Evaluation of current algorithms for segmentation of scar tissue from late Gadolinium enhancement cardiovascular magnetic resonance of the left atrium: an open-access grand challenge
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Late Gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) imaging can be used to visualise regions of fibrosis and scarring in the left atrium (LA) myocardium. This can be important for treatment stratification of patients with atrial fibrillation (AF) and for assessment of treatment after radio frequency catheter ablation (RFCA). In this paper we present a standardised evaluation benchmarking framework for algorithms segmenting fibrosis and scar from LGE CMR images. The algorithms reported are the response to an open challenge that was put to the medical imaging community through an ISBI (IEEE International Symposium on Biomedical Imaging) workshop. METHODS: The image database consisted of 60 multicenter, multivendor LGE CMR image datasets from patients with AF, with 30 images taken before and 30 after RFCA for the treatment of AF. A reference standard for scar and fibrosis was established by merging manual segmentations from three observers. Furthermore, scar was also quantified using 2, 3 and 4 standard deviations (SD) and full-width-at-half-maximum (FWHM) methods. Seven institutions responded to the challenge: Imperial College (IC), Mevis Fraunhofer (MV), Sunnybrook Health Sciences (SY), Harvard/Boston University (HB), Yale School of Medicine (YL), King's College London (KCL) and Utah CARMA (UTA, UTB). There were 8 different algorithms evaluated in this study. RESULTS: Some algorithms were able to perform significantly better than SD and FWHM methods in both pre- and post-ablation imaging. Segmentation in pre-ablation images was challenging and good correlation with the reference standard was found in post-ablation images. Overlap scores (out of 100) with the reference standard were as follows: Pre: IC = 37, MV = 22, SY = 17, YL = 48, KCL = 30, UTA = 42, UTB = 45; Post: IC = 76, MV = 85, SY = 73, HB = 76, YL = 84, KCL = 78, UTA = 78, UTB = 72. CONCLUSIONS: The study concludes that currently no algorithm is deemed clearly better than others. There is scope for further algorithmic developments in LA fibrosis and scar quantification from LGE CMR images. Benchmarking of future scar segmentation algorithms is thus important. The proposed benchmarking framework is made available as open-source and new participants can evaluate their algorithms via a web-based interface.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood from Incomplete Data Via the EM Algorithm
Dempster, A. P., Laird, N. M., & Rubin, D. B. (1977) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1977.tb01600.x · Cited by 50,444 · cited 1×
“The expectation-maximization (EM) algorithm [27] is a technique for estimating model parameters given the observed data.”
MethodA Computational Approach to Edge Detection
Canny, J. (1986) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1986.4767851 · Cited by 30,004
Textural Features for Image Classification
Haralick, R. M., Shanmugam, K., & Dinstein, I. (1973) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1973.4309314 · Cited by 22,886 · cited 1×
“[30] were tested.”
Kass, M., Witkin, A., & Terzopoulos, D. (1988) · International Journal of Computer Vision · doi:10.1007/bf00133570 · Cited by 17,070 · cited 1×
“Active contours [26] was used in this technique to obtain the epicardial boundary.”
MethodMarching cubes: A high resolution 3D surface construction algorithm
Lorensen, W. E., & Cline, H. E. (1987) · Proceedings of the 14th annual conference on Computer graphics and interactive techniques · doi:10.1145/37401.37422 · Cited by 10,104 · cited 1×
“The LA surface can be constructed as an iso-surface from a volumetric binary segmentation using the marching cubes algorithm [34].”
MethodMarching cubes: A high resolution 3D surface construction algorithm
Lorensen, W. E., & Cline, H. E. (1987) · ACM SIGGRAPH Computer Graphics · doi:10.1145/37402.37422 · Cited by 8,647
Fast approximate energy minimization via graph cuts
Boykov, Y., Veksler, O., & Zabih, R. (2001) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.969114 · Cited by 6,988
A Fuzzy Relative of the ISODATA Process and Its Use in Detecting Compact Well-Separated Clusters
Dunn, J. C. (1973) · Journal of Cybernetics · doi:10.1080/01969727308546046 · Cited by 5,049
Kim, R. J., Fieno, D. S., Parrish, T. B., Harris, K., Chen, E.-L., Simonetti, O., Bundy, J., Finn, J. P., Klocke, F. J., & Judd, R. M. (1999) · Circulation · doi:10.1161/01.cir.100.19.1992 · Cited by 2,581 · cited 2×
“[9] Canine 26 CMR LV SD Infarct size, ex-vivo”
BackgroundMethodMaximal Flow Through a Network
Ford, L. R., & Fulkerson, D. R. (1956) · Canadian Journal of Mathematics · doi:10.4153/cjm-1956-045-5 · Cited by 2,410 · cited 1×
“The minimum cut and maximum flow are dual problems both investigated thoroughly in mathematics [20,21] and computer vision [22,23].”
BackgroundWarfield, S. K., Zou, K. H., & Wells, W. M. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.828354 · Cited by 2,335 · cited 2×
“It was thus important to merge the segmentations with STAPLE [31].”
MethodGraph Cuts and Efficient N-D Image Segmentation
Boykov, Y., & Funka-Lea, G. (2006) · International Journal of Computer Vision · doi:10.1007/s11263-006-7934-5 · Cited by 1,910
A new approach to the maximum-flow problem
Goldberg, A. V., & Tarjan, R. E. (1988) · Journal of the ACM · doi:10.1145/48014.61051 · Cited by 1,882 · cited 1×
“The minimum cut and maximum flow are dual problems both investigated thoroughly in mathematics [20,21] and computer vision [22,23].”
BackgroundMaximal Flow Through a Network
Ford, L. R., & Fulkerson, D. R. (2009) · Classic Papers in Combinatorics · doi:10.1007/978-0-8176-4842-8_15 · Cited by 1,829
Oakes, R. S., Badger, T. J., Kholmovski, E. G., Akoum, N., Burgon, N. S., Fish, E. N., Blauer, J. J. E., Rao, S. N., DiBella, E. V. R., Segerson, N. M., et al. (2009) · Circulation · doi:10.1161/circulationaha.108.811877 · Cited by 1,123 · cited 8×
“Eight different algorithms were evaluated with the proposed framework, three of which are published or slightly modified versions of published techniques ([5,15,18]).”
BackgroundMethodInfluentialSelf-citationSchmidt, A., Azevedo, C. F., Cheng, A., Gupta, S. N., Bluemke, D. A., Foo, T. K., Gerstenblith, G., Weiss, R. G., Marbán, E., Tomaselli, G. F., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.653568 · Cited by 823 · cited 2×
“A common method for detecting fibrosis or scar is the application of a threshold two or three standard deviations above the average intensity value of a healthy myocardial region [9-11].”
BackgroundMethodYan, A. T., Shayne, A. J., Brown, K. A., Gupta, S. N., Chan, C. W., Luu, T. M., Di Carli, M. F., Reynolds, H. G., Stevenson, W. G., & Kwong, R. Y. (2006) · Circulation · doi:10.1161/circulationaha.106.613414 · Cited by 750 · cited 2×
“Others such as the full-width-at-half-maximum (FWHM) can be used [12] and some use thresholding to further classify scar into core or peri-core regions [13].”
BackgroundMethodFlett, A. S., Hasleton, J., Cook, C., Hausenloy, D., Quarta, G., Ariti, C., Muthurangu, V., & Moon, J. C. (2011) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2010.11.015 · Cited by 690
Kramer, C. M., Barkhausen, J., Flamm, S. D., Kim, R. J., & Nagel, E. (2008) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-10-35 · Cited by 688
Amado, L. C., Gerber, B. L., Gupta, S. N., Rettmann, D. W., Szarf, G., Schock, R., Nasir, K., Kraitchman, D. L., & Lima, J. A. C. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.09.020 · Cited by 508 · cited 3×
“The FWHM was implemented as described in [12] with manual selection of”
MethodPeters, D. C., Wylie, J. V., Hauser, T. H., Kissinger, K. V., Botnar, R. M., Essebag, V., Josephson, M. E., & Manning, W. J. (2007) · Radiology · doi:10.1148/radiol.2433060417 · Cited by 336 · cited 2×
“Recent work has demonstrated its use in assessment of atrial fibrosis before ablation and of atrial injury after ablation [4-8].”
BackgroundSelf-citationMahnkopf, C., Badger, T. J., Burgon, N. S., Daccarett, M., Haslam, T. S., Badger, C. T., McGann, C. J., Akoum, N., Kholmovski, E., Macleod, R. S., et al. (2010) · Heart Rhythm · doi:10.1016/j.hrthm.2010.06.030 · Cited by 334 · cited 1×
“Recent work has demonstrated its use in assessment of atrial fibrosis before ablation and of atrial injury after ablation [4-8].”
BackgroundSelf-citationBadger, T. J., Daccarett, M., Akoum, N. W., Adjei-Poku, Y. A., Burgon, N. S., Haslam, T. S., Kalvaitis, S., Kuppahally, S., Vergara, G., McMullen, L., et al. (2010) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.109.868356 · Cited by 212 · cited 1×
“Recent work has demonstrated its use in assessment of atrial fibrosis before ablation and of atrial injury after ablation [4-8].”
BackgroundSelf-citationKirişli, H. A., Schaap, M., Metz, C. T., Dharampal, A. S., Meijboom, W. B., Papadopoulou, S. L., Dedic, A., Nieman, K., de Graaf, M. A., Meijs, M. F. L., et al. (2013) · Medical Image Analysis · doi:10.1016/j.media.2013.05.007 · Cited by 205
Benchmarking framework for myocardial tracking and deformation algorithms: An open access database
Tobon-Gomez, C., De Craene, M., McLeod, K., Tautz, L., Shi, W., Hennemuth, A., Prakosa, A., Wang, H., Carr-White, G., Kapetanakis, S., et al. (2013) · Medical Image Analysis · doi:10.1016/j.media.2013.03.008 · Cited by 171 · cited 1×
“In the cardiac imaging domain, some recent challenges include cardiac motion tracking [1] and coronary artery stenosis detection [2].”
BackgroundSelf-citationHALL, B. W., Jeevanantham, V., Simon, R. A., Filippone, J. D., Vorobiof, G., & Daubert, J. P. (2007) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-006-9052-2 · Cited by 109
Segmentation of non-viable myocardium in delayed enhancement magnetic resonance images
Kolipaka, A., Chatzimavroudis, G. P., White, R. D., O’Donnell, T., & Setser, R. M. (2005) · International journal of cardiac imaging · doi:10.1007/s10554-004-5806-z · Cited by 106 · cited 3×
“Other approaches exist to compute the threshold automatically [10] or apply clustering [14,16], or with Graph-cuts [18].”
MethodA Comprehensive Approach to the Analysis of Contrast Enhanced Cardiac MR Images
Hennemuth, A., Seeger, A., Friman, O., Miller, S., Klumpp, B. D., Oeltze‐Jafra, S., & Peitgen, H. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2006512 · Cited by 95 · cited 3×
“Eight different algorithms were evaluated with the proposed framework, three of which are published or slightly modified versions of published techniques ([5,15,18]).”
BackgroundMethodSelf-citationTao, Q., Milles, J., Zeppenfeld, K., Lamb, H. J., Bax, J. J., Reiber, J. H. C., & van der Geest, R. J. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22422 · Cited by 84 · cited 1×
“[17] Human 20 CMR LV Otsu thresholding Dice”
Method
Cited by
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2018) · EP Europace · doi:10.1093/europace/eux274 · Cited by 1,164
Evaluation of algorithms for Multi-Modality Whole Heart Segmentation: An open-access grand challenge
Zhuang, X., Li, L., Payer, C., Štern, D., Urschler, M., Heinrich, M. P., Oster, J., Wang, C., Smedby, Ö., Bian, C., et al. (2019) · Medical Image Analysis · doi:10.1016/j.media.2019.101537 · Cited by 361
Self-citationJiao, R., Zhang, Y., Ding, L., Xue, B., Zhang, J., Cai, R., & Jin, C. (2024) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2023.107840 · Cited by 345
UniverSeg: Universal Medical Image Segmentation
Butoi, V. I., Gonzalez Ortiz, J. J., Ma, T., Sabuncu, M. R., Guttag, J., & Dalca, A. V. (2023) · 2023 IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv51070.2023.01960 · Cited by 195
Metadata
- Authors
- Karim, R., Housden, R. J., Balasubramaniam, M., Chen, Z., Perry, D., Uddin, A., Al-Beyatti, Y., Palkhi, E., Acheampong, P., Obom, S., Hennemuth, A., Lu, Y., Bai, W., Shi, W., Gao, Y., Peitgen, H.-O., Radau, P., Razavi, R., Tannenbaum, A., Rueckert, D., Cates, J., Schaeffter, T., Peters, D., MacLeod, R., & Rhode, K.
- Venue
- Journal of Cardiovascular Magnetic Resonance
- Publisher
- Elsevier BV
- Published
- 2013-01
- Volume
- 15
- Issue
- 1
- Pages
- 105
- ISSN
- 1097-6647 (ISSN-L)
- OpenAlex
- W2003590746
- Cited by
- 172
- References
- 29
- FWCI
- 13.75
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.