The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Surface EMG pattern recognition for real-time control of a wrist exoskeleton
Open accessAbstract
Background: Surface electromyography (sEMG) signals have been used in numerous studies for the classification of hand gestures and movements and successfully implemented in the position control of different prosthetic hands for amputees. sEMG could also potentially be used for controlling wearable devices which could assist persons with reduced muscle mass, such as those suffering from sarcopenia. While using sEMG for position control, estimation of the intended torque of the user could also provide sufficient information for an effective force control of the hand prosthesis or assistive device. This paper presents the use of pattern recognition to estimate the torque applied by a human wrist and its real-time implementation to control a novel two degree of freedom wrist exoskeleton prototype (WEP), which was specifically developed for this work. Methods: Both sEMG data from four muscles of the forearm and wrist torque were collected from eight volunteers by using a custom-made testing rig. The features that were extracted from the sEMG signals included root mean square (rms) EMG amplitude, autoregressive (AR) model coefficients and waveform length. Support Vector Machines (SVM) was employed to extract classes of different force intensity from the sEMG signals. After assessing the off-line performance of the used classification technique, the WEP was used to validate in real-time the proposed classification scheme. Results: The data gathered from the volunteers were divided into two sets, one with nineteen classes and the second with thirteen classes. Each set of data was further divided into training and testing data. It was observed that the average testing accuracy in the case of nineteen classes was about 88% whereas the average accuracy in the case of thirteen classes reached about 96%. Classification and control algorithm implemented in the WEP was executed in less than 125 ms. Conclusions: The results of this study showed that classification of EMG signals by separating different levels of torque is possible for wrist motion and the use of only four EMG channels is suitable. The study also showed that SVM classification technique is suitable for real-time classification of sEMG signals and can be effectively implemented for controlling an exoskeleton device for assisting the wrist.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LIBSVM: A library for support vector machines
Chang, C.-C., & Lin, C.-J. (2011) · ACM Transactions on Intelligent Systems and Technology · doi:10.1145/1961189.1961199 · Cited by 40,918
Book Review: Pattern Recognition and Machine Learning
Nasrabadi, N. M. (2007) · Journal of Electronic Imaging · doi:10.1117/1.2819119 · Cited by 22,066
Libsvm : A library for support vector machines
Ferrari, V. (2008) · Medical Entomology and Zoology · Cited by 10,122
Pattern Recognition and Machine Learning
(2006) · doi:10.1007/978-0-387-45528-0 · Cited by 9,824
A Practical Guide to Support Vector Classication
Hsu, C., Chang, C.-C., & Lin, C. (2008) · Cited by 5,046
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149 · cited 5×
“Feature extraction is the dimensionality reduction of the raw sEMG input to form a feature vector - the accuracy of the pattern classification system almost entirely depends on the choice of these features [11].”
BackgroundInfluentialA robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
Techniques of EMG signal analysis: detection, processing, classification and applications
Reaz, M. B. I., Hussain, M. S., & Mohd-Yasin, F. (2006) · Biological Procedures Online · doi:10.1251/bpo115 · Cited by 1,629
Lum, P. S., Burgar, C. G., Shor, P. C., Majmundar, M., & Van der Loos, M. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.33101 · Cited by 1,159 · cited 1×
“Combining sEMG signals with robotic therapy can optimize the coordination of motor commands and actual movement [4-6].”
BackgroundSupport Vector Machine-Based Classification Scheme for Myoelectric Control Applied to Upper Limb
Oskoei, M. A., & Hu, H. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.919734 · Cited by 829
The Entire Regularization Path for the Support Vector Machine
Hastie, T. J., Rosset, S., Tibshirani, R. J., & Zhu, J. (2004) · Journal of Machine Learning Research · Cited by 748
A wavelet-based continuous classification scheme for multifunction myoelectric control
Englehart, K., Hudgin, B., & Parker, P. A. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914793 · Cited by 697 · cited 2×
“Different studies have been performed to tackle this challenge by using different pattern recognition methods [11-28].”
BackgroundClassification of the myoelectric signal using time-frequency based representations
Englehart, K., Hudgins, B., Parker, P. A., & Stevenson, M. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00066-1 · Cited by 645
The Support Vector Method of Function Estimation
Vapnik, V. (1998) · Nonlinear Modeling · doi:10.1007/978-1-4615-5703-6_3 · Cited by 630
The optimal controller delay for myoelectric prostheses
Farrell, T. R., & Weir, R. F. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.891391 · Cited by 438
Surface EMG in advanced hand prosthetics
Castellini, C., & van der Smagt, P. (2009) · Biological Cybernetics · doi:10.1007/s00422-008-0278-1 · Cited by 429
Multiclass Support Vector Machines for EEG-Signals Classification
Guler, I., & Ubeyli, E. D. (2007) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2006.879600 · Cited by 404
Fuzzy EMG classification for prosthesis control
Chan, F. H. Y., Yang, Y.-S., Lam, F. K., Zhang, Y.-T., & Parker, P. A. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.867872 · Cited by 376
Khandoker, A. H., Palaniswami, M., & Karmakar, C. K. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2008.2004495 · Cited by 367
Chu, J.-U., Moon, I., & Mun, M.-S. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.883695 · Cited by 352
Continuous Myoelectric Control for Powered Prostheses Using Hidden Markov Models
Chan, A. D. C., & Englehart, K. B. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.836492 · Cited by 343
Chu, J.-U., Moon, I., Lee, Y.-J., Kim, S.-K., & Mun, M.-S. (2007) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2007.897262 · Cited by 299
KALMUS, H. (1972) · Nature · doi:10.1038/237055b0 · Cited by 274
Heartbeat Time Series Classification With Support Vector Machines
Kampouraki, A., Manis, G., & Nikou, C. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2008.2003323 · Cited by 254
Learning EMG control of a robotic hand: towards active prostheses
Bitzer, S., & van der Smagt, P. (2006) · Proceedings 2006 IEEE International Conference on Robotics and Automation, 2006. ICRA 2006. · doi:10.1109/robot.2006.1642128 · Cited by 245
A fuzzy clustering neural network architecture for multifunction upper-limb prosthesis
Karlik, B., Tokhi, M. O., & Alci, M. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.818469 · Cited by 198
EMG pattern recognition based on artificial intelligence techniques
Park, S.-H., & Lee, S.-P. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.736154 · Cited by 197
Stein, J., Narendran, K., McBean, J., Krebs, K., & Hughes, R. (2007) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e3180383cc5 · Cited by 170
Real-time intelligent pattern recognition algorithm for surface EMG signals
Khezri, M., & Jahed, M. (2007) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-6-45 · Cited by 166
Development of a myoelectric discrimination system for a multi-degree prosthetic hand
Huang, H.-P., & Chen, C.-Y. (2003) · Proceedings 1999 IEEE International Conference on Robotics and Automation (Cat. No.99CH36288C) · doi:10.1109/robot.1999.770463 · Cited by 162
Soares, A. B., Andrade, A. D. O., Júnior, E. A. L., & Carrijo, R. S. (2003) · Journal of Intelligent Information Systems · doi:10.1023/a:1024758415877 · Cited by 152
Recognition of Electromyographic Signals Using Cascaded Kernel Learning Machine
Liu, Y., Huang, H., & Weng, C.-H. (2007) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2007.897253 · Cited by 121
A myoelectric interface for robotic hand control using support vector machine
Yoshikawa, M., Mikawa, M., & Tanaka, K. (2007) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2007.4399301 · Cited by 70
An Assessment of Robot-Assisted Bimanual Movements on Upper Limb Motor Coordination Following Stroke
Lewis, G. N., & Perreault, E. J. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2029315 · Cited by 60
A Novel Concept for a Prosthetic Hand With a Bidirectional Interface: A Feasibility Study
Cipriani, C., Antfolk, C., Balkenius, C., Rosén, B., Lundborg, G., Carrozza, M. C., & Sebelius, F. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2031242 · Cited by 50
Chu, J., & Lee, Y.-J. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2015177 · Cited by 35
Enhancing the Performance of LibSVM Classifier by Kernel F-Score Feature Selection
Balakrishnan, S., Narayanasamy, R., & Savarimuthu, N. (2009) · Communications in computer and information science · doi:10.1007/978-3-642-03547-0_51 · Cited by 17
Cited by
A survey of sensor fusion methods in wearable robotics
Novak, D., & Riener, R. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.012 · Cited by 252
Metadata
- Authors
- Khokhar, Z. O., Xiao, Z. G., & Menon, C.
- Venue
- BioMedical Engineering OnLine
- Published
- 2010-08-26
- Volume
- 9
- Issue
- 1
- Pages
- 41-41
- ISSN
- 1475-925X (ISSN-L)
- OpenAlex
- W2134123560
- Cited by
- 258
- References
- 37
- FWCI
- 5.28
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.