CoChat

The Stroke Outcomes and Neuroimaging of Intracranial Atherosclerosis (SONIA) Trial

Feldmann, E., Wilterdink, J. L., Kosinski, A., Lynn, M., Chimowitz, M. I., Sarafin, J., Smith, H. H., Nichols, F., Rogg, J., Cloft, H. J., Wechsler, L., Saver, J., Levine, S. R., Tegeler, C., Adams, R., Sloan, M., The Stroke Outcomes and Neuroimaging of Intracranial Atherosclerosis (SONIA) Trial Investigators · 2007 · Neurology
Cited by 338

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Transcranial Doppler ultrasound (TCD) and magnetic resonance angiography (MRA) can identify intracranial atherosclerosis but have not been rigorously validated against the gold standard, catheter angiography. The WASID trial (Warfarin Aspirin Symptomatic Intracranial Disease) required performance of angiography to verify the presence of intracranial stenosis, allowing for prospective evaluation of TCD and MRA. The aims of Stroke Outcomes and Neuroimaging of Intracranial Atherosclerosis (SONIA) trial were to define abnormalities on TCD/MRA to see how well they identify 50 to 99% intracranial stenosis of large proximal arteries on catheter angiography. STUDY DESIGN: SONIA standardized the performance and interpretation of TCD, MRA, and angiography. Study-wide cutpoints defining positive TCD/MRA were used. Hard copy TCD/MRA were centrally read, blind to the results of angiography. RESULTS: SONIA enrolled 407 patients at 46 sites in the United States. For prospectively tested noninvasive test cutpoints, positive predictive values (PPVs) and negative predictive values (NPVs) were TCD, PPV 36% (95% CI: 27 to 46); NPV, 86% (95% CI: 81 to 89); MRA, PPV 59% (95% CI: 54 to 65); NPV, 91% (95% CI: 89 to 93). For cutpoints modified to maximize PPV, they were TCD, PPV 50% (95% CI: 36 to 64), NPV 85% (95% CI: 81 to 88); MRA PPV 66% (95% CI: 58 to 73), NPV 87% (95% CI: 85 to 89). For each test, a characteristic performance curve showing how the predictive values vary with a changing test cutpoint was obtained. CONCLUSIONS: Both transcranial Doppler ultrasound and magnetic resonance angiography noninvasively identify 50 to 99% intracranial large vessel stenoses with substantial negative predictive value. The Stroke Outcomes and Neuroimaging of Intracranial Atherosclerosis trial methods allow transcranial Doppler ultrasound and magnetic resonance angiography to reliably exclude the presence of intracranial stenosis. Abnormal findings on transcranial Doppler ultrasound or magnetic resonance angiography require a confirmatory test such as angiography to reliably identify stenosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1212/01.wnl.0000261488.05906.c1

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 338

Metadata

Authors
Feldmann, E., Wilterdink, J. L., Kosinski, A., Lynn, M., Chimowitz, M. I., Sarafin, J., Smith, H. H., Nichols, F., Rogg, J., Cloft, H. J., Wechsler, L., Saver, J., Levine, S. R., Tegeler, C., Adams, R., Sloan, M., & The Stroke Outcomes and Neuroimaging of Intracranial Atherosclerosis (SONIA) Trial Investigators
Venue
Neurology
Published
2007-06-12
Volume
68
Issue
24
Pages
2099-2106
ISSN
  • 0028-3878 (ISSN-L)
  • 1526-632X
OpenAlex
W1994686921
Cited by
338
References
18
FWCI
14.58
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.