Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 24 of the 25 references it cites were found in a registry or an index.

Alterations in hematologic indices during long-duration spaceflight

Open access

Abstract

BACKGROUND: Although a state of anemia is perceived to be associated with spaceflight, to date a peripheral blood hematologic assessment of red blood cell (RBC) indices has not been performed during long-duration space missions. METHODS: This investigation collected whole blood samples from astronauts participating in up to 6-months orbital spaceflight, and returned those samples (ambient storage) to Earth for analysis. As samples were always collected near undock of a returning vehicle, the delay from collection to analysis never exceeded 48 h. As a subset of a larger immunologic investigation, a complete blood count was performed. A parallel stability study of the effect of a 48 h delay on these parameters assisted interpretation of the in-flight data. RESULTS: We report that the RBC and hemoglobin were significantly elevated during flight, both parameters deemed stable through the delay of sample return. Although the stability data showed hematocrit to be mildly elevated at +48 h, there was an in-flight increase in hematocrit that was ~3-fold higher in magnitude than the anticipated increase due to the delay in processing. CONCLUSIONS: While susceptible to the possible influence of dehydration or plasma volume alterations, these results suggest astronauts do not develop persistent anemia during spaceflight.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s12878-017-0083-y

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Blood collection onboard the ISS. Astronaut Nicole Stott performs phlebotomy on the ISS. Samples were collected ~10 h prior to return vehicle undocking (Space Shuttle or Soyuz). Blood samples were returned to the laboratory for analysis within 48 h of collection
Fig. 1 Blood collection onboard the ISS. Astronaut Nicole Stott performs phlebotomy on the ISS. Samples were collected ~10 h prior to return vehicle undocking (Space Shuttle or Soyuz). Blood samples were returned to the laboratory for analysis within 48 h of collectionCC BY · PubMed Central
Fig. 2 Hematologic indices evaluated immediately following blood collection, and 24, 48, and 72 h after collection. All aged samples were compared to the baseline sample analyzed immediately post-collection using two one-sided tests for dependent samples. Data are presented as mean ± standard error. Samples that were not statistically considered equivalent to the baseline sample (p > 0.05) are indicated with *. a Red blood cell concentration (×106 cells/μL); b hemoglobin concentration (g/dL); c mean corpuscular hemoglobin (MCH; pg); d mean corpuscular volume (MCV; fL); e hematocrit (%); and f platelet concentration (×103 cells/μL). All parameters were measured using calibrated automated hematology analyzers
Fig. 2 Hematologic indices evaluated immediately following blood collection, and 24, 48, and 72 h after collection. All aged samples were compared to the baseline sample analyzed immediately post-collection using two one-sided tests for dependent samples. Data are presented as mean ± standard error. Samples that were not statistically considered equivalent to the baseline sample (p > 0.05) are indicated with *. a Red blood cell concentration (×106 cells/μL); b hemoglobin concentration (g/dL); c mean corpuscular hemoglobin (MCH; pg); d mean corpuscular volume (MCV; fL); e hematocrit (%); and f platelet concentration (×103 cells/μL). All parameters were measured using calibrated automated hematology analyzersCC BY · PubMed Central
Fig. 3 Hematologic indices evaluated before, during, and after spaceflight. All samples were compared to the L-180 baseline time point using a linear mixed model with random intercept. Data are presented as mean ± standard error. Significant differences from the L-180 baseline (p < 0.05) are indicated with *. a Red blood cell concentration (×106 cells/μL); b hemoglobin concentration (g/dL); c mean corpuscular hemoglobin (MCH; pg); d mean corpuscular volume (MCV; fL); e hematocrit (%); and f platelet concentration (×103 cells/μL). All parameters were measured using calibrated automated hematology analyzers
Fig. 3 Hematologic indices evaluated before, during, and after spaceflight. All samples were compared to the L-180 baseline time point using a linear mixed model with random intercept. Data are presented as mean ± standard error. Significant differences from the L-180 baseline (p < 0.05) are indicated with *. a Red blood cell concentration (×106 cells/μL); b hemoglobin concentration (g/dL); c mean corpuscular hemoglobin (MCH; pg); d mean corpuscular volume (MCV; fL); e hematocrit (%); and f platelet concentration (×103 cells/μL). All parameters were measured using calibrated automated hematology analyzersCC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 25 references

Cited by

See all 85

Metadata

Authors
Kunz, H., Quiriarte, H., Simpson, R. J., Ploutz-Snyder, R., McMonigal, K., Sams, C., & Crucian, B.
Affiliations
  • Wyle (United States) (US)
  • Louisiana State University (US)
  • University of Houston (US)
  • University of Michigan (US)
  • Johnson Space Center (US)
Corresponding author
Crucian, Brian
Venue
BMC Hematology
Published
2017-09-08
Volume
17
Issue
1
Pages
12-12
ISSN
2052-1839 (ISSN-L)
OpenAlex
W2746657538
Cited by
80
References
25
Citations by year
2026: 6 · 2025: 12 · 2024: 11 · 2023: 9 · 2022: 13 · 2021: 9 · 2020: 7 · 2019: 9 · 2018: 4
FWCI
4.05
Type
journal article
Language
en
Open access
Licence
Locations
  • BMC Hematology (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Funders
National Aeronautics and Space Administration (SMO-015, NNJ10ZSA003N)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Spaceflight effects on biology
  • Health Sciences › Medicine › Physiology (medical) › High Altitude and Hypoxia
  • Physical Sciences › Engineering › Aerospace Engineering › Space Exploration and Technology
Keywords
long-duration spaceflight, astronauts, anemia, red blood cell indices, hematocrit, hemoglobin, hematological changes, sample storage stability, dehydration, plasma volume

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Alterations in hematologic indices during long-duration spaceflight. https://app.cochat.ai/papers/10.1186/s12878-017-0083-y
The paper
Kunz, H., Quiriarte, H., Simpson, R. J., Ploutz-Snyder, R., McMonigal, K., Sams, C., & Crucian, B. (2017). Alterations in hematologic indices during long-duration spaceflight. BMC Hematology. https://doi.org/10.1186/s12878-017-0083-y

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.