The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Vibrational imaging of lipid droplets in live fibroblast cells with coherent anti-Stokes Raman scattering microscopy
Open accessAbstract
A new vibrational imaging method based on coherent anti-Stokes Raman scattering (CARS) has been used for high-speed, selective imaging of neutral lipid droplets (LDs) in unstained live fibroblast cells. LDs have a high density of C-H bonds and show a high contrast in laser-scanning CARS images taken at 2,845 cm-1, the frequency for aliphatic C-H vibrations. The contrast from LDs was confirmed by comparing CARS and Oil Red O (ORO)-stained fluorescence images. The fluorescent labeling processes were examined with CARS microscopy. It was found that ORO staining of fixed cells caused aggregation of LDs, whereas fixing with formaldehyde or staining with Nile Red did not affect LDs. CARS microscopy was also used to monitor the 3T3-L1 cell differentiation process, revealing that there was an obvious clearance of LDs at the early stage of differentiation. After that, the cells started to differentiate and reaccumulate LDs in the cytoplasm in a largely unsynchronized manner. Differentiated cells formed small colonies surrounded by undifferentiated cells that were devoid of LDs. These observations demonstrate that CARS microscopy can follow dynamic changes in live cells with chemical selectivity and noninvasiveness. CARS microscopy, in tandem with other techniques, provides exciting possibilities for studying LD dynamics under physiological conditions without perturbation of cell functions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-photon laser scanning fluorescence microscopy
Denk, W., Strickler, J. H., & Webb, W. W. (1990) · Science · doi:10.1126/science.2321027 · Cited by 9,488
Lodish, H. F. (1986) · Cited by 5,650
Nile red: a selective fluorescent stain for intracellular lipid droplets.
Greenspan, P., Mayer, E. P., & Fowler, S. D. (1985) · The Journal of cell biology · doi:10.1083/jcb.100.3.965 · Cited by 2,543
Understanding Adipocyte Differentiation
GREGOIRE, F. M., SMAS, C. M., & SUL, H. S. (1998) · Physiological Reviews · doi:10.1152/physrev.1998.78.3.783 · Cited by 2,376
Three-Dimensional Vibrational Imaging by Coherent Anti-Stokes Raman Scattering
Zumbusch, A., Holtom, G. R., & Xie, X. S. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.4142 · Cited by 1,626
Self-citationAn established pre-adipose cell line and its differentiation in culture
Green, H., & Meuth, M. (1974) · Cell · doi:10.1016/0092-8674(74)90116-0 · Cited by 1,111
The biogenesis and functions of lipid bodies in animals, plants and microorganisms
Murphy, D. (2001) · Progress in Lipid Research · doi:10.1016/s0163-7827(01)00013-3 · Cited by 962
Spontaneous heritable changes leading to increased adipose conversion in 3T3 cells
Green, H., & Kehinde, O. (1976) · Cell · doi:10.1016/0092-8674(76)90260-9 · Cited by 827
Rubin, C. S., Hirsch, A., Fung, C., & Rosen, O. M. (1978) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(17)34541-6 · Cited by 670
Brasaemle, D. L., Barber, T., Wolins, N. E., Serrero, G., Blanchette-Mackie, E. J., & Londos, C. (1997) · Journal of Lipid Research · doi:10.1016/s0022-2275(20)34939-7 · Cited by 644
Cited by
Chemical imaging of tissue in vivo with video-rate coherent anti-Stokes Raman scattering microscopy
Evans, C. L., Potma, E. O., Puoris'haag, M., Côté, D., Lin, C. P., & Xie, X. S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0508282102 · Cited by 957
Self-citationVibrational spectroscopic imaging of living systems: An emerging platform for biology and medicine
Cheng, J.-X., & Xie, X. S. (2015) · Science · doi:10.1126/science.aaa8870 · Cited by 874
Self-citationRaman spectroscopy: Recent advancements, techniques and applications
Das, R. S., & Agrawal, Y. K. (2011) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2011.08.003 · Cited by 773
Coherent Nonlinear Optical Imaging: Beyond Fluorescence Microscopy
Min, W., Freudiger, C. W., Lu, S., & Xie, X. S. (2011) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.012809.103512 · Cited by 604
Self-citationImaging lipid bodies in cells and tissues using third-harmonic generation microscopy
Débarre, D., Supatto, W., Pena, A.-M., Fabre, A., Tordjmann, T., Combettes, L., Schanne-Klein, M.-C., & Beaurepaire, E. (2006) · Nature Methods · doi:10.1038/nmeth813 · Cited by 578
Probing Liquid/Solid Interfaces at the Molecular Level
Zaera, F. (2012) · Chemical Reviews · doi:10.1021/cr2002068 · Cited by 458
The dynamic roles of intracellular lipid droplets: from archaea to mammals
Murphy, D. J. (2012) · Protoplasma · doi:10.1007/s00709-011-0329-7 · Cited by 397
Raman spectroscopy: techniques and applications in the life sciences
Shipp, D. W., Sinjab, F., & Notingher, I. (2017) · Advances in Optics and Photonics · doi:10.1364/aop.9.000315 · Cited by 396
Heterodyne coherent anti-Stokes Raman scattering (CARS) imaging
Potma, E. O., Evans, C. L., & Xie, X. S. (2006) · Optics Letters · doi:10.1364/ol.31.000241 · Cited by 319
Self-citationCoherent Anti-Stokes Raman Scattering Imaging of Axonal Myelin in Live Spinal Tissues
Wang, H., Fu, Y., Zickmund, P., Shi, R., & Cheng, J.-X. (2005) · Biophysical Journal · doi:10.1529/biophysj.105.061911 · Cited by 316
Self-citationHellerer, T., Axäng, C., Brackmann, C., Hillertz, P., Pilon, M., & Enejder, A. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0703594104 · Cited by 314
Cell biology of lipid droplets
Thiele, C., & Spandl, J. (2008) · Current Opinion in Cell Biology · doi:10.1016/j.ceb.2008.05.009 · Cited by 305
Single Cell Optical Imaging and Spectroscopy
Stender, A. S., Marchuk, K., Liu, C., Sander, S., Meyer, M. W., Smith, E. A., Neupane, B., Wang, G., Li, J., Cheng, J.-X., et al. (2013) · Chemical Reviews · doi:10.1021/cr300336e · Cited by 292
Self-citationRaman spectroscopy: an evolving technique for live cell studies
Smith, R., Wright, K. L., & Ashton, L. (2016) · The Analyst · doi:10.1039/c6an00152a · Cited by 285
Raman and CARS microspectroscopy of cells and tissues
Krafft, C., Dietzek, B., & Popp, J. (2009) · The Analyst · doi:10.1039/b822354h · Cited by 271
Kaufman, L. J., Brangwynne, C. P., Kasza, K. E., Filippidi, E., Gordon, V. D., Deisboeck, T. S., & Weitz, D. A. (2005) · Biophysical Journal · doi:10.1529/biophysj.105.061994 · Cited by 259
Fragala, M. S., Kenny, A. M., & Kuchel, G. A. (2015) · Sports Medicine · doi:10.1007/s40279-015-0305-z · Cited by 246
“Unlike other means of imaging, SHG allows high-resolution quantitative 3-dimensional imaging of unstained bundles of muscle fibers at the molecular level with minimal tissue sampling processing [157].”
MethodAnalysis of cholesterol trafficking with fluorescent probes
Maxfield, F. R., & Wüstner, D. (2012) · Methods in Cell Biology · doi:10.1016/b978-0-12-386487-1.00017-1 · Cited by 240
Shedding new light on lipid functions with CARS and SRS microscopy
Yu, Y., Ramachandran, P. V., & Wang, M. C. (2014) · Biochimica et Biophysica Acta (BBA) - Molecular and Cell Biology of Lipids · doi:10.1016/j.bbalip.2014.02.003 · Cited by 89
“In living cells and organisms, CRSmicroscopy is capable of revealing individual lipid droplets, including nascent droplets that may be particularly small [28,29].”
Metadata
- Authors
- Nan, X., Cheng, J.-X., & Xie, X. S.
- Venue
- Journal of Lipid Research
- Publisher
- Elsevier BV
- Published
- 2003-11
- Volume
- 44
- Issue
- 11
- Pages
- 2202-2208
- ISSN
- 0022-2275 (ISSN-L)
- OpenAlex
- W2168043901
- Cited by
- 311
- References
- 38
- FWCI
- 5.41
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.