T1 and extracellular volume mapping in the heart: estimation of error maps and the influence of noise on precision
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Quantitative measurements in the myocardium may be used to detect both focal and diffuse disease processes that result in an elevation of T1 and/or extracellular volume (ECV) fraction. Detection of abnormal myocardial tissue by these methods is affected by both the accuracy and precision. The sensitivity for detecting abnormal elevation of T1 and ECV is limited by the precision of T1 estimates which is a function of the number and timing of measurements along the T1-inversion recovery curve, the signal-to-noise ratio (SNR), the tissue T1, and the method of fitting. METHODS: The standard deviation (SD) of T1 and ECV estimates are formulated and SD maps are calculated on a pixel-wise basis using the Modified Look-Locker Inversion recovery (MOLLI) method. SD estimates are validated by numerical simulation using Monte-Carlo analysis and with phantoms using repeated trials. SD estimates are provided for pre- and post-contrast optimized protocols for a range of T1s and SNRs. In-vivo examples are provide for normal, myocarditis, and HCM in human subjects. The formulation of SD maps was extended to R1 and ECV. RESULTS: The measured myocardial SNR ranged from 23 to 43 across the heart using the specific T1-mapping protocol in this study. In this range of SNRs, the estimated SD for T1 was approximately 20-45 ms for pre-contrast myocardial T1 around 1000 ms, and was approximately 10-20 ms for post contrast T1 around 400 ms. The proposed estimate of SD was an unbiased estimate of the standard deviation of T1 validated by numerical simulation and had > 99% correlation with phantom measurements. The measured SD maps exhibited variation across the heart due to drop off in surface coil sensitivity as expected for the variation in SNR. Focal elevation in T1 and ECV was shown to have statistical significance on a pixel-wise basis for in-vivo examples. CONCLUSIONS: Pixel-wise estimates of T1 mapping errors have been formulated and validated, and the formulation has been extended to ECV. The ability to quantify the measurement error has potential to determine the statistical significance of subtle abnormalities that arise due to diffuse disease processes involving fibrosis and/or edema and is useful both as a confidence metric for overall quality, and in optimization and comparison of imaging protocols.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Simplex Method for Function Minimization
Nelder, J. A., & Mead, R. (1965) · The Computer Journal · doi:10.1093/comjnl/7.4.308 · Cited by 28,905 · cited 1×
“and the measurements y(t) may be fit for the unknown parameters (A, B, T1) at each pixel using a downhill simplex minimization approach (Nelder–Mead method) [24].”
MethodThe Influence Curve and its Role in Robust Estimation
Hampel, F. R. (1974) · Journal of the American Statistical Association · doi:10.1080/01621459.1974.10482962 · Cited by 2,706 · cited 1×
“Additionally, a robust estimation of the underlying standard deviation (σ) from the fit residuals is used based on the median absolute deviation (MAD) approach [26,28].”
MethodRobust regression using iteratively reweighted least-squares.
Holland, P. W., & Welsch, R. E. (1977) · Communications in Statistics - Theory and Methods · doi:10.1080/03610927708827533 · Cited by 2,115 · cited 1×
“Robust fitting [26,27] uses iterative reweighting to improve the fit in the presence of outliers.”
MethodModified Look‐Locker inversion recovery (MOLLI) for high‐resolution T1 mapping of the heart
Messroghli, D. R., Radjenovic, A., Kozerke, S., Higgins, D. M., Sivananthan, M. U., & Ridgway, J. P. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20110 · Cited by 1,349 · cited 6×
“In applications such as cardiac MR, a modified Look-Locker (MOLLI) method [9,10] uses inversion recovery with multiple single shot images at different inversion times.”
BackgroundMethodInfluentialFlett, A. S., Hayward, M. P., Ashworth, M. T., Hansen, M. S., Taylor, A. M., Elliott, P. M., McGregor, C., & Moon, J. C. (2010) · Circulation · doi:10.1161/circulationaha.109.930636 · Cited by 915
Noncontrast T1 Mapping for the Diagnosis of Cardiac Amyloidosis
Karamitsos, T. D., Piechnik, S. K., Banypersad, S. M., Fontana, M., Ntusi, N. B., Ferreira, V. M., Whelan, C. J., Myerson, S. G., Robson, M. D., Hawkins, P. N., et al. (2013) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2012.11.013 · Cited by 676 · cited 3×
“Direct measurement of extracellular volume (ECV) was initially developed for quantifying the myocardial extracellular fractional distribution volume [1] and has been proposed as a means for detection and quantification of diffuse myocardial fibrosis [2-6,15-17].”
BackgroundMethodPiechnik, S. K., Ferreira, V. M., Dall'Armellina, E., Cochlin, L. E., Greiser, A., Neubauer, S., & Robson, M. D. (2010) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-12-69 · Cited by 670 · cited 2×
“The T1-mapping protocols 5(3)3 and 4(1)3(1)2 used in this study are compared in Figure 13 with the widely used original MOLLI protocol 3(3)3(3)5 and the shortened MOLLI protocol 5(1)1(1)1 [12] over a range of T1 at an SNR = 25.”
MethodUgander, M., Oki, A. J., Hsu, L.-Y., Kellman, P., Greiser, A., Aletras, A. H., Sibley, C. T., Chen, M. Y., Bandettini, W. P., & Arai, A. E. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehr481 · Cited by 576
Self-citationSado, D. M., White, S. K., Piechnik, S. K., Banypersad, S. M., Treibel, T., Captur, G., Fontana, M., Maestrini, V., Flett, A. S., Robson, M. D., et al. (2013) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.112.000070 · Cited by 541 · cited 4×
“Direct measurement of extracellular volume (ECV) was initially developed for quantifying the myocardial extracellular fractional distribution volume [1] and has been proposed as a means for detection and quantification of diffuse myocardial fibrosis [2-6,15-17].”
BackgroundMethodInfluentialImage reconstruction in SNR units: A general method for SNR measurement†
Kellman, P., & McVeigh, E. R. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20713 · Cited by 535
Self-citationHuman non-contrast T1 values and correlation with histology in diffuse fibrosis
Bull, S., White, S. K., Piechnik, S. K., Flett, A. S., Ferreira, V. M., Loudon, M., Francis, J. M., Karamitsos, T. D., Prendergast, B. D., Robson, M. D., et al. (2013) · Heart · doi:10.1136/heartjnl-2012-303052 · Cited by 463 · cited 2×
“Direct measurement of extracellular volume (ECV) was initially developed for quantifying the myocardial extracellular fractional distribution volume [1] and has been proposed as a means for detection and quantification of diffuse myocardial fibrosis [2-6,15-17].”
MethodExtracellular volume fraction mapping in the myocardium, part 1: evaluation of an automated method
Kellman, P., Wilson, J. R., Xue, H., Ugander, M., & Arai, A. E. (2012) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-14-63 · Cited by 427 · cited 3×
“Co-registration between preand post-contrast acquired image series was performed in the generation of ECV maps [13].”
MethodSelf-citationQuantification of T1 values by SNAPSHOT-FLASH NMR imaging
Deichmann, R., & Haase, A. (1992) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(92)90347-a · Cited by 406 · cited 1×
“The desired T1 is then calculated at each pixel using T1 = T1*·(B/A-1), referred to as the Look-Locker correction, originally derived from considering a continuous fast low angle shot (FLASH) gradient echo readout [19].”
MethodArheden, H., Saeed, M., Higgins, C. B., Gao, D.-W., Bremerich, J., Wyttenbach, R., Dae, M. W., & Wendland, M. F. (1999) · Radiology · doi:10.1148/radiology.211.3.r99jn41698 · Cited by 358 · cited 2×
“Direct measurement of extracellular volume (ECV) was initially developed for quantifying the myocardial extracellular fractional distribution volume [1] and has been proposed as a means for detection and quantification of diffuse myocardial fibrosis [2-6,15-17].”
MethodMessroghli, D. R., Greiser, A., Fröhlich, M., Dietz, R., & Schulz‐Menger, J. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21119 · Cited by 353 · cited 3×
“In applications such as cardiac MR, a modified Look-Locker (MOLLI) method [9,10] uses inversion recovery with multiple single shot images at different inversion times.”
MethodMyocardial T1 mapping: Application to patients with acute and chronic myocardial infarction
Messroghli, D. R., Walters, K., Plein, S., Sparrow, P., Friedrich, M. G., Ridgway, J. P., & Sivananthan, M. U. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21272 · Cited by 351 · cited 3×
“For longer values of T1 where it has been shown that the original MOLLI becomes heart rate dependent [11] the 5(3)3”
BackgroundMethodPiechnik, S. K., Ferreira, V. M., Lewandowski, A. J., Ntusi, N. A., Banerjee, R., Holloway, C., Hofman, M. B., Sado, D. M., Maestrini, V., White, S. K., et al. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-13 · Cited by 273 · cited 1×
“Although absolute accuracy of in-vivo measurements is an important and open subject, these methods have been shown to be highly reproducible [18] in practice despite bias errors.”
MethodBroberg, C. S., Chugh, S. S., Conklin, C., Sahn, D. J., & Jerosch-Herold, M. (2010) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.108.842096 · Cited by 262 · cited 3×
“Direct measurement of extracellular volume (ECV) was initially developed for quantifying the myocardial extracellular fractional distribution volume [1] and has been proposed as a means for detection and quantification of diffuse myocardial fibrosis [2-6,15-17].”
BackgroundMethodExtracellular volume fraction mapping in the myocardium, part 2: initial clinical experience
Kellman, P., Wilson, J. R., Xue, H., Bandettini, W. P., Shanbhag, S. M., Druey, K. M., Ugander, M., & Arai, A. E. (2012) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-14-64 · Cited by 259 · cited 1×
“Background Quantitative methods such as T1-mapping and extracellular volume (ECV) mapping appear promising to complement LGE imaging in cases of more homogeneously diffuse disease which affect the myocardial extracellular space [1-17].”
MethodSelf-citationSchelbert, E. B., Testa, S. M., Meier, C. G., Ceyrolles, W. J., Levenson, J. E., Blair, A. J., Kellman, P., Jones, B. L., Ludwig, D. R., Schwartzman, D., et al. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-16 · Cited by 242
Self-citationJerosch-Herold, M., Sheridan, D. C., Kushner, J. D., Nauman, D., Burgess, D., Dutton, D., Alharethi, R., Li, D., & Hershberger, R. E. (2008) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00429.2008 · Cited by 203 · cited 3×
“Direct measurement of extracellular volume (ECV) was initially developed for quantifying the myocardial extracellular fractional distribution volume [1] and has been proposed as a means for detection and quantification of diffuse myocardial fibrosis [2-6,15-17].”
BackgroundMethodIntegrating a Robust Option into a Multiple Regression Computing Environment
Dumouchel, W., & O’brien, F. (1991) · The IMA Volumes in Mathematics and its Applications · doi:10.1007/978-1-4613-9154-8_3 · Cited by 184 · cited 2×
“Robust fitting [26,27] uses iterative reweighting to improve the fit in the presence of outliers.”
MethodAlper, J. S., & Gelb, R. I. (1990) · The Journal of Physical Chemistry · doi:10.1021/j100374a068 · Cited by 154 · cited 1×
“The desired covariance matrix C of the estimated parameters (A, B, T1) may be approximated as [25]:”
Xue, H., Greiser, A., Zuehlsdorff, S., Jolly, M., Guehring, J., Arai, A. E., & Kellman, P. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24385 · Cited by 118 · cited 4×
“Images were reconstructed using a phase sensitive method which incorporates non-rigid correction of respiratory motion [22].”
MethodSelf-citationNovel Imaging Techniques for Diffuse Myocardial Fibrosis
Sado, D. M., Flett, A. S., & Moon, J. (2011) · Future Cardiology · doi:10.2217/fca.11.45 · Cited by 69 · cited 2×
“Direct measurement of extracellular volume (ECV) was initially developed for quantifying the myocardial extracellular fractional distribution volume [1] and has been proposed as a means for detection and quantification of diffuse myocardial fibrosis [2-6,15-17].”
MethodFernandes, J. L., Storey, P., da Silva, J. A., de Figueiredo, G. S., Kalaf, J. M., & Coelho, O. R. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-6 · Cited by 33
Knesewitsch, T., Meierhofer, C., Rieger, H., Rößler, J., Frank, M., Martinoff, S. A., Hess, J., Stern, H. C., & Fratz, S. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-3 · Cited by 18
Cited by
Messroghli, D. R., Moon, J. C., Ferreira, V. M., Grosse-Wortmann, L., He, T., Kellman, P., Mascherbauer, J., Nezafat, R., Salerno, M., Schelbert, E. B., et al. (2016) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-017-0389-8 · Cited by 1,727
Self-citationMoon, J. C., Messroghli, D. R., Kellman, P., Piechnik, S. K., Robson, M. D., Ugander, M., Gatehouse, P. D., Arai, A. E., Friedrich, M. G., Neubauer, S., et al. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-92 · Cited by 1,136
Self-citationCardiac T1 Mapping and Extracellular Volume (ECV) in clinical practice: a comprehensive review
Haaf, P., Garg, P., Messroghli, D. R., Broadbent, D. A., Greenwood, J. P., & Plein, S. (2016) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-016-0308-4 · Cited by 959
T1-mapping in the heart: accuracy and precision
Kellman, P., & Hansen, M. S. (2014) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-16-2 · Cited by 764
Self-citationT1-Mapping and Outcome in Nonischemic Cardiomyopathy
Puntmann, V. O., Carr-White, G., Jabbour, A., Yu, C.-Y., Gebker, R., Kelle, S., Hinojar, R., Doltra, A., Varma, N., Child, N., et al. (2016) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2015.12.001 · Cited by 478
Metadata
- Authors
- Kellman, P., Arai, A. E., & Xue, H.
- Venue
- Journal of Cardiovascular Magnetic Resonance
- Publisher
- Elsevier BV
- Published
- 2013-01
- Volume
- 15
- Issue
- 1
- Pages
- 56
- ISSN
- 1097-6647 (ISSN-L)
- OpenAlex
- W2151740809
- Cited by
- 177
- References
- 27
- FWCI
- 13.31
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.