Critical assessment of alignment procedures for LC-MS proteomics and metabolomics measurements
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Liquid chromatography coupled to mass spectrometry (LC-MS) has become a prominent tool for the analysis of complex proteomics and metabolomics samples. In many applications multiple LC-MS measurements need to be compared, e. g. to improve reliability or to combine results from different samples in a statistical comparative analysis. As in all physical experiments, LC-MS data are affected by uncertainties, and variability of retention time is encountered in all data sets. It is therefore necessary to estimate and correct the underlying distortions of the retention time axis to search for corresponding compounds in different samples. To this end, a variety of so-called LC-MS map alignment algorithms have been developed during the last four years. Most of these approaches are well documented, but they are usually evaluated on very specific samples only. So far, no publication has been assessing different alignment algorithms using a standard LC-MS sample along with commonly used quality criteria. RESULTS: We propose two LC-MS proteomics as well as two LC-MS metabolomics data sets that represent typical alignment scenarios. Furthermore, we introduce a new quality measure for the evaluation of LC-MS alignment algorithms. Using the four data sets to compare six freely available alignment algorithms proposed for the alignment of metabolomics and proteomics LC-MS measurements, we found significant differences with respect to alignment quality, running time, and usability in general. CONCLUSION: The multitude of available alignment methods necessitates the generation of standard data sets and quality measures that allow users as well as developers to benchmark and compare their map alignment tools on a fair basis. Our study represents a first step in this direction. Currently, the installation and evaluation of the "correct" parameter settings can be quite a time-consuming task, and the success of a particular method is still highly dependent on the experience of the user. Therefore, we propose to continue and extend this type of study to a community-wide competition. All data as well as our evaluation scripts are available at http://msbi.ipb-halle.de/msbi/caap.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bioconductor: open software development for computational biology and bioinformatics
Gentleman, R. C., Carey, V. J., Bates, D. M., Bolstad, B., Dettling, M., Dudoit, S., Ellis, B., Gautier, L., Ge, Y., Gentry, J., et al. (2004) · Genome Biology · doi:10.1186/gb-2004-5-10-r80 · Cited by 12,172 · cited 4×
“5 XCMS The XCMS package presented in [26] is part of Bioconductor [37], a larger open source software project for bioinformatics written in the platform-independent programming language R.”
MethodInfluentialDynamic Programming Algorithm Optimization for Spoken Word Recognition
Sakoe, H., & Chiba, S. (1978) · IEEE Transactions on Acoustics Speech and Signal Processing · doi:10.1109/tassp.1978.1163055 · Cited by 6,727 · cited 1×
“The correction of the shift in RT and m/z is called dewarping according to the time warping problem of Sakoe and Chiba [12] in speech processing.”
MethodSmith, C. A., Want, E. J., O'Maille, G., Abagyan, R., & Siuzdak, G. (2006) · Analytical Chemistry · doi:10.1021/ac051437y · Cited by 5,262 · cited 4×
“The feature finding was done using XCMS [26] using the parameters method = "centWave", peakwidth = c(20, 50), snthresh = 5, ppm = 120 for the data set M1 and ppm = 30 for the data set M2, respectively.”
MethodInfluentialPARAFAC. Tutorial and applications
Bro, R. (1997) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(97)00032-4 · Cited by 2,814
Mass spectrometry–based proteomics turns quantitative
Ong, S.-E., & Mann, M. (2005) · Nature Chemical Biology · doi:10.1038/nchembio736 · Cited by 1,572 · cited 1×
“The quantitative information in a proteomics LC-MS map can be used in numerous applications [3,4] ranging from additive series in analytical chemistry [5], analysis of time series in expression experiments [6,7], to applications in clinical diagnostics [8], where statistically significant markers detect certain states…”
BackgroundMZmine: toolbox for processing and visualization of mass spectrometry based molecular profile data
Katajamaa, M., Miettinen, J., & Orešič, M. (2006) · Bioinformatics · doi:10.1093/bioinformatics/btk039 · Cited by 831 · cited 1×
“6 MZmine The MZmine toolbox [38] for processing and visualization of LC/MS data is used via a graphical user interface.”
MethodOpenMS – An open-source software framework for mass spectrometry
Sturm, M., Bertsch, A., Gröpl, C., Hildebrandt, A., Hussong, R., Lange, E., Pfeifer, N., Schulz-Trieglaff, O., Zerck, A., Reinert, K., et al. (2008) · BMC Bioinformatics · doi:10.1186/1471-2105-9-163 · Cited by 644
Self-citationMass spectrometric-based approaches in quantitative proteomics
Ong, S. (2003) · Methods · doi:10.1016/s1046-2023(02)00303-1 · Cited by 451 · cited 1×
“The quantitative information in a proteomics LC-MS map can be used in numerous applications [3,4] ranging from additive series in analytical chemistry [5], analysis of time series in expression experiments [6,7], to applications in clinical diagnostics [8], where statistically significant markers detect certain states…”
BackgroundProcessing methods for differential analysis of LC/MS profile data
Katajamaa, M., & Orešič, M. (2005) · BMC Bioinformatics · doi:10.1186/1471-2105-6-179 · Cited by 400 · cited 14×
“RT performed parameter tuning and test runs for MZmine, XAlign and XCMS.”
MethodInfluentialCatchpole, G. S., Beckmann, M., Enot, D. P., Mondhe, M., Zywicki, B., Taylor, J., Hardy, N., Smith, A., King, R. D., Kell, D. B., et al. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0503955102 · Cited by 392 · cited 1×
“Common applications in metabolomics are: The verification of substantial equivalence [9], or the profiling of, e.”
Background
Cited by
Pluskal, T., Castillo, S., Villar-Briones, A., & Orešič, M. (2010) · BMC Bioinformatics · doi:10.1186/1471-2105-11-395 · Cited by 3,845
Multivariate Analysis in Metabolomics
Worley, B., & Powers, R. (2012) · Current Metabolomics · doi:10.2174/2213235x11301010092 · Cited by 1,348
Lommen, A. (2009) · Analytical Chemistry · doi:10.1021/ac900036d · Cited by 734
Zhou, B., Xiao, J. F., Tuli, L., & Ressom, H. W. (2011) · Molecular BioSystems · doi:10.1039/c1mb05350g · Cited by 639
Uppal, K., Soltow, Q. A., Strobel, F. H., Pittard, W. S., Gernert, K. M., Yu, T., & Jones, D. P. (2013) · BMC Bioinformatics · doi:10.1186/1471-2105-14-15 · Cited by 372
Quality assurance procedures for mass spectrometry untargeted metabolomics. a review
Dudzik, D., Barbas-Bernardos, C., García, A., & Barbas, C. (2018) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2017.07.044 · Cited by 344
bioinformatics tools for mass spectroscopy-based metabolomic data processing and analysis
Sugimoto, M., Kawakami, M., Robert, M., Soga, T., & Tomita, M. (2012) · Current Bioinformatics · doi:10.2174/157489312799304431 · Cited by 307
“Evaluation of the alignment of LC-MS data using six freely available software packages, including XCMS [53], MZmine [56], msInspect [103] and OpenMS [55], concluded that no single software perfectly aligned the datasets [104].”
MethodComputational Metabolomics: A Framework for the Million Metabolome
Uppal, K., Walker, D. I., Liu, K., Li, S., Go, Y.-M., & Jones, D. P. (2016) · Chemical Research in Toxicology · doi:10.1021/acs.chemrestox.6b00179 · Cited by 244
“43,47 Pairwise alignment is then completed by reference to the profile with maximum number of detected features, and all other profiles are aligned with respect to the reference in a pairwise fashion using methods such as dynamic time warping, ObiWarp, and kernel smoothing.”
Analytical and statistical approaches to metabolomics research
Issaq, H. J., Van, Q. N., Waybright, T. J., Muschik, G. M., & Veenstra, T. D. (2009) · Journal of Separation Science · doi:10.1002/jssc.200900152 · Cited by 227
Tools for Label-free Peptide Quantification
Nahnsen, S., Bielow, C., Reinert, K., & Kohlbacher, O. (2013) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r112.025163 · Cited by 225
“47.”
Navigating freely-available software tools for metabolomics analysis
Spicer, R., Salek, R. M., Moreno, P., Cañueto, D., & Steinbeck, C. (2017) · Metabolomics · doi:10.1007/s11306-017-1242-7 · Cited by 215
Helmus, R., ter Laak, T. L., van Wezel, A. P., de Voogt, P., & Schymanski, E. L. (2021) · Journal of Cheminformatics · doi:10.1186/s13321-020-00477-w · Cited by 208
Analytical Approaches to Metabolomics and Applications to Systems Biology
Wang, J. H., Byun, J., & Pennathur, S. (2010) · Seminars in Nephrology · doi:10.1016/j.semnephrol.2010.07.007 · Cited by 194
Brunius, C., Shi, L., & Landberg, R. (2016) · Metabolomics · doi:10.1007/s11306-016-1124-4 · Cited by 182
“Such drifts could therefore severely affect subsequent statistical analysis and further metabolite identification (America et al. 2006; Nordström et al. 2006; Lange et al. 2008; Zhang et al. 2015).”
BackgroundComputational mass spectrometry for metabolomics: Identification of metabolites and small molecules
Neumann, S., & Böcker, S. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-4142-5 · Cited by 175
“, [2–4].”
Self-citationDraper, J., Enot, D. P., Parker, D., Beckmann, M., Snowdon, S., Lin, W., & Zubair, H. (2009) · BMC Bioinformatics · doi:10.1186/1471-2105-10-227 · Cited by 169
“Peak detection and particularly spectral deconvolution in GC-MS and LC-MS are both technically challenging, timeconsuming and very difficult to automate; LC-MS particularly has been hampered by poor analyte peak resolution and retention time variability which confound metabolite peak alignment [5,6].”
BackgroundGürdeniz, G., Kristensen, M., Skov, T., & Dragsted, L. O. (2012) · Metabolites · doi:10.3390/metabo2010077 · Cited by 61
“There are some studies attempting to define quality parameters for comparison of peak detection [11,12] or alignment [13] algorithms of different data preprocessing tools, but a direct comparison of the overall performance of the most commonly used data preprocessing tools has not so far been attempted.”
Background
Metadata
- Authors
- Lange, E., Tautenhahn, R., Neumann, S., & Gröpl, C.
- Venue
- BMC Bioinformatics
- Published
- 2008-09-15
- Volume
- 9
- Issue
- 1
- Pages
- 375-375
- ISSN
- 1471-2105 (ISSN-L)
- OpenAlex
- W2106017862
- Cited by
- 187
- References
- 36
- FWCI
- 5.71
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.