Exhaled breath condensate: methodological recommendations and unresolved questions
Open accessThe DOI matches its Crossref record; 281 of the 281 references it cites were found in a registry or an index.
Abstract
Collection of exhaled breath condensate (EBC) is a noninvasive method for obtaining samples from the lungs. EBC contains large number of mediators including adenosine, ammonia, hydrogen peroxide, isoprostanes, leukotrienes, nitrogen oxides, peptides and cytokines. Concentrations of these mediators are influenced by lung diseases and modulated by therapeutic interventions. Similarly EBC pH also changes in respiratory diseases. The aim of the American Thoracic Society/European Respiratory Society Task Force on EBC was to identify the important methodological issues surrounding EBC collection and assay, to provide recommendations for the measurements and to highlight areas where further research is required. Based on the currently available evidence and the consensus of the expert panel for EBC collection, the following general recommendations were put together for oral sample collection: collect during tidal breathing using a noseclip and a saliva trap; define cooling temperature and collection time (10 min is generally sufficient to obtain 1–2 mL of sample and well tolerated by patients); use inert material for condenser; do not use resistor and do not use filter between the subject and the condenser. These are only general recommendations and certain circumstances may dictate variation from them. Important areas for future research involve: ascertaining mechanisms and site of exhaled breath condensate particle formation; determination of dilution markers; improving reproducibility; employment of EBC in longitudinal studies; and determining the utility of exhaled breath condensate measures for the management of individual patients. These studies are required before recommending this technique for use in clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“EBC was obtained approximately 70 min before swimming began and 35 min after swimming ended using an EcoScreen condenser (Jaeger GmbH, Würzburg, Germany) following American Thoracic Society/European Respiratory Society Task Force recommendations (Horvath et al. 2005).”
From Short-Term Changes in Respiratory Biomarkers after Swimming in a Chlorinated Pool (2010) · cites this paper as Horvath et al. 2005
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Brainard, D. H. (1997) · Spatial Vision · doi:10.1163/156856897x00357 · Cited by 19,702
The VideoToolbox software for visual psychophysics: transforming numbers into movies
Pelli, D. G. (1997) · Spatial Vision · doi:10.1163/156856897x00366 · Cited by 11,098
Mixed-Effects Models in S and S-PLUS
(2001) · Technometrics · doi:10.1198/tech.2001.s574 · Cited by 9,278
Best Linear Unbiased Estimation and Prediction under a Selection Model
Henderson, C. R. (1975) · Biometrics · doi:10.2307/2529430 · Cited by 2,497
Metabonomics: a platform for studying drug toxicity and gene function
Nicholson, J. K., Connelly, J., Lindon, J. C., & Holmes, E. (2002) · Nature Reviews Drug Discovery · doi:10.1038/nrd728 · Cited by 1,914
Nonlinear Mixed Effects Models for Repeated Measures Data
Lindstrom, M. J., & Bates, D. M. (1990) · Biometrics · doi:10.2307/2532087 · Cited by 1,795
That BLUP is a Good Thing: The Estimation of Random Effects
Robinson, G. K. (1991) · Statistical Science · doi:10.1214/ss/1177011926 · Cited by 1,686
Effects of antioxidant enzymes in the molecular control of reactive oxygen species toxicology
Matés, >. M. (2000) · Toxicology · doi:10.1016/s0300-483x(00)00306-1 · Cited by 1,518
Peroxynitrite-mediated tyrosine nitration catalyzed by superoxide dismutase
Ischiropoulos, H., Zhu, L., Chen, J., Tsai, M., Martin, J. C., Smith, C. D., & Beckman, J. S. (1992) · Archives of Biochemistry and Biophysics · doi:10.1016/0003-9861(92)90431-u · Cited by 1,495
Research works printed but not linked: 40
- 2002, Am J Respir Crit Care Med, 65, 663
- 1999, Eur Respir Rev, 68, 246
- 1985, Am Rev Respir Dis, 131, 894
- 2002, Eur J Med Res, 7, 353
- 2003, Eur J Med Res, 8, 505
- 1998, Monaldi Arch Chest Dis, 53, 268
- 1999, Eur Respir J, 14, 245
- 10.1002/1615-9861(200206)2:6<690::aid-prot690>3.0.co;2-6 · doi:10.1002/1615-9861(200206)2:6<690::aid-prot690>3.0.co;2-6
- 2000, Monaldi Arch Chest Dis, 55, 185
- 2003, Clin Lab, 49, 637
- 1997, Eur Respir J, 10, 1231
- 1986, Lancet, I, 11
- 1993, Anesth Analg, 77, 963
- 2003, Physiol Res, 52, 327
- 1995, Lancet, 346, 1235
- 10.1053/rmed.2001.1117 · DOI
- 1993, J Pharmacol Exp Ther, 267, 1529
- 1993, Am Rev Respir Dis, 15, 161
- 2002, Int Marit Health, 53, 93
- 1995, Appl Cardiopulmon Pathophysiol, 5, 215
- 10.1164/rccm.200206-507oc · DOI · Paper page
- 2003, Am J Respir Crit Care Med, 167, 91
- 2002, Int J Biol Markers, 17, 141
- 2001, J Heart Lung Transplant, 20, 184
- 1998, Pneumologie, 52, 426
- 2002, Eur J Med Res, 7, 290
- 2002, Curr Opin Pulm Med, 1, 25
- 2002, Int J Occup Med Environ Health, 15, 317
- 2003, Am J Respir Crit Care Med, 168, 1129
- 2004, Undersea Hyperb Med, 31, 217
- 2004, Physiol Res, 53, 561
- 2004, J Chromatogr B Analyt Technol Biomed Life Sci, 809, 199, 10.1016/s1570-0232(04)00513-6 · doi:10.1016/s1570-0232(04)00513-6
- 10.1007/s00408-004-2506-3 · DOI
- 10.1136/vr.155.23.744 · doi:10.1136/vr.155.23.744
- 2004, Thorax, 59, 1005
- 10.1002/rcm.1682 · DOI
- 2004, Physiol Res, 53, 561
- 10.1016/j.jfms.2003.12.002 · DOI
- 2004, Environ Health Perspect, 112, 1293, 10.1289/ehp.7108 · DOI
- 10.1016/s0956-5663(02)00083-0 · DOI · Paper page
Cited by
Items 301–400 of 1,000
Exhaled breath condensate: lessons learned from veterinary medicine
Reinhold, P., & Knobloch, H. (2009) · Journal of Breath Research · doi:10.1088/1752-7155/4/1/017001 · Cited by 46
Biomarkers of therapy responsiveness in asthma: pitfalls and promises
Vijverberg, S. J. H., Koenderman, L., Koster, E. S., van der Ent, C. K., Raaijmakers, J. A. M., & der Zee, A. H. M. (2011) · Clinical & Experimental Allergy · doi:10.1111/j.1365-2222.2011.03694.x · Cited by 45
Biomarkers of lung damage associated with tobacco smoke in induced sputum
Comandini, A., Rogliani, P., Nunziata, A., Cazzola, M., Curradi, G., & Saltini, C. (2009) · Respiratory Medicine · doi:10.1016/j.rmed.2009.06.002 · Cited by 51
García‐Gómez, D., Bregy, L., Nussbaumer‐Ochsner, Y., Gaisl, T., Kohler, M., & Zenobi, R. (2015) · Environmental Science & Technology · doi:10.1021/acs.est.5b03809 · Cited by 47
The Use of Breath Analysis in the Management of Lung Cancer: Is It Ready for Primetime?
Keogh, R. J., & Riches, J. C. (2022) · Current Oncology · doi:10.3390/curroncol29100578 · Cited by 46
“The ATS/ERS expert panel recommends the use of a nose clip during breath sample collection to avoid loss of sample through the nose and so inspiration bypasses the nose [53].”
BackgroundInfluentialColombo, C., Faelli, N., Tirelli, A. S., Fortunato, F., Biffi, A., Claut, L. E., Cariani, L., Daccò, V., Prato, R., & Conese, M. (2011) · International Journal of Immunopathology and Pharmacology · doi:10.1177/039463201102400215 · Cited by 46
“EBC collection was in agreement ofAmerican Thoracic Society (ATS)/European Respiratory Society (ERS) recommendations (16).”
ResultMalerba, M., Damiani, G. B., Radaeli, A., Ragnoli, B., Olivini, A., & Calzavara‐Pinton, P. (2015) · British Journal of Dermatology · doi:10.1111/bjd.13988 · Cited by 46
Airway acidification in childhood asthma exacerbations
Caffarelli, C., Dascola, C. P., Peroni, D. G., Ricò, S., Stringari, G., Varini, M., Folesani, G., & Corradi, M. (2014) · Allergy and Asthma Proceedings · doi:10.2500/aap.2014.35.3740 · Cited by 44
“The collection is simple to perform and easy to repeat in healthy and unhealthy children.(1,2) There is emerging evidence that biomarkers of airway inflammation and oxidative stress in EBC reflected changes in the airway lining fluid and are altered both in pulmonary and nonpulmonary diseases.”
BackgroundReder, N. P., Davis, C. S., Kovacs, E. J., & Fisichella, P. M. (2014) · Surgical Endoscopy · doi:10.1007/s00464-013-3388-3 · Cited by 44
“The EBC collection was performed per protocol [8] in the Bronchoscopy Suite using a condenser (RTube; Respira-”
MethodDetection of occult lung impairment in welders by induced sputum particles and breath oxidation
Fireman, E. M., Lerman, Y., Stark, M., Schwartz, Y., Ganor, E., Grinberg, N., Frimer, R., Landau, D. A., Zilberberg, M., Barenboim, E., et al. (2008) · American Journal of Industrial Medicine · doi:10.1002/ajim.20586 · Cited by 50
“They breathed tidally for 20 min under supervised conditions according to European Respiratory Society recommendations [Horvath et al., 2005].”
MethodPelclová, D., Ždímal, V., Kačer, P., Fenclová, Z., Vlčková, Š., Komarc, M., Navrátil, T., Schwarz, J., Zíková, N., Makeš, O., et al. (2016) · Journal of Breath Research · doi:10.1088/1752-7155/10/3/036004 · Cited by 48
“A constant collection time of 15 min and/or minimum volume of 120 l of exhaled air were maintained [38].”
BackgroundHe, L., Cui, X., Li, Z., Teng, Y., Barkjohn, K. K., Norris, C. L., Fang, L., Lin, L., Wang, Q., Zhou, X., et al. (2020) · Environmental Science & Technology · doi:10.1021/acs.est.0c02558 · Cited by 45
Inflammatory Biomarkers in Exhaled Breath Condensate: A Systematic Review
Ghelli, F., Panizzolo, M., Garzaro, G., Squillacioti, G., Bellisario, V., Colombi, N., Bergamaschi, E., Canu, I. G., & Bono, R. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms23179820 · Cited by 46
“The methodological assessment was based on compliance with the guidelines issued by the American Thoracic Society/European Respiratory Society Task Force in 2005 and 2015 [20,21].”
BackgroundMethodInfluentialCaffarelli, C., Calcinai, E., Rinaldi, L., Dascola, C. P., Terracciano, L., & Corradi, M. (2012) · Respiration · doi:10.1159/000341969 · Cited by 48
Zou, Y., Wang, L., Zhao, C., Hu, Y., Xu, S., Ying, K., Wang, P., & Chen, X. (2013) · Journal of Breath Research · doi:10.1088/1752-7155/7/4/047101 · Cited by 45
“Different detection methods and sampling conditions (such as duration, ambient air and breath pattern) may affect the results [17].”
BackgroundŘihák, V., Zatloukal, P., Chládková, J., Zimulová, A., Havlínová, Z., & Chládek, J. (2010) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.20408 · Cited by 45
“Noninvasive profiling of inflammatory biomarkers in EBC could help to classify the severity and type of inflammation in acute and chronic asthma, chronic obstructive pulmonary disease, and other lung diseases, and could be used for diagnosis and monitoring of therapy of these diseases (7).”
BackgroundExhaled breath condensate – from an analytical point of view
Dodig, S., & Čepelak, I. (2013) · Biochemia Medica · doi:10.11613/bm.2013.034 · Cited by 44
Exhaled breath condensate as bioanalyte: from collection considerations to biomarker sensing
Szunerits, S., Doerfler, H., Pagneux, Q., Daniel, J., Wadekar, S., Woitrain, E., Ladage, D., Montaigne, D., & Boukherroub, R. (2022) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-022-04433-5 · Cited by 43
“Collecting such respiratory droplets as EBC is achieved by cooling the air exhaled by an object [13, 16, 17] and results in the collection of non-volatile biomarkers for analysis using a range of established analytical techniques.”
MethodMenopausal asthma: a new biological phenotype?
Barbaro, M. P. F., Costa, V., Resta, O., Prato, R., Spanevello, A., Palladino, G. P., Martinelli, D., & Carpagnano, G. E. (2010) · Allergy · doi:10.1111/j.1398-9995.2009.02314.x · Cited by 43
“An increasing interest in the study of the airways inflammation is currently being aroused by two new techniques that allow for a noninvasive sampling from the airways: breath condensate and induced sputum (27, 28).”
BackgroundImpact Of Age on pH, 8-Isoprostane, and Nitrogen Oxides in Exhaled Breath Condensate
Cruz, M. J., Sánchez‐Vidaurre, S., Romero, P.-V., Morell, F., & Muñoz, X. (2008) · CHEST Journal · doi:10.1378/chest.08-1007 · Cited by 43
Validation of assays for inflammatory mediators in exhaled breath condensate
Bayley, D., Abusriwil, H., Ahmad, A., & STOCKLEY, R. A. (2008) · European Respiratory Journal · doi:10.1183/09031936.00081707 · Cited by 43
Exhaled Breath Condensate pH Assays
Hunt, J. (2007) · Immunology and Allergy Clinics of North America · doi:10.1016/j.iac.2007.09.006 · Cited by 43
Self-citationBreath biomarkers in toxicology
Pleil, J. D. (2016) · Archives of Toxicology · doi:10.1007/s00204-016-1817-5 · Cited by 45
“EBA is a subset of EBC and is extracted from total EBC, or collected directly using filter materials or particle impingers to capture bacteria, protein fragments, cell fragments, and other particulates directly and exclude gases and vapors (Holmgren et al. 2010; Horvath et al. 2005).”
MethodCelio, S., Troxler, H., Durka, S., Chládek, J., Wildhaber, J. H., Sennhauser, F. H., Heizmann, C. W., & Mœller, A. (2006) · Nitric Oxide · doi:10.1016/j.niox.2006.06.008 · Cited by 43
Reinhold, P., Kirschvink, N. A., Theegarten, D., & Berndt, A. (2008) · Veterinary Research · doi:10.1051/vetres:2008012 · Cited by 52
“mediators measurable in EBC has been described as being influenced by several diseases of airways or lung parenchyma [17, 31] its diagnostic potentials and limitations have yet to be defined in both human and veterinary medicine [11].”
BackgroundExhaled breath condensate biomarkers in asbestos-related lung disorders
Chow, S., Campbell, C., Sandrini, A., Thomas, P. S., Johnson, A., & Yates, D. H. (2009) · Respiratory Medicine · doi:10.1016/j.rmed.2009.04.009 · Cited by 43
Th-17 cytokines and interstitial lung involvement in systemic sclerosis
Rolla, G., Fusaro, E., Nicola, S., Bucca, C. B., Peroni, C. L., Parisi, S., Cassinis, M. C., Ferraris, A., Angelino, F., Heffler, E. M., et al. (2016) · Journal of Breath Research · doi:10.1088/1752-7155/10/4/046013 · Cited by 42
“were normalized to the protein concentrations [15].”
Górska, K., Nejman‐Gryz, P., Paplińska‐Goryca, M., Korczyński, P., Prochorec‐Sobieszek, M., & Krenke, R. (2018) · COPD Journal of Chronic Obstructive Pulmonary Disease · doi:10.1080/15412555.2017.1416074 · Cited by 42
“Exhaled breath condensate (EBC) was collected with the use of the TURBO-DECCS 09 system (Medivac, Parma, Italy) in concordance with ATS/ERS recommendations (29).”
Evaluation of H2O2and pH in exhaled breath condensate samples: methodical and physiological aspects
Knobloch, H., Becher, G., Decker, M., & Reinhold, P. (2008) · Biomarkers · doi:10.1080/13547500701831440 · Cited by 42
“…et al. 1993, van Beurden et al. 320 H. Knobloch et al. 2003) indicating that standardization of both EBC collection and analytical tests applied to EBC samples are actually the biggest problems concerning incoherent results and their interpretations (Rahman & Biswas 2004, Horváth et al. 2005).”
BackgroundPeroni, D. G., Bodini, A., Corradi, M., Coghi, A., Boner, A. L., & PIACENTINI, G. L. (2012) · British Journal of Dermatology · doi:10.1111/j.1365-2133.2011.10771.x · Cited by 45
García‐de‐la‐Asunción, J., Bruno, L., Perez-Griera, J., Galán, G., Aixelá, A. M., Wins, R., del Olmo, E. G., Guijarro, R., Sarriá, B., Martí, F., et al. (2017) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000002065 · Cited by 45
Metabolic effects of inhaled salbutamol determined by exhaled breath analysis
Gaugg, M. T., Engler, A., Nussbaumer‐Ochsner, Y., Bregy, L., Lang-Stöberl, A. S., Gaisl, T., Bruderer, T., Zenobi, R., Kohler, M., & Sinues, P. (2017) · Journal of Breath Research · doi:10.1088/1752-7163/aa7caa · Cited by 45
“EBCwas collected using a sampling device constructed in-house following the guidelines set by the ATS/ERS task force [27].”
MethodEffects of psychosocial stress on the pattern of salivary protein release
Trueba, A. F., Mizrachi, D., Auchus, R. J., Vogel, P. D., & Ritz, T. (2011) · Physiology & Behavior · doi:10.1016/j.physbeh.2011.10.014 · Cited by 44
“and the more central airways [70], it will ultimately be desirable to also sample mucosal proteins with techniques such as exhaled breath condensate [71,72] that reach into the central airways.”
BackgroundCarraro, S., Giordano, G., Pirillo, P., Maretti, M., Reniero, F., Cogo, P. E., Perilongo, G., Stocchero, M., & Baraldi, E. (2014) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2014.08.049 · Cited by 41
Expression of priming-associated cellular markers on neutrophils during an exacerbation of COPD
Oudijk, E. D., Gerritsen, W. B., Nijhuis, E. H. J., Kanters, D. H. A. J., Maesen, B. L. P., Lammers, J. J., & Koenderman, L. (2006) · Respiratory Medicine · doi:10.1016/j.rmed.2006.01.022 · Cited by 47
Chiral separation of methadone in exhaled breath condensate using capillary electrophoresis
Hamidi, S., Khoubnasabjafari, M., Ansarin, K., Jouyban‐Gharamaleki, V., & Jouyban, A. (2017) · Analytical Methods · doi:10.1039/c7ay00110j · Cited by 43
Sabeti, Z., Ansarin, K., Seyedrezazadeh, E., Jafarabadi, M. A., Zafari, V., Dastgiri, S., Shakerkhatibi, M., Gholampour, A., Khamnian, Z., Sepehri, M., et al. (2021) · Environmental Pollution · doi:10.1016/j.envpol.2021.117797 · Cited by 41
Gastroesophageal Reflux and Idiopathic Pulmonary Fibrosis: A Prospective Study
Fahim, A., Dettmar, P. W., Morice, A. H., & Hart, S. P. (2011) · Medicina · doi:10.3390/medicina47040028 · Cited by 41
“The collection of exhaled breath was performed according to the guidelines recommended by the ERS/ATS task force (19).”
Exhaled breath analysis, a simple tool to study the pathophysiology of obstructive sleep apnoea
Bikov, A., Hull, J. H., & Kunos, L. (2015) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2015.07.005 · Cited by 41
Han, K., Mekala, K. C., Babida, V., Kim, H. Y., Handlogten, M. E., Verlander, J. W., & Weiner, I. D. (2009) · American Journal of Physiology-Lung Cellular and Molecular Physiology · doi:10.1152/ajplung.90524.2008 · Cited by 41
Peel, A. M., Wilkinson, M., Sinha, A., Loke, Y. K., Fowler, S. J., & Wilson, A. M. (2020) · Respiratory Medicine · doi:10.1016/j.rmed.2020.105984 · Cited by 40
“In common with other emergent fields of study (94) there is a conflict between innovation and standardisation.”
Ionic determinants of exhaled breath condensate pH before and after exercise in adolescent athletes
Greenwald, R., Ferdinands, J. M., & Teague, W. G. (2009) · Pediatric Pulmonology · doi:10.1002/ppul.21055 · Cited by 40
“Gas standardization by sparging with a CO2-free gas has been recommended as a means to stabilize the pH of EBC samples.(1,2,4,5,9,12) However, this deaeration process also removes other dissolved gases such as O2 and volatile species such as ammonia and acetic acid.”
Pappas, L. K., & Filippatos, G. (2011) · Revista Española de Cardiología · doi:10.1016/j.recesp.2011.05.006 · Cited by 40
Nording, M. L., Yang, J., Hegedus, C. M., Bhushan, A., Kenyon, N. J., Davis, C. E., & Hammock, B. D. (2009) · IEEE Sensors Journal · doi:10.1109/jsen.2009.2035736 · Cited by 40
Pharmacokinetics and tolerability of oral sildenafil in adults with cystic fibrosis lung disease
Taylor‐Cousar, J. L., Wiley, C. J., Felton, L. A., Clair, C. S., Jones, M. C., Curran‐Everett, D., Poch, K. R., Nichols, D. P., Solomon, G. M., Saavedra, M. T., et al. (2014) · Journal of Cystic Fibrosis · doi:10.1016/j.jcf.2014.10.006 · Cited by 40
“Exhaled breath condensate was collected using R-tubes (Respiratory Research Institute) by ATS recommended technique [29].”
MethodRecent Progress of Exhaled Gas‐Based Diagnosis Based on Field Effect Transistor Sensors
Lu, G., Ji, T., He, S., Ai, F., Yan, L., & Hu, J. (2024) · Advanced Functional Materials · doi:10.1002/adfm.202309111 · Cited by 49
Assessment of pulmonary oxygen toxicity: Relevance to professional diving; a review
van Ooij, P.-J. A., Hollmann, M. W., van Hulst, R. A., & Sterk, P. J. (2013) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2013.07.014 · Cited by 39
Exhaled NO and breath condensate
Baraldi, E., & Carraro, S. (2006) · Paediatric Respiratory Reviews · doi:10.1016/j.prrv.2006.04.017 · Cited by 41
Non-invasive biomarkers and pulmonary function in smokers
Borrill, Z., Roy, K., Vessey, R. S., Woodcock, A. A., & Singh, D. (2008) · International Journal of COPD · doi:10.2147/copd.s1850 · Cited by 39
Tecklenburg-Lund, S., Mickleborough, T. D., Turner, L. A., Fly, A. D., Stager, J. M., & Montgomery, G. S. (2010) · PLoS ONE · doi:10.1371/journal.pone.0013487 · Cited by 39
“EBC samples were collected with a specially designed condensing chamber (ECoScreen, Jaeger, Hoechberg, Germany) using ATS/ERS recommendations [30].”
MethodGhosh, N., Choudhury, P., Joshi, M. V., Bhattacharyya, P., Roychowdhury, S., Banerjee, R., & Chaudhury, K. (2021) · Scientific Reports · doi:10.1038/s41598-021-96128-7 · Cited by 40
Iron and Ferritin Concentrations in Exhaled Breath Condensate of Children with Asthma
Vlašić, Ž., Dodig, S., Čepelak, I., Topić, R. Z., Živčić, J., Nogalo, B., & Turkalj, M. (2009) · Journal of Asthma · doi:10.1080/02770900802513007 · Cited by 39
“EBC was collected according to the ATS/ERS Task Force recommendation (16) using an EcoScreen condenser (Erich Jaeger GmbH, Hoechberg, Germany).”
MethodAnalytical methodologies for broad metabolite coverage of exhaled breath condensate
Aksenov, A. A., Zamuruyev, K. O., Pasamontes, A., Brown, J. F., Schivo, M., Foutouhi, S., Weimer, B. C., Kenyon, N. J., & Davis, C. E. (2017) · Journal of Chromatography B · doi:10.1016/j.jchromb.2017.06.038 · Cited by 42
“Liquid EBC samples have an advantage that they can be stored for extended periods of time under cryogenic conditions without apparent loss of metabolite content [21,24].”
BackgroundExhaled Biomarkers for Point-of-Care Diagnosis: Recent Advances and New Challenges in Breathomics
Kiss, H., Örlős, Z., Gellert, Á., Megyesfalvi, Z., Mikáczó, A., Sárközi, A. T., Vaskó, A., Miklós, Z., & Horváth, I. (2023) · Micromachines · doi:10.3390/mi14020391 · Cited by 42
Self-citationCao, Y., Shi, H., Zheng, Y., Tan, Z., Xie, Z., Zhang, C., & Chen, Z. (2023) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2023.134189 · Cited by 38
van Vliet, D., Alonso, A., Rijkers, G. T., Heynens, J., Rosias, P. P. R., Muris, J. W. M., Jöbsis, Q., & Dompeling, E. (2015) · PLoS ONE · doi:10.1371/journal.pone.0119434 · Cited by 38
“From collection to chemical analysis freeze-thaw cycles were avoided [18].”
BackgroundSecondhand smoke exposure induces acutely airway acidification and oxidative stress
Κostikas, Κ., Minas, M., Nikolaou, E., Papaioannou, A. Ι., Liakos, P., Gougoura, S. G., Gourgoulianis, K. I., Dinas, P. C., Metsios, G. S., Jamurtas, A. Z., et al. (2012) · Respiratory Medicine · doi:10.1016/j.rmed.2012.10.017 · Cited by 41
“The first aliquot was used for the measurement of EBC pH, immediately after EBC collection as previously described.(22) Stable pH was achieved after deaeration with an inert gas (argon, 350 ml/min for 10 min) and was measured using a commercially available pH meter (Model 3510, Jenway, Essex, UK).”
MethodRecent advances in asthma biomarker research
Leung, T. F., Ko, F. W. S., & Wong, G. (2013) · Therapeutic Advances in Respiratory Disease · doi:10.1177/1753465813496863 · Cited by 39
Chen, D., Bryden, W. A., & Wood, R. (2020) · Scientific Reports · doi:10.1038/s41598-020-64637-6 · Cited by 38
Ursini, C. L., Fresegna, A. M., Ciervo, A., Maiello, R., Frate, V. D., Folesani, G., Galetti, M., Poli, D., Buresti, G., Cristo, L. D., et al. (2020) · Nanotoxicology · doi:10.1080/17435390.2020.1850903 · Cited by 41
Paro, M. L. Z., Bussamra, M. H. C. F., Saraiva-Romanholo, B. M., Martins, M. A., Okay, T. S., & Rodrigues, J. C. (2007) · Pediatric Pulmonology · doi:10.1002/ppul.20747 · Cited by 40
“EBC is certainly the less invasive technique for monitoring airway inflammation, however, standardized techniques to analyze the sample are not available.(4) Inflammation of the airways causes an increase in the expression of inducible NO synthase type 2, with consequent increase in NO.”
Selected ion flow tube mass spectrometry of exhaled breath condensate headspace
Čáp, P., Dryahina, K., Pehal, F., & Španěl, P. (2008) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.3685 · Cited by 38
Aerobic Training Reduces Chronic Airway Inflammation and Mediators of Remodeling in Asthma
Moraes-Ferreira, R., Brandão-Rangel, M. A. R., Gibson-Alves, T. G., Silva-Reis, A., Souza-Palmeira, V. H., Aquino-Santos, H. C., Frison, C. R., de Oliveira, L. V. F., Albertini, R., & Vieira, R. P. (2022) · Oxidative Medicine and Cellular Longevity · doi:10.1155/2022/5037553 · Cited by 37
“The FeNO was measured using the monitor NoBreath (Bed-font Scienti fi c, UK) as a sensible biomarker of lung in fl am-mation, and the results were expressed in parts per billion (ppb) [18].”
Exercise changes volatiles in exhaled breath assessed by an electronic nose
Bikov, A., Lázár, Z., Schandl, K., Antus, B., Losonczy, G., & Horváth, I. (2011) · Acta Physiologica Hungarica · doi:10.1556/aphysiol.98.2011.3.9 · Cited by 37
Self-citationExhaled breath condensate MMP‐9 levels in children with bronchiectasis
Karakoç, G. B., İnal, A., Yilmaz, M., Altıntaş, D. U., & Kendirli, S. G. (2009) · Pediatric Pulmonology · doi:10.1002/ppul.21096 · Cited by 39
“One way of understanding such diseases is the exhaled breath condensate (EBC) which is a non-invasive method, and extremely helpful in certain limitations of BAL and induced sputum.(21) EBC contains every molecule that have been in airway lining fluid, even in very small concentrations.”
MethodUtility of exhaled nitric oxide as a noninvasive biomarker of lung inflammation in a disease model
Birrell, M. A., McCluskie, K., Hardaker, E. L., Knowles, R. G., & Belvisi, M. (2006) · European Respiratory Journal · doi:10.1183/09031936.00048506 · Cited by 38
Greguš, M., Foret, F., Kindlová, D., Pokojová, E., Plutinský, M., Doubková, M., Merta, Z., Binková, I., Skřičková, J., & Kubáň, P. (2015) · Journal of Breath Research · doi:10.1088/1752-7155/9/2/027107 · Cited by 37
RANTES in exhaled breath condensate of stable and unstable asthma patients
Ziętkowski, Z., Tomasiak, M. M., Skiepko, R., & Bodzenta‐Łukaszyk, A. (2008) · Respiratory Medicine · doi:10.1016/j.rmed.2008.03.010 · Cited by 37
Mehta, A., Cordero, J., Dobersch, S., Romero‐Olmedo, A. J., Savai, R., Bodner, J., Chao, C., Fink, L., Guzmán‐Díaz, E., Singh, I., et al. (2016) · EMBO Molecular Medicine · doi:10.15252/emmm.201606382 · Cited by 37
“Thus, EBC-based LC diagnosis requires appropriate stringent standardization protocols in order to reduce variability and increase sensitivity of the technique (Horvath et al, 2005).”
MethodInfluentialAusín, P., Martínez‐Llorens, J., Bresco, M. S., Casadevall, C., Barreiro, E., & Gea, J. (2016) · Chronic Respiratory Disease · doi:10.1177/1479972316674412 · Cited by 43
“Patients were asked to breath for 10 minutes in a condensator under ventilatory control (EcoScreen/ECoVent, Jaeger, Germany) according to the recommendations from ATS/ERS task force.(38) The samples were immediately frozen and later analyzed.”
MethodThevis, M., Krug, O., Geyer, H., & Schänzer, W. (2017) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.7903 · Cited by 38
“Based on the identification of these non‐volatile analytes (predominantly contained in the alveolar lining fluid and surfactant) in EB,(33,34) the formation of the breath aerosol was suggested to include bronchiolar and alveolar components.(35,36) Lung surfactant and surface lining fluid are separated from the blood s…”
BackgroundIncreased metal concentrations in exhaled breath condensate of industrial welders
Hoffmeyer, F., Weiß, T., Lehnert, M., Pesch, B., Berresheim, H., Henry, J., Raulf, M., Broding, H. C., Bünger, J., Harth, V., et al. (2010) · Journal of Environmental Monitoring · doi:10.1039/c0em00225a · Cited by 36
Hubbard, H. F., Sobus, J. R., Pleil, J. D., Madden, M. C., & Tabucchi, S. (2009) · Journal of Chromatography B · doi:10.1016/j.jchromb.2009.09.008 · Cited by 36
Airway inflammation in obstructive sleep apnea: Is leptin the missing link?
Antonopoulou, S., Loukides, S., Papatheodorou, G., Roussos, C., & Alchanatis, M. (2008) · Respiratory Medicine · doi:10.1016/j.rmed.2008.04.021 · Cited by 38
Drinking Influences Exhaled Breath Condensate Acidity
Kullmann, T., Barta, I., Antus, B., & Horváth, I. (2008) · Lung · doi:10.1007/s00408-008-9086-6 · Cited by 36
Self-citationCytokine concentrations in exhaled breath condensates in systemic sclerosis
Edmé, J., Tellart, A. S., Launay, D., Nevière, R., Grutzmacher, C., Boulenguez, C., Labalette, M., HACHULLA, E., Hatron, P., Dessaint, J., et al. (2008) · Inflammation Research · doi:10.1007/s00011-007-7136-9 · Cited by 36
“As many authors have already pointed out, biomarker determination in EBC can be evaluated non-invasive manner, the tests are easy to perform in a reproducible manner on both specifi c populations as well as controls , and do not require exercise or exertion on the part of the subjects [8].”
Exhaled breath condensate: a new method for lung disease diagnosis
Čepelak, I., & Dodig, S. (2007) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2007.326 · Cited by 41
Human breath metabolomics using an optimized non-invasive exhaled breath condensate sampler
Zamuruyev, K. O., Aksenov, A. A., Pasamontes, A., Brown, J. F., Pettit, D. R., Foutouhi, S., Weimer, B. C., Schivo, M., Kenyon, N. J., Delplanque, J., et al. (2016) · Journal of Breath Research · doi:10.1088/1752-7163/11/1/016001 · Cited by 38
“The choice of the method may affect the metabolomic content of the collected sample and may require optimization for particular type of biomarkers [17, 41, 42].”
BackgroundMethodInfluentialBreath biomarkers in idiopathic pulmonary fibrosis: a systematic review
Hayton, C., Terrington, D. L., Wilson, A. M., Chaudhuri, N., Leonard, C. T., & Fowler, S. J. (2019) · Respiratory Research · doi:10.1186/s12931-019-0971-8 · Cited by 38
“Following collection, relevant analytes can be measured using specific assays or mass spectrometry [39].”
BackgroundResultInfluentialKarakoç, G. B., Yükselen, A., Yilmaz, M., Altıntaş, D. U., & Kendirli, S. G. (2012) · Annals of Allergy Asthma & Immunology · doi:10.1016/j.anai.2012.02.019 · Cited by 39
Exhaled breath condensate—site and mechanisms of formation
Bondesson, E., Jansson, L., Bengtsson, T., & Wollmer, P. (2009) · Journal of Breath Research · doi:10.1088/1752-7155/3/1/016005 · Cited by 35
Exhaled breath condensates in asthma: diagnostic and therapeutic implications
Kazani, S. D., & Israel, E. (2010) · Journal of Breath Research · doi:10.1088/1752-7155/4/4/047001 · Cited by 35
Oxidative Stress Contributes to Bacterial Airborne Loss of Viability
Oswin, H. P., Haddrell, A. E., Hughes, C., Otero-Fernandez, M., Thomas, R. J., & Reid, J. P. (2023) · Microbiology Spectrum · doi:10.1128/spectrum.03347-22 · Cited by 37
Schumann, C., Triantafilou, K., Krueger, S., Hombach, V., Triantafilou, M., Becher, G., & Lepper, P. M. (2006) · Mediators of Inflammation · doi:10.1155/mi/2006/18061 · Cited by 36
“Even though the sampling of EBC was strictly performed according to the ATS/ERS Task Force Report on EBC, the inconstant detection of EPO, respectively, TNF-α might be explained by unresolved and previously reported methodological problems like unknown dilution of each biomarker in EBC [16].”
MethodInfluentialChérot‐Kornobis, N., Hulo, S., Edmé, J., de Broucker, V., Matran, R., & Sobaszek, A. (2011) · BMC Research Notes · doi:10.1186/1756-0500-4-202 · Cited by 35
“After collection, the condensates were immediately divided into aliquots and stored at -80°C [25].”
Lee, J. S., Shin, J. H., Hwang, J.-H., Baek, J. E., & Choi, B.-S. (2014) · Safety and Health at Work · doi:10.1016/j.shaw.2014.03.001 · Cited by 39
“Collection of EBC was performed in accordance with the guidelines of the American Thoracic Society [18].”
MethodNon-invasive monitoring of diabetes through analysis of the exhaled breath condensate (aerosol)
Karyakin, A. A., Никулина, С. В., Vokhmyanina, D. V., Karyakina, E. E., Anaev, E. K., & Чучалин, А. Г. (2017) · Electrochemistry Communications · doi:10.1016/j.elecom.2017.09.005 · Cited by 36
Exhaled breath analysis: from occupational to respiratory medicine.
Corradi, M., & Mutti, A. (2005) · PubMed · Cited by 35
Corradi, M., Gergelová, P., Pilato, E. D., Folesani, G., Goldoni, M., Andreoli, R., Selis, L., & Mutti, A. (2011) · International Archives of Occupational and Environmental Health · doi:10.1007/s00420-011-0686-8 · Cited by 38
Chemically polymerized polypyrrole for on-chip concentration of volatile breath metabolites
Strand, N. S., Bhushan, A., Schivo, M., Kenyon, N. J., & Davis, C. E. (2009) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2009.09.052 · Cited by 34
“One method is to collect filtered breath through the use of sampling bags [22,23]; another is to collect only the exhaled breath condensate (EBC) for sampling [24,25]; and a third method is to concentrate exhaled breath directly onto a substrate such as a carbon-activated sorbent [26,27] or solid-phase microextraction…”
MethodGórska, K., Maskey‐Warzęchowska, M., Nejman‐Gryz, P., Korczyński, P., Prochorec‐Sobieszek, M., & Krenke, R. (2016) · Polskie Archiwum Medycyny Wewnętrznej · doi:10.20452/pamw.3299 · Cited by 36
García‐Marcos, L., Edwards, J., Kennington, E. J., Aurora, P., Baraldi, E., Carraro, S., Gappa, M., Louis, R. E., Moreno, A., Peroni, D. G., et al. (2017) · Clinical & Experimental Allergy · doi:10.1111/cea.13080 · Cited by 37
“Markers in breath condensate Exhaled breath condensate (EBC) enables the study of the pathological processes undergoing in the lung.(28) As EBC is a non-invasive technique, it can be easily applied even in children too young to be”
BackgroundReal-time exhaled breath analysis in patients with cystic fibrosis and controls
Gaisl, T., Bregy, L., Stebler, N., Gaugg, M. T., Bruderer, T., García‐Gómez, D., Mœller, A., Singer, F., Schwarz, E. I., Benden, C., et al. (2018) · Journal of Breath Research · doi:10.1088/1752-7163/aab7fd · Cited by 38
“Although we adhered to recommendations suggesting one hour fasting [27], we have not systematically assessed possi-”
MethodMEMS-Based Ionization Gas Sensors for VOCs with Array of Nanostructured Silicon Needles
Wang, B., Dong, X., Wang, Z., Wang, Y., & Hou, Z. (2020) · ACS Sensors · doi:10.1021/acssensors.9b02458 · Cited by 34
Shoman, Y., Wild, P. P., Hemmendinger, M., Graille, M., Sauvain, J., Hopf, N. B., & Canu, I. G. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21113822 · Cited by 34
“Immunoassays are more accessible for laboratories because they do not require a special apparatus like mass spectrometry [107], but the latter is more sensitive and specific compared to immunoassays [5].”
InfluentialBiodiagnostics in an era of global pandemics—From biosensing materials to data management
Broza, Y. Y., & Haick, H. (2021) · View · doi:10.1002/viw.20200164 · Cited by 36
Zock, J., Rodríguez-Trigo, G., Rodríguez-Rodríguez, E., Souto-Alonso, A., Espinosa, A., Pozo-Rodríguez, F., Gómez, F. P., Fuster, C., Castaño‐Vinyals, G., Antó, J. M., et al. (2013) · Environment International · doi:10.1016/j.envint.2013.09.020 · Cited by 34
Bikov, A., Gajdócsi, R., Huszár, É., Szili, B., Lázár, Z., Antus, B., Losonczy, G., & Horváth, I. (2010) · Journal of Asthma · doi:10.1080/02770903.2010.512690 · Cited by 34
“This method can be repeated within short intervals without side or carryover effects of sampling, thus providing a unique method to follow changes in airway mediator levels (11).”
MethodSelf-citationLázár, Z., Huszár, É., Kullmann, T., Barta, I., Antus, B., Bikov, A., Kollai, M., & Horváth, I. (2008) · Inflammation Research · doi:10.1007/s00011-008-8009-6 · Cited by 34
“EBC contains no cells, and its low protein content implies low ATPase activity [16].”
BackgroundSelf-citationChapman, E. A., Thomas, P. S., & Yates, D. H. (2010) · Journal of Breath Research · doi:10.1088/1752-7155/4/3/034001 · Cited by 34
Metadata
- Authors
- Horváth, I., Hunt, J., & Barnes, P. J.
- Affiliations
- Országos Korányi Tbc és Pulmonológiai Intézet (HU)
- University of Virginia (US)
- Institute of Cancer Research (GB)
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2005-09
- Volume
- 26
- Issue
- 3
- Pages
- 523-548
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W1989935661
- Cited by
- 1,284
- References
- 280
- Citations by year
- 2026: 43 · 2025: 28 · 2024: 35 · 2023: 30 · 2022: 51 · 2021: 43 · 2020: 47 · 2019: 50 · 2018: 53 · 2017: 61 · 2016: 60 · 2015: 68 · 2014: 76 · 2013: 82 · 2012: 107
- FWCI
- 48.86
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- European Respiratory Journal (publishedVersion)
- PubMed (publishedVersion)
- Research Publications (Maastricht University) (publishedVersion, other-oa)
- Publikationsdatenbank der Fraunhofer-Gesellschaft (Fraunhofer-Gesellschaft) (submittedVersion)
- Fraunhofer-Publica (Fraunhofer-Gesellschaft) (submittedVersion)
- Radboud Repository (Radboud University) (submittedVersion)
- OpenAgrar (submittedVersion)
- Padua Research Archive (University of Padova) (submittedVersion)
- Research Publications (Maastricht University) (submittedVersion, other-oa)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Chemical Sensor Technologies
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Asthma and respiratory diseases
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Chronic Obstructive Pulmonary Disease (COPD) Research
- Keywords
- exhaled breath condensate, adenosine, hydrogen peroxide, isoprostanes, leukotrienes, nitrogen oxides, cytokines, reproducibility, longitudinal study, lung disease
- MeSH terms
- Breath Tests, Humans, Lung Diseases, Reproducibility of Results, Biomarkers, Oxidative Stress
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.