The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Respiratory variations of inferior vena cava diameter to predict fluid responsiveness in spontaneously breathing patients with acute circulatory failure: need for a cautious use
Open accessAbstract
Introduction: To investigate whether respiratory variation of inferior vena cava diameter (cIVC) predict fluid responsiveness in spontaneously breathing patients with acute circulatory failure (ACF). Methods: Forty patients with ACF and spontaneous breathing were included. Response to fluid challenge was defined as a 15% increase of subaortic velocity time index (VTI) measured by transthoracic echocardiography. Inferior vena cava diameters were recorded by a subcostal view using M Mode. The cIVC was calculated as follows: (Dmax - Dmin/Dmax) × 100 and then receiver operating characteristic (ROC) curves were generated for cIVC, baseline VTI, E wave velocity, E/A and E/Ea ratios. Results: Among 40 included patients, 20 (50%) were responders (R). The causes of ACF were sepsis (n = 24), haemorrhage (n = 11), and dehydration (n = 5). The area under the ROC curve for cIVC was 0.77 (95% CI: 0.60-0.88). The best cutoff value was 40% (Se = 70%, Sp = 80%). The AUC of the ROC curves for baseline E wave velocity, VTI, E/A ratio, E/Ea ratio were 0.83 (95% CI: 0.68-0.93), 0.78 (95% CI: 0.61-0.88), 0.76 (95% CI: 0.59-0.89), 0.58 (95% CI: 0.41-0.75), respectively. The differences between AUC the ROC curves for cIVC and baseline E wave velocity, baseline VTI, baseline E/A ratio, and baseline E/Ea ratio were not statistically different (p = 0.46, p = 0.99, p = 1.00, p = 0.26, respectively). Conclusion: In spontaneously breathing patients with ACF, high cIVC values (>40%) are usually associated with fluid responsiveness while low values (< 40%) do not exclude fluid responsiveness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hanley, J. A., & McNeil, B. J. (1983) · Radiology · doi:10.1148/radiology.148.3.6878708 · Cited by 7,016
Recommendations for the Evaluation of Left Ventricular Diastolic Function by Echocardiography
Nagueh, S. F., Appleton, C. P., Gillebert, T. C., Marino, P. N., Oh, J. K., Smiseth, O. A., Waggoner, A. D., Flachskampf, F. A., Pellikka, P. A., & Evangelista, A. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2008.11.023 · Cited by 4,367
Recommendations for the evaluation of left ventricular diastolic function by echocardiography
Nagueh, S. F., Appleton, C. P., Gillebert, T. C., Marino, P. N., Oh, J. K., Smiseth, O. A., Waggoner, A. D., Flachskampf, F. A., Pellikka, P. A., & Evangelisa, A. (2008) · European Journal of Echocardiography · doi:10.1093/ejechocard/jep007 · Cited by 3,351
MICHARD, F., BOUSSAT, S., CHEMLA, D., ANGUEL, N., MERCAT, A., LECARPENTIER, Y., RICHARD, C., PINSKY, M. R., & TEBOUL, J.-L. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.1.9903035 · Cited by 1,458
Predicting Fluid Responsiveness in ICU Patients
Michard, F., & Teboul, J.-L. (2002) · Chest · doi:10.1378/chest.121.6.2000 · Cited by 1,367
Marik, P. E., Cavallazzi, R., Vasu, T., & Hirani, A. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181a590da · Cited by 1,272
The respiratory variation in inferior vena cava diameter as a guide to fluid therapy
Feissel, M., Michard, F., Faller, J.-P., & Teboul, J.-L. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2233-5 · Cited by 967
Passive leg raising predicts fluid responsiveness in the critically ill*
Monnet, X., Rienzo, M., Osman, D., Anguel, N., Richard, C., Pinsky, M. R., & Teboul, J.-L. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000215453.11735.06 · Cited by 952
Barbier, C., Loubières, Y., Schmit, C., Hayon, J., Ricôme, J.-L., Jardin, F., & Vieillard-Baron, A. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2259-8 · Cited by 940
Mayo, P. H., Beaulieu, Y., Doelken, P., Feller-Kopman, D., Harrod, C., Kaplan, A., Oropello, J., Vieillard-Baron, A., Axler, O., Lichtenstein, D., et al. (2009) · Chest · doi:10.1378/chest.08-2305 · Cited by 736
Lewis, J. F., Kuo, L. C., Nelson, J. G., Limacher, M. C., & Quinones, M. A. (1984) · Circulation · doi:10.1161/01.cir.70.3.425 · Cited by 733
Changes in Arterial Pressure during Mechanical Ventilation
Michard, F. (2005) · Anesthesiology · doi:10.1097/00000542-200508000-00026 · Cited by 713
Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge*
Osman, D., Ridel, C., Ray, P., Monnet, X., Anguel, N., Richard, C., & Teboul, J.-L. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000249851.94101.4f · Cited by 695
Feissel, M., Michard, F., Mangin, I., Ruyer, O., Faller, J.-P., & Teboul, J.-L. (2001) · CHEST · doi:10.1378/chest.119.3.867 · Cited by 612
Statistical Evaluation of a Biomarker
Ray, P., Manach, Y. L., Riou, B., Houle, T. T., & Warner, D. S. (2010) · Anesthesiology · doi:10.1097/aln.0b013e3181d47604 · Cited by 503
Superior vena caval collapsibility as a gauge of volume status in ventilated septic patients
Vieillard-Baron, A., Chergui, K., Rabiller, A., Peyrouset, O., Page, B., Beauchet, A., & Jardin, F. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2361-y · Cited by 476
Dokainish, H., Zoghbi, W. A., Lakkis, N. M., Al-Bakshy, F., Dhir, M., Quinones, M. A., & Nagueh, S. F. (2004) · Circulation · doi:10.1161/01.cir.0000127882.58426.7a · Cited by 465
Reappraisal of the Use of Inferior Vena Cava for Estimating Right Atrial Pressure
Brennan, J. M., Blair, J. E., Goonewardena, S., Ronan, A., Shah, D., Vasaiwala, S., Kirkpatrick, J. N., & Spencer, K. T. (2007) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2007.01.005 · Cited by 459
Vincent, J.-L., & Weil, M. H. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000214677.76535.a5 · Cited by 424
Clinical review: Update on hemodynamic monitoring - a consensus of 16
Vincent, J.-L., Rhodes, A., Perel, A., Martin, G. S., Rocca, G., Vallet, B., Pinsky, M. R., Hofer, C. K., Teboul, J.-L., de Boode, W.-P., et al. (2011) · Critical Care · doi:10.1186/cc10291 · Cited by 419
Lamia, B., Ochagavia, A., Monnet, X., Chemla, D., Richard, C., & Teboul, J.-L. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0646-7 · Cited by 393
Boulain, T., Achard, J.-M., Teboul, J.-L., Richard, C., Perrotin, D., & Ginies, G. (2002) · Chest · doi:10.1378/chest.121.4.1245 · Cited by 351
Muller, L., Toumi, M., Bousquet, P.-J., Riu-Poulenc, B., Louart, G., Candela, D., Zoric, L., Suehs, C., de La Coussaye, J.-E., Molinari, N., et al. (2011) · Anesthesiology · doi:10.1097/aln.0b013e318229a500 · Cited by 343
Self-citationNagdev, A. D., Merchant, R. C., Tirado-Gonzalez, A., Sisson, C. A., & Murphy, M. C. (2010) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2009.04.021 · Cited by 317
Echo–Doppler Demonstration of Acute Cor Pulmonale at the Bedside in the Medical Intensive Care Unit
Vieillard-Baron, A., Prin, S., Chergui, K., Dubourg, O., & Jardin, F. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200202-146cc · Cited by 316
Diagnosis of central hypovolemia by using passive leg raising
Maizel, J., Airapetian, N., Lorne, E., Tribouilloy, C., Massy, Z., & Slama, M. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0642-y · Cited by 297
Sonographic measurement of the inferior vena cava as a marker of blood loss
Lyon, M., Blaivas, M., & Brannam, L. (2005) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2004.01.004 · Cited by 258
Wallace, D. J., Allison, M., & Stone, M. B. (2009) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2009.00627.x · Cited by 179
Soubrier, S., Saulnier, F., Hubert, H., Delour, P., Lenci, H., Onimus, T., Nseir, S., & Durocher, A. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0644-9 · Cited by 129
The effect of breathing manner on inferior vena caval diameter
Kimura, B. J., Dalugdugan, R., Gilcrease, G. W., Phan, J. N., Showalter, B. K., & Wolfson, T. (2011) · European Journal of Echocardiography · doi:10.1093/ejechocard/jeq157 · Cited by 97
Bouhemad, B., Nicolas-Robin, A., Benois, A., Lemaire, S., Goarin, J., & Rouby, J. (2003) · Anesthesiology · doi:10.1097/00000542-200305000-00011 · Cited by 81
Boussuges, A., Blanc, P., MOLENAT, F., Burnet, H., Habib, G., & Sainty, J. (2002) · Critical Care Medicine · doi:10.1097/00003246-200202000-00016 · Cited by 76
Hemodynamic effects of passive leg raising: an echocardiographic study in patients with shock
Caille, V., Jabot, J., Belliard, G., et al. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1067-y · Cited by 67
Esmaeilzadeh, M., Parsaee, M., Peighambari, M. M., Sadeghpour, A., Khamooshi, A. J., Hosseini, S., & Mozaffari, K. (2008) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ejechocard/jen204 · Cited by 65
Müller, L., Louart, G., Bengler, C., Fabbro-Péray, P., Carr, J., Ripart, J., Coussaye, J.-E. D. L., & Lefrant, J. (2008) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31817e6618 · Cited by 56
Self-citationDokainish, H., Nguyen, J., Sengupta, R., Pillai, M., Alam, M., Bobek, J., & Lakkis, N. M. (2010) · Echocardiography · doi:10.1111/j.1540-8175.2010.01177.x · Cited by 24
Bootstrap confidence intervals: when, which, what? A practical guide for medical statisticians
Carpenter (2000) · doi:10.1002/(sici)1097-0258(20000515)19:9<1141::aid-sim479>3.0.co;2-f
Cited by
International Evidence-Based Recommendations for Focused Cardiac Ultrasound
Via, G., Hussain, A., Wells, M., Reardon, R., ElBarbary, M., Noble, V. E., Tsung, J. W., Neskovic, A. N., Price, S., Oren-Grinberg, A., et al. (2014) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2014.05.001 · Cited by 587
Sepsis and Septic Shock – Basics of diagnosis, pathophysiology and clinical decision making
Font, M. D., Thyagarajan, B., & Khanna, A. K. (2020) · Medical Clinics of North America · doi:10.1016/j.mcna.2020.02.011 · Cited by 420
Will This Hemodynamically Unstable Patient Respond to a Bolus of Intravenous Fluids?
Bentzer, P., Griesdale, D. E., Boyd, J., MacLean, K., Sirounis, D., & Ayas, N. T. (2016) · JAMA · doi:10.1001/jama.2016.12310 · Cited by 329
A rational approach to fluid therapy in sepsis
Marik, P., & Bellomo, R. (2016) · British Journal of Anaesthesia · doi:10.1093/bja/aev349 · Cited by 261
How can assessing hemodynamics help to assess volume status?
De Backer, D., Aissaoui, N., Cecconi, M., Chew, M. S., Denault, A., Hajjar, L., Hernandez, G., Messina, A., Myatra, S. N., Ostermann, M., et al. (2022) · Intensive Care Medicine · doi:10.1007/s00134-022-06808-9 · Cited by 199
“Initially described in mechanically ventilated patients [63], the IVC variations were also applied in spontaneously breathing patients but performance was worse, and cutoffs higher than traditionally assumed had to be used [64, 65].”
Background
Metadata
- Authors
- Muller, L., Bobbia, X., Toumi, M., Louart, G., Molinari, N., Ragonnet, B., Quintard, H., Leone, M., Zoric, L., Lefrant, J. Y., & the AzuRea group
- Venue
- Critical Care
- Published
- 2012-10-08
- Volume
- 16
- Issue
- 5
- Pages
- R188-R188
- ISSN
- 1364-8535 (ISSN-L)
- OpenAlex
- W2118966378
- Cited by
- 374
- References
- 37
- FWCI
- 18.64
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.