Interactive wearable systems for upper body rehabilitation: a systematic review
Open accessThe DOI matches its Crossref record; 85 of the 85 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The development of interactive rehabilitation technologies which rely on wearable-sensing for upper body rehabilitation is attracting increasing research interest. This paper reviews related research with the aim: 1) To inventory and classify interactive wearable systems for movement and posture monitoring during upper body rehabilitation, regarding the sensing technology, system measurements and feedback conditions; 2) To gauge the wearability of the wearable systems; 3) To inventory the availability of clinical evidence supporting the effectiveness of related technologies. METHOD: A systematic literature search was conducted in the following search engines: PubMed, ACM, Scopus and IEEE (January 2010-April 2016). RESULTS: Forty-five papers were included and discussed in a new cuboid taxonomy which consists of 3 dimensions: sensing technology, feedback modalities and system measurements. Wearable sensor systems were developed for persons in: 1) Neuro-rehabilitation: stroke (n = 21), spinal cord injury (n = 1), cerebral palsy (n = 2), Alzheimer (n = 1); 2) Musculoskeletal impairment: ligament rehabilitation (n = 1), arthritis (n = 1), frozen shoulder (n = 1), bones trauma (n = 1); 3) Others: chronic pulmonary obstructive disease (n = 1), chronic pain rehabilitation (n = 1) and other general rehabilitation (n = 14). Accelerometers and inertial measurement units (IMU) are the most frequently used technologies (84% of the papers). They are mostly used in multiple sensor configurations to measure upper limb kinematics and/or trunk posture. Sensors are placed mostly on the trunk, upper arm, the forearm, the wrist, and the finger. Typically sensors are attachable rather than embedded in wearable devices and garments; although studies that embed and integrate sensors are increasing in the last 4 years. 16 studies applied knowledge of result (KR) feedback, 14 studies applied knowledge of performance (KP) feedback and 15 studies applied both in various modalities. 16 studies have conducted their evaluation with patients and reported usability tests, while only three of them conducted clinical trials including one randomized clinical trial. CONCLUSIONS: This review has shown that wearable systems are used mostly for the monitoring and provision of feedback on posture and upper extremity movements in stroke rehabilitation. The results indicated that accelerometers and IMUs are the most frequently used sensors, in most cases attached to the body through ad hoc contraptions for the purpose of improving range of motion and movement performance during upper body rehabilitation. Systems featuring sensors embedded in wearable appliances or garments are only beginning to emerge. Similarly, clinical evaluations are scarce and are further needed to provide evidence on effectiveness and pave the path towards implementation in clinical settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
Preferred reporting items for systematic reviews and meta-analyses: the PRISMA Statement.
(2009) · PubMed Central · Cited by 44,859
Preferred reporting items for systematic reviews and meta-analyses: The PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & the PRISMA Group* (2009) · Annals of Internal Medicine · doi:10.7326/0003-4819-151-4-200908180-00135 · Cited by 37,554
A stretchable carbon nanotube strain sensor for human-motion detection
Yamada, T., Hayamizu, Y., Yamamoto, Y., Yomogida, Y., Izadi-Najafabadi, A., Futaba, D. N., & Hata, K. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.36 · Cited by 3,247
A review of wearable sensors and systems with application in rehabilitation
Patel, S., Park, H., Bonato, P., Chan, L., & Rodgers, M. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-21 · Cited by 2,396
Augmented visual, auditory, haptic, and multimodal feedback in motor learning: A review
Sigrist, R., Rauter, G., Riener, R., & Wolf, P. (2013) · Psychonomic Bulletin & Review · doi:10.3758/s13423-012-0333-8 · Cited by 1,416 · cited 3×
“Besides simple abstract feedback, the global feedback [8] about the posture and position could be provided in a more natural way, which is classified as natural visualizations [84].”
Motor Learning and Control : Concepts and Applications
Magill, R. A. (2020) · LSU Scholarly Repository (Louisiana State University) · Cited by 1,306
A Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity Monitoring
Yang, C.-C., & Hsu, Y.-L. (2010) · Sensors · doi:10.3390/s100807772 · Cited by 1,058
What Do Motor “Recovery” and “Compensation” Mean in Patients Following Stroke?
Levin, M. F., Kleim, J. A., & Wolf, S. L. (2009) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968308328727 · Cited by 952
Proceedings of the SIGCHI Conference on Human Factors in Computing Systems
(2003) · doi:10.1145/642611 · Cited by 905
A Comprehensive Survey of Wireless Body Area Networks: On PHY, MAC, and Network Layers Solutions
Ullah, S., Higgins, H., Braem, B., Latre, B., Blondia, C., Moerman, I., Saleem, S., Rahman, Z., & Kwak, K. S. (2012) · Journal of Medical Systems · doi:10.1007/s10916-010-9571-3 · Cited by 811 · cited 1×
“Recently, the miniaturization of devices, the evolution of sensing and body area network technologies [15, 16] has triggered the increasing influence of wearable rehabilitation technology, offering advantages over traditional rehabilitation services [17, 18], such as: low cost, flexible application, remote monitoring,…”
Action observation has a positive impact on rehabilitation of motor deficits after stroke
Ertelt, D., Small, S., Solodkin, A., Dettmers, C., McNamara, A., Binkofski, F., & Buccino, G. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.03.043 · Cited by 663
Virtual Reality in Stroke Rehabilitation: A Meta-Analysis and Implications for Clinicians
Saposnik, G., Levin, M., & for the Stroke Outcome Research Canada (SORCan) Working Group (2011) · Stroke · doi:10.1161/strokeaha.110.605451 · Cited by 629
Timmermans, A. A., Seelen, H. A., Willmann, R. D., & Kingma, H. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-1 · Cited by 483
Self-citationRecent development of mechanisms and control strategies for robot-assisted lower limb rehabilitation
Meng, W., Liu, Q., Zhou, Z., Ai, Q., Sheng, B., & Xie, S. (. (2015) · Mechatronics · doi:10.1016/j.mechatronics.2015.04.005 · Cited by 464
Highly Stretchy Black Gold E‐Skin Nanopatches as Highly Sensitive Wearable Biomedical Sensors
Gong, S., Lai, D. T. H., Su, B., Si, K. J., Ma, Z., Yap, L. W., Guo, P., & Cheng, W. (2015) · Advanced Electronic Materials · doi:10.1002/aelm.201400063 · Cited by 461 · cited 1×
“…they have been excluded from the survey as they are only sensing technologies which do not support yet any user feed-back: conductive thread based stretch sensors [85], a conductive elastomer sensor based system [20], stretchable carbon nanotube strain sensors [86] and soft nano-patches [87].”
Gemperle, F., Kasabach, C., Stivoric, J., Bauer, M., & Martin, R. (2002) · Digest of Papers. Second International Symposium on Wearable Computers (Cat. No.98EX215) · doi:10.1109/iswc.1998.729537 · Cited by 451
Path Control: A Method for Patient-Cooperative Robot-Aided Gait Rehabilitation
Duschau-Wicke, A., von Zitzewitz, J., Caprez, A., Lunenburger, L., & Riener, R. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2033061 · Cited by 421 · cited 1×
“Microsoft Kinect [11, 12]); 4) Robot-based solutions [13, 14]; 5) wearable sensor-based systems [4].”
Advances in wearable technology and applications in physical medicine and rehabilitation
Bonato, P. (2005) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-2-2 · Cited by 385
Review of fall risk assessment in geriatric populations using inertial sensors
Howcroft, J., Kofman, J., & Lemaire, E. D. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-91 · Cited by 377
van Kuijk, A. A., Bakker, C. D., Hendriks, J. C., Geurts, A. C., Stegeman, D. F., & Pasman, J. W. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-1 · Cited by 373
The use of inertial sensors system for human motion analysis
Cuesta-Vargas, A. I., Galán-Mercant, A., & Williams, J. M. (2010) · Physical Therapy Reviews · doi:10.1179/1743288x11y.0000000006 · Cited by 369 · cited 1×
“[30] reviewed inertial sensors applied in human motion analysis, and concluded that inertial sensors can offer a task-specific accurate and reliable method for human motion studies.”
A Review on Technical and Clinical Impact of Microsoft Kinect on Physical Therapy and Rehabilitation
Mousavi Hondori, H., & Khademi, M. (2014) · Journal of Medical Engineering · doi:10.1155/2014/846514 · Cited by 360
Extrinsic feedback for motor learning after stroke: What is the evidence?
van Vliet, P. M., & Wulf, G. (2006) · Disability and Rehabilitation · doi:10.1080/09638280500534937 · Cited by 354 · cited 1×
“System feedback Feedback is important for rehabilitation training, for supporting the motor learning process in musculoskeletal and neurological pathologies [8, 33], and for sustaining motivation during rehabilitation [7].”
Johnson, A. N., Huo, X., Ghovanloo, M., & Shinohara, M. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-1 · Cited by 321
Fong, D. T.-P., & Chan, Y.-Y. (2010) · Sensors · doi:10.3390/s101211556 · Cited by 286
Sjölander, P., Michaelson, P., Jaric, S., & Djupsjöbacka, M. (2008) · Manual Therapy · doi:10.1016/j.math.2006.10.002 · Cited by 280
Concurrent neuromechanical and functional gains following upper-extremity power training post-stroke
Patten, C., Condliffe, E. G., Dairaghi, C. A., & Lum, P. S. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-1 · Cited by 259
Uswatte, G., Giuliani, C., Winstein, C., Zeringue, A., Hobbs, L., & Wolf, S. L. (2006) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2006.06.006 · Cited by 241 · cited 1×
“[21] conducted a validation study of accelerometry for monitoring arm activity of stroke patients.”
Devendorf, L., Lo, J., Howell, N., Lee, J. L., Gong, N.-W., Karagozler, M. E., Fukuhara, S., Poupyrev, I., Paulos, E., & Ryokai, K. (2016) · Proceedings of the 2016 CHI Conference on Human Factors in Computing Systems · doi:10.1145/2858036.2858192 · Cited by 235
Seymour, S. (2008) · Springer eBooks · doi:10.1007/978-3-211-74500-7 · Cited by 215
26th Annual International Conference of the IEEE EMBS
Wang, L., Hammond, P., Johannessen, E. A., Tang, T. B., Astaras, A., Beaumont, S., Murray, A., Cooper, J. M., & Cumming, D. R. S. (2004) · Cited by 211
Subramanian, S. K., Massie, C. L., Malcolm, M. P., & Levin, M. F. (2010) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968309349941 · Cited by 206
Clinical Applications of Sensors for Human Posture and Movement Analysis: A Review
Wong, W. Y., Wong, M. S., & Lo, K. H. (2007) · Prosthetics & Orthotics International · doi:10.1080/03093640600983949 · Cited by 193 · cited 1×
“Discussion of wearable-sensing technologies Advanced technologies have been developed and applied to solve the relevant application problems [27].”
Friedman, N., Chan, V., Reinkensmeyer, A. N., Beroukhim, A., Zambrano, G. J., Bachman, M., & Reinkensmeyer, D. J. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-76 · Cited by 182
Obituary: Yukio Mano (1943–2004)
Ikoma, K. (2005) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-2-1 · Cited by 173
Assessment of hand kinematics using inertial and magnetic sensors
Kortier, H. G., Sluiter, V. I., Roetenberg, D., & Veltink, P. H. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-70 · Cited by 173
Wireless sensor networks for rehabilitation applications: Challenges and opportunities
Hadjidj, A., Souil, M., Bouabdallah, A., Challal, Y., & Owen, H. (2013) · Journal of Network and Computer Applications · doi:10.1016/j.jnca.2012.10.002 · Cited by 163
Musculoskeletal Rehabilitation in Osteoporosis: A Review
Pfeifer, M., Sinaki, M., Geusens, P., Boonen, S., Preisinger, E., Minne, H. W., & for the ASBMR Working Group on Musculoskeletal Rehabilitation (2004) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.040507 · Cited by 157
Textile Pressure Sensor for Muscle Activity and Motion Detection
Meyer, J. T., Lukowicz, P., & Tröster, G. (2006) · Proceedings · doi:10.1109/iswc.2006.286346 · Cited by 155
An Accelerometry-Based Methodology for Assessment of Real-World Bilateral Upper Extremity Activity
Bailey, R. R., Klaesner, J. W., & Lang, C. E. (2014) · PLoS ONE · doi:10.1371/journal.pone.0103135 · Cited by 148
Noorkõiv, M., Rodgers, H., & Price, C. I. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-144 · Cited by 141
Wearable Systems for Monitoring Mobility-Related Activities in Chronic Disease: A Systematic Review
Allet, L., Knols, R. H., Shirato, K., & Bruin, E. D. D. (2010) · Sensors · doi:10.3390/s101009026 · Cited by 118
Timmermans, A. A. A., Seelen, H. A. M., Geers, R. P. J., Saini, P. K., Winter, S., Vrugt, J. T., & Kingma, H. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2047608 · Cited by 102
Self-citationThe Manumeter: A Wearable Device for Monitoring Daily Use of the Wrist and Fingers
Friedman, N., Rowe, J. B., Reinkensmeyer, D. J., & Bachman, M. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2329841 · Cited by 100
Cancela, J., Pastorino, M., Tzallas, A., Tsipouras, M., Rigas, G., Arredondo, M., & Fotiadis, D. (2014) · Sensors · doi:10.3390/s140917235 · Cited by 97 · cited 1×
“In this respect, the study by Cancela et al. [90] is an inspiring example, where the Comfort Rating Scale was used to assess perceived exertion and physiological and biomechanical parameters were assessed to measure musculoskeletal loading.”
A novel array of flex sensors for a goniometric glove
Saggio, G. (2013) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2013.10.030 · Cited by 93
E-textiles in Clinical Rehabilitation: A Scoping Review
Fleury, A., Sugar, M., & Chau, T. T. (2015) · Electronics · doi:10.3390/electronics4010173 · Cited by 83
Unrestrained Measurement of Arm Motion Based on a Wearable Wireless Sensor Network
Lee, G. X., Low, K. S., & Taher, T. (2010) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2010.2043974 · Cited by 82
Tsekleves, E., Paraskevopoulos, I. T., Warland, A., & Kilbride, C. (2014) · Disability and Rehabilitation Assistive Technology · doi:10.3109/17483107.2014.981874 · Cited by 77
Reducing compensatory motions in video games for stroke rehabilitation
Alankuş, G., & Kelleher, C. L. (2012) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/2207676.2208354 · Cited by 75
Spina, G., Huang, G., Vaes, A. W., Spruit, M. A., & Amft, O. (2013) · ACM International Joint Conference on Pervasive and Ubiquitous Computing (UbiComp) · doi:10.1145/2493432.2493454 · Cited by 74
Timmermans, A. A. A., Verbunt, J., van Woerden, R., Moennekens, M., Pernot, D., & Seelen, H. A. M. (2012) · Journal of the American Medical Directors Association · doi:10.1016/j.jamda.2012.10.010 · Cited by 73
Self-citationSpatially distributed tactile feedback for kinesthetic motion guidance
Kapur, P., Jensen, M., Buxbaum, L. J., Jax, S. A., & Kuchenbecker, K. J. (2010) · 2010 IEEE Haptics Symposium · doi:10.1109/haptic.2010.5444606 · Cited by 72
Steins, D., Dawes, H., Esser, P., & Collett, J. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-36 · Cited by 71
Newbold, J. W., Bianchi‐Berthouze, N., Gold, N., Tajadura‐Jiménez, A., & Williams, A. C. D. C. (2016) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/2858036.2858302 · Cited by 67
Recognizing Complex Upper Extremity Activities Using Body Worn Sensors
Lemmens, R. J. M., Janssen‐Potten, Y., Timmermans, A. A. A., Smeets, R., & Seelen, H. A. M. (2015) · PLoS ONE · doi:10.1371/journal.pone.0118642 · Cited by 63
Self-citationA review of e-textiles in neurological rehabilitation: How close are we?
McLaren, R., Joseph, F., Baguley, C., & Taylor, D. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0167-0 · Cited by 62
A personalized exercise trainer for the elderly
Bleser, G., Steffen, D., Weber, M., Hendeby, G., Stricker, D., Fradet, L., Marin, F., Ville, N., & Carré, F. (2013) · Journal of Ambient Intelligence and Smart Environments · doi:10.3233/ais-130234 · Cited by 54
Motivating arm-hand use for stroke patients by serious games.
Delbressine, F. L. M., Timmermans, A. A. A., Beursgens, L., de Jong, M., van Dam, A., Verweij, D., Janssen, M., & Markopoulos, P. (2012) · PubMed · doi:10.1109/embc.2012.6346736 · Cited by 53
Self-citationBeer, A., Treleaven, J. M., & Jull, G. A. (2012) · Manual Therapy · doi:10.1016/j.math.2011.12.005 · Cited by 52
Inertia sensor-based guidance system for upperlimb posture correction
Ding, Z. Q., Luo, Z., Causo, A., Chen, I., Yue, K. X., Yeo, S. H., & Ling, K. V. (2011) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.09.002 · Cited by 52
Dunne, A., Do-Lenh, S., OLaighin, G. M., Shen, C., & Bonato, P. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626724 · Cited by 48
Extrinsic feedback and management of low back pain: A critical review of the literature
Ribeiro, D. C., Sole, G., Abbott, J. H., & Milosavljevic, S. (2011) · Manual Therapy · doi:10.1016/j.math.2010.12.001 · Cited by 47
ArmSleeve: A Patient Monitoring System to Support Occupational Therapists in Stroke Rehabilitation
Ploderer, B., Fong, J., Withana, A., Klaic, M., Nair, S., Crocher, V., Vetere, F., & Nanayakkara, S. (2016) · Proceedings of the 2016 ACM Conference on Designing Interactive Systems · doi:10.1145/2901790.2901799 · Cited by 46
Tormene, P., Bartolo, M., Nunzio, A. M. D., Fecchio, F., Quaglini, S., Tassorelli, C., & Sandrini, G. (2012) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-11-95 · Cited by 41
Bittel, A. J., Elazzazi, A. M., & Bittel, D. C. (2015) · Telemedicine Journal and e-Health · doi:10.1089/tmj.2015.0063 · Cited by 40
Markopoulos, P., Timmermans, A. A. A., Beursgens, L., van Donselaar, R., & Seelen, H. A. M. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091283 · Cited by 40
Self-citationParker, J., Mawson, S., Mountain, G., Nasr, N., & Zheng, H. (2014) · BMC Medical Informatics and Decision Making · doi:10.1186/1472-6947-14-46 · Cited by 40
Smartphone-Based Tele-Rehabilitation System for Frozen Shoulder Using a Machine Learning Approach
Ongvisatepaiboon, K., Chan, J. H., & Vanijja, V. (2015) · IEEE Symposium Series on Computational Intelligence (SSCI) · doi:10.1109/ssci.2015.120 · Cited by 40
Literature review on wearable systems in upper extremity rehabilitation
Wang, Q., Chen, W., & Markopoulos, P. (2014) · IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI ...) · doi:10.1109/bhi.2014.6864424 · Cited by 39
Self-citation(2010) · doi:10.1109/haptics16778.2010 · Cited by 37
Novel Smart Glove Technology as a Biomechanical Monitoring Tool
O’Flynn, B., Sachez, J., Tedesco, S. A., Downes, B., Connolly, J., Condell, J. V., & Curran, K. (2015) · Cork Open Research Archive (University College Cork, Ireland) · Cited by 35
A wireless-based home rehabilitation system for monitoring 3D movements
Daponte, P., Vito, L. D., & Sementa, C. (2013) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2013.6549753 · Cited by 25
Animation of 3D Avatars for Rehabilitation of the Upper Limbs
Moya, S., Grau, S., Tost, D., Campeny, R., & Ruiz, M. (2011) · International Conference on Games and Virtual Worlds for Serious Applications · doi:10.1109/vs-games.2011.32 · Cited by 21
An interactive therapy system for arm and hand rehabilitation
Luo, Z., Lim, C. K., Yang, W.-T., Tee, K. L., Li, K., Gu, C., Nguen, K. D., Chen, I., & Yeo, S. H. (2010) · IEEE Conference on Robotics, Automation and Mechatronics (RAM) · doi:10.1109/ramech.2010.5513222 · Cited by 19
Tetteroo, D., Timmermans, A. A. A., Seelen, H. A. M., & Markopoulos, P. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-140 · Cited by 18
Self-citationVigour: Smart textile services to support rehabilitation
ten Bhömer, M., Tomico, O., & Hummels, C. (2013) · Nordic design research conference · doi:10.21606/nordes.2013.084 · Cited by 17
Holden, A., McNaney, R., Balaam, M., Thompson, R. J., Hammerla, N., Plötz, T., Jackson, D., Price, C., Brkic, L., & Olivier, P. L. (2015) · British HCI Conference · doi:10.1145/2783446.2783576 · Cited by 17
Helping-Hand: A data glove technology for rehabilitation of monoplegia patients
Rahman, Y. A., Hoque, M. M., Apu, K. I. Z., & Bokhary, I. M. (2014) · International Forum on Strategic Technology · doi:10.1109/ifost.2014.6991104 · Cited by 13
Vibrotactile Cueing using Wearable Computers for Overcoming Learned Non-Use in Chronic Stroke
Luster, E., McDaniel, T. L., Fakhri, B., Davis, J., Goldberg, M., Bala, S., & Panchanathan, S. (2013) · Proceedings of the ICTs for improving Patients Rehabilitation Research Techniques · doi:10.4108/icst.pervasivehealth.2013.252351 · Cited by 10
Development of holistic physical therapy management system using multimodal sensor network
Wai, A. A. P., Biswas, J., Fook, F. S., Kenneth, L. J. H., Panda, S. K., & Yap, P. L. K. (2010) · International Conference on PErvasive Technologies Related to Assistive Environments (PETRA) · doi:10.1145/1839294.1839325 · Cited by 8
Rehabilitation and motor learning through Vibrotactile feedback
Panchanathan, R. S., Rosenthal, J., & McDaniel, T. L. (2014) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2050204 · Cited by 7
Mirrorcle: Enhanced Visual Feedback to support Motor Learning in Low Back Pain
Burghoorn, A. W., Dhaeze, E. R., Faber, J. S., Wories, J. W. H., Feijs, L. M. G., & Timmermans, A. A. A. (2015) · Workshop on ICTs for improving Patients Rehabilitation Research Techniques (REHAB) · doi:10.1145/2838944.2838951 · Cited by 5
Self-citationRehApp – A Wearable Haptic System for Rehabilitation and Sports Training
Myllymaa, K., Raisamo, R., Lylykangas, J., Heikkinen, J., & Surakka, V. (2012) · Lecture notes in computer science · doi:10.1007/978-3-642-31404-9_38 · Cited by 4
Cited by
Wearable health devices in health care: narrative systematic review
Lu, L., Zhang, J., Xie, Y., Gao, F., Xu, S., Wu, X., & Ye, Z. (2020) · JMIR mHealth and uHealth · doi:10.2196/18907 · Cited by 701
Duan, L., D'hooge, D. R., & Cardon, L. (2020) · Progress in Materials Science · doi:10.1016/j.pmatsci.2019.100617 · Cited by 554
Wireless battery-free body sensor networks using near-field-enabled clothing
Lin, R., Kim, H.-J., Achavananthadith, S., Kurt, S. A., Tan, S. C. C., Yao, H., Tee, B. C. K., Lee, J. K. W., & Ho, J. S. (2020) · Nature Communications · doi:10.1038/s41467-020-14311-2 · Cited by 331
Systematic Review on Kinematic Assessments of Upper Limb Movements After Stroke
Schwarz, A., Kanzler, C. M., Lambercy, O., Luft, A. R., & Veerbeek, J. M. (2019) · Stroke · doi:10.1161/strokeaha.118.023531 · Cited by 313
Zhang, Q., Xin, C., Shen, F., Gong, Y., Zi, Y., Guo, H., Li, Z., Peng, Y., Zhang, Q., & Wang, Z. L. (2022) · Energy & Environmental Science · doi:10.1039/d2ee01590k · Cited by 239
Metadata
- Authors
- Wang, Q., Markopoulos, P., Yu, B., Chen, W., & Timmermans, A.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2017-03-11
- Volume
- 14
- Issue
- 1
- Pages
- 20-20
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W2591746674
- Cited by
- 348
- References
- 85
- FWCI
- 6.67
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.