Focused ultrasound-mediated suppression of chemically-induced acute epileptic EEG activity
Open accessThe DOI matches its Crossref record; 66 of the 66 references it cites were found in a registry or an index.
Abstract
Background: Epilepsy is a common neurological disorder, which is attributed to uncontrollable abnormal hyper-excitability of neurons. We investigated the feasibility of using low-intensity, pulsed radiation of focused ultrasound (FUS) to non-invasively suppress epileptic activity in an animal model (rat), which was induced by the intraperitonial injection of pentylenetetrazol (PTZ). Results: After the onset of induced seizures, FUS was transcranially administered to the brain twice for three minutes each while undergoing electroencephalographic (EEG) monitoring. An air-backed, spherical segment ultrasound transducer (diameter: 6 cm; radius-of-curvature: 7 cm) operating at a fundamental frequency of 690 KHz was used to deliver a train of 0.5 msec-long pulses of sonication at a repetitive rate of 100 Hz to the thalamic areas of the brain. The acoustic intensity (130 mW/cm 2) used in the experiment was sufficiently within the range of safety guidelines for the clinical ultrasound imaging. The occurrence of epileptic EEG bursts from epilepsy-induced rats significantly decreased after sonication when it was compared to the pre-sonication epileptic state. The PTZ-induced control group that did not receive any sonication showed a sustained number of epileptic EEG signal bursts. The animals that underwent sonication also showed less severe epileptic behavior, as assessed by the Racine score. Histological analysis confirmed that the sonication did not cause any damage to the brain tissue. Conclusions: These results revealed that low-intensity, pulsed FUS sonication suppressed the number of epileptic signal bursts using acute epilepsy model in animal. Due to its non-invasiveness and spatial selectivity, FUS may offer new perspectives for a possible non-invasive treatment of epilepsy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Rat Brain in Stereotaxic Coordinates
(1982) · Elsevier eBooks · doi:10.1016/c2009-0-63235-9 · Cited by 51,963
The rat brain in stereotaxic coordinates
Palkovits, M. (1983) · Neuropeptides · doi:10.1016/0143-4179(83)90049-5 · Cited by 28,831
Modification of seizure activity by electrical stimulation: II. Motor seizure
Racine, R. J. (1972) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(72)90177-0 · Cited by 7,171
AChE-stained horizontal sections of the rat brain in stereotaxic coordinates
Paxinos, G., Watson, C. R. R., & Emson, P. C. (1980) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(80)90021-7 · Cited by 4,497
Fisher, R. S., Boas, W. V. E., Blume, W., Elger, C., Genton, P., Lee, P., & Engel, J. (2005) · Epilepsia · doi:10.1111/j.0013-9580.2005.66104.x · Cited by 3,671
Yuan, J. (1993) · Cell · doi:10.1016/0092-8674(93)90485-9 · Cited by 2,483
Supersonic shear imaging: a new technique for soft tissue elasticity mapping
Bercoff, J., Tanter, M., & Fink, M. (2004) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1295425 · Cited by 2,476
Epilepsy: A Comprehensive Textbook
(2008) · JAMA · doi:10.1001/jama.300.4.443-a · Cited by 2,341
Beghi, E., Berg, A., Carpio, A., Forsgren, L., Hesdorffer, D. C., Hauser, W. A., Malmgren, K., Shinnar, S., Temkin, N., Thurman, D., et al. (2005) · Epilepsia · doi:10.1111/j.1528-1167.2005.00273_1.x · Cited by 2,296
Transcranial magnetic stimulation in neurology
Kobayashi, M., & Pascual-Leone, A. (2003) · The Lancet Neurology · doi:10.1016/s1474-4422(03)00321-1 · Cited by 1,297
Cited by
Transcranial focused ultrasound modulates the activity of primary somatosensory cortex in humans
Legon, W., Sato, T. F., Opitz, A., Mueller, J., Barbour, A., Williams, A., & Tyler, W. J. (2014) · Nature Neuroscience · doi:10.1038/nn.3620 · Cited by 981
Ultrasound Neuromodulation: A Review of Results, Mechanisms and Safety
Blackmore, J., Shrivastava, S., Sallet, J., Butler, C. R., & Cleveland, R. O. (2019) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2018.12.015 · Cited by 556
Ultrasonic neuromodulation by brain stimulation with transcranial ultrasound
Tufail, Y., Yoshihiro, A., Pati, S., Li, M. M., & Tyler, W. J. (2011) · Nature Protocols · doi:10.1038/nprot.2011.371 · Cited by 473
Image-Guided Transcranial Focused Ultrasound Stimulates Human Primary Somatosensory Cortex
Lee, W., Kim, H., Jung, Y., Song, I.-U., Chung, Y. A., & Yoo, S.-S. (2015) · Scientific Reports · doi:10.1038/srep08743 · Cited by 414
Self-citationA review of low-intensity focused ultrasound pulsation
Bystritsky, A., Korb, A. S., Douglas, P. K., Cohen, M. S., Melega, W. P., Mulgaonkar, A. P., DeSalles, A., Min, B.-K., & Yoo, S.-S. (2011) · Brain Stimulation · doi:10.1016/j.brs.2011.03.007 · Cited by 409
Self-citationUltrasound modulates ion channel currents
Kubanek, J., Shi, J., Marsh, J., Chen, D., Deng, C., & Cui, J. (2016) · Scientific Reports · doi:10.1038/srep24170 · Cited by 353
Neuromodulation with single‐element transcranial focused ultrasound in human thalamus
Legon, W., Ai, L., Bansal, P., & Mueller, J. K. (2018) · Human Brain Mapping · doi:10.1002/hbm.23981 · Cited by 334
Non-invasive transcranial ultrasound stimulation for neuromodulation
Darmani, G., Bergmann, T. O., Butts Pauly, K., Caskey, C. F., de Lecea, L., Fomenko, A., Fouragnan, E., Legon, W., Murphy, K. R., Nandi, T., et al. (2022) · Clinical Neurophysiology · doi:10.1016/j.clinph.2021.12.010 · Cited by 332
Self-citationLow-intensity ultrasound neuromodulation: An overview of mechanisms and emerging human applications
Fomenko, A., Neudorfer, C., Dallapiazza, R. F., Kalia, S. K., & Lozano, A. M. (2018) · Brain Stimulation · doi:10.1016/j.brs.2018.08.013 · Cited by 322
Focused Ultrasound-mediated Non-invasive Brain Stimulation: Examination of Sonication Parameters
Kim, H., Chiu, A., Lee, S. D., Fischer, K., & Yoo, S.-S. (2014) · Brain Stimulation · doi:10.1016/j.brs.2014.06.011 · Cited by 304
Self-citationKrishna, V., Sammartino, F., & Rezai, A. (2018) · JAMA Neurology · doi:10.1001/jamaneurol.2017.3129 · Cited by 289
Ultrasound treatment of neurological diseases — current and emerging applications
Leinenga, G., Langton, C., Nisbet, R., & Götz, J. (2016) · Nature Reviews Neurology · doi:10.1038/nrneurol.2016.13 · Cited by 275
Plaksin, M., Kimmel, E., & Shoham, S. (2016) · eneuro · doi:10.1523/eneuro.0136-15.2016 · Cited by 268
Ultrasound Technologies for Imaging and Modulating Neural Activity
Rabut, C., Yoo, S., Hurt, R. C., Jin, Z., Li, H., Guo, H., Ling, B., & Shapiro, M. G. (2020) · Neuron · doi:10.1016/j.neuron.2020.09.003 · Cited by 249
Self-citationNaor, O., Krupa, S., & Shoham, S. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/031003 · Cited by 228
“US target (Researcher) Modulation effect Frequency (MHz) Isppa (W cm −2) TUS_Stim (s) PRF (Hz) Duty cycle % Cat: LGN (Fry et al 1958) Partial VEP suppression 0.98 1.35 20–120 100 Cat: edinger/wesrpal nucleus (Ballantine et al 1960) Functional response of eye pupil 2.7 1700a 0.14 0.33 4.6 Cat: spinal cord Reflex enhanc…”
BackgroundInfluentialFrequency Dependence of Ultrasound Neurostimulation in the Mouse Brain
Ye, P. P., Brown, J. R., & Pauly, K. B. (2016) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2016.02.012 · Cited by 226
Image-Guided Focused Ultrasound-Mediated Regional Brain Stimulation in Sheep
Lee, W., Lee, S. D., Park, M. Y., Foley, L., Purcell-Estabrook, E., Kim, H., Fischer, K., Maeng, L.-S., & Yoo, S.-S. (2016) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2015.10.001 · Cited by 218
Self-citationFocused ultrasound for neuromodulation
Darrow, D. P. (2019) · Neurotherapeutics · doi:10.1007/s13311-018-00691-3 · Cited by 190
“While a few early studies have reported meaningful progress towards the use of ultrasound for disease models of pain and epilepsy, the application of ultrasonic neuromodulation to treat other diseases of the nervous system, including movement disorders, psychiatric disorders, and even disorders indirectly regulated by…”
BackgroundPasquinelli, C., Hanson, L. G., Siebner, H. R., Lee, H. J., & Thielscher, A. (2019) · Brain Stimulation · doi:10.1016/j.brs.2019.07.024 · Cited by 190
“This might open up intriguing new applications such as epilepsy treatment or presurgical diagnostics prior to electrode implantation for deepbrain stimulation [2,3].”
BackgroundResultInfluentialAiran, R. D., Meyer, R. A., Ellens, N. P. K., Rhodes, K. R., Farahani, K., Pomper, M. G., Kadam, S. D., & Green, J. J. (2017) · Nano Letters · doi:10.1021/acs.nanolett.6b03517 · Cited by 183
Activation of Piezo1 but Not NaV1.2 Channels by Ultrasound at 43 MHz
Prieto, M. L., Firouzi, K., Khuri-Yakub, B. T., & Maduke, M. (2018) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2017.12.020 · Cited by 178
High-intensity focused ultrasound: past, present, and future in neurosurgery
Quadri, S. A., Waqas, M., Khan, I., Khan, M. A., Suriya, S. S., Farooqui, M., & Fiani, B. (2018) · Neurosurgical Focus · doi:10.3171/2017.11.focus17610 · Cited by 159
“63 Although further studies are warranted, neuromodulation with MRgFUS might provide clinicians with a future potential to nonin-vasively target a seizure focus in the brain before its permanent ablation, if needed.”
BackgroundScarcelli, T., Jordão, J. F., O'Reilly, M. A., Ellens, N., Hynynen, K., & Aubert, I. (2014) · Brain Stimulation · doi:10.1016/j.brs.2013.12.012 · Cited by 156
Focused Ultrasound for Essential Tremor: Review of the Evidence and Discussion of Current Hurdles
Rohani, M., & Fasano, A. (2017) · Tremor and Other Hyperkinetic Movements · doi:10.5334/tohm.378 · Cited by 73
The Emergence of Functional Ultrasound for Noninvasive Brain–Computer Interface
Zheng, H., Niu, L., Qiu, W., Liang, D., Long, X., Li, G., Liu, Z., & Meng, L. (2023) · Research · doi:10.34133/research.0200 · Cited by 27
Metadata
- Authors
- Min, B.-K., Bystritsky, A., Jung, K.-I., Fischer, K., Zhang, Y., Maeng, L.-S., In Park, S., Chung, Y.-A., Jolesz, F. A., & Yoo, S.-S.
- Venue
- BMC Neuroscience
- Published
- 2011-03-06
- Volume
- 12
- Issue
- 1
- Pages
- 23-23
- ISSN
- 1471-2202 (ISSN-L)
- OpenAlex
- W2120900139
- Cited by
- 274
- References
- 66
- FWCI
- 6.75
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.