Interactive wearable systems for upper body rehabilitation: a systematic review
Open accessThe DOI matches its Crossref record; 85 of the 85 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The development of interactive rehabilitation technologies which rely on wearable-sensing for upper body rehabilitation is attracting increasing research interest. This paper reviews related research with the aim: 1) To inventory and classify interactive wearable systems for movement and posture monitoring during upper body rehabilitation, regarding the sensing technology, system measurements and feedback conditions; 2) To gauge the wearability of the wearable systems; 3) To inventory the availability of clinical evidence supporting the effectiveness of related technologies. METHOD: A systematic literature search was conducted in the following search engines: PubMed, ACM, Scopus and IEEE (January 2010-April 2016). RESULTS: Forty-five papers were included and discussed in a new cuboid taxonomy which consists of 3 dimensions: sensing technology, feedback modalities and system measurements. Wearable sensor systems were developed for persons in: 1) Neuro-rehabilitation: stroke (n = 21), spinal cord injury (n = 1), cerebral palsy (n = 2), Alzheimer (n = 1); 2) Musculoskeletal impairment: ligament rehabilitation (n = 1), arthritis (n = 1), frozen shoulder (n = 1), bones trauma (n = 1); 3) Others: chronic pulmonary obstructive disease (n = 1), chronic pain rehabilitation (n = 1) and other general rehabilitation (n = 14). Accelerometers and inertial measurement units (IMU) are the most frequently used technologies (84% of the papers). They are mostly used in multiple sensor configurations to measure upper limb kinematics and/or trunk posture. Sensors are placed mostly on the trunk, upper arm, the forearm, the wrist, and the finger. Typically sensors are attachable rather than embedded in wearable devices and garments; although studies that embed and integrate sensors are increasing in the last 4 years. 16 studies applied knowledge of result (KR) feedback, 14 studies applied knowledge of performance (KP) feedback and 15 studies applied both in various modalities. 16 studies have conducted their evaluation with patients and reported usability tests, while only three of them conducted clinical trials including one randomized clinical trial. CONCLUSIONS: This review has shown that wearable systems are used mostly for the monitoring and provision of feedback on posture and upper extremity movements in stroke rehabilitation. The results indicated that accelerometers and IMUs are the most frequently used sensors, in most cases attached to the body through ad hoc contraptions for the purpose of improving range of motion and movement performance during upper body rehabilitation. Systems featuring sensors embedded in wearable appliances or garments are only beginning to emerge. Similarly, clinical evaluations are scarce and are further needed to provide evidence on effectiveness and pave the path towards implementation in clinical settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
Preferred reporting items for systematic reviews and meta-analyses: the PRISMA Statement.
(2009) · PubMed Central · Cited by 44,859
Preferred reporting items for systematic reviews and meta-analyses: The PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & the PRISMA Group* (2009) · Annals of Internal Medicine · doi:10.7326/0003-4819-151-4-200908180-00135 · Cited by 37,554
A stretchable carbon nanotube strain sensor for human-motion detection
Yamada, T., Hayamizu, Y., Yamamoto, Y., Yomogida, Y., Izadi-Najafabadi, A., Futaba, D. N., & Hata, K. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.36 · Cited by 3,247
A review of wearable sensors and systems with application in rehabilitation
Patel, S., Park, H., Bonato, P., Chan, L., & Rodgers, M. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-21 · Cited by 2,396
Augmented visual, auditory, haptic, and multimodal feedback in motor learning: A review
Sigrist, R., Rauter, G., Riener, R., & Wolf, P. (2013) · Psychonomic Bulletin & Review · doi:10.3758/s13423-012-0333-8 · Cited by 1,416 · cited 3×
“Besides simple abstract feedback, the global feedback [8] about the posture and position could be provided in a more natural way, which is classified as natural visualizations [84].”
Motor Learning and Control : Concepts and Applications
Magill, R. A. (2020) · LSU Scholarly Repository (Louisiana State University) · Cited by 1,306
A Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity Monitoring
Yang, C.-C., & Hsu, Y.-L. (2010) · Sensors · doi:10.3390/s100807772 · Cited by 1,058
What Do Motor “Recovery” and “Compensation” Mean in Patients Following Stroke?
Levin, M. F., Kleim, J. A., & Wolf, S. L. (2009) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968308328727 · Cited by 952
Proceedings of the SIGCHI Conference on Human Factors in Computing Systems
(2003) · doi:10.1145/642611 · Cited by 905
Cited by
Wearable health devices in health care: narrative systematic review
Lu, L., Zhang, J., Xie, Y., Gao, F., Xu, S., Wu, X., & Ye, Z. (2020) · JMIR mHealth and uHealth · doi:10.2196/18907 · Cited by 701
Duan, L., D'hooge, D. R., & Cardon, L. (2020) · Progress in Materials Science · doi:10.1016/j.pmatsci.2019.100617 · Cited by 554
Wireless battery-free body sensor networks using near-field-enabled clothing
Lin, R., Kim, H.-J., Achavananthadith, S., Kurt, S. A., Tan, S. C. C., Yao, H., Tee, B. C. K., Lee, J. K. W., & Ho, J. S. (2020) · Nature Communications · doi:10.1038/s41467-020-14311-2 · Cited by 331
Systematic Review on Kinematic Assessments of Upper Limb Movements After Stroke
Schwarz, A., Kanzler, C. M., Lambercy, O., Luft, A. R., & Veerbeek, J. M. (2019) · Stroke · doi:10.1161/strokeaha.118.023531 · Cited by 313
Zhang, Q., Xin, C., Shen, F., Gong, Y., Zi, Y., Guo, H., Li, Z., Peng, Y., Zhang, Q., & Wang, Z. L. (2022) · Energy & Environmental Science · doi:10.1039/d2ee01590k · Cited by 239
Chae, S. H., Kim, Y., Lee, K.-S., & Park, H.-S. (2020) · JMIR mHealth and uHealth · doi:10.2196/17216 · Cited by 235
“According to previous research that used an IMU sensor for activity recognition, an accelerometer is the most accurate sensor for activity recognition [29,30,33-36].”
Wearable E-Textile Technologies: A Review on Sensors, Actuators and Control Elements
Gonçalves, C., Ferreira da Silva, A., Gomes, J., & Simoes, R. (2018) · Inventions · doi:10.3390/inventions3010014 · Cited by 208
“The EMG signal measurement is useful to evaluate physiotherapy treatment of gait cycle disorders or stroke rehabilitation [67].”
BackgroundArtificial Intelligence-Based Wearable Robotic Exoskeletons for Upper Limb Rehabilitation: A Review
Vélez-Guerrero, M. A., Callejas-Cuervo, M., & Mazzoleni, S. (2021) · Sensors · doi:10.3390/s21062146 · Cited by 187
“The design of rehabilitation technology is usually not followed by full or partial clinical trials; thus, such developments do not find direct applicability in medi‐ cal or rehabilitation centres [14], which is important to pave the way for an implementa‐ tion in the clinical practice.”
BackgroundO’Reilly, M., Caulfield, B., Ward, T., Johnston, W., & Doherty, C. (2018) · Sports Medicine · doi:10.1007/s40279-018-0878-4 · Cited by 186
“that classified studies involving upper limb wearable systems for rehabilitation [27].”
BackgroundSoft, Wearable Robotics and Haptics: Technologies, Trends, and Emerging Applications
Zhu, M., Biswas, S., Dinulescu, S. I., Kastor, N., Hawkes, E. W., & Visell, Y. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2021.3140049 · Cited by 172
Rodgers, M. M., Alon, G., Pai, V. M., & Conroy, R. S. (2019) · Journal of Rehabilitation and Assistive Technologies Engineering · doi:10.1177/2055668319839607 · Cited by 119
Correia, F. D., Molinos, M., Luís, S., Carvalho, D., Carvalho, C., Costa, P., Seabra, R., Francisco, G., Bento, V., & Lains, J. (2022) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0000000000001780 · Cited by 52
Janela, D., Costa, F., Weiss, B., Areias, A. C., Molinos, M., Scheer, J. K., Lains, J., Bento, V., Cohen, S. P., Correia, F. D., et al. (2023) · DIGITAL HEALTH · doi:10.1177/20552076231176696 · Cited by 18
“Such technologies guide patients during sessions and promote close remote monitoring on patient progress, thereby permitting individualized support and reinforcing accountability.(19,20) Additionally, movement digitalization with respective data storage in web platforms may assist therapists in patient monitoring and…”
BackgroundA Novel Compensatory Motion Detection Method Using Multiple Signals and Machine Learning
Xu, P., Xia, D., Zheng, B., Huang, L., & Xie, L. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3190503 · Cited by 12
Technological Interventions for Pain Management
Suso-Ribera, C., Castilla, D., Martínez-Borba, V., Jaén, I., Botella, C., Baños, R. M., & García-Palacios, A. (2022) · Comprehensive Clinical Psychology · doi:10.1016/b978-0-12-818697-8.00009-1 · Cited by 6
Metadata
- Authors
- Wang, Q., Markopoulos, P., Yu, B., Chen, W., & Timmermans, A.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2017-03-11
- Volume
- 14
- Issue
- 1
- Pages
- 20-20
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W2591746674
- Cited by
- 348
- References
- 85
- FWCI
- 6.67
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.