”
BackgroundMethodExhaled Breath Condensate Analysis in Chronic Obstructive Pulmonary Disease
Gupta, M., & Chhabra, S. K. (2022) · The Indian Journal of Chest Diseases and Allied Sciences · doi:10.5005/ijcdas-54-1-27 · Cited by 13
Khoubnasabjafari, M., Azarbayjani, A. F., Rahimpour, E., Jouyban‐Gharamaleki, V., Kim, H. Y., Alffenaar, J., Chan, H., & Jouyban, A. (2021) · Journal of Drug Delivery Science and Technology · doi:10.1016/j.jddst.2021.102394 · Cited by 10
Recent Advances in Wide-Bandgap Semiconductor Biological and Gas Sensors
Chu, B. H., Chang, C., Pearton, S. J., Lin, J., & Ren, F. (2011) · CRC Press eBooks · doi:10.1201/b10851-3 · Cited by 10
Increased exhaled nitrite in children with allergic asthma is not related to nitric oxide formation
Zetterquist, W., Marteus, H., Hedlin, G., & Alving, K. (2008) · The Clinical Respiratory Journal · doi:10.1111/j.1752-699x.2008.00057.x · Cited by 10
“In addition, EBC is believed to represent the composition of epithelial lining fluid, and it offers a number of putative markers to study, which could provide a more diversified picture of the airway inflammation (1, 5, 7).”
BackgroundExhaled breath condensate in children: present knowledge and future prospects
Carraro, S., & Baraldi, E. (2008) · Journal of Breath Research · doi:10.1088/1752-7155/2/3/037003 · Cited by 10
Lloberes, P., Sánchez‐Vidaurre, S., Ferré, À., Cruz, M. J., Lorente, J., Sampol, G., Morell, F., & Muñoz, X. (2014) · Archivos de Bronconeumología · doi:10.1016/j.arbres.2014.02.016 · Cited by 10
“con SaO2 < 90% (%) 3,40 (0-24,60) 8,80 (1,2-65,30)”
InfluentialAirway acidification and gastroesophageal reflux
Hunt, J. F., & Gaston, B. M. (2008) · Current Allergy and Asthma Reports · doi:10.1007/s11882-008-0014-x · Cited by 10
Self-citationCondensing Exhaled Breath Into Science
Hunt, J. (2011) · CHEST Journal · doi:10.1378/chest.10-1150 · Cited by 10
Self-citationGaliniak, S., Rohovyk, N., & Rachel, M. (2023) · Advances in Medical Sciences · doi:10.1016/j.advms.2023.05.002 · Cited by 9
Bain, W., Sarma, A. A., Morales‐Nebreda, L., Rizzo, A. N., Herron, M., Wright, S. W., Hagan, R. S., Vigeland, C. L., Mwizerwa, E. L., Pickens, C. I., et al. (2025) · Annals of the American Thoracic Society · doi:10.1513/annalsats.202505-543st · Cited by 11
Noninvasive, MultiOmic, and Multicompartmental Biomarkers of Reflux Disease: A Systematic Review
Farooqi, M. S., Podury, S., Crowley, G., Javed, U., Li, Y., Liu, M., Kwon, S., Grünig, G., Khan, A. R., François, F., et al. (2023) · Gastro Hep Advances · doi:10.1016/j.gastha.2023.01.014 · Cited by 9
“identified in EBC include histamine, adenosine, ammonia and leukotrienes.(62)”
Rai, D., PATTNAIK, B. R., Bangaru, S., Tak, J., Kumari, J., VERMA, U., Vadala, R., Yadav, G., Dhaliwal, R. S., Kumar, S., et al. (2023) · Breathe · doi:10.1183/20734735.0125-2023 · Cited by 10
“At the time of EBC collection, exhaled breath is passed through a cooling system which results in the accumulation of exhaled breath constituents in the liquid phase [19, 33].”
BackgroundKazeminasab, S., Emamalizadeh, B., Jouyban‐Gharamaleki, V., Taghizadieh, A., Khoubnasabjafari, M., & Jouyban, A. (2019) · Nucleosides Nucleotides & Nucleic Acids · doi:10.1080/15257770.2019.1677910 · Cited by 9
“The low concentration of biomarkers in EBC samples and inevitable degradation of them over time [12] justify the necessity of the challenges to achieve the best biobanking protocol.”
BackgroundDesign and Analysis of Exhaled Breath Condenser System for Rapid Collection of Breath Condensate
Ilhamsyah, R., Dimandja, J. D., & Hesketh, P. J. (2021) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ac2be8 · Cited by 9
Isa, K. N. M., Jalaludin, J., Hashim, Z. B., Than, L. T. L., Hashim, J. H., & Norbäck, D. (2022) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2022.158639 · Cited by 9
MEASURE: Multiplex Exhaled Breath Condensate – Scanning Using Rapid Electro-Analytics
Bhide, A., Eldeeb, M. A., Pali, M. L., Muthukumar, S., & Prasad, S. (2023) · ACS Sensors · doi:10.1021/acssensors.3c00693 · Cited by 9
AlGaN/GaN High Electron Mobility Transistor Based Sensors for Bio-Applications
Ren, F., Stephen, J., Sam, B., & Chu, B. H. (2011) · InTech eBooks · doi:10.5772/16693 · Cited by 9
“Exhaled breath is a unique bodily fluid that can be utilized in this regard (Horvath et al. 2005, Namjou, Roller and McCann 2006, Machado et al. 2005, Kullmann et al. 2007, Vaughan et al. 2003, Hunt et al. 2000, Kostikas et al. 2002, Carpagnano et al. 2005, Gessner et al. 2003, Kullmann et al.…”
BackgroundHoffmeyer, F., van Kampen, V., Deckert, A., Neumann, H., Buxtrup, M., Willer, E., Felten, C., Brüning, T., Raulf, M., & Bünger, J. (2015) · Advances in experimental medicine and biology · doi:10.1007/5584_2015_111 · Cited by 9
Evaluation of lung cancer by estimating ferritin in exhaled breath condensate
Ashmawi, S. S., Diab, H. S., & Fahmy, E. A. (2015) · Egyptian Journal of Chest Diseases and Tuberculosis · doi:10.1016/j.ejcdt.2014.08.002 · Cited by 9
Impact of bacterial colonization on exhaled inflammatory markers in wheezing preschool children
van de Kant, K. D. G., Klaassen, E. M. M., van Aerde, K., Damoiseaux, J. G. M. C., Bruggeman, C. A., Stelma, F. F., Stobberingh, E. E., Muris, J. W. M., Jöbsis, Q., van Schayck, O. C. P., et al. (2012) · Journal of Breath Research · doi:10.1088/1752-7155/6/4/046001 · Cited by 9
“Although an American/European Taskforce has listed recommendations regarding the methodology of EBC [49], the technique needs further refinement, standardization and validation.”
MethodCheepsattayakorn, A., & Cheepsattayakorn, R. (2013) · BioMed Research International · doi:10.1155/2013/702896 · Cited by 12
“BAL may provide more information on small airway and alveolar inflammation, but it has variable dilution and invasiveness.”
BackgroundMethodInfluentialLucca, F., Dalt, L. D., Ros, M., Gucciardi, A., Pirillo, P., Naturale, M., Perilongo, G., Giordano, G., & Baraldi, E. (2016) · The Clinical Respiratory Journal · doi:10.1111/crj.12502 · Cited by 12
Chérot‐Kornobis, N., Hulo, S., Giovannelli, J., de Broucker, V., Matran, R., Amouyel, P., Sobaszek, A., Dauchet, L., & Edmé, J. (2018) · Respiratory Medicine · doi:10.1016/j.rmed.2018.03.002 · Cited by 9
du Preez, S., Raidal, S. L., Doran, G., Prescott, M., & Hughes, K. (2018) · Equine Veterinary Journal · doi:10.1111/evj.12979 · Cited by 10
Analysis of manganese and iron in exhaled endogenous particles
Bredberg, A., Ljungkvist, G., Taube, F., Ljungström, E., Larsson, P., Mirgorodskaya, E. E., Isaxon, C., Gudmundsson, A., Forsgard, N., & Olin, A. (2014) · Journal of Analytical Atomic Spectrometry · doi:10.1039/c3ja50381j · Cited by 9
Dowlaty, N., Yoon, A., & Galassetti, P. R. (2013) · Current Opinion in Clinical Nutrition & Metabolic Care · doi:10.1097/mco.0b013e328361f91f · Cited by 9
“ollection tube, cooled to aqueous form, and analyzed by various es [3,4]”
MethodParticulate matter in exhaled breath condensate: A promising indicator of environmental conditions
Pinheiro, T., Barreiros, M. A., Alves, L. C., Félix, P. M., Franco, C., Sousa, J., & Almeida, S. M. (2011) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/j.nimb.2011.02.050 · Cited by 9
Ojanguren, Í., Cruz, M. J., Villar, A., Sánchez-Ortíz, M., Morell, F., & Muñoz, X. (2015) · BMC Pulmonary Medicine · doi:10.1186/s12890-015-0100-5 · Cited by 9
“EBC was collected during tidal breathing with a commercially available condenser (EcoScreen; Jaeger, Würzburg, Germany), as described elsewhere [9].”
BackgroundMethodEarly diagnosis of lung cancer based on proteome analysis of exhaled breath condensate
Fedorchenko, K. Y., Ryabokon, A. M., Kononikhin, A. S., Игоревич, М. С., Barmin, V. V., Пикин, О. В., Anaev, E. K., Владимировна, Г. И., Popov, I. A., Николаев, Е. Н., et al. (2016) · Moscow University Chemistry Bulletin · doi:10.3103/s0027131416020036 · Cited by 9
Effect of freezing on exhaled breath condensate pH
Kullmann, T., Barta, I., & Horváth, I. (2007) · Respiratory Medicine · doi:10.1016/j.rmed.2007.07.013 · Cited by 9
Self-citationRosias, P. P. R., Jöbsis, Q., van de Kant, K. D. G., Robroeks, C. M. H. H. T., van Schayck, O. C. P., Zimmermann, L. J. I., & Dompeling, E. (2008) · European Respiratory Journal · doi:10.1183/09031936.00157907 · Cited by 9
Smart Wearable Devices for Exhaled Breath Condensate Harvesting and Health Monitoring
Qu, Y., Wang, H., Liu, H., Yin, Z., & Xue, Y. (2025) · The FASEB Journal · doi:10.1096/fj.202501736r · Cited by 11
Beyond spirometry: understanding COPD origins to support a new diagnostic approach
Morelli, T., Geeves, M. E., Mohammed, A., Spalluto, C. M., Ackland, J., Freeman, A. T., Ullah, F., Weeks, J., Page, L. K., Kong, A., et al. (2025) · ERJ Open Research · doi:10.1183/23120541.00885-2025 · Cited by 9
“EB contains volatile organic compounds (VOCs) and nonvolatiles (cytokines, peptides, macromolecules and ions) reflecting oxidative stress, inflammation and tissue damage, offering potential biomarkers for diagnosis and patient stratification [78 – 80, 82, 83].”
Connecting the Airways: Current Trends in United Airway Diseases
Bondi, B., Buscema, M., Marco, F. D., Conti, C., Caviglia, A., Fucci, L., Riccio, A., Mincarini, M., Ottoni, M., Braido, F., et al. (2026) · Journal of Personalized Medicine · doi:10.3390/jpm16010021 · Cited by 8
“[63,71], and non-invasive tools (FeNO, exhaled breath condensate) to distinguish type 2 inflammation from the non-type 2 forms [62,65].”
The Effect of Different Periods of Argon Deaeration on Exhaled Breath Condensate pH
Prieto, L. M., Orosa-Bertol, B., Barato, D., & Marín, J. (2011) · Journal of Asthma · doi:10.3109/02770903.2011.560321 · Cited by 8
“Collection of exhaled breath condensate (EBC) is a noninvasive method for obtaining lower respiratory tract samples that can be repeated several times with short intervals between sampling (1).”
BackgroundMethodFila, L., Grandcourtová, A., Chládek, J., & Musil, J. (2013) · Folia Microbiologica · doi:10.1007/s12223-013-0285-z · Cited by 8
“Pulmonary function tests Lung function tests were performed using a Jaeger MasterLab device (Jaeger, Wuerzburg, Germany) according to ERS/ATS guidelines (Miller et al. 2005).”
MethodLi, W., Pi, X., Qiao, P., & Liu, H. (2016) · PLoS ONE · doi:10.1371/journal.pone.0150481 · Cited by 10
Erny, G. L., Gomes, R. A., Santos, M. S. F., Santos, L., Neuparth, N. M. B., Martins, P., Marques, J. G., Guerreiro, A. C. L., & Gomes‐Alves, P. (2020) · ACS Omega · doi:10.1021/acsomega.0c01610 · Cited by 8
Kazeminasab, S., Emamalizadeh, B., Khoubnasabjafari, M., & Jouyban, A. (2020) · Pharmaceutical Sciences · doi:10.34172/ps.2020.46 · Cited by 8
De, S., Khan, Q., Kushwah, G. D. S., Banerjee, N., & Mishra, P. K. (2021) · Journal of Breath Research · doi:10.1088/1752-7163/ac09fa · Cited by 8
“The EBC was collected by TURBO14 (Medivac SRL, Italy) at − 5 ◦ C through disposable non-rebreathing one-way circuits and without wearing nose clips, according to the European Respiratory Society guideline [10].”
Ma, L., Xiu, G., Muscat, J. E., Sinha, R., Sun, D., & Xiu, G. (2021) · Cancer Biomarkers · doi:10.3233/cbm-203269 · Cited by 9
An Efficient Low‐Cost Device for Sampling Exhaled Breath Condensate EBC
Khorshid, M., Sichani, S. B., Estrada, D. L. B., Neefs, W., Clement, A., Pohlmann, G., Epaud, R., Lanone, S., & Wagner, P. (2024) · Advanced Sensor Research · doi:10.1002/adsr.202400020 · Cited by 8
Hoffmeyer, F., Sucker, K., Monsé, C., Berresheim, H., Jettkant, B., Rosenkranz, N., Brüning, T., & Bünger, J. (2014) · Advances in experimental medicine and biology · doi:10.1007/5584_2014_63 · Cited by 8
New techniques for assessment of occupational respiratory diseases
Gergelova, P., Corradi, M., Acampa, O., Goldoni, M., Mutti, A., I., F., Marcinkova, D., & Rusňák, M. (2008) · Bratislavské lekárske listy/Bratislava medical journal · doi:10.1007/bf03657103 · Cited by 9
Kotz, D., van de Kant, K. D. G., Jöbsis, Q., & van Schayck, O. C. P. (2007) · Expert Review of Respiratory Medicine · doi:10.1586/17476348.1.3.403 · Cited by 9
Effect of airway acidosis and alkalosis on airway vascular smooth muscle responsiveness to albuterol
Cançado, J. E. D., Mendes, E. S., Arana, J., Horváth, G., Monzon, M. E., Salathe, M. A., & Wanner, A. (2015) · BMC Pharmacology and Toxicology · doi:10.1186/s40360-015-0008-y · Cited by 8
Palop-Cervera, M., Damiá, A. D. D., Martínez‐Moragón, E., Cortijo, J., Fullana, J., & León, M. (2009) · Archivos de Bronconeumología · doi:10.1016/j.arbres.2009.09.007 · Cited by 8
Assessment of individual lung cancer risk by the proteomic analysis of exhaled breath condensate
Eberini, I., Gianazza, E., Pastorino, U., & Sirtori, C. R. (2008) · Expert Opinion on Medical Diagnostics · doi:10.1517/17530050802600675 · Cited by 8
Bergamaschi, E., Canu, I. G., Prina‐Mello, A., & Magrini, A. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-809199-9.00006-9 · Cited by 12
Schmidt, A. J., Borras, E., Kenyon, N. J., & Davis, C. E. (2020) · Journal of Breath Research · doi:10.1088/1752-7163/abb764 · Cited by 9
“Exhaled breath condensate (EBC) is a fraction of breath that contains water soluble volatiles and non-volatile compounds [8].”
BackgroundRen, F., Chu, B. H., Chen, K., Chang, C., Chen, V., & Pearton, S. J. (2011) · Springer series in materials science · doi:10.1007/978-3-642-23521-4_6 · Cited by 8
Searching for Inflammatory and Oxidative Stress Markers Capable of Clustering Severe Asthma
Carpagnano, G. E., Scioscia, G., Lacedonia, D., Soccio, P., Quarato, C. M. I., Cotugno, G., Palumbo, M. G., & Barbaro, M. P. F. (2021) · Archivos de Bronconeumología · doi:10.1016/j.arbr.2020.04.014 · Cited by 8
Anti-inflammatory effects of pre-seasonal Th1-adjuvant vaccine to Parietaria judaica in asthmatics
Scichilone, N., Minaldi, Santagata, Battaglia, S. L., Camarda, & Bellia (2011) · Journal of Asthma and Allergy · doi:10.2147/jaa.s17784 · Cited by 9
“pH was achieved after de-areation of the EBC specimens by bubbling them with nitrogen at 2 bar for 5 minutes.(12) All samples were analyzed together and each sample was”
MethodTD-GC-MS Investigation of the VOCs Released from Blood Plasma of Dogs with Cancer
Selyanchyn, R., Nozoe, T., Matsui, H., KADOSAWA, T., & Lee, S.-W. (2013) · Diagnostics · doi:10.3390/diagnostics3010068 · Cited by 10
Factor de necrosis tumoral como marcador de inflamación precoz en fumadores sanos
Piña, J. M. D., Fernández‐Aceñero, M. J., Alonso, M. J. L., Lobato, S. D., Alises, S. M., Rodríguez, E. P., Álvarez, D. Á., Horcajada, A. F., & Rojo, R. P. (2012) · Medicina Clínica · doi:10.1016/j.medcli.2011.11.032 · Cited by 9
Determination of ELISA reproducibility to detect protein markers in exhaled breath condensate
Núñez‐Naveira, L., Mariñas‐Pardo, L., Amor-Carro, Ó., & Montero-Martínez, C. (2012) · Journal of Breath Research · doi:10.1088/1752-7155/6/4/046003 · Cited by 8
“But many other markers can be measured in EBC, such as nitrosative stress [4] or eicosanoids and isoprostanes to detect the oxidative stress [10].”
BackgroundExhaled breath condensate collection for nitrite dosage: a safe and low cost adaptation
Reis, G. S., Augusto, V. D. S., Souza, M. E. J., Baldo, C. F., Rodrigues, A. J., & Évora, P. R. B. (2010) · Acta Cirúrgica Brasileira · doi:10.1590/s0102-86502010000200015 · Cited by 8
Čáp, P., Malý, M., Pehal, F., & Pelikan, Z. (2009) · Annals of Allergy Asthma & Immunology · doi:10.1016/s1081-1206(10)60238-4 · Cited by 8
Exhaled bronchial cysteinyl leukotrienes in allergic patients
Failla, M., Crimi, N., & Vancheri, C. (2007) · Current Opinion in Allergy and Clinical Immunology · doi:10.1097/aci.0b013e328012c570 · Cited by 9
Determination of Derivatized Urea in Exhaled Breath Condensate by LC-MS
Quan, Z., Purser, C. A., Baker, R. C., Dwyer, T., Bhagat, R., Sheng, Y., & Leszczyński, J. (2010) · Journal of Chromatographic Science · doi:10.1093/chromsci/48.2.140 · Cited by 8
Sex-based hormonal influences on asthma biomarkers
Jagadish, I., Shah, D., Priessnitz, J. K., & Chiarella, S. E. (2026) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2025.12.1010 · Cited by 8
Seyfinejad, B., Nemutlu, E., Taghizadieh, A., Khoubnasabjafari, M., Özkan, S. A., & Jouyban, A. (2023) · Biomarkers in Medicine · doi:10.2217/bmm-2023-0420 · Cited by 8
Nessen, E., Toussaint, B., Israëls, J., Brinkman, P., der Zee, A. H. M., & Haarman, E. G. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13123372 · Cited by 7
Cannabinoids detected in exhaled breath condensate after cannabis use
Berry, J. L., Brooks‐Russell, A., Beuning, C. N., Limbacher, S. A., Lovestead, T. M., & Jeerage, K. M. (2024) · Journal of Breath Research · doi:10.1088/1752-7163/ad6347 · Cited by 7
“EBC was used historically to explore respiratory diseases like asthma [20, 21] and recently was used to detect oxylipin levels in Covid-19 patients [22].”
MethodUtility of Exhaled Breath Condensate pH for Diagnosing Occupational Asthma
Muñoz, X., Velasco, M. I., Amigo, M. C., Roca, O., Morell, F., & Cruz, M. J. (2012) · International Archives of Allergy and Immunology · doi:10.1159/000338287 · Cited by 7
Tahan, F., & Güngör, H. E. (2016) · Journal of Investigational Allergology and Clinical Immunology · doi:10.18176/jiaci.0003 · Cited by 7
Year in review 2008: Critical Care - respirology
Zhang, H., & Slutsky, A. S. (2009) · Critical Care · doi:10.1186/cc7947 · Cited by 7
del Castillo, A. G., Sánchez‐Vidaurre, S., Simeón‐Aznar, C. P., Cruz, M. J., Fonollosa‐Pla, V., & Muñoz, X. (2016) · Archivos de Bronconeumología · doi:10.1016/j.arbres.2016.09.014 · Cited by 7
Neville, D. M., Fogg, C., Brown, T., Jones, T. L., Lanning, E., Bassett, P., & Chauhan, A. (2018) · JMIR Research Protocols · doi:10.2196/resprot.8768 · Cited by 9
“RenderX has the potential to improve clinical practice by safely providing vital information on aspects of disease that are currently inaccessible [32].”
BackgroundExhaled breath condensate nitrite in premature infants with bronchopulmonary dysplasia
Yen, E., Weinberger, B. I., Laumbach, R. J., Ohman‐Strickland, P., Vetrano, A. M., Gow, A. M., & Ramagopal, M. (2018) · Journal of Neonatal-Perinatal Medicine · doi:10.3233/npm-17106 · Cited by 7
“EBC has been shown to be non-invasive, quick, safe, easy, and feasible, [11] yielding reproducible results on the progression of oxidative and/or inflammatory lung conditions in various patient populations without disturbing underlying pathophysiology [12–14].”
Hayashi, M. A. L., Simon, S., Zou, K., Wyk, H. V., Zahid, M. H., Eisenberg, J. N. S., & Freeman, M. C. (2024) · Risk Analysis · doi:10.1111/risa.17633 · Cited by 7
“10 min of tidal breathing yields 1–3 mL of exhaled breath condensate (Horváth et al., 2005; Hunt, 2002, 2007; Soyer et al., 2006).”
Laboratory Investigations and Immunological Testing in Sarcoidosis
Ahmadzai, H., Paul, S., & Wakefiel, D. (2013) · InTech eBooks · doi:10.5772/55294 · Cited by 8
“Exhaled breath condensate (EBC) analysis is a simple method of sampling airway lining fluids that has been shown to be useful for analysing exhaled breath markers [210-212] and is less invasive compared with induced sputum and BAL.”
MethodBiomarkers of mild hyperthermia related to flashover training in firefighters
Ćalušić, A. L., Mladinić, M., Varnai, V. M., Petrinec, B., Macan, J., Kopjar, N., Ana, L. V., & Želježić, D. (2012) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2012.06.007 · Cited by 9
Levels of Exhaled Breath Condensate pH and Fractional Exhaled Nitric Oxide in Retired Coal Miners
Lee, J.-S., Shin, J.-H., Lee, J.-O., Lee, K.-M., Kim, J. H., & Choi, B.-S. (2010) · Toxicological Research · doi:10.5487/tr.2010.26.4.329 · Cited by 7
“…of various biomarkers in exhaled breath have allowed non-invasive monitoring of inflammation and oxidative stress in respiratory tract in inflammatory lung diseases (Grob et al., 2008; Lehtonen et al., 2007; Goldbart et al., 2006; Horvath et al., 2005; Montuschi, 2005; Kharitonov and Barnes, 2002).”
BackgroundMethodInfluentialDetection of pulmonary amylase activity in exhaled breath condensate
Zweifel, M., Rechsteiner, T. J., Höfer, M., & Boehler, A. (2013) · Journal of Breath Research · doi:10.1088/1752-7155/7/4/046007 · Cited by 7
Somoza, N., & Torà, M. (2009) · Archivos de Bronconeumología · doi:10.1016/s1579-2129(09)71019-5 · Cited by 7
Cathcart, M. P. M., Love, S., Sutton, D. G. M., Reardon, R. J. M., & Hughes, K. (2013) · The Veterinary Journal · doi:10.1016/j.tvjl.2012.12.022 · Cited by 7
Heidemann, S. M., Sandhu, H. S., Kovacevic, N., Phumeetham, S., & Solomon, R. (2011) · Experimental Lung Research · doi:10.3109/01902148.2011.611963 · Cited by 7
“Exhaled breath condensate is a noninvasive method for obtaining fluid from the lung for analysis of mediators [14].”
BackgroundMethodInfluentialDaily life negative mood and exhaled nitric oxide in asthma
Ritz, T., Kullowatz, A., Bill, M. N., & Rosenfield, D. (2016) · Biological Psychology · doi:10.1016/j.biopsycho.2016.06.001 · Cited by 7
Eicosanoids in exhaled breath condensate of airway inflammation in patients with asthma
Takaku, Y., Kurashima, K., Kobayashi, T., Nakagome, K., & Nagata, M. (2016) · Allergology International · doi:10.1016/j.alit.2016.05.007 · Cited by 7
Increased Interleukin-6 (IL-6) in Exhaled Breath Condensate of Asthmatic Children
Linares-Segovia, B., Sandoval, G. C., & Pacheco, F. D. R. E. (2016) · Archivos de Bronconeumología · doi:10.1016/j.arbr.2016.06.031 · Cited by 7
The effect of space flight on the protein composition of the exhaled breath condensate of cosmonauts
Fedorchenko, K. Y., Ryabokon, A. M., Kononikhin, A. S., Игоревич, М. С., Mikhant’eva, E. A., Спасский, А. И., Sukhodolov, I. R., Popov, I. A., Polyakov, A. V., Larina, I. M., et al. (2016) · Russian Chemical Bulletin · doi:10.1007/s11172-016-1645-z · Cited by 7
Kurowski, M. M., Jurczyk, J., Olszewska-Ziąber, A., Jarzębska, M., Krysztofiak, H., & Kowalski, M. L. (2017) · Advances in Medical Sciences · doi:10.1016/j.advms.2017.07.004 · Cited by 8
“EBC samples were obtained using a Turbo DECCS (Disposable Exhaled Condensate Collection System) 09 device (Medivac di Romei Vanna, Parma, Italy) immediately before and 30 min after exercise challenge in accordance with the current recommendations [26,27] as described previously [11,13].”
MethodCorradi, M., Folesani, G., Robuschi, B., Selis, L., Riccelli, M. G., Andreoli, R., Pisi, R., Chetta, A. A., & Mutti, A. (2019) · La Medicina del Lavoro · doi:10.23749/mdl.v110i2.7471 · Cited by 7
“The condenser respected all of the recommended practical standards and anti-contamination principles for EBC collection published by the ATS/ERS (26), and its temperature was set at -5°C.”
Background
Metadata
- Authors
- Horváth, I., Hunt, J., & Barnes, P. J.
- Affiliations
- Országos Korányi Tbc és Pulmonológiai Intézet (HU)
- University of Virginia (US)
- Institute of Cancer Research (GB)
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2005-09
- Volume
- 26
- Issue
- 3
- Pages
- 523-548
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W1989935661
- Cited by
- 1,284
- References
- 280
- Citations by year
- 2026: 43 · 2025: 28 · 2024: 35 · 2023: 30 · 2022: 51 · 2021: 43 · 2020: 47 · 2019: 50 · 2018: 53 · 2017: 61 · 2016: 60 · 2015: 68 · 2014: 76 · 2013: 82 · 2012: 107
- FWCI
- 48.86
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- European Respiratory Journal (publishedVersion)
- PubMed (publishedVersion)
- Research Publications (Maastricht University) (publishedVersion, other-oa)
- Publikationsdatenbank der Fraunhofer-Gesellschaft (Fraunhofer-Gesellschaft) (submittedVersion)
- Fraunhofer-Publica (Fraunhofer-Gesellschaft) (submittedVersion)
- Radboud Repository (Radboud University) (submittedVersion)
- OpenAgrar (submittedVersion)
- Padua Research Archive (University of Padova) (submittedVersion)
- Research Publications (Maastricht University) (submittedVersion, other-oa)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Chemical Sensor Technologies
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Asthma and respiratory diseases
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Chronic Obstructive Pulmonary Disease (COPD) Research
- Keywords
- exhaled breath condensate, adenosine, hydrogen peroxide, isoprostanes, leukotrienes, nitrogen oxides, cytokines, reproducibility, longitudinal study, lung disease
- MeSH terms
- Breath Tests, Humans, Lung Diseases, Reproducibility of Results, Biomarkers, Oxidative Stress
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.