Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index; 13 of the 38 sources its claims cite were checked for support.

Low-intensity blue-enriched white light (750 lux) and standard bright light (10 000 lux) are equally effective in treating SAD. A randomized controlled study

Open access

Abstract

BACKGROUND: Photoreceptor cells containing melanopsin play a role in the phase-shifting effects of short-wavelength light. In a previous study, we compared the standard light treatment (SLT) of SAD with treatment using short-wavelength blue-enriched white light (BLT). Both treatments used the same illuminance (10,000 lux) and were equally highly effective. It is still possible, however, that neither the newly-discovered photoreceptor cells, nor the biological clock play a major role in the therapeutic effects of light on SAD. Alternatively, these effects may at least be partly mediated by these receptor cells, which may have become saturated as a result of the high illuminances used in the therapy. This randomized controlled study compares the effects of low-intensity BLT to those of high-intensity SLT. METHOD: In a 22-day design, 22 patients suffering from a major depression with a seasonal pattern (SAD) were given light treatment (10,000 lux) for two weeks on workdays. Subjects were randomly assigned to either of the two conditions, with gender and age evenly distributed over the groups. Light treatment either consisted of 30 minutes SLT (5000 °K) with the EnergyLight® (Philips, Consumer Lifestyle) with a vertical illuminance of 10,000 lux at eye position or BLT (17,000 °K) with a vertical illuminance of 750 lux using a prototype of the EnergyLight® which emitted a higher proportion of short-wavelengths. All participants completed questionnaires concerning mood, activation and sleep quality on a daily basis. Mood and energy levels were also assessed on a weekly basis by means of the SIGH-SAD and other assessment tools. RESULTS: On day 22, SIGH-SAD ratings were significantly lower than on day 1 (SLT 65.2% and BLT 76.4%). On the basis of all assessments no statistically significant differences were found between the two conditions. CONCLUSION: With sample size being small, conclusions can only be preliminary. Both treatment conditions were found to be highly effective. The therapeutic effects of low-intensity blue-enriched light were comparable to those of the standard light treatment. Saturation effects may play a role, even with a light intensity of 750 lux. The therapeutic effects of blue-enriched white light in the treatment of SAD at illuminances as low as 750 lux help bring light treatment for SAD within reach of standard workplace and educational lighting systems.

Overview

CoChat Summary

TL;DR

In 22 patients with seasonal affective disorder, two weeks of low-intensity blue-enriched white light (750 lux, 17,000°K) and standard bright light (10,000 lux, 5,000°K) both substantially reduced depressive symptoms, with no statistically significant differences between conditions. The authors conclude the treatments were equally effective but preliminary because of the small sample.

Key findings

  • On day 22, SIGH-SAD ratings were significantly lower than on day 1 in both groups: SLT 65.2% response and BLT 76.4% response, with effect sizes d = 2.54 and 3.53, respectively.
  • No statistically significant between-condition differences were found across weekly assessments: for SIGH-SAD, main effect “time” F(3,18) = 30.2, p < 0.001; main effect “condition” F(1,20) = 0.012, ns; interaction “time*condition” F(3,60) = 0.95, ns. Similar patterns were reported for HRSD, ATYP, BDI-II, and SFQ.
  • Daily self-ratings also showed significant time effects in all models but no significant time*condition interactions; for mood (AMS), time estimate = -0.946, p = .000, condition p = .283, time*condition p = .152.
  • Participants rated blue-enriched light as less comfortable than standard bright light: F(1,20) = 9.61, p = 0.006.

Methods

  • Randomized controlled study in winter 2008–2009 with 22 SAD patients from the University Medical Center Groningen outpatient clinic; 23 were included and 1 dropped out after concussion. SLT group: 3 men and 8 women, mean age 39.9 ± 12.7 years; BLT group: 2 men and 9 women, mean age 41.7 ± 13.1 years.
  • Over a 22-day protocol, patients received 2 weeks of light treatment on 10 workdays for 30 minutes between 7:45 and 8:45 a.m.: SLT at 10,000 lux, 5000°K with EnergyLight, or BLT at 750 lux, 17,000°K with a prototype EnergyLight. Weekly assessments used SIGH-SAD, BDI-II-NL, and SFQ at days 1, 8, 15, and 22; daily assessments used AMS, GSQS, and AD-ACL.
  • Baseline differences were tested with t-tests and chi-square tests; effect sizes were calculated; weekly outcomes were compared with repeated measures ANOVA for completers (n = 11 vs. 11); daily outcomes used linear mixed models with all 22 subjects, including time, condition, time*condition, and baseline score as a covariate.

Limitations

  • The paper states the sample size is very small, so results can only be preliminary.
  • The study had no placebo condition, so the similar responses could be interpreted as placebo effects only; the authors note this cannot be ruled out, though response rates of 65–76% were relatively high compared with placebo responses of 21–41% in prior studies and 36% in their earlier extraocular light study.
  • Evident from the text: the trial was small, single-clinic, mostly female, and had no direct comparison of standard light at 750 lux versus 10,000 lux; follow-up ended at day 22, and participants were not told their condition, though SIGH-SAD interviewers were unaware of treatment assignment.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1186/1471-244x-11-17

Cites

44 of 44 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Spectral-power distributions of the lamps used in the standard EnergyLight® (5000°K) and the specially-prepared EnergyLight® with blue-enriched white light (17 000°K).
Figure 1 Spectral-power distributions of the lamps used in the standard EnergyLight® (5000°K) and the specially-prepared EnergyLight® with blue-enriched white light (17 000°K).CC BY · PubMed Central
Figure 2 Scores on daily self-rating questionnaires assessing mood, sleep quality and four aspects of activation. For abbreviations: see text. Higher scores on the AMS and GSQS mean more symptoms; higher scores on the AD-ACL mean fewer complaints.
Figure 2 Scores on daily self-rating questionnaires assessing mood, sleep quality and four aspects of activation. For abbreviations: see text. Higher scores on the AMS and GSQS mean more symptoms; higher scores on the AD-ACL mean fewer complaints.CC BY · PubMed Central

Verification

Claims the paper makes

9 Valid · 1 Not valid · 9 Not checked · 22 Own results and interpretations

10 more claims

Create a free account to see all 41 claims and to verify the 3 references still open.

See all claims — free account
  • It may state two separate claims as one. 12
  • Probably not a substantial claim. 17
  • The quote only partly states this claim. 1

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Statistics recomputed

Every reported test result, recomputed from its test statistic and degrees of freedom. A result shows as not adding up only once an independent check has confirmed it.

  • ConsistentF(3, 18) = 30.2reported p < .001 · recomputed p < .001

    “F(3,18) = 30.2, p < .001”

  • ConsistentF(1, 20) = 0.012reported n.s. · recomputed p = .914

    “F(1,20) = 0.012, ns”

  • ConsistentF(3, 60) = 0.95reported n.s. · recomputed p = .422

    “F(3,60) = 0.95, ns”

  • ConsistentF(3, 18) = 28.2reported p < .001 · recomputed p < .001

    “F(3,18) = 28.2, p < .001”

  • ConsistentF(1, 20) = 0reported n.s. · recomputed p = 1.000

    “F(1,20) = 0.00, ns”

5 of 16 · the rest aren’t loaded

11 more recomputed tests

Create a free account to see every test the Stats check recomputed.

See all tests — free account

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

2 of 2

Citations

Cites

Show all 43 references

Research works printed but not linked: 6

  1. CIE Central Bureau,Vienna, Austria: Photobiological Safety of Lamps and Lamp Systems, CIE Standard CIE S 009/E. 2002, UDC: 612.014.481
  2. Williams JBW, Link MJ, Rosenthal NE, Amira L, Terman M: Structured Interview Guide for the Hamilton Depression Rating Scale- Seasonal affective disorder version. 1994, New York: New York State Psychiatric Institute
  3. Alberts M, Smets EMA, Vercoulen JHMM, Garssen B, Bleijenberg G: Verkorte Vermoeidheids Vragenlijst: een praktisch hulpmiddel bij het scoren van vermoeidheid. Nederlands Tijdschrift voor de Geneeskunde. 1997, 141: 1526-1530.
  4. Von Zerssen D: Die Befindlichkeitsskala. Manual. 1976, Weinheim: Beltz Test Verlag
  5. Mulder-Hajonides v.d. Meulen WREH, Wijnberg JR, Hollander JJ, De Diana IPF, Van den Hoofdakker RH: Measurement of subjective sleep quality. Fifth European Sleep Congress of the European Sleep Research Society, September, 2-5. 1980, Amsterdam, The Netherlands, 98-[abstract]
  6. Cohen J: Statistical power analysis for the behavioural sciences. 1988, Hillsdale, New Jersey: Lawrence Erlbaum

Cited by

See all 98

Metadata

Authors
Meesters, Y., Dekker, V., Schlangen, L. J., Bos, E. H., & Ruiter, M. J.
Affiliations
  • University Medical Center Groningen (NL)
  • Signify (Netherlands) (NL)
  • University of Groningen (NL)
Corresponding author
Meesters, Ybe
Venue
BMC Psychiatry
Published
2011-01-28
Volume
11
Issue
1
Pages
17-17
ISSN
1471-244X (ISSN-L)
OpenAlex
W1980697377
Cited by
98
References
43
Citations by year
2026: 3 · 2025: 4 · 2024: 4 · 2023: 4 · 2022: 3 · 2021: 6 · 2020: 7 · 2019: 11 · 2018: 9 · 2017: 7 · 2016: 7 · 2015: 6 · 2014: 7 · 2013: 6 · 2012: 9
FWCI
3.84
Type
journal article
Language
en
Open access
Licence
  • cc-by
  • creativecommons.org/licenses/by/2.0 (tdm)
Locations
  • BMC Psychiatry (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • TU/e Research Portal (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
  • University of Groningen research database (University of Groningen / Centre for Information Technology) (submittedVersion, cc-by)
Topics
  • Life Sciences › Neuroscience › Endocrine and Autonomic Systems › Circadian rhythm and melatonin
  • Health Sciences › Medicine › Pharmacology (medical) › Treatment of Major Depression
  • Life Sciences › Agricultural and Biological Sciences › Plant Science › Light effects on plants
Keywords
seasonal affective disorder, phototherapy, low-intensity light, illuminance, photoreceptors, melanopsin, circadian rhythm, mood, sleep quality, energy levels, receptor saturation, short-wavelength light, treatment efficacy comparison
MeSH terms
Adult, Ambulatory Care, Circadian Rhythm, Color, Female, Humans, Light, Male, Phototherapy, Sleep, Seasonal Affective Disorder, Treatment Outcome, Photons, Luminescence

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Low-intensity blue-enriched white light (750 lux) and standard bright light (10 000 lux) are equally effective in treating SAD. A randomized controlled study. https://app.cochat.ai/papers/10.1186/1471-244x-11-17
The paper
Meesters, Y., Dekker, V., Schlangen, L. J., Bos, E. H., & Ruiter, M. J. (2011). Low-intensity blue-enriched white light (750 lux) and standard bright light (10 000 lux) are equally effective in treating SAD. A randomized controlled study. BMC Psychiatry. https://doi.org/10.1186/1471-244x-11-17

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.