Low basal and persistent pulsatile growth hormone secretion are revealed in normal and hyposomatotropic men studied with a new ultrasensitive chemiluminescence assay

Iranmanesh, A. · 1994 · Journal of Clinical Endocrinology & Metabolism
Cited by 139

The DOI matches its Crossref record.

Abstract

Serum GH concentrations assessed by conventional RIA and immunoradiometric assay (IRMA) are often undetectable in healthy fed and awake humans. Serum GH concentrations are also low in obese, hypothyroid, middle-aged, and older individuals. Accordingly, to better investigate the pathophysiology of GH release in relatively hyposomatotropic states, we compared a new and putatively ultrasensitive GH chemiluminescence (CL) assay with a conventional IRMA. We report that the sensitivity of the CL assay is approximately 0.005 microgram/L, with a median intraassay coefficient of variation over more than 3 logarithms of serum GH concentrations of 5.2% (range, 3.6-8.3%). In each of 2 normal young men and 4 categories of hyposomatotropic adults studied (2 obese, 2 hypothyroid, 2 middle-aged, and 3 older men), we observed detectable serum GH concentrations by CL assay of all samples collected at 10-min intervals for 24 h. In the same sera analyzed by IRMA, 22-98% of the daytime sample values fell below IRMA sensitivity (0.10 microgram/L). Within the IRMA-detectable range, the correlation between the 2 assays ranged between r = 0.893 to 0.989 (P < 0.001 in each subject). In the CL assay, serum GH concentrations declined to 0.018-0.030 microgram/L, but were never undetectable during the awake fed state. Deconvolution analysis of 11 GH series assayed by CL disclosed basal GH release and superimposed GH secretory bursts. In the low GH series, there was a mean frequency of 12 +/- 1.4 secretory events/24 h, a mass of GH secreted per burst of 1.0 +/- 0.35 microgram/L, a secretory burst half-duration of 21 +/- 3.3 min, and an apparent endogenous GH half-life of 14 +/- 0.85 min. Compared to the GH IRMA, the CL assay detected approximately 50% more GH secretory events, and GH secretory burst frequency was increased significantly at night vs. the daytime. Cosinor analysis revealed significant 24-h serum GH concentration rhythms in both assays, but an earlier mean acrophase (time of maximum) and lower mesor (mean values) were estimated in the CL assay than the IRMA. We conclude that within the IRMA-detectable range, the correlation between serum GH concentrations measured by CL and IRMA techniques is high. However, unlike the IRMA, the GH CL assay can detect serum GH concentrations consistently in the awake and fed state not only in young individuals but also in subjects with obesity, hypothyroidism, and middle and older age.(ABSTRACT TRUNCATED AT 400 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/jc.78.3.526

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Iranmanesh, A.
Venue
Journal of Clinical Endocrinology & Metabolism
Published
1994-03-01
Volume
78
Issue
3
Pages
526-535
ISSN
0021-972X (ISSN-L)
OpenAlex
W2069214336
Cited by
139
References
0
FWCI
5.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.