The role of feed-forward and feedback processes for closed-loop prosthesis control
Open accessThe DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
BACKGROUND: It is widely believed that both feed-forward and feed-back mechanisms are required for successful object manipulation. Open-loop upper-limb prosthesis wearers receive no tactile feedback, which may be the cause of their limited dexterity and compromised grip force control. In this paper we ask whether observed prosthesis control impairments are due to lack of feedback or due to inadequate feed-forward control. METHODS: Healthy subjects were fitted with a closed-loop robotic hand and instructed to grasp and lift objects of different weights as we recorded trajectories and force profiles. We conducted three experiments under different feed-forward and feed-back configurations to elucidate the role of tactile feedback (i) in ideal conditions, (ii) under sensory deprivation, and (iii) under feed-forward uncertainty. RESULTS: (i) We found that subjects formed economical grasps in ideal conditions. (ii) To our surprise, this ability was preserved even when visual and tactile feedback were removed. (iii) When we introduced uncertainty into the hand controller performance degraded significantly in the absence of either visual or tactile feedback. Greatest performance was achieved when both sources of feedback were present. CONCLUSIONS: We have introduced a novel method to understand the cognitive processes underlying grasping and lifting. We have shown quantitatively that tactile feedback can significantly improve performance in the presence of feed-forward uncertainty. However, our results indicate that feed-forward and feed-back mechanisms serve complementary roles, suggesting that to improve on the state-of-the-art in prosthetic hands we must develop prostheses that empower users to correct for the inevitable uncertainty in their feed-forward control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2005) · Choice Reviews Online · doi:10.5860/choice.43-0626 · Cited by 4,674
Johansson, R. S., & Westling, G. (1984) · Experimental Brain Research · doi:10.1007/bf00237997 · Cited by 1,703 · cited 2×
“Healthy individuals exhibit stereotypical and repeatable grasping profiles [22,25] and the term ‘economical grasp’ describes this ability to minimise grip force while avoiding slip.”
BackgroundFactors influencing the force control during precision grip
Westling, G., & Johansson, R. S. (1984) · Experimental Brain Research · doi:10.1007/bf00238156 · Cited by 1,027 · cited 1×
“Healthy individuals exhibit stereotypical and repeatable grasping profiles [22,25] and the term ‘economical grasp’ describes this ability to minimise grip force while avoiding slip.”
BackgroundElectrotactile and vibrotactile displays for sensory substitution systems
Kaczmarek, K. A., Webster, J. G., Bach-y-Rita, P., & Tompkins, W. J. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68204 · Cited by 827 · cited 1×
“Direct pressure-feedback devices [27] may offer a more natural sensation, and electrotactile feedback might provide greater spatial resolution [28] at the expense of safety.”
BackgroundFlanagan, J. R., & Wing, A. M. (1997) · The Journal of Neuroscience · doi:10.1523/jneurosci.17-04-01519.1997 · Cited by 678 · cited 1×
“The difference between feedforward and feedback processes is of fundamental importance to our understanding of human sensorimotor behaviour [19], and likewise should be considered crucial in designing a prosthesis to improve the quality of life for amputees.”
BackgroundKuiken, T. A., Dumanian, G. A., Lipschutz, R. D., Miller, L. A., & Stubblefield, K. A. (2004) · Prosthetics & Orthotics International · doi:10.3109/03093640409167756 · Cited by 583 · cited 1×
“In the future we may see prosthetic hands that integrate directly with the amputee’s nervous system, utilising state-of-the-art sensor technology [4,5] and relying on pioneering medical procedures [6-8].”
BackgroundDirect neural sensory feedback and control of a prosthetic arm
Dhillon, G. S., & Horch, K. W. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.856072 · Cited by 573 · cited 1×
“In the future we may see prosthetic hands that integrate directly with the amputee’s nervous system, utilising state-of-the-art sensor technology [4,5] and relying on pioneering medical procedures [6-8].”
BackgroundComputational principles of sensorimotor control that minimize uncertainty and variability
Bays, P. M., & Wolpert, D. M. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2006.120121 · Cited by 359 · cited 2×
“Every motor action is undertaken in the presence of uncertainty [32], resulting in some degree of temporal error.”
BackgroundResultDesign of a cybernetic hand for perception and action
Carrozza, M. C., Cappiello, G., Micera, S., Edin, B. B., Beccai, L., & Cipriani, C. (2006) · Biological Cybernetics · doi:10.1007/s00422-006-0124-2 · Cited by 341 · cited 1×
“Nevertheless, state-of-the-art upper limb prostheses are still open-loop devices with limited degrees of control, described as “clumsy” [9] and requiring considerable mental effort [10].”
BackgroundRobotic touch shifts perception of embodiment to a prosthesis in targeted reinnervation amputees
Marasco, P. D., Kim, K., Colgate, J. E., Peshkin, M. A., & Kuiken, T. A. (2011) · Brain · doi:10.1093/brain/awq361 · Cited by 335 · cited 2×
“Vivid sensations of embodiment and prosthesis ownership can only be achieved through physiologically appropriate cutaneous feedback [15].”
Background
Research works printed but not linked: 1
- 10.1080/17470210801985235 · DOI
Cited by
Sensory feedback in upper limb prosthetics
Antfolk, C., D’Alonzo, M., Rosén, B., Lundborg, G., Sebelius, F., & Cipriani, C. (2013) · Expert Review of Medical Devices · doi:10.1586/erd.12.68 · Cited by 466
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Restoration of sensory information via bionic hands
Bensmaia, S. J., Tyler, D. J., & Micera, S. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00630-8 · Cited by 257
Schiefer, M., Tan, D., Sidek, S. M., & Tyler, D. J. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/1/016001 · Cited by 255
“In a different study, vibrotactile feedback in the absence of visual and auditory feedback did not significantly affect performance during grasp and lift tasks [41].”
BackgroundHaptic wearables as sensory replacement, sensory augmentation and trainer – a review
Shull, P. B., & Damian, D. D. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0055-z · Cited by 245
“Haptics for total impairment aims to restore missing tactile or proprioceptive information vital to prosthetic grasp to prolong sustained prosthesis use [28–31].”
BackgroundA Review of Non-Invasive Sensory Feedback Methods for Transradial Prosthetic Hands
Stephens-Fripp, B., Alici, G., & Mutlu, R. (2018) · IEEE Access · doi:10.1109/access.2018.2791583 · Cited by 210
“Using vibration as a source of force feedback has been demonstrated to have improvements over using vision alone as a feedback tool [41], [44], [46], but some literature suggests that this benefit is only visible during inadequate feedforward control [85].”
Clemente, F., D'Alonzo, M., Controzzi, M., Edin, B. B., & Cipriani, C. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2500586 · Cited by 209
Antfolk, C., D'Alonzo, M., Controzzi, M., Lundborg, G., Rosen, B., Sebelius, F., & Cipriani, C. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2217989 · Cited by 194
“Among these, Saunders and Vijayakumar [19] used a multisite vibrotactile array where the grip force of a prosthetic hand”
MethodSelectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review.
Ghafoor, U., Kim, S., & Hong, K.-S. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00059 · Cited by 88
“…of the skin (Wheeler et al., 2010; Motamedi et al., 2017), the improvement in grasping force (Chatterjee et al., 2008; Cipriani et al., 2008, 2014; Saunders and Vijayakumar, 2011; Montagnani et al., 2015; Witteveen et al., 2015), the evoked sense of proprioception by the vibrations of a tendon…”
Mastinu, E., Clemente, F., Sassu, P., Aszmann, O., Brånemark, R., Håkansson, B., Controzzi, M., Cipriani, C., & Ortiz-Catalan, M. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0511-2 · Cited by 87
Multichannel electrotactile feedback for simultaneous and proportional myoelectric control
Patel, G. K., Dosen, S., Castellini, C., & Farina, D. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/5/056015 · Cited by 58
“For example, in [26, 28] an array of vibration motors and concentric electrodes was employed to communicate the grasping force and hand aperture.”
MethodLee, S., & Lee, C. (2018) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2018.05.004 · Cited by 48
Wang, J., Thow, X. Y., Wang, H., Lee, S., Voges, K., Thakor, N. V., Yen, S., & Lee, C. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700987 · Cited by 43
Perovic, M., Stevanovic, M., Jevtic, T., Strbac, M., Bijelic, G., Vucetic, C., Popovic-Maneski, L., & Popovic, D. (2013) · Journal of Automatic Control · doi:10.2298/jac1301013p · Cited by 28
Metadata
- Authors
- Saunders, I., & Vijayakumar, S.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2011
- Volume
- 8
- Issue
- 1
- Pages
- 60
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W2115327539
- Cited by
- 193
- References
- 37
- FWCI
- 4.97
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.