Measuring intracranial pressure by invasive, less invasive or non-invasive means: limitations and avenues for improvement
Open accessThe DOI matches its Crossref record; 133 of the 133 references it cites were found in a registry or an index.
Abstract
Sixty years have passed since neurosurgeon Nils Lundberg presented his thesis about intracranial pressure (ICP) monitoring, which represents a milestone for its clinical introduction. Monitoring of ICP has since become a clinical routine worldwide, and today represents a cornerstone in surveillance of patients with acute brain injury or disease, and a diagnostic of individuals with chronic neurological disease. There is, however, controversy regarding indications, clinical usefulness and the clinical role of the various ICP scores. In this paper, we critically review limitations and weaknesses with the current ICP measurement approaches for invasive, less invasive and non-invasive ICP monitoring. While risk related to the invasiveness of ICP monitoring is extensively covered in the literature, we highlight other limitations in current ICP measurement technologies, including limited ICP source signal quality control, shifts and drifts in zero pressure reference level, affecting mean ICP scores and mean ICP-derived indices. Control of the quality of the ICP source signal is particularly important for non-invasive and less invasive ICP measurements. We conclude that we need more focus on mitigation of the current limitations of today’s ICP modalities if we are to improve the clinical utility of ICP monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guidelines for the Management of Severe Traumatic Brain Injury, Fourth Edition
Carney, N., Totten, A. M., O'Reilly, C., Ullman, J. S., Hawryluk, G. W. J., Bell, M. J., Bratton, S. L., Chesnut, R., Harris, O. A., Kissoon, N., et al. (2017) · Neurosurgery · doi:10.1227/neu.0000000000001432 · Cited by 4,357
Noninvasive transcranial Doppler ultrasound recording of flow velocity in basal cerebral arteries
Aaslid, R., Markwalder, T.-M., & Nornes, H. (1982) · Journal of Neurosurgery · doi:10.3171/jns.1982.57.6.0769 · Cited by 3,046
Cerebral autoregulation dynamics in humans.
Aaslid, R., Lindegaard, K. F., Sorteberg, W., & Nornes, H. (1989) · Stroke · doi:10.1161/01.str.20.1.45 · Cited by 1,632
A Trial of Intracranial-Pressure Monitoring in Traumatic Brain Injury
Chesnut, R. M., Temkin, N., Carney, N., Dikmen, S., Rondina, C., Videtta, W., Petroni, G., Lujan, S., Pridgeon, J., Barber, J., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1207363 · Cited by 1,352
Continuous Recording and Control of Ventricular Fluid Pressure in Neurosurgical Practice
Lundberg, N. (1962) · Journal of Neuropathology and Experimental Neurology · doi:10.1097/00005072-196207000-00018 · Cited by 1,089 · cited 1×
“B waves Lundberg differentiated between three types of static ICP elevations, namely A, B and C waves [13].”
BackgroundThe Monro–Kellie hypothesis: Applications in CSF volume depletion
Mokri, B. (2001) · Neurology · doi:10.1212/wnl.56.12.1746 · Cited by 1,022
Bioresorbable silicon electronic sensors for the brain
Kang, S.-K., Murphy, R. K. J., Hwang, S.-W., Lee, S. M., Harburg, D. V., Krueger, N. A., Shin, J., Gamble, P., Cheng, H., Yu, S., et al. (2016) · Nature · doi:10.1038/nature16492 · Cited by 998
Cerebral perfusion pressure: management protocol and clinical results
Rosner, M. J., Rosner, S. D., & Johnson, A. H. (1995) · Journal of Neurosurgery · doi:10.3171/jns.1995.83.6.0949 · Cited by 963
Continuous Assessment of the Cerebral Vasomotor Reactivity in Head Injury
Czosnyka, M., Smielewski, P., Kirkpatrick, P., Laing, R. J., Menon, D., & Pickard, J. D. (1997) · Neurosurgery · doi:10.1097/00006123-199707000-00005 · Cited by 923
Monitoring and interpretation of intracranial pressure
Czosnyka, M. (2004) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2003.033126 · Cited by 794
Compartmental analysis of compliance and outflow resistance of the cerebrospinal fluid system
Marmarou, A., Shulman, K., & LaMorgese, J. (1975) · Journal of Neurosurgery · doi:10.3171/jns.1975.43.5.0523 · Cited by 725
A nonlinear analysis of the cerebrospinal fluid system and intracranial pressure dynamics
Marmarou, A., Shulman, K., & Rosende, R. M. (1978) · Journal of Neurosurgery · doi:10.3171/jns.1978.48.3.0332 · Cited by 586
The pulsating brain: A review of experimental and clinical studies of intracranial pulsatility
Wagshul, M. E., Eide, P. K., & Madsen, J. R. (2011) · Fluids and Barriers of the CNS · doi:10.1186/2045-8118-8-5 · Cited by 473
Self-citationLe Roux, P., Menon, D. K., Citerio, G., Vespa, P., Bader, M. K., Brophy, G. M., Diringer, M. N., Stocchetti, N., Videtta, W., Armonda, R., et al. (2014) · Neurocritical Care · doi:10.1007/s12028-014-0041-5 · Cited by 467
Transcranial Doppler Ultrasound: Technique and Application
Purkayastha, S., & Sorond, F. (2013) · Seminars in Neurology · doi:10.1055/s-0032-1331812 · Cited by 431
Katzman, R., & Hussey, F. (1970) · Neurology · doi:10.1212/wnl.20.6.534 · Cited by 419
Intracranial Pressure Monitoring: Invasive versus Non-Invasive Methods—A Review
Raboel, P. H., Bartek, J., Andresen, M., Bellander, B. M., & Romner, B. (2012) · Critical Care Research and Practice · doi:10.1155/2012/950393 · Cited by 416
Cerebral vasomotor paralysis produced by intracranial hypertension
Langfitt, T. W., Weinstein, J. D., & Kassell, N. F. (1965) · Neurology · doi:10.1212/wnl.15.7.622 · Cited by 409
The Insertion and Management of External Ventricular Drains: An Evidence-Based Consensus Statement
Fried, H., Nathan, B. R., Rowe, A. S., Zabramski, J. M., Andaluz, N. O., Bhimraj, A., Guanci, M. M., Seder, D. B., & Singh, J. M. (2016) · Neurocritical Care · doi:10.1007/s12028-015-0224-8 · Cited by 401
Alperin, N. J., Lee, S. H., Loth, F., Raksin, P. B., & Lichtor, T. (2000) · Radiology · doi:10.1148/radiology.217.3.r00dc42877 · Cited by 327
Continuous recording and control of ventricular fluid pressure in neurosurgical practice.
Lundberg, N. (1960) · PubMed · Cited by 321
Cerebrospinal fluid pulse pressure and intracranial volume-pressure relationships.
Avezaat, C. J., van Eijndhoven, J. H., & Wyper, D. J. (1979) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.42.8.687 · Cited by 311
(2007) · Journal of Neurotrauma · doi:10.1089/neu.2007.9999 · Cited by 297
Geeraerts, T., Newcombe, V. F., Coles, J. P., Abate, M. G., Perkes, I. E., Hutchinson, P. J., Outtrim, J. G., Chatfield, D. A., & Menon, D. K. (2008) · Critical Care · doi:10.1186/cc7006 · Cited by 296
Badri, S., Chen, J., Barber, J. K., Temkin, N. R., DIKMEN, S. S., Chesnut, R. M., Deem, S. A., Yanez, N. D., & Treggiari, M. M. (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2655-4 · Cited by 293
Cerebral Near-Infrared Spectroscopy in Adults: A Work in Progress
Ghosh, A., Elwell, C., & Smith, M. (2012) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31826dd6a6 · Cited by 277
Complications of intracranial pressure monitoring in fulminant hepatic failure
Blei, A. T., Olafsson, S., Webster, S., & Levy, R. (1993) · The Lancet · doi:10.1016/0140-6736(93)90016-a · Cited by 270
Shin, J., Yan, Y., Bai, W., Xue, Y., Gamble, P., Tian, L., Kandela, I., Haney, C. R., Spees, W., Lee, Y., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0300-4 · Cited by 263
Eide, P. K., & Sorteberg, W. (2010) · Neurosurgery · doi:10.1227/01.neu.0000363408.69856.b8 · Cited by 259
Self-citationHeuer, G. G., Smith, M. J., Elliott, J. P., Winn, H. R., & Leroux, P. D. (2004) · Journal of Neurosurgery · doi:10.3171/jns.2004.101.3.0408 · Cited by 238
Invasive and noninvasive means of measuring intracranial pressure: a review
Zhang, X., Medow, J. E., Iskandar, B. J., Wang, F., Shokoueinejad, M., Koueik, J., & Webster, J. G. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa7256 · Cited by 233
Analysis of the cerebrospinal fluid pulse wave in intracranial pressure
Cardoso, E. R., Rowan, J. O., & Galbraith, S. (1983) · Journal of Neurosurgery · doi:10.3171/jns.1983.59.5.0817 · Cited by 232
Shapiro, K., Marmarou, A., & Shulman, K. (1980) · Annals of Neurology · doi:10.1002/ana.410070603 · Cited by 228
Farahvar, A., Gerber, L. M., Chiu, Y.-L., Carney, N., Härtl, R., & Ghajar, J. (2012) · Journal of Neurosurgery · doi:10.3171/2012.7.jns111816 · Cited by 226
Complications of invasive intracranial pressure monitoring devices in neurocritical care
Tavakoli, S., Peitz, G. W., Ares, W. J., Hafeez, S., & Grandhi, R. (2017) · Neurosurgical FOCUS · doi:10.3171/2017.8.focus17450 · Cited by 224
Continuous monitoring of cerebrovascular pressure reactivity in patients with head injury
Zweifel, C., Lavinio, A., Steiner, L. A., Radolovich, D., Smielewski, P., Timofeev, I., Hiler, M., Balestreri, M., Kirkpatrick, P. J., Pickard, J. D., et al. (2008) · Neurosurgical Focus · doi:10.3171/foc.2008.25.10.e2 · Cited by 216
Intracranial Pressure Monitoring in Brain-Injured Patients is Associated With Worsening of Survival
Shafi, S., Diaz-Arrastia, R., Madden, C., & Gentilello, L. (2008) · Journal of Trauma: Injury, Infection & Critical Care · doi:10.1097/ta.0b013e31815dd017 · Cited by 213
Intracranial Pressure Monitoring—Review and Avenues for Development
Harary, M., Dolmans, R. G. F., & Gormley, W. B. (2018) · Sensors · doi:10.3390/s18020465 · Cited by 210
Intracranial pressure and cerebrospinal fluid outflow conductance in healthy subjects
Albeck, M. J., Børgesen, S. E., Gjerris, F., Schmidt, J. F., & Sørensen, P. S. (1991) · Journal of Neurosurgery · doi:10.3171/jns.1991.74.4.0597 · Cited by 208
Chronically implanted pressure sensors: challenges and state of the field
Yu, L., Kim, B., & Meng, E. (2014) · Sensors · doi:10.3390/s141120620 · Cited by 200
Significance of intracranial pressure waveform analysis after head injury
Czosnyka, M., Guazzo, E., Whitehouse, M., Smielewski, P., Czosnyka, Z., Kirkpatrick, P., Piechnik, S., & Pickard, J. D. (1996) · Acta Neurochirurgica · doi:10.1007/bf01411173 · Cited by 185
Balestreri, M., Czosnyka, M., Steiner, L. A., Schmidt, E., Smielewski, P., Matta, B., & Pickard, J. D. (2004) · Acta Neurochirurgica · doi:10.1007/s00701-003-0187-y · Cited by 172
Non-invasive assessment of intracranial pressure
Robba, C., Bacigaluppi, S., Cardim, D., Donnelly, J., Bertuccio, A., & Czosnyka, M. (2016) · Acta Neurologica Scandinavica · doi:10.1111/ane.12527 · Cited by 166
The Camino intracranial pressure device in clinical practice. Assessment in a 1000 cases
Gelabert-González, M., Ginesta-Galan, V., Sernamito-García, R., Allut, A. G., Bandin-Diéguez, J., & Rumbo, R. M. (2006) · Acta Neurochirurgica · doi:10.1007/s00701-005-0683-3 · Cited by 163
Donnelly, J., Czosnyka, M., Adams, H., Cardim, D., Kolias, A. G., Zeiler, F. A., Lavinio, A., Aries, M., Robba, C., Smielewski, P., et al. (2019) · Neurosurgery · doi:10.1093/neuros/nyy468 · Cited by 160
Selection of instrumentation and fusion levels for scoliosis: where to start and where to stop
Bridwell, K. H. (2004) · Journal of Neurosurgery Spine · doi:10.3171/spi.2004.1.1.0001 · Cited by 151
Cnossen, M. C., Huijben, J. A., van der Jagt, M., Volovici, V., van Essen, T. A., Polinder, S., Nelson, D., Ercole, A., Stocchetti, N., Citerio, G., et al. (2017) · Critical Care · doi:10.1186/s13054-017-1816-9 · Cited by 150
Advances in ICP monitoring techniques
Zhong, J., Dujovny, M., Park, H. K., Perez, E., Perlin, A. R., & Diaz, F. G. (2003) · Neurological Research · doi:10.1179/016164103101201661 · Cited by 148
Sahuquillo, J., Poca, M. A., Arribas, M., Garnacho, A., & Rubio, E. (1999) · Journal of neurosurgery · doi:10.3171/jns.1999.90.1.0016 · Cited by 146
Measurement of intracranial pressure in children: a critical review of current methods
Wiegand, C., & Richards, P. (2007) · Developmental Medicine & Child Neurology · doi:10.1111/j.1469-8749.2007.00935.x · Cited by 139
Miller, M. T., Pasquale, M. D., Kurek, S. J., White, J., Martin, P., Bannon, K., Wasser, T., & Li, M. (2004) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/01.ta.0000123699.16465.8b · Cited by 139
Transcranial Doppler Pulsatility Index: Not an Accurate Method to Assess Intracranial Pressure
Behrens, A., Lenfeldt, N., Ambarki, K., Malm, J., Eklund, A., & Koskinen, L. (2010) · Neurosurgery · doi:10.1227/01.neu.0000369519.35932.f2 · Cited by 135
Kashif, F. M., Verghese, G. C., Novak, V., Czosnyka, M., & Heldt, T. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3003249 · Cited by 131
Bouzat, P., Sala, N., Payen, J.-F., & Oddo, M. (2013) · Annals of Intensive Care · doi:10.1186/2110-5820-3-23 · Cited by 126
Koskinen, L., & Olivecrona, M. (2005) · Neurosurgery · doi:10.1227/01.neu.0000156609.95596.24 · Cited by 126
Bhatia, A., & Gupta, A. K. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0678-z · Cited by 125
Evaluation of a fiberoptic intracranial pressure monitor
Crutchfield, J. S., Narayan, R. K., ROBERTSON, C. S., & Michael, L. H. (1990) · Journal of neurosurgery · doi:10.3171/jns.1990.72.3.0482 · Cited by 124
Koziarz, A., Sne, N., Kegel, F., Nath, S., Badhiwala, J. H., Nassiri, F., Mansouri, A., Yang, K., Zhou, Q. X., Rice, T. J., et al. (2019) · Annals of Internal Medicine · doi:10.7326/m19-0812 · Cited by 120
Clinical assessment of noninvasive intracranial pressure absolute value measurement method
Ragauskas, A., Matijošaitis, V., Žakelis, R., Petrikonis, K., Rastenytė, D., Piper, I., & Daubaris, G. (2012) · Neurology · doi:10.1212/wnl.0b013e3182574f50 · Cited by 119
Clinical experience with a continuous monitor of intracranial compliance
Robertson, C. S., Narayan, R. K., Contant, C. F., Grossman, R. G., Gokaslan, Z. L., Pahwa, R., Caram, P. C., Bray, R. S., & Sherwood, A. M. (1989) · Journal of neurosurgery · doi:10.3171/jns.1989.71.5.0673 · Cited by 115
A new method for processing of continuous intracranial pressure signals
Eide, P. K. (2005) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2005.09.008 · Cited by 112 · cited 3×
“Automatic identification and characterization of single ICP waves represents a challenge that requires a dedicated methodology [101].”
BackgroundInfluentialSelf-citationCardim, D., Robba, C., Donnelly, J., Bohdanowicz, M., Schmidt, B. T., Damian, M. S., Varsos, G. V., Liu, X., Cabeleira, M. T., Frigieri, G. H., et al. (2015) · Journal of Neurotrauma · doi:10.1089/neu.2015.4134 · Cited by 110
Monitoring, T. P. I. T. I. M. C. C. O. M., Helbok, R., Olson, D. M., Roux, P. D. L., & Vespa, P. M. (2014) · Neurocritical Care · doi:10.1007/s12028-014-0040-6 · Cited by 108
Ryder, H. W., Espey, F. F., Kimbell, F. D., Penka, E. J., Rosenauer, A., PODOLSKY, B., & Evans, J. P. (1953) · PubMed · Cited by 106
What Shapes Pulse Amplitude of Intracranial Pressure?
Carrera, E., Kim, D., Castellani, G., Zweifel, C., Czosnyka, Z. H., Kasprowicz, M., Smielewski, P. S., Pickard, J. D., & Czosnyka, M. (2009) · Journal of Neurotrauma · doi:10.1089/neu.2009.0951 · Cited by 106
Chesnut, R. M., Bleck, T. P., Citerio, G., Classen, J., Cooper, D. J., Coplin, W. M., Diringer, M. N., Grände, P., Hemphill, J. C., Hutchinson, P. J., et al. (2015) · Journal of Neurotrauma · doi:10.1089/neu.2015.3976 · Cited by 105
Effect of postural changes on ICP in healthy and ill subjects
Andresen, M., Hadi, A., Petersen, L. G., & Juhler, M. (2014) · Acta Neurochirurgica · doi:10.1007/s00701-014-2250-2 · Cited by 104
Forecasting ICP Elevation Based on Prescient Changes of Intracranial Pressure Waveform Morphology
Hu, X., Xu, P. F., Asgari, S., Vespa, P. M., & Bergsneider, M. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2037607 · Cited by 100
Brain Multimodality Monitoring: Updated Perspectives
Roh, D. J., & Park, S. (2016) · Current Neurology and Neuroscience Reports · doi:10.1007/s11910-016-0659-0 · Cited by 96
Intracranial pressure wave morphological classification: automated analysis and clinical validation
Nucci, C. G., BONIS, P. D., Mangiola, A., Santini, P., Sciandrone, M., Risi, A., & Anile, C. (2016) · Acta Neurochirurgica · doi:10.1007/s00701-015-2672-5 · Cited by 89
Piper, I., Barnes, A., Smith, D. C., & Dunn, L. (2001) · Neurosurgery · doi:10.1097/00006123-200111000-00026 · Cited by 89 · cited 3×
“and is well established [48], but the magnitude of drift varies between studies [14, 81].”
BackgroundMethodAccuracy of intracranial pressure monitoring: systematic review and meta-analysis
Zacchetti, L., Magnoni, S., Corte, F. D., Zanier, E. R., & Stocchetti, N. (2015) · Critical Care · doi:10.1186/s13054-015-1137-9 · Cited by 86
Zeiler, F. A., Ercole, A., Cabeleira, M. T., Zoerle, T., Stocchetti, N., Menon, D. K., Smielewski, P. S., & Czosnyka, M. (2019) · Acta Neurochirurgica · doi:10.1007/s00701-019-03844-1 · Cited by 85
Raised intracranial pressure in acute viral encephalitis
Kumar, G., Kalita, J., & Misra, U. K. (2009) · Clinical Neurology and Neurosurgery · doi:10.1016/j.clineuro.2009.03.004 · Cited by 83
Eide, P. K., & Sorteberg, W. (2015) · World Neurosurgery · doi:10.1016/j.wneu.2015.09.067 · Cited by 79 · cited 2×
“Limitations Similar to ventricular catheter placement, the insertion of dedicated ICP sensors represents a risk for bleeds and infections [14, 59, 60].”
BackgroundMethodSelf-citationDevelopment of Clinically Relevant Implantable Pressure Sensors: Perspectives and Challenges
Clausen, I., & Glott, T. (2014) · Sensors · doi:10.3390/s140917686 · Cited by 78
The Relationship Between Intracranial Pressure and Age—Chasing Age-Related Reference Values
Pedersen, S. H., Lilja‐Cyron, A., Andresen, M., & Juhler, M. (2017) · World Neurosurgery · doi:10.1016/j.wneu.2017.10.086 · Cited by 78
Intracranial Pressure and Intracranial Elastance Monitoring in Neurocritical Care
Heldt, T., Zoerle, T., Teichmann, D., & Stocchetti, N. (2019) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-060418-052257 · Cited by 76
Eide, P. K., & Sorteberg, W. (2007) · Neurological Research · doi:10.1179/016164107x224132 · Cited by 73
Self-citationEide, P. K. (2003) · Acta Neurochirurgica · doi:10.1007/s00701-002-1062-y · Cited by 72
Self-citationKawoos, U., Gu, M., Lankasky, J., McCarron, R. M., & Chavko, M. (2016) · PLoS ONE · doi:10.1371/journal.pone.0167510 · Cited by 67
Czosnyka, M., Price, D. J., & Williamson, M. L. (1994) · Acta Neurochirurgica · doi:10.1007/bf01476419 · Cited by 65
Slow pressure waves in the cranial enclosure.
Lemaire, J., Khalil, T. A., Cervenansky, F., Gindre, G., Boire, J. Y., Bazin, J.-É., Irthum, B., & Chazal, J. (2002) · Acta Neurochirurgica · doi:10.1007/s007010200032 · Cited by 63
Kim, S., Hong, E. P., Kim, H. C., Lee, S. U., & Jeon, J. P. (2018) · Acta Radiologica · doi:10.1177/0284185118776501 · Cited by 62
Eide, P. K., Sorteberg, A. G., Bentsen, G., Marthinsen, P. B., Stubhaug, A., & Sorteberg, W. (2012) · Journal of neurosurgery · doi:10.3171/2012.1.jns111313 · Cited by 62
Self-citationNoninvasive Monitoring of Intracranial Pressure
Popovic, D. P., Khoo, M. C. K., & Lee, S. (2009) · Recent Patents on Biomedical Engineering · doi:10.2174/1874764710902030165 · Cited by 60
Voss, S. E., Horton, N. J., Tabucchi, T. H. P., Folowosele, F. O., & Shera, C. A. (2006) · Neurocritical Care · doi:10.1385/ncc:4:3:251 · Cited by 60
Rohlwink, U. K., Zwane, E. N., Fieggen, G. A. G., Argent, A. C., Roux, P. D. L., & Figaji, A. (2011) · Neurosurgery · doi:10.1227/neu.0b013e318243fc59 · Cited by 58
An evaluation of three measures of intracranial compliance in traumatic brain injury patients
Howells, T., Lewén, A., Sköld, M. K., Ronne-Engström, E., & Enblad, P. (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2571-7 · Cited by 58
Eide, P. K., & Sæhle, T. (2010) · Acta Neurochirurgica · doi:10.1007/s00701-010-0605-x · Cited by 53
Self-citationEide, P. K. (2016) · Journal of neurosurgery · doi:10.3171/2015.11.jns151529 · Cited by 53
Self-citationSpeck, V., Staykov, D., Huttner, H. B., Sauer, R., Schwab, S., & Bardutzky, J. (2010) · Neurocritical Care · doi:10.1007/s12028-010-9459-6 · Cited by 53
Hasan‐Olive, M. M., Enger, R., Hansson, H., Nagelhus, E. A., & Eide, P. K. (2019) · Fluids and Barriers of the CNS · doi:10.1186/s12987-019-0160-7 · Cited by 52
Self-citationRadio Telemetry for the Measurement of Intracranial Pressure
Atkinson, J. R., SHURTLEFF, D. B., & Foltz, E. L. (1967) · Journal of neurosurgery · doi:10.3171/jns.1967.27.5.0428 · Cited by 52
Hall, A., & O’Kane, R. (2016) · Acta Neurochirurgica · doi:10.1007/s00701-016-2932-z · Cited by 51
Yau, Y.-H., Piper, I., Clutton, R. E., & Whittle, I. R. (2000) · Journal of neurosurgery · doi:10.3171/jns.2000.93.6.1072 · Cited by 50
Eide, P. K., Bentsen, G., Sorteberg, A. G., Marthinsen, P. B., Stubhaug, A., & Sorteberg, W. (2011) · Neurosurgery · doi:10.1227/neu.0b013e318227e0e1 · Cited by 50
Self-citationDesign challenges of implantable pressure monitoring system
Jiang, G. (2010) · Frontiers in Neuroscience · doi:10.3389/neuro.20.002.2010 · Cited by 49
Eide, P. K. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.01.005 · Cited by 48
Self-citationIs intracranial pressure monitoring in the epidural space reliable? Fact and fiction
Poca, M. A., Sahuquillo, J., Topczewski, T. E., Peñarrubia, M. J., & Muns, A. (2007) · Journal of neurosurgery · doi:10.3171/jns.2007.106.4.548 · Cited by 47
Eide, P. K., & Brean, A. (2006) · British Journal of Neurosurgery · doi:10.1080/02688690601047312 · Cited by 46
Self-citationRecording of intracranial pressure in conscious rats via telemetry
Guild, S., McBryde, F. D., & Malpas, S. C. (2015) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00165.2015 · Cited by 45
Eide, P. K. (2005) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2005.09.003 · Cited by 44 · cited 3×
“However, depending on how ICP wave amplitudes are determined, these scores do not appear to be influenced by zero pressure levels [45, 90].”
BackgroundMethodInfluentialSelf-citationInvestigation of intracranial media ultrasonic monitoring model
Petkus, V., Ragauskas, A., & Jurkonis, R. (2002) · Ultrasonics · doi:10.1016/s0041-624x(02)00216-0 · Cited by 44
A comparison of extradural and intraparenchymatous intracranial pressures in head injured patients
Bruder, N. J., N’zoghe, P., Graziani, N., Pellissier, D., Grisoli, F., & François, G. (1995) · Intensive Care Medicine · doi:10.1007/bf01700971 · Cited by 44
Ringstad, G. A., Lindstrøm, E. K., Vatnehol, S. A. S., Mardal, K., Emblem, K. E., & Eide, P. K. (2017) · PLoS ONE · doi:10.1371/journal.pone.0188896 · Cited by 41
Self-citationBrain CT to Assess Intracranial Pressure in Patients with Traumatic Brain Injury
Pappu, S., Lerma, J., & Khraishi, T. A. (2015) · Journal of Neuroimaging · doi:10.1111/jon.12289 · Cited by 41
Intracranial pressure monitoring in acute liver failure. A procedure with clear indications
Wendon, J. A., & Larsen, F. S. (2006) · Hepatology · doi:10.1002/hep.21311 · Cited by 40 · cited 1×
“Non-TBI surveillance may also include systemic diseases such as acute liver failure, end-stage kidney failure, and hypertensive encephalopathy [23].”
BackgroundKohani, M., & PECHT, M. G. (2017) · IEEE Access · doi:10.1109/access.2017.2782088 · Cited by 40
Eftekhari, S., Westgate, C. S. J., Uldall, M., & Jensen, R. (2019) · Fluids and Barriers of the CNS · doi:10.1186/s12987-019-0155-4 · Cited by 39
Larsen, L., Poulsen, F. R., Nielsen, T. H., Nordström, C., Schulz, M. K., & Andersen, Å. B. (2017) · Scandinavian Journal of Infectious Diseases · doi:10.1080/23744235.2016.1269265 · Cited by 34
Pseudo-Bayesian Model-Based Noninvasive Intracranial Pressure Estimation and Tracking
Imaduddin, S. M., Fanelli, A., Vonberg, F. W., Tasker, R. C., & Heldt, T. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2940929 · Cited by 34
Eide, P. K. (2008) · Journal of neurosurgery · doi:10.3171/jns/2008/109/11/0912 · Cited by 33
Self-citationTelemetry in intracranial pressure monitoring: sensor survival and drift
Nørager, N. H., Lilja‐Cyron, A., Bjarkam, C. R., Gustafsen, S. D., & Juhler, M. (2018) · Acta Neurochirurgica · doi:10.1007/s00701-018-3691-9 · Cited by 33
Eide, P. K., & Bakken, A. (2011) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-10-75 · Cited by 32
Self-citationEide, P. K., Rapoport, B. I., Gormley, W. B., & Madsen, J. R. (2009) · Journal of neurosurgery · doi:10.3171/2009.7.jns081593 · Cited by 31 · cited 1×
“The BPEs may explain the abrupt shifts in the relationship between mean ICP and MWA that occur when monitoring ICP with only one ICP sensor [93].”
BackgroundSelf-citation(2001) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2001.1020357 · Cited by 31
Kawoos, U., McCarron, R. M., & Chavko, M. (2017) · Frontiers in Neurology · doi:10.3389/fneur.2017.00219 · Cited by 31
Brean, A., Eide, P. K., & Stubhaug, A. (2006) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-006-9047-7 · Cited by 29
Self-citationBrain Tissue Oxygenation and Cerebral Metabolic Patterns in Focal and Diffuse Traumatic Brain Injury
Purins, K., Lewén, A., Hillered, L., Howells, T., & Enblad, P. (2014) · Frontiers in Neurology · doi:10.3389/fneur.2014.00064 · Cited by 29
Can intracranial pressure be measured non-invasively bedside using a two-depth Doppler-technique?
Koskinen, L., Malm, J., Žakelis, R., Bartušis, L., Ragauskas, A., & Eklund, A. (2016) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-016-9862-4 · Cited by 28
Feasibility of Telemetric Intracranial Pressure Monitoring in the Neuro Intensive Care Unit
Lilja‐Cyron, A., Kelsen, J., Andresen, M., Fugleholm, K., & Juhler, M. (2018) · Journal of Neurotrauma · doi:10.1089/neu.2017.5589 · Cited by 28
Levinsky, A., Papyan, S., Weinberg, G., Stadheim, T., & Eide, P. K. (2016) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2016.02.009 · Cited by 25
Self-citationEvensen, K. B., O’Rourke, M., Prieur, F., Holm, S., & Eide, P. K. (2018) · Scientific Reports · doi:10.1038/s41598-018-23142-7 · Cited by 25
Self-citationSæhle, T., & Eide, P. K. (2015) · Acta Neurochirurgica · doi:10.1007/s00701-015-2410-z · Cited by 19
Self-citationA Spectral Approach to Model-Based Noninvasive Intracranial Pressure Estimation
Jaishankar, R., Fanelli, A., Filippidis, A., Vu, T., Holsapple, J. W., & Heldt, T. (2019) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2961403 · Cited by 18
Freimann, F. B., Sprung, C., Chopra, S., et al. (2013) · Pediatric Neurosurgery · doi:10.1159/000355561 · Cited by 16
Eide, P. K., Sroka, M., Woźniak, A., & Sæhle, T. (2011) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.11.011 · Cited by 14
Self-citationEide, P. K. (2011) · Fluids and Barriers of the CNS · doi:10.1186/2045-8118-8-11 · Cited by 13 · cited 1×
“On the other hand, the ICP wave amplitudes in individuals with iNPH were not related to cardiovascular parameters such as arterial blood pressure, cardiac output, stroke volume, oxygen consumption and systemic vascular resistance [110].”
Self-citationKim, M., Eide, P. K., O’Rourke, M. F., Adji, A. I., & Avolio, A. P. (2016) · Acta neurochirurgica. Supplementum · doi:10.1007/978-3-319-22533-3_12 · Cited by 13
Self-citationEide, P. K., & Sorteberg, W. (2013) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-12-14 · Cited by 11
Self-citationThe “Lund concept”: what it is and what it isn't
Nordström, C. (2007) · Intensive Care Medicine · doi:10.1007/s00134-006-0521-y · Cited by 9
Batteryless on-demand-sampling active radiosonde for intracranial pressure measurement
Macellari, V. (1981) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441329 · Cited by 8
Metadata
- Authors
- Evensen, K. B., & Eide, P. K.
- Venue
- Fluids and Barriers of the CNS
- Published
- 2020-05-06
- Volume
- 17
- Issue
- 1
- Pages
- 34-34
- ISSN
- 2045-8118 (ISSN-L)
- OpenAlex
- W3023459037
- Cited by
- 170
- References
- 133
- FWCI
- 7.33
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.