The role of feed-forward and feedback processes for closed-loop prosthesis control
Open accessThe DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
BACKGROUND: It is widely believed that both feed-forward and feed-back mechanisms are required for successful object manipulation. Open-loop upper-limb prosthesis wearers receive no tactile feedback, which may be the cause of their limited dexterity and compromised grip force control. In this paper we ask whether observed prosthesis control impairments are due to lack of feedback or due to inadequate feed-forward control. METHODS: Healthy subjects were fitted with a closed-loop robotic hand and instructed to grasp and lift objects of different weights as we recorded trajectories and force profiles. We conducted three experiments under different feed-forward and feed-back configurations to elucidate the role of tactile feedback (i) in ideal conditions, (ii) under sensory deprivation, and (iii) under feed-forward uncertainty. RESULTS: (i) We found that subjects formed economical grasps in ideal conditions. (ii) To our surprise, this ability was preserved even when visual and tactile feedback were removed. (iii) When we introduced uncertainty into the hand controller performance degraded significantly in the absence of either visual or tactile feedback. Greatest performance was achieved when both sources of feedback were present. CONCLUSIONS: We have introduced a novel method to understand the cognitive processes underlying grasping and lifting. We have shown quantitatively that tactile feedback can significantly improve performance in the presence of feed-forward uncertainty. However, our results indicate that feed-forward and feed-back mechanisms serve complementary roles, suggesting that to improve on the state-of-the-art in prosthetic hands we must develop prostheses that empower users to correct for the inevitable uncertainty in their feed-forward control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2005) · Choice Reviews Online · doi:10.5860/choice.43-0626 · Cited by 4,674
Johansson, R. S., & Westling, G. (1984) · Experimental Brain Research · doi:10.1007/bf00237997 · Cited by 1,703 · cited 2×
“Healthy individuals exhibit stereotypical and repeatable grasping profiles [22,25] and the term ‘economical grasp’ describes this ability to minimise grip force while avoiding slip.”
BackgroundFactors influencing the force control during precision grip
Westling, G., & Johansson, R. S. (1984) · Experimental Brain Research · doi:10.1007/bf00238156 · Cited by 1,027 · cited 1×
“Healthy individuals exhibit stereotypical and repeatable grasping profiles [22,25] and the term ‘economical grasp’ describes this ability to minimise grip force while avoiding slip.”
BackgroundElectrotactile and vibrotactile displays for sensory substitution systems
Kaczmarek, K. A., Webster, J. G., Bach-y-Rita, P., & Tompkins, W. J. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68204 · Cited by 827 · cited 1×
“Direct pressure-feedback devices [27] may offer a more natural sensation, and electrotactile feedback might provide greater spatial resolution [28] at the expense of safety.”
BackgroundFlanagan, J. R., & Wing, A. M. (1997) · The Journal of Neuroscience · doi:10.1523/jneurosci.17-04-01519.1997 · Cited by 678 · cited 1×
“The difference between feedforward and feedback processes is of fundamental importance to our understanding of human sensorimotor behaviour [19], and likewise should be considered crucial in designing a prosthesis to improve the quality of life for amputees.”
BackgroundKuiken, T. A., Dumanian, G. A., Lipschutz, R. D., Miller, L. A., & Stubblefield, K. A. (2004) · Prosthetics & Orthotics International · doi:10.3109/03093640409167756 · Cited by 583 · cited 1×
“In the future we may see prosthetic hands that integrate directly with the amputee’s nervous system, utilising state-of-the-art sensor technology [4,5] and relying on pioneering medical procedures [6-8].”
BackgroundDirect neural sensory feedback and control of a prosthetic arm
Dhillon, G. S., & Horch, K. W. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.856072 · Cited by 573 · cited 1×
“In the future we may see prosthetic hands that integrate directly with the amputee’s nervous system, utilising state-of-the-art sensor technology [4,5] and relying on pioneering medical procedures [6-8].”
BackgroundComputational principles of sensorimotor control that minimize uncertainty and variability
Bays, P. M., & Wolpert, D. M. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2006.120121 · Cited by 359 · cited 2×
“Every motor action is undertaken in the presence of uncertainty [32], resulting in some degree of temporal error.”
BackgroundResultDesign of a cybernetic hand for perception and action
Carrozza, M. C., Cappiello, G., Micera, S., Edin, B. B., Beccai, L., & Cipriani, C. (2006) · Biological Cybernetics · doi:10.1007/s00422-006-0124-2 · Cited by 341 · cited 1×
“Nevertheless, state-of-the-art upper limb prostheses are still open-loop devices with limited degrees of control, described as “clumsy” [9] and requiring considerable mental effort [10].”
BackgroundRobotic touch shifts perception of embodiment to a prosthesis in targeted reinnervation amputees
Marasco, P. D., Kim, K., Colgate, J. E., Peshkin, M. A., & Kuiken, T. A. (2011) · Brain · doi:10.1093/brain/awq361 · Cited by 335 · cited 2×
“Vivid sensations of embodiment and prosthesis ownership can only be achieved through physiologically appropriate cutaneous feedback [15].”
BackgroundAugurelle, A.-S., Smith, A. M., Lejeune, T., & Thonnard, J.-L. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00249.2002 · Cited by 330
Decoding a New Neural–Machine Interface for Control of Artificial Limbs
Zhou, P., Lowery, M. M., Englehart, K. B., Huang, H., Li, G., Hargrove, L., Dewald, J. P. A., & Kuiken, T. A. (2007) · Journal of Neurophysiology · doi:10.1152/jn.00178.2007 · Cited by 215 · cited 1×
“Nevertheless, state-of-the-art upper limb prostheses are still open-loop devices with limited degrees of control, described as “clumsy” [9] and requiring considerable mental effort [10].”
BackgroundWolpert, D. M., & Ghahramani, Z. (2004) · UCL Discovery (University College London) · Cited by 196
Duchêne, J., & Goubel, F. (1993) · PubMed · Cited by 178
Vibrotactile Feedback for Brain-Computer Interface Operation
Cincotti, F., Kauhanen, L., Aloise, F., Palomäki, T., Caporusso, N., Jylänki, P., Mattia, D., Babiloni, F., Vanacker, G., Nuttin, M., et al. (2007) · Computational Intelligence and Neuroscience · doi:10.1155/2007/48937 · Cited by 160
Patterson, P. E., & Katz, J. A. (1992) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.1992.01.0001 · Cited by 147 · cited 1×
“Direct pressure-feedback devices [27] may offer a more natural sensation, and electrotactile feedback might provide greater spatial resolution [28] at the expense of safety.”
BackgroundCognitive vision system for control of dexterous prosthetic hands: Experimental evaluation
Došen, S., Cipriani, C., Kostić, M., Controzzi, M., Carrozza, M. C., & Popović, D. B. (2010) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-7-42 · Cited by 145
Control of a Six Degree of Freedom Prosthetic Arm After Targeted Muscle Reinnervation Surgery
Miller, L. A., Lipschutz, R. D., Stubblefield, K. A., Lock, B. A., Huang, H., Williams, T. W., Weir, R. F., & Kuiken, T. A. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2008.05.016 · Cited by 119 · cited 1×
“In the future we may see prosthetic hands that integrate directly with the amputee’s nervous system, utilising state-of-the-art sensor technology [4,5] and relying on pioneering medical procedures [6-8].”
BackgroundCholewiak, R. W., & Collins, A. A. (2000) · Perception & Psychophysics · doi:10.3758/bf03212124 · Cited by 116 · cited 1×
“For these practical reasons we developed a spatially-encoded vibrotactile feedback interface (similar to [30]).”
MethodVibrotactile feedback systems: Current trends in rehabilitation, sports and information display
Alahakone, A. U., & Senanayake, S. M. N. A. (2009) · 2009 IEEE/ASME International Conference on Advanced Intelligent Mechatronics · doi:10.1109/aim.2009.5229741 · Cited by 111 · cited 1×
“However, vibrotactile feedback systems are given credit for their low cost, size and weight and the simplicity and flexibility with which they can be used in sensory substitution applications [29].”
BackgroundSensory-feedback system compatible with myoelectric control
Scott, R. N., Brittain, R. H., Caldwell, R. R., Cameron, A. B., & Dunfield, V. A. (1980) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442481 · Cited by 104
Bio-inspired sensorization of a biomechatronic robot hand for the grasp-and-lift task
Edin, B. B., Ascari, L., Beccai, L., Roccella, S., Cabibihan, J., & Carrozza, M. C. (2008) · Brain Research Bulletin · doi:10.1016/j.brainresbull.2008.01.017 · Cited by 102
A myoelectrically-controlled prosthesis with sensory feedback
Shannon, G. F. (1979) · Medical & Biological Engineering & Computing · doi:10.1007/bf02440956 · Cited by 92 · cited 1×
“Historically, feedback has been added to increase patient confidence [1] and to improve object grasping and lifting [2,3].”
BackgroundThe i-LIMB Hand and the DMC Plus Hand Compared: A Case Report
Van Der Niet, O., Reinders-Messelink, H. A., Bongers, R. M., Bouwsema, H., & Van Der Sluis, C. K. (2010) · Prosthetics & Orthotics International · doi:10.3109/03093641003767207 · Cited by 87
Hermsdörfer, J., Elias, Z., Cole, J. D., Quaney, B. M., & Nowak, D. A. (2007) · Neurorehabilitation and neural repair · doi:10.1177/1545968307311103 · Cited by 81 · cited 5×
“It has been previously shown in healthy humans that cutaneous feedback enables maintenance of the anticipatory components of grasping [18], but our results suggest that, under the idealised control conditions, force feedback was not necessary for this purpose.”
BackgroundResultInfluentialHermsdörfer, J., Hagl, E., & Nowak, D. A. (2004) · Human Movement Science · doi:10.1016/j.humov.2004.10.005 · Cited by 70 · cited 3×
“Feedforward anticipatory grip forces precede load changes due to acceleration, a phenomenon unimpaired by digital anaesthesia [20] and long-term peripheral sensory neuropathy [21].”
BackgroundResultGrip Force Control in Individuals With Multiple Sclerosis
Iyengar, V., dos Santos, M. J., Ko, M., & Aruin, A. S. (2009) · Neurorehabilitation and neural repair · doi:10.1177/1545968309338194 · Cited by 62 · cited 1×
“For example, Multiple Sclerosis patients significantly overgrip objects [11], but when sufferers receive vibratory feedback of their grip force (displaced to their lessaffected hand) these forces reduce [12].”
BackgroundA Novel Concept for a Prosthetic Hand With a Bidirectional Interface: A Feasibility Study
Cipriani, C., Antfolk, C., Balkenius, C., Rosen, B., Lundborg, G., Carrozza, M. C., & Sebelius, F. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2031242 · Cited by 48 · cited 1×
“In a similar way, prosthesis fingertip forces have been transferred to the stump [13] or even the toes of amputees [14] to create appropriate and useful sensations.”
BackgroundImproved Grasp Force Sensitivity for Prosthetic Hands Through Force-Derivative Feedback
Engeberg, E. D., & Meek, S. G. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.912675 · Cited by 47
Humans Can Integrate Force Feedback to Toes in Their Sensorimotor Control of a Robotic Hand
Panarese, A., Edin, B. B., Vecchi, F., Carrozza, M. C., & Johansson, R. S. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2021689 · Cited by 47 · cited 1×
“In a similar way, prosthesis fingertip forces have been transferred to the stump [13] or even the toes of amputees [14] to create appropriate and useful sensations.”
BackgroundUsing Haptic Feedback to Improve Grasp Force Control in Multiple Sclerosis Patients
Jiang, L., Cutkosky, M. R., Ruutiainen, J., & Raisamo, R. (2009) · IEEE Transactions on Robotics · doi:10.1109/tro.2009.2019789 · Cited by 38 · cited 1×
“For example, Multiple Sclerosis patients significantly overgrip objects [11], but when sufferers receive vibratory feedback of their grip force (displaced to their lessaffected hand) these forces reduce [12].”
BackgroundQuantifying Prosthesis Control Improvements Using a Vibrotactile Representation of Grip Force
Chatterjee, A., Chaubey, P., Martin, J. B., & Thakor, N. V. (2008) · IEEE Region 10 Conference (TENCON) · doi:10.1109/tpsd.2008.4562727 · Cited by 37 · cited 2×
“A study to quantify the benefits of artificial feedback for force control also found no significant difference between feedback and no-feedback groups [26].”
BackgroundCognitive feedback for use with FES upper extremity neuroprostheses
Riso, R. R., Ignagni, A. R., & Keith, M. W. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68206 · Cited by 36 · cited 1×
“Historically, feedback has been added to increase patient confidence [1] and to improve object grasping and lifting [2,3].”
BackgroundEffectiveness of supplemental grasp-force feedback in the presence of vision
Zafar, M., & Doren, C. L. V. (2000) · Medical & Biological Engineering & Computing · doi:10.1007/bf02347046 · Cited by 29
Bio-inspired grasp control in a robotic hand with massive sensorial input
Ascari, L., Bertocchi, U., Corradi, P., Laschi, C., & Dario, P. (2008) · Biological Cybernetics · doi:10.1007/s00422-008-0279-0 · Cited by 28 · cited 1×
“In the future we may see prosthetic hands that integrate directly with the amputee’s nervous system, utilising state-of-the-art sensor technology [4,5] and relying on pioneering medical procedures [6-8].”
BackgroundEvaluation of command algorithms for control of upper-extremity neural prostheses
Humbert, S., Snyder, S. A., & Grill, W. M. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.1031977 · Cited by 15 · cited 1×
“see [24]).”
Surface EMG classification during dynamic contractions for multifunction transradial prostheses
Lorrain, T., Jiang, N., & Farina, D. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626587 · Cited by 10 · cited 1×
“Since EMG signals used to initiate and control prosthesis movement fluctuate as a function of sweat, movement, muscle fatigue and skin-conductivity [33] the most reliable EMG classifiers require 250-300 ms of sampling time before accurate classification can be made [34].”
Background
Research works printed but not linked: 1
- 10.1080/17470210801985235 · DOI
Cited by
Sensory feedback in upper limb prosthetics
Antfolk, C., D’Alonzo, M., Rosén, B., Lundborg, G., Sebelius, F., & Cipriani, C. (2013) · Expert Review of Medical Devices · doi:10.1586/erd.12.68 · Cited by 466
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Restoration of sensory information via bionic hands
Bensmaia, S. J., Tyler, D. J., & Micera, S. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00630-8 · Cited by 257
Schiefer, M., Tan, D., Sidek, S. M., & Tyler, D. J. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/1/016001 · Cited by 255
“In a different study, vibrotactile feedback in the absence of visual and auditory feedback did not significantly affect performance during grasp and lift tasks [41].”
BackgroundHaptic wearables as sensory replacement, sensory augmentation and trainer – a review
Shull, P. B., & Damian, D. D. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0055-z · Cited by 245
“Haptics for total impairment aims to restore missing tactile or proprioceptive information vital to prosthetic grasp to prolong sustained prosthesis use [28–31].”
Background
Metadata
- Authors
- Saunders, I., & Vijayakumar, S.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2011
- Volume
- 8
- Issue
- 1
- Pages
- 60
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W2115327539
- Cited by
- 193
- References
- 37
- FWCI
- 4.97
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.