CoChat

Early detection of breast cancer: benefits and risks of supplemental breast ultrasound in asymptomatic women with mammographically dense breast tissue. A systematic review

Open access
Nothacker, Monika, Duda, Volker, Hahn, Markus, Warm, Mathias, Degenhardt, Friedrich, Madjar, Helmut, Weinbrenner, Susanne, Albert, Ute-Susann · 2009 · BMC Cancer
Cited by 314

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Abstract

Background: Mammographic screening alone will miss a certain fraction of malignancies, as evidenced by retrospective reviews of mammograms following a subsequent screening. Mammographic breast density is a marker for increased breast cancer risk and is associated with a higher risk of interval breast cancer, i.e. cancer detected between screening tests. The purpose of this review is to estimate risks and benefits of supplemental breast ultrasound in women with negative mammographic screening with dense breast tissue. Methods: A systematic search and review of studies involving mammography and breast ultrasound for screening of breast cancer was conducted. The search was performed for the period 1/2000-8/2008 within the data source of PubMed, DARE, and Cochrane databases. Inclusion and exclusion criteria were determined prospectively, and the Oxford evidence classification system for diagnostic studies was used for evidence level. The parameters biopsy rate, positive predictive value (PPV) for biopsy, cancer yield for breast ultrasound alone, and carcinoma detection rate by breast density were extracted or constructed. Results: The systematic search identified no randomized controlled trials or systematic reviews, six cohort studies of intermediate level of evidence (3b) were found. Only two of the studies included adequate follow-up of subjects with negative or benign findings. Supplemental breast ultrasound after negative mammographic screening permitted diagnosis of primarily invasive carcinomas in 0.32% of women in breast density type categories 2-4 of the American College of Radiology (ACR); mean tumor size for those identified was 9.9 mm, 90% with negative lymph node status. Most detected cancers occurred in mammographically dense breast ACR types 3 and 4. Biopsy rates were in the range 2.3%-4.7%, with PPV of 8.4-13.7% for those biopsied due to positive ultrasound, or about one third of the PPV of biopsies due to mammography. Limitations: The study populations included wide age ranges, and the application to women age 50-69 years as proposed for mammographic screening could result in less striking benefit. Further validation studies should employ a uniform assessment system such as BI-RADS and report not only PPV, but also negative predictive value, sensitivity and specificity. Conclusion: Supplemental breast ultrasound in the population of women with mammographically dense breast tissue (ACR 3 and 4) permits detection of small, otherwise occult, breast cancers. Potential adverse impacts for women in this intermediate risk group are associated with an increased biopsy rate.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/1471-2407-9-335

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 314

Metadata

Authors
Nothacker, M., Duda, V., Hahn, M., Warm, M., Degenhardt, F., Madjar, H., Weinbrenner, S., & Albert, U.-S.
Venue
BMC Cancer
Published
2009-09-20
Volume
9
Issue
1
Pages
335-335
ISSN
1471-2407 (ISSN-L)
OpenAlex
W2017439667
Cited by
314
References
34
FWCI
2.43
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.