Impact of variance components on reliability of absolute quantification using digital PCR
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Digital polymerase chain reaction (dPCR) is an increasingly popular technology for detecting and quantifying target nucleic acids. Its advertised strength is high precision absolute quantification without needing reference curves. The standard data analytic approach follows a seemingly straightforward theoretical framework but ignores sources of variation in the data generating process. These stem from both technical and biological factors, where we distinguish features that are 1) hard-wired in the equipment, 2) user-dependent and 3) provided by manufacturers but may be adapted by the user. The impact of the corresponding variance components on the accuracy and precision of target concentration estimators presented in the literature is studied through simulation. RESULTS: We reveal how system-specific technical factors influence accuracy as well as precision of concentration estimates. We find that a well-chosen sample dilution level and modifiable settings such as the fluorescence cut-off for target copy detection have a substantial impact on reliability and can be adapted to the sample analysed in ways that matter. User-dependent technical variation, including pipette inaccuracy and specific sources of sample heterogeneity, leads to a steep increase in uncertainty of estimated concentrations. Users can discover this through replicate experiments and derived variance estimation. Finally, the detection performance can be improved by optimizing the fluorescence intensity cut point as suboptimal thresholds reduce the accuracy of concentration estimates considerably. CONCLUSIONS: Like any other technology, dPCR is subject to variation induced by natural perturbations, systematic settings as well as user-dependent protocols. Corresponding uncertainty may be controlled with an adapted experimental design. Our findings point to modifiable key sources of uncertainty that form an important starting point for the development of guidelines on dPCR design and data analysis with correct precision bounds. Besides clever choices of sample dilution levels, experiment-specific tuning of machine settings can greatly improve results. Well-chosen data-driven fluorescence intensity thresholds in particular result in major improvements in target presence detection. We call on manufacturers to provide sufficiently detailed output data that allows users to maximize the potential of the method in their setting and obtain high precision and accuracy for their experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures









Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This measurement uncertainty could be due to pipetting errors or variations in droplet or partition volume, which have a strong influence on platform sensitivity53,55,56.”
From Comparing the precision of two digital PCR applications for copy number comparisons in protists (2025) · cites this paper as [55]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The MIQE guidelines: minimum information for publication of quantitative real-time PCR experiments
Bustin, S. A., Benes, V., Garson, J. A., Hellemans, J., Huggett, J., Kubista, M., Mueller, R., Nolan, T., Pfaffl, M. W., Shipley, G. L., et al. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.112797 · Cited by 16,303
High-throughput droplet digital PCR system for absolute quantitation of DNA copy number
Hindson, B. J., Ness, K. D., Masquelier, D. A., Belgrader, P., Heredia, N. J., Makarewicz, A. J., Bright, I. J., Lucero, M. Y., Hiddessen, A. L., Legler, T. C., et al. (2011) · Analytical Chemistry · doi:10.1021/ac202028g · Cited by 2,792 · cited 5×
“This method is still used in the literature and stems from initial papers on digital PCR which deal with small numbers of partitions and pooled repeated experiments to obtain the required accuracy [12,16,21,26].”
BackgroundMethodInfluentialVogelstein, B., & Kinzler, K. W. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.16.9236 · Cited by 1,770 · cited 1×
“The proof of concept followed a few years later [3].”
BackgroundEvaluation of a Droplet Digital Polymerase Chain Reaction Format for DNA Copy Number Quantification
Pinheiro, L. B., Coleman, V. A., Hindson, C. M., Herrmann, J., Hindson, B. J., Bhat, S., & Emslie, K. R. (2012) · Analytical Chemistry · doi:10.1021/ac202578x · Cited by 1,055
Huggett, J. F., Foy, C. A., Benes, V., Emslie, K., Garson, J. A., Haynes, R., Hellemans, J., Kubista, M., Mueller, R. D., Nolan, T., et al. (2013) · Clinical Chemistry · doi:10.1373/clinchem.2013.206375 · Cited by 859 · cited 1×
“Similar efforts to raise awareness and formulate guidelines for digital PCR have been very recently published [18].”
BackgroundWhale, A. S., Huggett, J. F., Cowen, S., Speirs, V., Shaw, J., Ellison, S., Foy, C. A., & Scott, D. J. (2012) · Nucleic Acids Research · doi:10.1093/nar/gks203 · Cited by 453 · cited 6×
“Dube, S., Qin, J., Ramakrishnan, R.: Mathematical analysis of copy number variation in a DNA sample using digital PCR on a nanofluidic device.”
BackgroundMethodInfluentialEvaluation of digital PCR for absolute DNA quantification
Sanders, R., Huggett, J. F., Bushell, C. A., Cowen, S., Scott, D. J., & Foy, C. A. (2011) · Analytical Chemistry · doi:10.1021/ac103230c · Cited by 338 · cited 1×
“The most popular applications so far are low copy number detection [14,15] and copy number variation [16,17].”
BackgroundDube, S., Qin, J., & Ramakrishnan, R. (2008) · PLoS ONE · doi:10.1371/journal.pone.0002876 · Cited by 302
Weaver, S., Dube, S., Mir, A., Qin, J., Sun, G., Ramakrishnan, R., Jones, R. C., & Livak, K. J. (2010) · Methods · doi:10.1016/j.ymeth.2010.01.003 · Cited by 220
Bhat, S., Herrmann, J., Armishaw, P., Corbisier, P., & Emslie, K. R. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-2729-5 · Cited by 218 · cited 4×
“In practice, droplets vary in size while chambers do not contain the exact same volume [19,20].”
BackgroundInfluentialStudying copy number variations using a nanofluidic platform
Qin, J., Jones, R. C., & Ramakrishnan, R. (2008) · Nucleic Acids Research · doi:10.1093/nar/gkn518 · Cited by 102 · cited 1×
“The most popular applications so far are low copy number detection [14,15] and copy number variation [16,17].”
Background
Research works printed but not linked: 15
- Sykes PJ Neoh SH Brisco MJ Hughes E Condon J Morley AA Quantitation of targets for PCR by use of limiting dilution Biotechniques 1992 13 3 444 449 1389177
- Baker M Digital PCR hits its stride Nat Methods 2012 9 6 541 544 10.1038/nmeth.2027 · DOI · Paper page
- Day E Dear PH McCaughan F Digital PCR strategies in the development and analysis of molecular biomarkers for personalized medicine Methods 2013 59 1 101 107 10.1016/j.ymeth.2012.08.001 22926236 · DOI · Paper page
- Burns M Burrell A Foy C The applicability of digital PCR for the assessment of detection limits in GMO analysis Eur Food Res Technol 2010 231 3 353 362 10.1007/s00217-010-1277-8 · DOI
- Heredia NJ Belgrader P Wang S Koehler R Regan J Cosman AM Saxonov S Hindson B Tanner SC Brown AS Karlin-Neumann G Droplet digital™ PCR quantitation of HER2 expression in FFPE breast tissue samples Methods 2013 59 1 S20—S23 10.1016/j.ymeth.2012.09.012 23036330 · DOI
- Nadauld L Regan JF Miotke L Pai RK Longacre TA Kwok SS Saxonov S Ford JM Ji HP Quantitative and sensitive detection of cancer genome amplifications from formalin fixed paraffin embedded tumors with droplet digital PCR Transl Med (Sunnyvale, Calif.) 2012 2 2 107 PMC3653435 23682346
- Hayden R Gu Z Ingersoll J Abdul-Ali D Shi L Pounds S Caliendo A Comparison of droplet digital PCR to real-time PCR for quantitative detection of cytomegalovirus J Clin Microbiol 2013 51 2 540 546 10.1128/JCM.02620-12 23224089 PMC3553899 · DOI · Paper page
- Henrich TJ Gallien S Li JZ Pereyra F Kuritzkes DR Low-level detection and quantitation of cellular HIV-1 DNA and 2-LTR circles using droplet digital PCR J Virol Methods 2012 186 1–2 68 72 10.1016/j.jviromet.2012.08.019 22974526 PMC3517891 · DOI · Paper page
- Sedlak RH Jerome KR Viral diagnostics in the era of digital polymerase chain reaction Diagn Microbiol Infect Dis 2013 75 1 1 4 10.1016/j.diagmicrobio.2012.10.009 23182074 PMC3519953 · DOI
- White RA Blainey PC Fan HC Quake SR Digital PCR provides sensitive and absolute calibration for high throughput sequencing BMC Genomics 2009 10 1 116 10.1186/1471-2164-10-116 19298667 PMC2667538 · DOI · Paper page
- Pekin D Skhiri Y Baret J-C Le Corre D Mazutis L Salem CB Millot F El Harrak A Hutchison JB Larson JW Link DR Laurent-Puig P Griffiths AD Taly V Quantitative and sensitive detection of rare mutations using droplet-based microfluidics Lab Chip 2011 11 13 2156 2166 10.1039/c1lc20128j 21594292 · DOI · Paper page
- Lievens A Van Aelst S Van den Bulcke M Goetghebeur E Simulation of between repeat variability in real time PCR reactions PLoS One 2012 7 11 47112 10.1371/journal.pone.0047112 PMC3506646 23189123 · DOI
- Kiss MM Ortoleva-Donnelly L Beer NR Warner J Bailey CG Colston BW Rothberg JM Link DR Leamon JH High-throughput quantitative polymerase chain reaction in picoliter droplets Anal Chem 2008 80 23 8975 8981 10.1021/ac801276c 19551929 PMC2771884 · DOI · Paper page
- De St Groth S The evaluation of limiting dilution assays J Immunol Methods 1982 49 2 11 23 10.1016/0022-1759(82)90269-1 7040548 · DOI · Paper page
- Gregory J Turbidity fluctuations in flowing suspensions J Colloid Interface Sci 1985 105 2 357 371 10.1016/0021-9797(85)90309-1 · doi:10.1016/0021-9797(85)90309-1
Cited by
The dMIQE Group, Whale, A. S., De Spiegelaere, W., Trypsteen, W., Nour, A. A., Bae, Y.-K., Benes, V., Burke, D., Cleveland, M., Corbisier, P., et al. (2020) · Clinical Chemistry · doi:10.1093/clinchem/hvaa125 · Cited by 516
Liang, N., Li, B., Jia, Z., Wang, C., Wu, P., Zheng, T., Wang, Y., Qiu, F., Wu, Y., Su, J., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00746-5 · Cited by 209
Comparing the precision of two digital PCR applications for copy number comparisons in protists
Gross, M., Stoeck, T., Mauvisseau, Q., Schrøder-Nielsen, A., & Dunthorn, M. (2025) · Scientific Reports · doi:10.1038/s41598-025-13143-8 · Cited by 6
Metadata
- Authors
- Jacobs, B. K., Goetghebeur, E., & Clement, L.
- Venue
- BMC Bioinformatics
- Published
- 2014-08-22
- Volume
- 15
- Issue
- 1
- ISSN
- 1471-2105
- PMC
- PMC4261249
- Cited by
- 57
- References
- 11
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.