The H2 robotic exoskeleton for gait rehabilitation after stroke: early findings from a clinical study
Open accessThe DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Stroke significantly affects thousands of individuals annually, leading to considerable physical impairment and functional disability. Gait is one of the most important activities of daily living affected in stroke survivors. Recent technological developments in powered robotics exoskeletons can create powerful adjunctive tools for rehabilitation and potentially accelerate functional recovery. Here, we present the development and evaluation of a novel lower limb robotic exoskeleton, namely H2 (Technaid S.L., Spain), for gait rehabilitation in stroke survivors. METHODS: H2 has six actuated joints and is designed to allow intensive overground gait training. An assistive gait control algorithm was developed to create a force field along a desired trajectory, only applying torque when patients deviate from the prescribed movement pattern. The device was evaluated in 3 hemiparetic stroke patients across 4 weeks of training per individual (approximately 12 sessions). The study was approved by the Institutional Review Board at the University of Houston. The main objective of this initial pre-clinical study was to evaluate the safety and usability of the exoskeleton. A Likert scale was used to measure patient's perception about the easy of use of the device. RESULTS: Three stroke patients completed the study. The training was well tolerated and no adverse events occurred. Early findings demonstrate that H2 appears to be safe and easy to use in the participants of this study. The overground training environment employed as a means to enhance active patient engagement proved to be challenging and exciting for patients. These results are promising and encourage future rehabilitation training with a larger cohort of patients. CONCLUSIONS: The developed exoskeleton enables longitudinal overground training of walking in hemiparetic patients after stroke. The system is robust and safe when applied to assist a stroke patient performing an overground walking task. Such device opens the opportunity to study means to optimize a rehabilitation treatment that can be customized for individuals. TRIAL REGISTRATION: This study was registered at ClinicalTrials.gov ( https://clinicaltrials.gov/show/NCT02114450 ).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics and motor control of human movement
(1990) · Choice Reviews Online · doi:10.5860/choice.28-2135 · Cited by 8,451
Heart Disease and Stroke Statistics—2023 Update: A Report From the American Heart Association
Tsao, C. W., Aday, A. W., Almarzooq, Z. I., Anderson, C. A. M., Arora, P., Avery, C. L., Baker-Smith, C. M., Beaton, A. Z., Boehme, A. K., Buxton, A. E., et al. (2023) · Circulation · doi:10.1161/cir.0000000000001123 · Cited by 8,300
Heart Disease and Stroke Statistics—2011 Update: A Report From the American Heart Association
Roger, V. L., Go, A. S., Lloyd-Jones, D. M., Adams, R. J., Berry, J. D., Brown, T. M., Carnethon, M. R., Dai, S., de Simone, G., Ford, E. S., et al. (2011) · Circulation · doi:10.1161/cir.0b013e3182009701 · Cited by 6,149
Biomechanics and Motor Control of Human Movement
Winter, D. A. (2009) · Wiley eBooks · doi:10.1002/9780470549148 · Cited by 6,066
Feigin, V. L., Lawes, C. M., Bennett, D. A., Barker-Collo, S. L., & Parag, V. (2009) · The Lancet Neurology · doi:10.1016/s1474-4422(09)70025-0 · Cited by 2,855 · cited 1×
“Introduction Stroke is the main cause of serious long-term disability worldwide [1] and gait is one of the most important activities affected in stroke survivors.”
BackgroundMozaffarian, D., Benjamin, E. J., Go, A. S., Arnett, D. K., Blaha, M. J., Cushman, M., Das, S. R., de Ferranti, S., Després, J.-P., Fullerton, H. J., et al. (2016) · Circulation · doi:10.1161/cir.0000000000000366 · Cited by 2,466
Lower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art
Dollar, A. M., & Herr, H. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.915453 · Cited by 1,327
Treadmill training of paraplegic patients using a robotic orthosis.
Colombo, G., Joerg, M., Schreier, R., & Dietz, V. (2000) · PubMed · Cited by 1,290
Design and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation
Veneman, J. F., Kruidhof, R., Hekman, E. E. G., Ekkelenkamp, R., Van Asseldonk, E. H. F., & van der Kooij, H. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903919 · Cited by 1,280
Biomechanical design of the Berkeley lower extremity exoskeleton (BLEEX)
Zoss, A. B., Kazerooni, H., & Chu, A. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.871087 · Cited by 1,170
Recovery of walking function in stroke patients: The copenhagen stroke study
Jørgensen, H. S., Nakayama, H., Raaschou, H. O., & Olsen, T. S. (1995) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(95)80038-7 · Cited by 1,164
Management of Adult Stroke Rehabilitation Care: A Clinical Practice Guideline
Duncan, P. W., Zorowitz, R., Bates, B., Choi, J. Y., Glasberg, J. J., Graham, G. D., Katz, R. C., Lamberty, K., & Reker, D. (2005) · Stroke · doi:10.1161/01.str.0000180861.54180.ff · Cited by 1,046
Esquenazi, A., Talaty, M., Packel, A., & Saulino, M. (2012) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e318269d9a3 · Cited by 958 · cited 1×
“Other ambulatory exoskeletons that have been evaluated for clinical use are ReWalk [25], Vanderbilt exoskeleton [26], Ekso [27] and Kinesis [28].”
MethodRobot assisted gait training with Active Leg Exoskeleton (ALEX)
Banala, S. K., Kim, S. H., Agrawal, S. K., & Scholz, J. P. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2008280 · Cited by 751
Motor learning elicited by voluntary drive
Lotze, M. (2003) · Brain · doi:10.1093/brain/awg079 · Cited by 691 · cited 1×
“Assisting only when patients need it can lead to better results than fixed repetitive training as it is more personalized to each individual ensuring consistent patient engagement in the training [35].”
BackgroundRehabilitation of gait after stroke: a review towards a top-down approach
Belda-Lois, J.-M., Mena-del Horno, S., Bermejo-Bosch, I., Moreno, J. C., Pons, J. L., Farina, D., Iosa, M., Molinari, M., Tamburella, F., Ramos, A., et al. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-66 · Cited by 581
Self-citationLower-Limb Robotic Rehabilitation: Literature Review and Challenges
Díaz, I., Gil, J. J., & Sánchez, E. (2011) · Journal of Robotics · doi:10.1155/2011/759764 · Cited by 541
Exoskeletons and orthoses: classification, design challenges and future directions
Herr, H. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-21 · Cited by 477
Compliant actuation of rehabilitation robots
Vallery, H., Veneman, J., van Asseldonk, E., Ekkelenkamp, R., Buss, M., & van Der Kooij, H. (2008) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2008.927689 · Cited by 448
A mechanized gait trainer for restoration of gait.
Hesse, S., & Uhlenbrock, D. (2000) · PubMed · Cited by 388
Power assist method based on Phase Sequence and muscle force condition for HAL
Kawamoto, H., & Sankai, Y. (2005) · Advanced Robotics · doi:10.1163/1568553054455103 · Cited by 381
Preliminary Evaluation of a Powered Lower Limb Orthosis to Aid Walking in Paraplegic Individuals
Farris, R. J., Quintero, H. A., & Goldfarb, M. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2163083 · Cited by 342
Treadmill training and body weight support for walking after stroke
Moseley, A. M., Stark, A., Cameron, I. D., & Pollock, A. (2005) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd002840.pub2 · Cited by 338
Jiménez-Fabián, R., & Verlinden, O. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.11.018 · Cited by 313
Sit-to-stand and stand-to-sit transfer support for complete paraplegic patients with robot suit HAL
Tsukahara, A., Kawanishi, R., Hasegawa, Y., & Sankai, Y. (2010) · Advanced Robotics · doi:10.1163/016918610x512622 · Cited by 269 · cited 1×
“Two different control strategies are used with HAL, depending on the treatment purpose and user’s capabilities [19].”
MethodGait rehabilitation machines based on programmable footplates
Schmidt, H., Werner, C., Bernhardt, R., Hesse, S., & Krüger, J. (2007) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-4-2 · Cited by 256
Aoyagi, D., Ichinose, W. E., Harkema, S. J., Reinkensmeyer, D. J., & Bobrow, J. E. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903922 · Cited by 249
The rise of the body bots [robotic exoskeletons
Guizzo, E., & Goldstein, H. (2005) · IEEE Spectrum · doi:10.1109/mspec.2005.1515961 · Cited by 238
Nilsson, A., Vreede, K., Häglund, V., Kawamoto, H., Sankai, Y., & Borg, J. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-92 · Cited by 206
Hybrid FES-robot cooperative control of ambulatory gait rehabilitation exoskeleton
del-Ama, A. J., Gil-Agudo, Á., Pons, J. L., & Moreno, J. C. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-27 · Cited by 190
Self-citationRole of Voluntary Drive in Encoding an Elementary Motor Memory
Kaelin-Lang, A., Sawaki, L., & Cohen, L. G. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00143.2004 · Cited by 190
Development of single leg version of HAL for hemiplegia
Kawamoto, H., Hayashi, T., Sakurai, T., Eguchi, K., & Sankai, Y. (2009) · 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2009.5333698 · Cited by 182
Novel gait adaptation and neuromotor training results using an active leg exoskeleton
Banala, S. K., Agrawal, S. K., Kim, S. H., & Scholz, J. P. (2010) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2010.2041245 · Cited by 165 · cited 1×
“Body weight support with treadmill training machines, such as Lokomat [11], ALEX [12] and LOPES [13], have been used for gait training in stroke victims.”
MethodDesign of an electrically actuated lower extremity exoskeleton
Zoss, A., & Kazerooni, H. (2006) · Advanced Robotics · doi:10.1163/156855306778394030 · Cited by 160
Robot assisted gait training with active leg exoskeleton (ALEX)
Banala, S. K., Kim, S. H., Agrawal, S. K., & Scholz, J. P. (2008) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2008.4762885 · Cited by 140
Mak, K. Y., & Lau, K. K. (2011) · Journal of Rehabilitation Medicine · doi:10.2340/16501977-0838 · Cited by 128
Robot assisted treadmill training: Mechanisms and training strategies
Hussain, S., Xie, S. Q., & Liu, G. (2011) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.12.010 · Cited by 122
Franceschini, M., Carda, S., Agosti, M., Antenucci, R., Malgrati, D., & Cisari, C. (2009) · Stroke · doi:10.1161/strokeaha.109.555540 · Cited by 120
Executive Summary: Heart Disease and Stroke Statistics—2011 Update
Roger, V. L., Go, A. S., Lloyd‐Jones, D. M., Adams, R. J., Berry, J. D., Brown, T. M., Carnethon, M. R., Dai, S., SIMONE, G. D., Ford, E. S., et al. (2011) · Circulation · doi:10.1161/cir.0b013e31820c7a50 · Cited by 107
Design and Actuator Selection of a Lower Extremity Exoskeleton
Önen, Ü., Botsalı, F. M., Kalyoncu, M., Tınkır, M., Yılmaz, N., & Şahin, Y. (2013) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2013.2250295 · Cited by 97
Effects of Robotic Knee Exoskeleton on Human Energy Expenditure
Gams, A., Petrič, T., Debevec, T., & Babič, J. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2240682 · Cited by 95
Efficacy of a hybrid assistive limb in post-stroke hemiplegic patients: a preliminary report
Maeshima, S., Osawa, A., Nishio, D., Hirano, Y., Takeda, K., Kigawa, H., & Sankai, Y. (2011) · BMC Neurology · doi:10.1186/1471-2377-11-116 · Cited by 90
Fan, Y., & Yin, Y. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2267741 · Cited by 86
Wisneski, K. J., & Johnson, M. J. (2007) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-4-7 · Cited by 82
Applications of Brain–Machine Interface Systems in Stroke Recovery and Rehabilitation
Venkatakrishnan, A., Francisco, G. E., & Contreras-Vidal, J. L. (2014) · Current Physical Medicine and Rehabilitation Reports · doi:10.1007/s40141-014-0051-4 · Cited by 78
Self-citationRobotic Gait Rehabilitation Trainer
Pietrusinski, M. D., Cajigas, I., Severini, G., Bonato, P., & Mavroidis, C. (2013) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2013.2243915 · Cited by 68
He, Y., Nathan, K., Venkatakrishnan, A., Rovekamp, R., Beck, C., Ozdemir, R. A., Francisco, G. E., & Contreras-Vidal, J. L. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944497 · Cited by 67
Self-citationA pilot clinical study on robotic assisted rehabilitation in VR with an arm exoskeleton device
Montagner, A., Frisoli, A., Borelli, L., Procopio, C., Bergamasco, M., Carboncini, M. C., & Rossi, B. (2007) · International Conference on Virtual Rehabilitation · doi:10.1109/icvr.2007.4362131 · Cited by 66
A robotic exoskeleton for overground gait rehabilitation
Bôrtole, M., del‐Ama, A. J., Rocón, E., Moreno, J. C., Brunetti, F., & Pons, J. L. (2013) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2013.6631045 · Cited by 61
Self-citation
Cited by
Systematic review on wearable lower-limb exoskeletons for gait training in neuromuscular impairments
Rodríguez-Fernández, A., Lobo-Prat, J., & Font-Llagunes, J. M. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00815-5 · Cited by 435
Review of control strategies for lower-limb exoskeletons to assist gait
Baud, R., Manzoori, A. R., Ijspeert, A., & Bouri, M. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00906-3 · Cited by 381
Powered robotic exoskeletons in post-stroke rehabilitation of gait: a scoping review
Louie, D. R., & Eng, J. J. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0162-5 · Cited by 350
A Gentle Introduction to Reinforcement Learning and its Application in Different Fields
Naeem, M., Rizvi, S. T. H., & Coronato, A. (2020) · IEEE Access · doi:10.1109/access.2020.3038605 · Cited by 257
Robotic Rehabilitation and Spinal Cord Injury: a Narrative Review
Mekki, M., Delgado, A. D., Fry, A., Putrino, D., & Huang, V. (2018) · Neurotherapeutics · doi:10.1007/s13311-018-0642-3 · Cited by 216
Metadata
- Authors
- Bortole, M., Venkatakrishnan, A., Zhu, F., Moreno, J. C., Francisco, G. E., Pons, J. L., & Contreras-Vidal, J. L.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2015-06-17
- Volume
- 12
- Issue
- 1
- Pages
- 54-54
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W1580648284
- Cited by
- 347
- References
- 49
- FWCI
- 16.67
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.