Energy harvesting for the implantable biomedical devices: issues and challenges
Open accessThe DOI matches its Crossref record; 73 of the 73 references it cites were found in a registry or an index.
Abstract
The development of implanted devices is essential because of their direct effect on the lives and safety of humanity. This paper presents the current issues and challenges related to all methods used to harvest energy for implantable biomedical devices. The advantages, disadvantages, and future trends of each method are discussed. The concept of harvesting energy from environmental sources and human body motion for implantable devices has gained a new relevance. In this review, the harvesting kinetic, electromagnetic, thermal and infrared radiant energies are discussed. Current issues and challenges related to the typical applications of these methods for energy harvesting are illustrated. Suggestions and discussion of the progress of research on implantable devices are also provided. This review is expected to increase research efforts to develop the battery-less implantable devices with reduced over hole size, low power, high efficiency, high data rate, and improved reliability and feasibility. Based on current literature, we believe that the inductive coupling link is the suitable method to be used to power the battery-less devices. Therefore, in this study, the power efficiency of the inductive coupling method is validated by MATLAB based on suggested values. By further researching and improvements, in the future the implantable and portable medical devices are expected to be free of batteries.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CRC Handbook of Thermoelectrics
(2018) · CRC Press eBooks · doi:10.1201/9781420049718 · Cited by 5,787
Wireless Power Transfer via Strongly Coupled Magnetic Resonances
Kurs, A., Karalis, A., Moffatt, R., Joannopoulos, J. D., Fisher, P., & Soljačić, M. (2007) · Science · doi:10.1126/science.1143254 · Cited by 5,576
Energy harvesting vibration sources for microsystems applications
Beeby, S. P., Tudor, M. J., & White, N. M. (2006) · Measurement Science and Technology · doi:10.1088/0957-0233/17/12/r01 · Cited by 3,008
Rfid Handbook: Fundamentals and Applications in Contactless Smart Cards and Identification
Finkenzeller, K. (2003) · Thammasat University Digital Collections · Cited by 2,150
Energy Harvesting From Human and Machine Motion for Wireless Electronic Devices
Mitcheson, P. D., Yeatman, E. M., Rao, G. K., Holmes, A. S., & Green, T. C. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.927494 · Cited by 1,888
Sample, A. P., Meyer, D. A., & Smith, J. R. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2046002 · Cited by 1,808
Simple accurate expressions for planar spiral inductances
Mohan, S. S., del Mar Hershenson, M., Boyd, S. P., & Lee, T. H. (1999) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.792620 · Cited by 1,627
Efficient wireless non-radiative mid-range energy transfer
Karalis, A., Joannopoulos, J. D., & Soljačić, M. (2008) · Annals of Physics · doi:10.1016/j.aop.2007.04.017 · Cited by 1,394
Energy scavenging with shoe-mounted piezoelectrics
Shenck, N. S., & Paradiso, J. A. (2001) · IEEE Micro · doi:10.1109/40.928763 · Cited by 1,091
RamRakhyani, A. K., Mirabbasi, S., & Chiao, M. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2072782 · Cited by 945
Cited by
Biodegradable triboelectric nanogenerator as a life-time designed implantable power source
Zheng, Q., Zou, Y., Zhang, Y., Liu, Z., Shi, B., Wang, X., Jin, Y., Ouyang, H., Li, Z., & Wang, Z. L. (2016) · Science Advances · doi:10.1126/sciadv.1501478 · Cited by 617
Review of wearable thermoelectric energy harvesting: From body temperature to electronic systems
Nozariasbmarz, A., Collins, H., Dsouza, K., Polash, M. H., Hosseini, M., Hyland, M., Liu, J., Malhotra, A., Ortiz, F. M., Mohaddes, F., et al. (2020) · Applied Energy · doi:10.1016/j.apenergy.2019.114069 · Cited by 588
Fully Bioabsorbable Natural‐Materials‐Based Triboelectric Nanogenerators
Jiang, W., Li, H., Liu, Z., Li, Z., Tian, J., Shi, B., Zou, Y., Ouyang, H., Zhao, C., Zhao, L., et al. (2018) · Advanced Materials · doi:10.1002/adma.201801895 · Cited by 449
An autonomous actuator driven by fluctuations in ambient humidity
Arazoe, H., Miyajima, D., Akaike, K., Araoka, F., Sato, E., Hikima, T., Kawamoto, M., & Aida, T. (2016) · Nature Materials · doi:10.1038/nmat4693 · Cited by 435
Liu, L., Guo, X., & Lee, C. (2021) · Nano Energy · doi:10.1016/j.nanoen.2021.106304 · Cited by 402
Shin, G., Gomez, A. M., Al-Hasani, R., Jeong, Y. R., Kim, J., Xie, Z., Banks, A., Lee, S. M., Han, S. Y., Yoo, C. J., et al. (2017) · Neuron · doi:10.1016/j.neuron.2016.12.031 · Cited by 396
“These implantable devices, which use the HF band, overcome the limited operational range associated with previously reported systems (Hannan et al., 2014; Harrison et al., 2009).”
An overview of lead-free piezoelectric materials and devices
Wei, H., Wang, H., Xia, Y., Cui, D., Shi, Y., Dong, M., Liu, C., Ding, T., Zhang, J., Ma, Y., et al. (2018) · Journal of Materials Chemistry C · doi:10.1039/c8tc04515a · Cited by 393
Portable biosensing devices for point-of-care diagnostics: Recent developments and applications
Zarei, M. (2017) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2017.04.001 · Cited by 326
Siddiqui, S., Kim, D.-I., Duy, L. T., Nguyen, M. T., Muhammad, S., Yoon, W.-S., & Lee, N.-E. (2015) · Nano Energy · doi:10.1016/j.nanoen.2015.04.030 · Cited by 263
Advances in closed-loop deep brain stimulation devices
Parastarfeizabadi, M., & Kouzani, A. Z. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0295-1 · Cited by 232
Self‐Powered Implantable Medical Devices: Photovoltaic Energy Harvesting Review
Zhao, J., Ghannam, R., Htet, K. O., Liu, Y., Law, M., Roy, V. A. L., Michel, B., Imran, M. A., & Heidari, H. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.202000779 · Cited by 218
A review of acoustic power transfer for bio-medical implants
Basaeri, H., Christensen, D. B., & Roundy, S. (2016) · Smart Materials and Structures · doi:10.1088/0964-1726/25/12/123001 · Cited by 202
Recent progress in human body energy harvesting for smart bioelectronic system
Zou, Y., Bo, L., & Li, Z. (2021) · Fundamental Research · doi:10.1016/j.fmre.2021.05.002 · Cited by 187
Advances in point-of-care technologies for molecular diagnostics
Zarei, M. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.07.024 · Cited by 184
Additive manufacturing of hydrogel-based materials for next-generation implantable medical devices
Chin, S. Y., Poh, Y. C., Kohler, A.-C., Compton, J. T., Hsu, L. L., Lau, K. M., Kim, S., Lee, B. W., Lee, F. Y., & Sia, S. K. (2017) · Science Robotics · doi:10.1126/scirobotics.aah6451 · Cited by 172
Lyu, H., Wang, J., La, J.-H., Chung, J. M., & Babakhani, A. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2852680 · Cited by 47
Lyu, H., Gad, P., Zhong, H., Edgerton, V. R., & Babakhani, A. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2879357 · Cited by 26
Super-capacitors for implantable medical devices with wireless power transmission
Mendoza-Ponce, P., John, B., Schroeder, D., & Krautschneider, W. H. (2018) · 2018 14th Conference on Ph.D. Research in Microelectronics and Electronics (PRIME) · doi:10.1109/prime.2018.8430360 · Cited by 19
“Battery and wireless power links are commonly used as energy sources for implantable devices since the energy scavenging technique is limited by its energy density [1].”
BackgroundAmbulatory cardiac bio-signals: From mirage to clinical reality through a decade of progress
Periyaswamy, T., & Balasubramanian, M. (2019) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2019.07.007 · Cited by 14
Pressure Simulation for Footstep Energy Harvesting Paver
Chand, A. A., Prasad, K. A., Singh, S., Islam, F. R., Cirrincione, M., Mamun, K. A., & Narayan, S. (2019) · 2019 IEEE International Conference on Sensors and Nanotechnology · doi:10.1109/sensorsnano44414.2019.8940093 · Cited by 7
“According to literature [6-11], the key mechanics to harvest footstep kinetic energy is through the use of piezoelectric, electrostatic, electromagnetic and magnetostrictive materials.”
Background
Metadata
- Authors
- Hannan, M. A., Mutashar, S., Samad, S. A., & Hussain, A.
- Venue
- BioMedical Engineering OnLine
- Published
- 2014-06-20
- Volume
- 13
- Issue
- 1
- Pages
- 79-79
- ISSN
- 1475-925X (ISSN-L)
- OpenAlex
- W2170280734
- Cited by
- 322
- References
- 73
- FWCI
- 28.05
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.