The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Size-isolation of superparamagnetic iron oxide nanoparticles improves MRI, MPI and hyperthermia performance
Open accessAbstract
Superparamagnetic iron oxide nanoparticles (SPION) are extensively used for magnetic resonance imaging (MRI) and magnetic particle imaging (MPI), as well as for magnetic fluid hyperthermia (MFH). We here describe a sequential centrifugation protocol to obtain SPION with well-defined sizes from a polydisperse SPION starting formulation, synthesized using the routinely employed co-precipitation technique. Transmission electron microscopy, dynamic light scattering and nanoparticle tracking analyses show that the SPION fractions obtained upon size-isolation are well-defined and almost monodisperse. MRI, MPI and MFH analyses demonstrate improved imaging and hyperthermia performance for size-isolated SPION as compared to the polydisperse starting mixture, as well as to commercial and clinically used iron oxide nanoparticle formulations, such as Resovist® and Sinerem®. The size-isolation protocol presented here may help to identify SPION with optimal properties for diagnostic, therapeutic and theranostic applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Laurent, S., Forge, D., Port, M., Roch, A., Robic, C., Vander Elst, L., & Muller, R. N. (2008) · Chemical Reviews · doi:10.1021/cr068445e · Cited by 6,852
Ultra-large-scale syntheses of monodisperse nanocrystals
Park, J., An, K., Hwang, Y., Park, J.-G., Noh, H.-J., Kim, J.-Y., Park, J.-H., Hwang, N.-M., & Hyeon, T. (2004) · Nature Materials · doi:10.1038/nmat1251 · Cited by 4,076
Wu, W., Wu, Z., Yu, T., Jiang, C., & Kim, W.-S. (2015) · Science and Technology of Advanced Materials · doi:10.1088/1468-6996/16/2/023501 · Cited by 1,574
Magnetic fluid hyperthermia: focus on superparamagnetic iron oxide nanoparticles
Laurent, S., Dutz, S., Häfeli, U. O., & Mahmoudi, M. (2011) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2011.04.003 · Cited by 1,326
Potential toxicity of superparamagnetic iron oxide nanoparticles (SPION)
Singh, N., Jenkins, G. J. S., Asadi, R., & Doak, S. H. (2010) · Nano Reviews · doi:10.3402/nano.v1i0.5358 · Cited by 1,112
Size-dependent toxicity of metal oxide particles—A comparison between nano- and micrometer size
Karlsson, H. L., Gustafsson, J., Cronholm, P., & Möller, L. (2009) · Toxicology Letters · doi:10.1016/j.toxlet.2009.03.014 · Cited by 949
Clinical applications of magnetic nanoparticles for hyperthermia
Thiesen, B., & Jordan, A. (2008) · International Journal of Hyperthermia · doi:10.1080/02656730802104757 · Cited by 829 · cited 1×
“As a result of these three mechanisms, SPION and magnetic temperature gradually increase in an AFM until a saturation temperature is achieved [37, 38].”
BackgroundProgress in electrochemical synthesis of magnetic iron oxide nanoparticles
Ramimoghadam, D., Bagheri, S., & Hamid, S. B. A. (2014) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2014.05.015 · Cited by 285
Smolensky, E. D., Park, H.-Y. E., Zhou, Y., Rolla, G. A., Marjańska, M., Botta, M., & Pierre, V. C. (2013) · Journal of Materials Chemistry B · doi:10.1039/c3tb00369h · Cited by 156 · cited 1×
“9 to 18 nm), while r1 values remained relatively constant for particles with core sizes larger than 8 nm [33].”
BackgroundDesign of superparamagnetic nanoparticles for magnetic particle imaging (MPI)
Du, Y., Lai, P., Leung, C., & Pong, P. (2013) · International Journal of Molecular Sciences · doi:10.3390/ijms140918682 · Cited by 81 · cited 3×
“These considerations exemplify that it is crucial to identify the optimal size for the anticipated biomedical application [25, 26], and they underline the importance of developing tools, such as the centrifugation protocol presented here, to prepare SPION formulations with distinct sizes and with low polydispersity.”
BackgroundMethod
Cited by
Advancement of magnetic particle imaging in diagnosis and therapy
Harini, K., Girigoswami, K., Pallavi, P., Gowtham, P., Prabhu, A. D., & Girigoswami, A. (2024) · Advances in Natural Sciences: Nanoscience and Nanotechnology · doi:10.1088/2043-6262/ad3b7a · Cited by 8
Metadata
- Authors
- Dadfar, S. M., Camozzi, D., Darguzyte, M., Roemhild, K., Varvarà, P., Metselaar, J., Banala, S., Straub, M., Güvener, N., Engelmann, U., Slabu, I., Buhl, M., van Leusen, J., Kögerler, P., Hermanns-Sachweh, B., Schulz, V., Kiessling, F., & Lammers, T.
- Venue
- Journal of Nanobiotechnology
- Published
- 2020-01-28
- Volume
- 18
- Issue
- 1
- Pages
- 22-22
- ISSN
- 1477-3155 (ISSN-L)
- OpenAlex
- W3003454644
- Cited by
- 222
- References
- 10
- FWCI
- 8.99
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Size-isolation of superparamagnetic iron oxide nanoparticles improves MRI, MPI and hyperthermia performance. https://app.cochat.ai/papers/10.1186/s12951-020-0580-1
- The paper
- Dadfar, S. M., Camozzi, D., Darguzyte, M., Roemhild, K., Varvarà, P., Metselaar, J., Banala, S., Straub, M., Güvener, N., Engelmann, U., Slabu, I., Buhl, M., van Leusen, J., Kögerler, P., Hermanns-Sachweh, B., Schulz, V., Kiessling, F., & Lammers, T. (2020). Size-isolation of superparamagnetic iron oxide nanoparticles improves MRI, MPI and hyperthermia performance. Journal of Nanobiotechnology. https://doi.org/10.1186/s12951-020-0580-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.