Abstract
BACKGROUND: Motivation is an important factor in rehabilitation and frequently used as a determinant of rehabilitation outcome. Several factors can influence patient motivation and so improve exercise adherence. This paper presents the design of two robot devices for use in the rehabilitation of upper limb movements, that can motivate patients during the execution of the assigned motor tasks by enhancing the gaming aspects of rehabilitation. In addition, a regular review of the obtained performance can reinforce in patients' minds the importance of exercising and encourage them to continue, so improving their motivation and consequently adherence to the program. In view of this, we also developed an evaluation metric that could characterize the rate of improvement and quantify the changes in the obtained performance. METHODS: Two groups (G1, n = 8 and G2, n = 12) of patients with chronic stroke were enrolled in a 3-week rehabilitation program including standard physical therapy (45 min. daily) plus treatment by means of robot devices (40 min., twice daily) respectively for wrist (G1) and elbow-shoulder movements (G2). Both groups were evaluated by means of standard clinical assessment scales and the new robot measured evaluation metric. Patients' motivation was assessed in 9/12 G2 patients by means of the Intrinsic Motivation Inventory (IMI) questionnaire. RESULTS: Both groups reduced their motor deficit and showed a significant improvement in clinical scales and the robot measured parameters. The IMI assessed in G2 patients showed high scores for interest, usefulness and importance subscales and low values for tension and pain subscales. CONCLUSION: Thanks to the design features of the two robot devices the therapist could easily adapt training to the individual by selecting different difficulty levels of the motor task tailored to each patient's disability. The gaming aspects incorporated in the two rehabilitation robots helped maintain patients' interest high during execution of the assigned tasks by providing feedback on performance. The evaluation metric gave a precise measure of patients' performance and thus provides a tool to help therapists promote patient motivation and hence adherence to the training program.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
The post-stroke hemiplegic patient. 1. a method for evaluation of physical performance
Fugl-Meyer, A., Jääskö, L., Leyman, I., Olsson, S., & Steglind, S. (1975) · Journal of Rehabilitation Medicine · doi:10.2340/1650197771331 · Cited by 5,564
Control and information in the intrapersonal sphere: An extension of cognitive evaluation theory.
Ryan, R. M. (1982) · Journal of Personality and Social Psychology · doi:10.1037/0022-3514.43.3.450 · Cited by 2,721
McAuley, E., Duncan, T., & Tammen, V. V. (1989) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.1989.10607413 · Cited by 2,694
Facilitating Internalization: The Self‐Determination Theory Perspective
Deci, E. L., Eghrari, H., Patrick, B. C., & Leone, D. R. (1994) · Journal of Personality · doi:10.1111/j.1467-6494.1994.tb00797.x · Cited by 2,627
Robot-aided neurorehabilitation
Krebs, H. I., Hogan, N., Aisen, M. L., & Volpe, B. T. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.662623 · Cited by 1,425
Lum, P. S., Burgar, C. G., Shor, P. C., Majmundar, M., & Van der Loos, M. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.33101 · Cited by 1,159
Prange, G. B., Jannink, M. J. A., Groothuis-Oudshoorn, C. G. M., Hermens, H. J., & IJzerman, M. J. (2006) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2005.04.0076 · Cited by 917
Development of robots for rehabilitation therapy: the Palo Alto VA/Stanford experience.
Burgar, C. G., Lum, P. S., Shor, P. C., & der Loos, H. F. M. V. (2000) · PubMed · Cited by 800
Movement Smoothness Changes during Stroke Recovery
Rohrer, B., Fasoli, S., Krebs, H. I., Hughes, R., Volpe, B., Frontera, W. R., Stein, J., & Hogan, N. (2002) · The Journal of Neuroscience · doi:10.1523/jneurosci.22-18-08297.2002 · Cited by 767
Facilitating Treatment Adherence
Meichenbaum, D., & Turk, D. C. (1987) · Springer eBooks · doi:10.1007/978-1-4684-5359-1 · Cited by 691
A novel approach to stroke rehabilitation: Robot-aided sensorimotor stimulation
Volpe, B. T., Krebs, H. I., Hogan, N., Edelstein, L., Diels, C., & Aisen, M. (2000) · Neurology · doi:10.1212/wnl.54.10.1938 · Cited by 582
Facilitating treatment adherence: A practitioner's guidebook
(1989) · Journal of Pain and Symptom Management · doi:10.1016/0885-3924(89)90017-1 · Cited by 529
Plant, R. W., & Ryan, R. M. (1985) · Journal of Personality · doi:10.1111/j.1467-6494.1985.tb00375.x · Cited by 501
Hesse, S., Schulte-Tigges, G., Konrad, M., Bardeleben, A., & Werner, C. (2003) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(02)04954-7 · Cited by 489
Ego-involved persistence: When free-choice behavior is not intrinsically motivated
Ryan, R. M., Koestner, R., & Deci, E. L. (1991) · Motivation and Emotion · doi:10.1007/bf00995170 · Cited by 459
Qualitative analysis of stroke patients' motivation for rehabilitation
Maclean, N. (2000) · BMJ · doi:10.1136/bmj.321.7268.1051 · Cited by 458
Campbell, R., Evans, M., Tucker, M., Quilty, B., Dieppe, P., & Donovan, J. L. (2001) · Journal of Epidemiology and Community Health · doi:10.1136/jech.55.2.132 · Cited by 414
Robotic techniques for upper limb evaluation and rehabilitation of stroke patients
Colombo, R., Pisano, F., Micera, S., Mazzone, A., Delconte, C., Carrozza, M. C., Dario, P., & Minuco, G. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.848352 · Cited by 399
Self-citationUpper Limb Robot Mediated Stroke Therapy—GENTLE/s Approach
Loureiro, R., Amirabdollahian, F., Topping, M., Driessen, B., & Harwin, W. (2003) · Autonomous Robots · doi:10.1023/a:1024436732030 · Cited by 388
Patient Adherence to Prescribed Therapies
Becker, M. H. (1985) · Medical Care · doi:10.1097/00005650-198505000-00014 · Cited by 339
The Concept of Patient Motivation: A Qualitative Analysis of Stroke Professionals’ Attitudes
Maclean, N., Pound, P., Wolfe, C., & Rudd, A. (2002) · Stroke · doi:10.1161/hs0202.102367 · Cited by 306
Reliability of measurement of muscle tone and muscle power in stroke patients
Gregson, J. (2000) · Age and Ageing · doi:10.1093/ageing/29.3.223 · Cited by 300
Friedrich, M., Gittler, G., Halberstadt, Y., Cermak, T., & Heiller, I. (1998) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(98)90059-4 · Cited by 292
Trajectory formation and handwriting: A computational model
Morasso, P., & Mussa Ivaldi, F. A. (1982) · Biological Cybernetics · doi:10.1007/bf00335240 · Cited by 289
Robot-Assisted Adaptive Training: Custom Force Fields for Teaching Movement Patterns
Patton, J. L., & Mussa-Ivaldi, F. A. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.821035 · Cited by 266
Robotic therapy for chronic motor impairments after stroke: follow-up results
Fasoli, S. E., Krebs, H. I., Stein, J., Frontera, W. R., Hughes, R., & Hogan, N. (2004) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2003.11.028 · Cited by 239
Compliance and exercise in primary and secondary prevention of coronary heart disease: A review
Oldridge, N. B. (1982) · Preventive Medicine · doi:10.1016/0091-7435(82)90005-6 · Cited by 219
Chen, C.-Y., Neufeld, P. S., Feely, C. A., & Skinner, C. S. (1999) · The American Journal of Occupational Therapy · doi:10.5014/ajot.53.2.171 · Cited by 117
Hamrin, E. K. F., & Lindmark, B. (1988) · Scandinavian Journal of Caring Sciences · doi:10.1111/j.1471-6712.1988.tb00357.x · Cited by 100
A Simple Robotic System for Neurorehabilitation
Micera, S., Carrozza, M., Guglielmelli, E., Cappiello, G., Zaccone, F., Freschi, C., Colombo, R., Mazzone, A., Delconte, C., Pisano, F., et al. (2005) · Auton. Robots · doi:10.1007/s10514-005-4749-0 · Cited by 84
Self-citationAssessment of Active and Passive Restraint During Guided Reaching After Chronic Brain Injury
Reinkensmeyer, D. J., Schmit, B. D., & Rymer, W. Z. (1999) · Annals of Biomedical Engineering · doi:10.1114/1.233 · Cited by 72
Development of a robotic device for facilitating learning by children who have severe disabilities
Cook, A., Meng, M. Q.-H., Gu, J. J., & Howery, K. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.802877 · Cited by 58
Motor Learning Concepts Applied to Activity-Based Intervention With Adults With Hemiplegia
Sabari, J. S. (1991) · American Journal of Occupational Therapy · doi:10.5014/ajot.45.6.523 · Cited by 51
Collaborative Tele-rehabilitation: A Strategy for Increasing Engagement
Loureiro, R. C. V., Johnson, M. J., & Harwin, W. (2006) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2006.1639198 · Cited by 26
Cited by
A survey on robotic devices for upper limb rehabilitation
Maciejasz, P., Eschweiler, J., Gerlach-Hahn, K., Jansen-Troy, A., & Leonhardt, S. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-3 · Cited by 1,210
Recent development of mechanisms and control strategies for robot-assisted lower limb rehabilitation
Meng, W., Liu, Q., Zhou, Z., Ai, Q., Sheng, B., & Xie, S. (. (2015) · Mechatronics · doi:10.1016/j.mechatronics.2015.04.005 · Cited by 464
Basteris, A., Nijenhuis, S. M., Stienen, A. H., Buurke, J. H., Prange, G. B., & Amirabdollahian, F. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-111 · Cited by 408
Towards customizable games for stroke rehabilitation
Alankus, G., Lazar, A., May, M., & Kelleher, C. (2010) · Proceedings of the SIGCHI Conference on Human Factors in Computing Systems · doi:10.1145/1753326.1753649 · Cited by 382
Advances in upper limb stroke rehabilitation: a technology push
Loureiro, R. C. V., Harwin, W. S., Nagai, K., & Johnson, M. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0797-0 · Cited by 252
Metadata
- Authors
- Colombo, R., Pisano, F., Mazzone, A., Delconte, C., Micera, S., Carrozza, M. C., Dario, P., & Minuco, G.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2007-02-19
- Volume
- 4
- Issue
- 1
- Pages
- 3-3
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W1807025324
- Cited by
- 385
- References
- 35
- FWCI
- 8.96
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.