Concurrent validity of the Fitbit for assessing sedentary behavior and moderate-to-vigorous physical activity
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Recent advances in sensor technologies have promoted the use of consumer-based accelerometers such as Fitbit Flex in epidemiological and clinical research; however, the validity of the Fitbit Flex in measuring sedentary behavior (SED) and physical activity (PA) has not been fully determined against previously validated research-grade accelerometers such as ActiGraph GT3X+. Therefore, the purpose of this study was to examine the concurrent validity of the Fitbit Flex against ActiGraph GT3X+ in a free-living condition. METHODS: A total of 65 participants (age: M = 42, SD = 14 years, female: 72%) each wore a Fitbit Flex and GT3X+ for seven consecutive days. After excluding sleep and non-wear time, time spent (min/day) in SED and moderate-to-vigorous PA (MVPA) were estimated using various cut-points for GT3X+ and brand-specific algorithms for Fitbit, respectively. Repeated measures one-way ANOVA and mean absolute percent errors (MAPE) served to examine differences and measurement errors in SED and MVPA estimates between Fitbit Flex and GT3X+, respectively. Pearson and Spearman correlations and Bland-Altman (BA) plots were used to evaluate the association and potential systematic bias between Fitbit Flex and GT3X+. PROC MIXED procedure in SAS was used to examine the equivalence (i.e., the 90% confidence interval with ±10% equivalence zone) between the devices. RESULTS: Fitbit Flex produced similar SED and low MAPE (mean difference [MD] = 37 min/day, P = .21, MAPE = 6.8%), but significantly higher MVPA and relatively large MAPE (MD = 59-77 min/day, P < .0001, MAPE = 56.6-74.3%) compared with the estimates from GT3X+ using three different cut-points. The correlations between Fitbit Flex and GT3X+ were consistently higher for SED (r = 0.90, ρ = 0.86, P < .01), but weaker for MVPA (r = 0.65-0.76, ρ = 0.69-0.79, P < .01). BA plots revealed that there is no apparent bias in estimating SED. CONCLUSION: In comparison with the GT3X+ accelerometer, the Fitbit Flex provided comparatively accurate estimates of SED, but the Fitbit Flex overestimated MVPA under free-living conditions. Future investigations using the Fitbit Flex should be aware of present findings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825
Too Much Sitting: The Population Health Science of Sedentary Behavior
Owen, N., Healy, G. N., Matthews, C. E., & Dunstan, D. W. (2010) · Exercise and Sport Sciences Reviews · doi:10.1097/jes.0b013e3181e373a2 · Cited by 2,202
Validation of Accelerometer Wear and Nonwear Time Classification Algorithm
CHOI, L., LIU, Z., MATTHEWS, C. E., & BUCHOWSKI, M. S. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181ed61a3 · Cited by 1,804
Validation and comparison of ActiGraph activity monitors
Sasaki, J. E., John, D., & Freedson, P. S. (2011) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2011.04.003 · Cited by 1,317
Age Group Comparability of Raw Accelerometer Output from Wrist- and Hip-Worn Monitors
HILDEBRAND, M., VAN HEES, V. T., HANSEN, B. H., & EKELUND, U. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000289 · Cited by 1,043
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Physical Activity Assessment With Accelerometers: An Evaluation Against Doubly Labeled Water
Plasqui, G., & Westerterp, K. R. (2007) · Obesity · doi:10.1038/oby.2007.281 · Cited by 654
Ferguson, T., Rowlands, A. V., Olds, T., & Maher, C. (2015) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0201-9 · Cited by 468 · cited 1×
“In contrast to previous investigations that have utilized only single cut-point criteria for estimating SED and MVPA from ActiGraph accelerometers [23, 40, 44], we Fig.”
ResultValidity of Consumer-Based Physical Activity Monitors
LEE, J.-M., KIM, Y., & WELK, G. J. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000287 · Cited by 401
Self-citationEstimating energy expenditure using accelerometers
Crouter, S. E., Churilla, J. R., & Bassett, D. R. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-006-0307-5 · Cited by 366
Ellis, K., Kerr, J., Godbole, S., Lanckriet, G., Wing, D., & Marshall, S. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/11/2191 · Cited by 344
Validation of the Fitbit One activity monitor device during treadmill walking
Takacs, J., Pollock, C. L., Guenther, J. R., Bahar, M., Napier, C., & Hunt, M. A. (2014) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2013.10.241 · Cited by 321
Comparison of Step Outputs for Waist and Wrist Accelerometer Attachment Sites
TUDOR-LOCKE, C., BARREIRA, T. V., & SCHUNA, J. M. (2015) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000476 · Cited by 218
Adam Noah, J., Spierer, D. K., Gu, J., & Bronner, S. (2013) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2013.831135 · Cited by 202
Accuracy of 2 Activity Monitors in Detecting Steps in People With Stroke and Traumatic Brain Injury
Fulk, G. D., Combs, S. A., Danks, K. A., Nirider, C. D., Raja, B., & Reisman, D. S. (2014) · Physical Therapy · doi:10.2522/ptj.20120525 · Cited by 182
Sushames, A., Edwards, A., Thompson, F., McDermott, R., & Gebel, K. (2016) · PLOS ONE · doi:10.1371/journal.pone.0161224 · Cited by 152
Comparison of Consumer and Research Monitors under Semistructured Settings
BAI, Y., WELK, G. J., NAM, Y. H., LEE, J. A., LEE, J.-M., KIM, Y., MEIER, N. F., & DIXON, P. M. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000727 · Cited by 149
Self-citationCarlson, S. A., Densmore, D., Fulton, J. E., Yore, M. M., & Kohl, H. W. (2009) · Journal of Physical Activity and Health · doi:10.1123/jpah.6.s1.s18 · Cited by 144
Lee, I.-M., Shiroma, E. J., Evenson, K. R., Kamada, M., LaCroix, A. Z., & Buring, J. E. (2018) · Circulation · doi:10.1161/circulationaha.117.031300 · Cited by 138
Cited by
Germini, F., Noronha, N., Borg Debono, V., Abraham Philip, B., Pete, D., Navarro, T., Keepanasseril, A., Parpia, S., de Wit, K., & Iorio, A. (2022) · Journal of Medical Internet Research · doi:10.2196/30791 · Cited by 220
“[50] and the mean percentage error ranged from –65% to 10% [11,36].”
Rykov, Y., Thach, T.-Q., Bojic, I., Christopoulos, G., & Car, J. (2021) · JMIR mHealth and uHealth · doi:10.2196/24872 · Cited by 151
Smith, K. E., Mason, T. B., Juarascio, A., Schaefer, L. M., Crosby, R. D., Engel, S. G., & Wonderlich, S. A. (2019) · International Journal of Eating Disorders · doi:10.1002/eat.23124 · Cited by 34
Activity Tracker–Based Metrics as Digital Markers of Cardiometabolic Health: Cross-Sectional Study
Rykov, Y., Thach, T.-Q., Dunleavy, G., Roberts, A. C., Christopoulos, G., Soh, C. K., & Car, J. (2020) · JMIR mHealth and uHealth · doi:10.2196/16409 · Cited by 29
Modeling health risks using neural network ensembles
Smith, B. M., Criminisi, A., Sorek, N., Harari, Y., Sood, N., & Heymsfield, S. B. (2024) · PLOS ONE · doi:10.1371/journal.pone.0308922 · Cited by 5
Metadata
- Authors
- Redenius, N., Kim, Y., & Byun, W.
- Venue
- BMC Medical Research Methodology
- Published
- 2019-02-07
- Volume
- 19
- Issue
- 1
- Pages
- 29-29
- ISSN
- 1471-2288 (ISSN-L)
- OpenAlex
- W2919740061
- Cited by
- 78
- References
- 19
- FWCI
- 5.43
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.