Abstract
Radiomics is an emerging translational field of research aiming to extract mineable high-dimensional data from clinical images. The radiomic process can be divided into distinct steps with definable inputs and outputs, such as image acquisition and reconstruction, image segmentation, features extraction and qualification, analysis, and model building. Each step needs careful evaluation for the construction of robust and reliable models to be transferred into clinical practice for the purposes of prognosis, non-invasive disease tracking, and evaluation of disease response to treatment. After the definition of texture parameters (shape features; first-, second-, and higher-order features), we briefly discuss the origin of the term radiomics and the methods for selecting the parameters useful for a radiomic approach, including cluster analysis, principal component analysis, random forest, neural network, linear/logistic regression, and other. Reproducibility and clinical value of parameters should be firstly tested with internal cross-validation and then validated on independent external cohorts. This article summarises the major issues regarding this multi-step process, focussing in particular on challenges of the extraction of radiomic features from data sets provided by computed tomography, positron emission tomography, and magnetic resonance imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538
Regression shrinkage and selection via the lasso
Tibshirani, R. (1996) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1996.tb02080.x · Cited by 51,482
Textural Features for Image Classification
Haralick, R. M., Shanmugam, K., & Dinstein, I. (1973) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1973.4309314 · Cited by 22,886 · cited 2×
“Second-order statistics features include the so-called textural features [5, 6], which are obtained calculating the statistical inter-relationships between neighbouring voxels [7].”
BackgroundRadiomics: Images Are More than Pictures, They Are Data
Gillies, R. J., Kinahan, P. E., & Hricak, H. (2016) · Radiology · doi:10.1148/radiol.2015151169 · Cited by 8,421
Radiomics: the bridge between medical imaging and personalized medicine
Lambin, P., Leijenaar, R. T. H., Deist, T. M., Peerlings, J., de Jong, E. E. C., van Timmeren, J., Sanduleanu, S., Larue, R. T. H. M., Even, A. J. G., Jochems, A., et al. (2017) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2017.141 · Cited by 5,688 · cited 1×
“Radiomics ’ analyses can be performed in tumour regions, metastatic lesions, as well as in normal tissues [2].”
BackgroundThe Cancer Imaging Archive (TCIA): Maintaining and Operating a Public Information Repository
Clark, K., Vendt, B., Smith, K., Freymann, J., Kirby, J., Koppel, P., Moore, S., Phillips, S., Maffitt, D., Pringle, M., et al. (2013) · Journal of Digital Imaging · doi:10.1007/s10278-013-9622-7 · Cited by 4,599 · cited 1×
“These images can be used as valuable sources for both hypothesis generating and validation purposes [26].”
BackgroundMore powerful procedures for multiple significance testing
Hochberg, Y., & Benjamini, Y. (1990) · Statistics in Medicine · doi:10.1002/sim.4780090710 · Cited by 2,715 · cited 1×
“The most common way to overcome the multiple testing problem is to use Bonferroni correction or the less conservative false discovery rate corrections [19].”
MethodRadiomics: the process and the challenges
Kumar, V., Gu, Y., Basu, S., Berglund, A., Eschrich, S. A., Schabath, M. B., Forster, K., Aerts, H. J. W. L., Dekker, A., Fenstermacher, D., et al. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.06.010 · Cited by 2,258 · cited 1×
“4) and not always feasible for radiomics ’ analysis, requiring very large data sets [46].”
BackgroundTexture analysis using gray level run lengths
Galloway, M. M. (1975) · Computer Graphics and Image Processing · doi:10.1016/s0146-664x(75)80008-6 · Cited by 2,141
Director's Challenge Consortium for the Molecular Classification of Lung Adenocarcinoma (2008) · Nature Medicine · doi:10.1038/nm.1790 · Cited by 1,190
Overview of deep learning in medical imaging
Suzuki, K. (2017) · Radiological Physics and Technology · doi:10.1007/s12194-017-0406-5 · Cited by 1,087
Machine Learning methods for Quantitative Radiomic Biomarkers
Parmar, C., Grossmann, P., Bussink, J., Lambin, P., & Aerts, H. J. W. L. (2015) · Scientific Reports · doi:10.1038/srep13087 · Cited by 1,019
The History of the Cluster Heat Map
Wilkinson, L., & Friendly, M. (2009) · The American Statistician · doi:10.1198/tas.2009.0033 · Cited by 932
Standards for PET Image Acquisition and Quantitative Data Analysis
Boellaard, R. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.057182 · Cited by 902
Measuring Computed Tomography Scanner Variability of Radiomics Features
Mackin, D., Fave, X., Zhang, L., Fried, D., Yang, J., Taylor, B., Rodriguez-Rivera, E., Dodge, C., Jones, A. K., & Court, L. (2015) · Investigative Radiology · doi:10.1097/rli.0000000000000180 · Cited by 651
Giger (2018) · doi:10.1016/j.jacr.2017.12.028 · Cited by 634
Region growing: a new approach
Hojjatoleslami, S. A., & Kittler, J. (1998) · IEEE Transactions on Image Processing · doi:10.1109/83.701170 · Cited by 559
Characterization of PET/CT images using texture analysis: the past, the present… any future?
Hatt, M., Tixier, F., Pierce, L., Kinahan, P. E., Le Rest, C. C., & Visvikis, D. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-016-3427-0 · Cited by 475
McCollough, C. H., Bakalyar, D., Bostani, M., Brady, S. L., Boedeker, K., Boone, J. M., Chen‐Mayer, H. H., Christianson, O. I., Leng, S., Li, B., et al. (2014) · PubMed · Cited by 384
Molecular Staging for Survival Prediction of Colorectal Cancer Patients
Eschrich, S., Yang, I., Bloom, G., Kwong, K. Y., Boulware, D., Cantor, A., Coppola, D., Kruhøffer, M., Aaltonen, L., Orntoft, T. F., et al. (2005) · Journal of Clinical Oncology · doi:10.1200/jco.2005.00.695 · Cited by 348
CT Radiogenomic Characterization of EGFR, K-RAS, and ALK Mutations in Non-Small Cell Lung Cancer
Rizzo, S., Petrella, F., Buscarino, V., De Maria, F., Raimondi, S., Barberis, M., Fumagalli, C., Spitaleri, G., Rampinelli, C., De Marinis, F., et al. (2016) · European Radiology · doi:10.1007/s00330-015-3814-0 · Cited by 270
Self-citationRadiomics-based Prognosis Analysis for Non-Small Cell Lung Cancer
Zhang, Y., Oikonomou, A., Wong, A., Haider, M. A., & Khalvati, F. (2017) · Scientific Reports · doi:10.1038/srep46349 · Cited by 269
Larue, R. T. H. M., van Timmeren, J. E., de Jong, E. E. C., Feliciani, G., Leijenaar, R. T. H., Schreurs, W. M. J., Sosef, M. N., Raat, F. H. P. J., van der Zande, F. H. R., Das, M., et al. (2017) · Acta Oncologica · doi:10.1080/0284186x.2017.1351624 · Cited by 262
Test–Retest Reproducibility Analysis of Lung CT Image Features
Balagurunathan, Y., Kumar, V., Gu, Y., Kim, J., Wang, H., Liu, Y., Goldgof, D. B., Hall, L. O., Korn, R., Zhao, B., et al. (2014) · Journal of Digital Imaging · doi:10.1007/s10278-014-9716-x · Cited by 259
Volumetric CT-based segmentation of NSCLC using 3D-Slicer
Velazquez, E. R., Parmar, C., Jermoumi, M., Mak, R. H., van Baardwijk, A., Fennessy, F. M., Lewis, J. H., De Ruysscher, D., Kikinis, R., Lambin, P., et al. (2013) · Scientific Reports · doi:10.1038/srep03529 · Cited by 240
Mayerhoefer, M. E., Szomolanyi, P., Jirak, D., Materka, A., & Trattnig, S. (2009) · Medical Physics · doi:10.1118/1.3081408 · Cited by 225
Medical Image Segmentation by Combining Graph Cuts and Oriented Active Appearance Models
Chen, X., Udupa, J. K., Bagci, U., Zhuge, Y., & Yao, J. (2012) · IEEE Transactions on Image Processing · doi:10.1109/tip.2012.2186306 · Cited by 207
Shiri, I., Rahmim, A., Ghaffarian, P., Geramifar, P., Abdollahi, H., & Bitarafan-Rajabi, A. (2017) · European Radiology · doi:10.1007/s00330-017-4859-z · Cited by 204
Test–Retest Data for Radiomics Feature Stability Analysis: Generalizable or Study-Specific?
van Timmeren, J. E., Leijenaar, R. T. H., van Elmpt, W., Wang, J., Zhang, Z., Dekker, A., & Lambin, P. (2016) · Tomography · doi:10.18383/j.tom.2016.00208 · Cited by 191
Sun, S., Bauer, C., & Beichel, R. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2171357 · Cited by 187
Individual tooth segmentation from CT images using level set method with shape and intensity prior
Gao, H., & Chae, O. (2010) · Pattern Recognition · doi:10.1016/j.patcog.2010.01.010 · Cited by 173
Nyflot, M. J., Yang, F., Byrd, D. W., Bowen, S. R., Sandison, G. A., & Kinahan, P. E. (2015) · Journal of medical imaging · doi:10.1117/1.jmi.2.4.041002 · Cited by 150
Madabhushi, A., & Udupa, J. K. (2006) · Medical Physics · doi:10.1118/1.2335487 · Cited by 138
Radiomics in Nuclear Medicine Applied to Radiation Therapy: Methods, Pitfalls, and Challenges
Reuzé, S., Schernberg, A., Orlhac, F., Sun, R., Chargari, C., Dercle, L., Deutsch, É., Buvat, I., & Robert, C. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2018.05.022 · Cited by 134
Panth, K. M., Leijenaar, R. T. H., Carvalho, S., Lieuwes, N. G., Yaromina, A., Dubois, L., & Lambin, P. (2015) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2015.06.013 · Cited by 133 · cited 1×
“For instance, smoking-related lung cancers differ from lung cancers in non-smokers [27].”
BackgroundRizzo, S., Botta, F., Raimondi, S., Origgi, D., Buscarino, V., Colarieti, A., Tomao, F., Aletti, G. D., Zanagnolo, V. L., Grande, M. D., et al. (2018) · European Radiology · doi:10.1007/s00330-018-5389-z · Cited by 131
Self-citationLee, H., Palm, J., Grimes, S. M., & Ji, H. P. (2015) · Genome Medicine · doi:10.1186/s13073-015-0226-3 · Cited by 126
Reuzé, S., Orlhac, F., Chargari, C., Nioche, C., Limkin, E., Riet, F., Escande, A., Haie-Meder, C., Dercle, L., Gouy, S., et al. (2017) · Oncotarget · doi:10.18632/oncotarget.17856 · Cited by 125
Altazi, B. A., Zhang, G. G., Fernandez, D. C., Montejo, M. E., Hunt, D., Werner, J., Biagioli, M. C., & Moros, E. G. (2017) · Journal of Applied Clinical Medical Physics · doi:10.1002/acm2.12170 · Cited by 122
Suzuki, K., Kohlbrenner, R. M., Epstein, M. L., Obajuluwa, A. M., Xu, J., & Hori, M. (2010) · Medical Physics · doi:10.1118/1.3395579 · Cited by 117
Huynh, E., Coroller, T. P., Narayan, V., Agrawal, V., Romano, J., Franco, I. “., Parmar, C., Hou, Y., Mak, R. H., & Aerts, H. J. W. L. (2017) · PLoS ONE · doi:10.1371/journal.pone.0169172 · Cited by 113
Solomon, J., Mileto, A., Nelson, R. C., Choudhury, K. R., & Samei, E. (2015) · Radiology · doi:10.1148/radiol.2015150892 · Cited by 108
Segmentation of lung lesions on CT scans using watershed, active contours, and Markov random field
Tan, Y., Schwartz, L. H., & Zhao, B. (2013) · Medical Physics · doi:10.1118/1.4793409 · Cited by 105
Radiomics in radiooncology – challenging the medical physicist
Peeken, J. C., Bernhofer, M., Wiestler, B., Goldberg, T., Cremers, D., Rost, B., Wilkens, J. J., Combs, S. E., & Nüsslin, F. (2018) · Physica Medica · doi:10.1016/j.ejmp.2018.03.012 · Cited by 98
The integration of PET-CT scans from different hospitals into radiotherapy treatment planning
Öllers, M., Bosmans, G., van Baardwijk, A. A. W., Dekker, A. L. A. J., Lambin, P., Teule, J., Thimister, W., Rhami, A., & Ruysscher, D. D. (2008) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2007.12.025 · Cited by 65
Automatic Graph Cut Segmentation of Lesions in CT Using Mean Shift Superpixels
Ye, X., Beddoe, G., & Slabaugh, G. (2010) · International Journal of Biomedical Imaging · doi:10.1155/2010/983963 · Cited by 62
Multi-stage Learning for Robust Lung Segmentation in Challenging CT Volumes
Sofka, M., Wetzl, J., Birkbeck, N., Zhang, J., Kohlberger, T., Kaftan, J. N., Declerck, J. M., & Zhou, S. K. (2011) · Lecture notes in computer science · doi:10.1007/978-3-642-23626-6_82 · Cited by 58
Rizzo, S. M. R., Kalra, M. K., Schmidt, B., Raupach, R., Maher, M. M., Blake, M. A., & Saini, S. (2005) · Radiology · doi:10.1148/radiol.2371041879 · Cited by 51 · cited 1×
“Furthermore, electronic density quantification expressed as Hounsfield Units may vary with the reconstruction al-gorithm [30] or scanner calibration.”
MethodSelf-citationDalal, T., Kalra, M. K., Rizzo, S., Schmidt, B. T., Suess, C., Flohr, T. G., Blake, M. A., & Saini, S. (2005) · Radiology · doi:10.1148/radiol.2362041565 · Cited by 50
Self-citationA Study on the Basic Criteria for Selecting Heterogeneity Parameters of F18-FDG PET Images
Forgács, A., Jonsson, H. P., Dahlbom, M. L., Daver, F., DiFranco, M. D., Opposits, G., Krizsan, A. K., Garai, I., Czernin, J., Varga, J., et al. (2016) · PLoS ONE · doi:10.1371/journal.pone.0164113 · Cited by 50
Interactive segmentation based on the live wire for 3D CT chest image analysis
Lu, K., & Higgins, W. E. (2007) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-007-0129-x · Cited by 42
Knollmann, F. D., Kumthekar, R. N., Fetzer, D. T., & Socinski, M. A. (2013) · Clinical Lung Cancer · doi:10.1016/j.cllc.2013.11.001 · Cited by 11
Harrell, F., Jr. (1996) · doi:10.1002/(sici)1097-0258(19960229)15:4<361::aid-sim168>3.0.co;2-4
Cited by
Solving inverse problems using data-driven models
Arridge, S., Maass, P., Öktem, O., & Schönlieb, C.-B. (2019) · Acta Numerica · doi:10.1017/s0962492919000059 · Cited by 686
Radiomics in breast cancer classification and prediction
Conti, A., Duggento, A., Indovina, I., Guerrisi, M., & Toschi, N. (2021) · Seminars in Cancer Biology · doi:10.1016/j.semcancer.2020.04.002 · Cited by 386
Radiomics: from qualitative to quantitative imaging
Rogers, W., Thulasi Seetha, S., Refaee, T. A. G., Lieverse, R. I. Y., Granzier, R. W. Y., Ibrahim, A., Keek, S. A., Sanduleanu, S., Primakov, S. P., Beuque, M. P. L., et al. (2020) · The British Journal of Radiology · doi:10.1259/bjr.20190948 · Cited by 372
Ki-67 as a Prognostic Biomarker in Invasive Breast Cancer
Davey, M. G., Hynes, S. O., Kerin, M. J., Miller, N., & Lowery, A. J. (2021) · Cancers · doi:10.3390/cancers13174455 · Cited by 298
Artificial Intelligence in Lung Cancer Pathology Image Analysis
Wang, S., Yang, D. M., Rong, R., Zhan, X., Fujimoto, J., Liu, H., Minna, J., Wistuba, I. I., Xie, Y., & Xiao, G. (2019) · Cancers · doi:10.3390/cancers11111673 · Cited by 291
Metadata
- Authors
- Rizzo, S., Botta, F., Raimondi, S., Origgi, D., Fanciullo, C., Morganti, A. G., & Bellomi, M.
- Venue
- European Radiology Experimental
- Published
- 2018-11-14
- Volume
- 2
- Issue
- 1
- Pages
- 36-36
- ISSN
- 2509-9280 (ISSN-L)
- OpenAlex
- W2900422713
- Cited by
- 1,054
- References
- 53
- FWCI
- 52.92
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.