Toward attenuating the impact of arm positions on electromyography pattern-recognition based motion classification in transradial amputees
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Background: Electromyography (EMG) pattern-recognition based control strategies for multifunctional myoelectric prosthesis systems have been studied commonly in a controlled laboratory setting. Before these myoelectric prosthesis systems are clinically viable, it will be necessary to assess the effect of some disparities between the ideal laboratory setting and practical use on the control performance. One important obstacle is the impact of arm position variation that causes the changes of EMG pattern when performing identical motions in different arm positions. This study aimed to investigate the impacts of arm position variation on EMG pattern-recognition based motion classification in upper-limb amputees and the solutions for reducing these impacts. Methods: With five unilateral transradial (TR) amputees, the EMG signals and tri-axial accelerometer mechanomyography (ACC-MMG) signals were simultaneously collected from both amputated and intact arms when performing six classes of arm and hand movements in each of five arm positions that were considered in the study. The effect of the arm position changes was estimated in terms of motion classification error and compared between amputated and intact arms. Then the performance of three proposed methods in attenuating the impact of arm positions was evaluated. Results: With EMG signals, the average intra-position and inter-position classification errors across all five arm positions and five subjects were around 7.3% and 29.9% from amputated arms, respectively, about 1.0% and 10% low in comparison with those from intact arms. While ACC-MMG signals could yield a similar intra-position classification error (9.9%) as EMG, they had much higher inter-position classification error with an average value of 81.1% over the arm positions and the subjects. When the EMG data from all five arm positions were involved in the training set, the average classification error reached a value of around 10.8% for amputated arms. Using a two-stage cascade classifier, the average classification error was around 9.0% over all five arm positions. Reducing ACC-MMG channels from 8 to 2 only increased the average position classification error across all five arm positions from 0.7% to 1.0% in amputated arms. Conclusions: The performance of EMG pattern-recognition based method in classifying movements strongly depends on arm positions. This dependency is a little stronger in intact arm than in amputated arm, which suggests that the investigations associated with practical use of a myoelectric prosthesis should use the limb amputees as subjects instead of using able-body subjects. The two-stage cascade classifier mode with ACC-MMG for limb position identification and EMG for limb motion classification may be a promising way to reduce the effect of limb position variation on classification performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149 · cited 2×
“One portion of the acquired EMG data was used to train a classifier and then remaining portion was loaded into the trained classifier for calculating the offline classification accuracy in identifying a number of arm and hand movements [4-18,21-23].”
BackgroundMethodA robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743 · cited 11×
“More complex classifiers such as artificial neural network, hidden Markov model, and fuzzy logic classifiers may be considered, but it has been reported in previous works [8,23] that a LDA classifier would not compromise the accuracy of motion classification.”
BackgroundMethodResultInfluentialTargeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089 · cited 12×
“More complex classifiers such as artificial neural network, hidden Markov model, and fuzzy logic classifiers may be considered, but it has been reported in previous works [8,23] that a LDA classifier would not compromise the accuracy of motion classification.”
BackgroundMethodInfluentialClassification of the myoelectric signal using time-frequency based representations
Englehart, K., Hudgins, B., Parker, P. A., & Stevenson, M. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00066-1 · Cited by 645 · cited 9×
“More complex classifiers such as artificial neural network, hidden Markov model, and fuzzy logic classifiers may be considered, but it has been reported in previous works [8,23] that a LDA classifier would not compromise the accuracy of motion classification.”
BackgroundMethodInfluentialHuang, Y., Englehart, K. B., Hudgins, B., & Chan, A. D. C. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.856295 · Cited by 643 · cited 2×
“One portion of the acquired EMG data was used to train a classifier and then remaining portion was loaded into the trained classifier for calculating the offline classification accuracy in identifying a number of arm and hand movements [4-18,21-23].”
BackgroundMethodA Framework for Hand Gesture Recognition Based on Accelerometer and EMG Sensors
Zhang, X., Chen, X., Li, Y., Lantz, V., Wang, K., & Yang, J. (2011) · IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans · doi:10.1109/tsmca.2011.2116004 · Cited by 618
Study of stability of time-domain features for electromyographic pattern recognition
Tkach, D., Huang, H., & Kuiken, T. A. (2010) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-7-21 · Cited by 582 · cited 9×
“More complex classifiers such as artificial neural network, hidden Markov model, and fuzzy logic classifiers may be considered, but it has been reported in previous works [8,23] that a LDA classifier would not compromise the accuracy of motion classification.”
BackgroundMethodInfluentialA Comparison of Surface and Intramuscular Myoelectric Signal Classification
Hargrove, L. J., Englehart, K., & Hudgins, B. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889192 · Cited by 518 · cited 9×
“More complex classifiers such as artificial neural network, hidden Markov model, and fuzzy logic classifiers may be considered, but it has been reported in previous works [8,23] that a LDA classifier would not compromise the accuracy of motion classification.”
BackgroundMethodInfluentialQuantifying Pattern Recognition—Based Myoelectric Control of Multifunctional Transradial Prostheses
Li, G., Schultz, A. E., & Kuiken, T. A. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039619 · Cited by 443
Self-citationA heuristic fuzzy logic approach to EMG pattern recognition for multifunctional prosthesis control
Ajiboye, A. B., & Weir, R. F. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847357 · Cited by 415 · cited 2×
“One portion of the acquired EMG data was used to train a classifier and then remaining portion was loaded into the trained classifier for calculating the offline classification accuracy in identifying a number of arm and hand movements [4-18,21-23].”
BackgroundMethodResolving the Limb Position Effect in Myoelectric Pattern Recognition
Fougner, A., Scheme, E., Chan, A. D. C., Englehart, K., & Stavdahl, Ø. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2163529 · Cited by 402
Young, A. J., Hargrove, L. J., & Kuiken, T. A. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2159216 · Cited by 287 · cited 10×
“More complex classifiers such as artificial neural network, hidden Markov model, and fuzzy logic classifiers may be considered, but it has been reported in previous works [8,23] that a LDA classifier would not compromise the accuracy of motion classification.”
BackgroundMethodInfluentialProsthetic usage in major upper extremity amputations
Wright, T. W., Hagen, A. D., & Wood, M. B. (1995) · The Journal of Hand Surgery · doi:10.1016/s0363-5023(05)80278-3 · Cited by 266 · cited 1×
“Background Myoelectric signals recorded with electrodes on the skin surface overlying the residual arm muscles have been used in control of motorized upper-limb prostheses for several decades [1-23].”
BackgroundHargrove, L. J., Li, G., Englehart, K. B., & Hudgins, B. S. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2008171 · Cited by 211 · cited 1×
“One portion of the acquired EMG data was used to train a classifier and then remaining portion was loaded into the trained classifier for calculating the offline classification accuracy in identifying a number of arm and hand movements [4-18,21-23].”
MethodSelf-citationMyoelectric control of prostheses.
Parker, P. A., & Scott, R. N. (1986) · PubMed · Cited by 203
EMG pattern recognition based on artificial intelligence techniques
Park, S.-H., & Lee, S.-P. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.736154 · Cited by 197
Lorrain, T., Jiang, N., & Farina, D. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-25 · Cited by 165 · cited 9×
“More complex classifiers such as artificial neural network, hidden Markov model, and fuzzy logic classifiers may be considered, but it has been reported in previous works [8,23] that a LDA classifier would not compromise the accuracy of motion classification.”
BackgroundMethodInfluentialExamining the adverse effects of limb position on pattern recognition based myoelectric control
Scheme, E., Fougner, A., Stavdahl, Ø., Chan, A. D. C., & Englehart, K. (2010) · 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology · doi:10.1109/iembs.2010.5627638 · Cited by 161
Momen, K., Krishnan, S., & Chau, T. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.908376 · Cited by 152 · cited 2×
“One portion of the acquired EMG data was used to train a classifier and then remaining portion was loaded into the trained classifier for calculating the offline classification accuracy in identifying a number of arm and hand movements [4-18,21-23].”
BackgroundMethod(1986) · PubMed · Cited by 137
A Self-Contained, Mechanomyography-Driven Externally Powered Prosthesis
Silva, J. A. M. D. C., Heim, W., & Chau, T. T. (2005) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2005.03.034 · Cited by 128
Sebelius, F., Rosén, B., & Lundborg, G. (2005) · The Journal Of Hand Surgery · doi:10.1016/j.jhsa.2005.01.002 · Cited by 125 · cited 1×
“One portion of the acquired EMG data was used to train a classifier and then remaining portion was loaded into the trained classifier for calculating the offline classification accuracy in identifying a number of arm and hand movements [4-18,21-23].”
MethodSimon, A. M., Hargrove, L. J., Lock, B. A., & Kuiken, T. A. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2155063 · Cited by 120 · cited 10×
“More complex classifiers such as artificial neural network, hidden Markov model, and fuzzy logic classifiers may be considered, but it has been reported in previous works [8,23] that a LDA classifier would not compromise the accuracy of motion classification.”
BackgroundMethodInfluentialA three-state myo-electric control
Dorcas, D. S., & Scott, R. N. (1966) · Medical & Biological Engineering & Computing · doi:10.1007/bf02476154 · Cited by 119
Kang, W.-J., Shiu, J.-R., Cheng, C.-K., Lai, J.-S., Tsao, H.-W., & Kuo, T.-S. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.398638 · Cited by 118
Li, G., Li, Y., Yu, L., & Geng, Y. (2011) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0265-x · Cited by 109 · cited 12×
“More complex classifiers such as artificial neural network, hidden Markov model, and fuzzy logic classifiers may be considered, but it has been reported in previous works [8,23] that a LDA classifier would not compromise the accuracy of motion classification.”
BackgroundMethodResultInfluentialSelf-citation
Cited by
Farina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305111 · Cited by 992
Al-Timemy, A. H., Khushaba, R. N., Bugmann, G., & Escudero, J. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2445634 · Cited by 336
Al-Timemy, A. H., Bugmann, G., Escudero, J., & Outram, N. (2013) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2013.2249590 · Cited by 326
A survey of sensor fusion methods in wearable robotics
Novak, D., & Riener, R. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.012 · Cited by 252
Samuel, O. W., Asogbon, M. G., Geng, Y., Al-Timemy, A. H., Pirbhulal, S., Ji, N., Chen, S., Fang, P., & Li, G. (2019) · IEEE Access · doi:10.1109/access.2019.2891350 · Cited by 185
“And the extracted features includes our proposed time-domain feature set that is invariant to force variation (invTDF), Huggins feature set (TD4), Fourth order autoregressive coefficient (AR4th), and a recently proposed two dimensional TD feature set denoted as NOV [81].”
MethodSelf-citation
Metadata
- Authors
- Geng, Y., Zhou, P., & Li, G.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2012-10-05
- Volume
- 9
- Issue
- 1
- Pages
- 74-74
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W1963745554
- Cited by
- 183
- References
- 26
- FWCI
- 6.28
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.