The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Rapid detection of Plasmodium falciparum with isothermal recombinase polymerase amplification and lateral flow analysis
Open accessAbstract
BACKGROUND: Nucleic acid amplification is the most sensitive and specific method to detect Plasmodium falciparum. However the polymerase chain reaction remains laboratory-based and has to be conducted by trained personnel. Furthermore, the power dependency for the thermocycling process and the costly equipment necessary for the read-out are difficult to cover in resource-limited settings. This study aims to develop and evaluate a combination of isothermal nucleic acid amplification and simple lateral flow dipstick detection of the malaria parasite for point-of-care testing. METHODS: A specific fragment of the 18S rRNA gene of P. falciparum was amplified in 10 min at a constant 38°C using the isothermal recombinase polymerase amplification (RPA) method. With a unique probe system added to the reaction solution, the amplification product can be visualized on a simple lateral flow strip without further labelling. The combination of these methods was tested for sensitivity and specificity with various Plasmodium and other protozoa/bacterial strains, as well as with human DNA. Additional investigations were conducted to analyse the temperature optimum, reaction speed and robustness of this assay. RESULTS: The lateral flow RPA (LF-RPA) assay exhibited a high sensitivity and specificity. Experiments confirmed a detection limit as low as 100 fg of genomic P. falciparum DNA, corresponding to a sensitivity of approximately four parasites per reaction. All investigated P. falciparum strains (n=77) were positively tested while all of the total 11 non-Plasmodium samples, showed a negative test result. The enzymatic reaction can be conducted under a broad range of conditions from 30-45°C with high inhibitory concentration of known PCR inhibitors. A time to result of 15 min from start of the reaction to read-out was determined. CONCLUSIONS: Combining the isothermal RPA and the lateral flow detection is an approach to improve molecular diagnostic for P. falciparum in resource-limited settings. The system requires none or only little instrumentation for the nucleic acid amplification reaction and the read-out is possible with the naked eye. Showing the same sensitivity and specificity as comparable diagnostic methods but simultaneously increasing reaction speed and dramatically reducing assay requirements, the method has potential to become a true point-of-care test for the malaria parasite.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DNA Detection Using Recombination Proteins
Piepenburg, O., Williams, C. H., Stemple, D. L., & Armes, N. A. (2006) · PLoS Biology · doi:10.1371/journal.pbio.0040204 · Cited by 2,482
Posthuma-Trumpie, G. A., Korf, J., & van Amerongen, A. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2287-2 · Cited by 1,540
Rapid Diagnostic Tests for Malaria Parasites
Moody, A. (2002) · Clinical Microbiology Reviews · doi:10.1128/cmr.15.1.66-78.2002 · Cited by 1,418 · cited 1×
“falciparum and surpasses the analytical sensitivity of malaria microscopy of thin films (200 parasites/μl) [27] and rapid diagnostic tests (RDTs) (>100 parasites/μl) [28] attesting that even low levels of parasitaemia can be detected with this method in a convenient lateral flow immunoassay.”
MethodPurification and Characterization of PCR-Inhibitory Components in Blood Cells
Al-Soud, W. A., & Rådström, P. (2001) · Journal of Clinical Microbiology · doi:10.1128/jcm.39.2.485-493.2001 · Cited by 944
Snounou, G., Viriyakosol, S., Jarra, W., Thaithong, S., & Brown, K. N. (1993) · Molecular and Biochemical Parasitology · doi:10.1016/0166-6851(93)90050-8 · Cited by 906
Singh, B., Bobogare, A., Cox-Singh, J., Snounou, G., Abdullah, M. S., & Rahman, H. A. (1999) · The American journal of tropical medicine and hygiene · doi:10.4269/ajtmh.1999.60.687 · Cited by 590
Poon, L. L., Wong, B. W., Ma, E. H., Chan, K. H., Chow, L. M., Abeyewickreme, W., Tangpukdee, N., Yuen, K. Y., Guan, Y., Looareesuwan, S., et al. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2005.057901 · Cited by 476
Lutz, S., Weber, P., Focke, M., Faltin, B., Hoffmann, J., Müller, C., Mark, D., Roth, G., Munday, P., Armes, N., et al. (2010) · Lab on a Chip · doi:10.1039/b921140c · Cited by 344
World Trade Organization (2012) · World Trade Report · doi:10.30875/ac42f7b8-en · Cited by 331
Han, E.-T., Watanabe, R., Sattabongkot, J., Khuntirat, B., Sirichaisinthop, J., Iriko, H., Jin, L., Takeo, S., & Tsuboi, T. (2007) · Journal of Clinical Microbiology · doi:10.1128/jcm.02117-06 · Cited by 277
Cheng, Q., Cloonan, N., Fischer, K., Thompson, J., Waine, G., Lanzer, M., & Saul, A. (1998) · Molecular and Biochemical Parasitology · doi:10.1016/s0166-6851(98)00144-3 · Cited by 275
A paper and plastic device for performing recombinase polymerase amplification of HIV DNA
Rohrman, B. A., & Richards-Kortum, R. R. (2012) · Lab on a Chip · doi:10.1039/c2lc40423k · Cited by 273
Shokoples, S. E., Ndao, M., Kowalewska-Grochowska, K., & Yanow, S. K. (2009) · Journal of Clinical Microbiology · doi:10.1128/jcm.01858-08 · Cited by 249
PCR as a Confirmatory Technique for Laboratory Diagnosis of Malaria
Johnston, S. P., Pieniazek, N. J., Xayavong, M. V., Slemenda, S. B., Wilkins, P. P., & da Silva, A. J. (2006) · Journal of Clinical Microbiology · doi:10.1128/jcm.44.3.1087-1089.2006 · Cited by 242
Shen, F., Davydova, E. K., Du, W., Kreutz, J. E., Piepenburg, O., & Ismagilov, R. F. (2011) · Analytical Chemistry · doi:10.1021/ac200247e · Cited by 240
Kersting, S., Rausch, V., Bier, F. F., & von Nickisch-Rosenegk, M. (2014) · Microchimica Acta · doi:10.1007/s00604-014-1198-5 · Cited by 183
Self-citationRubio, J. M., Benito, A., Roche, J., Berzosa, P. J., GarcÃa, M. L., Micó, M., Edú, M., & Alvar, J. (1999) · The American journal of tropical medicine and hygiene · doi:10.4269/ajtmh.1999.60.183 · Cited by 172
Polley, S. D., Mori, Y., Watson, J., Perkins, M. D., González, I. J., Notomi, T., Chiodini, P. L., & Sutherland, C. J. (2010) · Journal of Clinical Microbiology · doi:10.1128/jcm.00355-10 · Cited by 167
Anticoagulants Interfere with PCR Used To Diagnose Invasive Aspergillosis
García, M. E., Blanco, J. L., Caballero, J., & Gargallo‐Viola, D. (2002) · Journal of Clinical Microbiology · doi:10.1128/jcm.40.4.1567-1568.2002 · Cited by 123
Demas, A. R., Oberstaller, J., DeBarry, J. D., Lucchi, N. W., Srinivasamoorthy, G., Sumari, D., Kabanywanyi, A. M., Villegas, L., Escalante, A. A., Kachur, S. P., et al. (2011) · Journal of Clinical Microbiology · doi:10.1128/jcm.02603-10 · Cited by 102
Mens, P. F., Schoone, G. J., Kager, P. A., & Schallig, H. D. F. H. (2006) · Malaria Journal · doi:10.1186/1475-2875-5-80 · Cited by 93
Mens, P. F., van Amerongen, A., Sawa, P., Kager, P. A., & Schallig, H. D. F. H. (2008) · Diagnostic Microbiology and Infectious Disease · doi:10.1016/j.diagmicrobio.2008.03.009 · Cited by 92
Effect of ionic and nonionic detergents on the Taq polymerase.
Weyant, R. S., Edmonds, P., & Swaminathan, B. (1990) · PubMed · Cited by 75
Pilot assessment of the sensitivity of the malaria thin film
Ohrt, C., O’Meara, W. P., Remich, S. A., McEvoy, P. L., Ogutu, B. R., Mtalib, R., & Odera, J. S. (2008) · Malaria Journal · doi:10.1186/1475-2875-7-22 · Cited by 35
Molecular test for vivax malaria with loop-mediated isothermal amplification method in central China
Lu, F., Gao, Q., Zhou, H., Cao, J., Wang, W., Lim, C. S., Na, S.-H., Tsuboi, T., & Han, E. (2011) · Parasitology Research · doi:10.1007/s00436-011-2783-8 · Cited by 26
Ongagna-Yhombi, S. Y., Corstjens, P. L. A. M., Geva, E., Abrams, W. R., Barber, C. A., Malamud, D., & Mharakurwa, S. (2013) · Malaria Journal · doi:10.1186/1475-2875-12-74 · Cited by 26
Cited by
Recombinase polymerase amplification: Basics, applications and recent advances
Lobato, I. M., & O'Sullivan, C. K. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2017.10.015 · Cited by 1,146
Recombinase Polymerase Amplification for Diagnostic Applications
Daher, R. K., Stewart, G., Boissinot, M., & Bergeron, M. G. (2016) · Clinical Chemistry · doi:10.1373/clinchem.2015.245829 · Cited by 740
Review: a comprehensive summary of a decade development of the recombinase polymerase amplification
Li, J., Macdonald, J., & von Stetten, F. (2019) · The Analyst · doi:10.1039/c8an01621f · Cited by 648
Nanoparticle-based lateral flow biosensors
Quesada-González, D., & Merkoçi, A. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.05.050 · Cited by 597
Hofmann, N., Mwingira, F., Shekalaghe, S., Robinson, L. J., Mueller, I., & Felger, I. (2015) · PLOS Medicine · doi:10.1371/journal.pmed.1001788 · Cited by 413
Metadata
- Authors
- Kersting, S., Rausch, V., Bier, F. F., & von Nickisch-Rosenegk, M.
- Venue
- Malaria Journal
- Published
- 2014-03-15
- Volume
- 13
- Issue
- 1
- Pages
- 99-99
- ISSN
- 1475-2875 (ISSN-L)
- OpenAlex
- W2114502684
- Cited by
- 287
- References
- 26
- FWCI
- 11.26
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.