Can STOP-Bang and Pulse Oximetry Detect and Exclude Obstructive Sleep Apnea?
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Obstructive sleep apnea (OSA) is related to postoperative complications and is a common disorder. Most patients with sleep apnea are, however, undiagnosed, and there is a need for simple screening tools. We aimed to investigate whether STOP-Bang and oxygen desaturation index can identify subjects with OSA. METHODS: In this prospective, observational multicenter trial, 449 adult patients referred to a sleep clinic for evaluation of OSA were investigated with ambulatory polygraphy, including pulse oximetry and the STOP-Bang questionnaire in 4 Swedish centers. The STOP-Bang score is the sum of 8 positive answers to Snoring, Tiredness, Observed apnea, high blood Pressure, Body mass index >35 kg/m 2 , Age >50 years, Neck circumference >40 cm, and male Gender. RESULTS: The optimal STOP-Bang cutoff score was 6 for moderate and severe sleep apnea, defined as apnea-hypopnea index (AHI) ≥15, and the sensitivity and specificity for this score were 63% (95% CI, 0.55–0.70) and 69% (95% CI, 0.64–0.75), respectively. A STOP-Bang score of <2 had a probability of 95% (95% CI, 0.92–0.98) to exclude an AHI >15 and a STOP-Bang score of ≥6 had a specificity of 91% (95% CI, 0.87–0.94) for an AHI >15. The items contributing most to the STOP-Bang were the Bang items. There was a positive correlation between AHI versus STOP-Bang and between AHI versus oxygen desaturation index, Spearman ρ 0.50 (95% CI, 0.43–0.58) and 0.96 (95% CI, 0.94–0.97), respectively. CONCLUSIONS: STOP-Bang and pulse oximetry can be used to screen for sleep apnea. A STOP-Bang score of <2 almost excludes moderate and severe OSA, whereas nearly all the patients with a STOP-Bang score ≥6 have OSA. We suggest the addition of nightly pulse oximetry in patients with a STOP-Bang score of 2–5 when there is a need for screening for sleep apnea (ie, before surgery).
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In the general population, two Level 1b studies,499,616 three Level 2b studies,617–619 and one Level 3b620 found reasonably good correlations between oximetry ODI and PSG AHIs, though primarily when the 4% desaturation criteria was used to score respiratory events.”
From International Consensus Statement on Obstructive Sleep Apnea (2023) · cites this paper as [617]
In the citing paper
“However, a number of these studies were downgraded for using the oximetry off the PSG as the comparison to the PSG derived AHI,617,618 or for using highly selective populations.619”
From International Consensus Statement on Obstructive Sleep Apnea (2023) · cites this paper as [617]
Citations
Cites
Berry, R. B., Budhiraja, R., Gottlieb, D. J., Gozal, D., Iber, C., Kapur, V. K., Marcus, C. L., Mehra, R., Parthasarathy, S., Quan, S. F., et al. (2012) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.2172 · Cited by 5,302
STOP Questionnaire: A Tool to Screen Patients for Obstructive Sleep Apnea
Chung, F., Yegneswaran, B., Liao, P., Chung, S. A., Vairavanathan, S., Islam, S., Khajehdehi, A., & Shapiro, C. M. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31816d83e4 · Cited by 2,355
Chung, F., Abdullah, H. R., & Liao, P. (2016) · Chest · doi:10.1378/chest.15-0903 · Cited by 1,362
Effects of Age on Sleep Apnea in Men: I. Prevalence and Severity
BIXLER, E. O., VGONTZAS, A. N., TEN HAVE, T., TYSON, K., & KALES, A. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.157.1.9706079 · Cited by 1,244
High STOP-Bang score indicates a high probability of obstructive sleep apnoea
Chung, F., Subramanyam, R., Liao, P., Sasaki, E., Shapiro, C., & Sun, Y. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aes022 · Cited by 988
Nagappa, M., Liao, P., Wong, J., Auckley, D., Ramachandran, S. K., Memtsoudis, S., Mokhlesi, B., & Chung, F. (2015) · PLOS ONE · doi:10.1371/journal.pone.0143697 · Cited by 684
(2014) · Anesthesiology · doi:10.1097/aln.0000000000000053 · Cited by 676
Chung, F., Yegneswaran, B., Liao, P., Chung, S. A., Vairavanathan, S., Islam, S., Khajehdehi, A., & Shapiro, C. M. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31816d91b5 · Cited by 571
Finkel, K. J., Searleman, A. C., Tymkew, H., Tanaka, C. Y., Saager, L., Safer-Zadeh, E., Bottros, M., Selvidge, J. A., Jacobsohn, E., Pulley, D., et al. (2009) · Sleep Medicine · doi:10.1016/j.sleep.2008.08.007 · Cited by 460
Rose, J., Weiser, T. G., Hider, P., Wilson, L., Gruen, R. L., & Bickler, S. W. (2015) · The Lancet Global Health · doi:10.1016/s2214-109x(15)70087-2 · Cited by 420
Chung, F., Memtsoudis, S. G., Ramachandran, S. K., Nagappa, M., Opperer, M., Cozowicz, C., Patrawala, S., Lam, D., Kumar, A., Joshi, G. P., et al. (2016) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000001416 · Cited by 360
Perioperative Pulmonary Outcomes in Patients with Sleep Apnea After Noncardiac Surgery
Memtsoudis, S., Liu, S. S., Ma, Y., Chiu, Y. L., Walz, J. M., Gaber-Baylis, L. K., & Mazumdar, M. (2011) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3182009abf · Cited by 311
Proportion of surgical patients with undiagnosed obstructive sleep apnoea
Singh, M., Liao, P., Kobah, S., Wijeysundera, D. N., Shapiro, C., & Chung, F. (2013) · British Journal of Anaesthesia · doi:10.1093/bja/aes465 · Cited by 309
Farney, R. J., Walker, B. S., Farney, R. M., Snow, G. L., & Walker, J. M. (2011) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.1306 · Cited by 246
Chung, F., Liao, P., Elsaid, H., Islam, S., Shapiro, C. M., & Sun, Y. (2012) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318248f4f5 · Cited by 243
Sleep apnoea is a common occurrence in females
Franklin, K. A., Sahlin, C., Stenlund, H., & Lindberg, E. (2013) · European Respiratory Journal · doi:10.1183/09031936.00212711 · Cited by 183
Self-citationChiner, E., Signes-Costa, J., Arriero, J. M., Marco, J., Fuentes, I., & Sergado, A. (1999) · Thorax · doi:10.1136/thx.54.11.968 · Cited by 157
The European Sleep Apnoea Database (ESADA): report from 22 European sleep laboratories
Hedner, J., Grote, L., Bonsignore, M., McNicholas, W., Lavie, P., Parati, G., Sliwinski, P., Barbé, F., De Backer, W., Escourrou, P., et al. (2011) · European Respiratory Journal · doi:10.1183/09031936.00046710 · Cited by 150
NG, S. S. S., CHAN, T., TO, K., NGAI, J., TUNG, A., KO, F. W. S., & HUI, D. S. C. (2010) · Respirology · doi:10.1111/j.1440-1843.2009.01697.x · Cited by 136
Normal Oxyhemoglobin Saturation During Sleep
Gries, R. E., & Brooks, L. J. (1996) · CHEST Journal · doi:10.1378/chest.110.6.1489 · Cited by 115
A Rude Awakening — The Perioperative Sleep Apnea Epidemic
Memtsoudis, S. G., Besculides, M. C., & Mazumdar, M. (2013) · New England Journal of Medicine · doi:10.1056/nejmp1302941 · Cited by 105
A pilot validation study for the NOX T3TM portable monitor for the detection of OSA
Cairns, A., Wickwire, E. M., SCHAEFER, E. H., & Nyanjom, D. (2014) · Sleep And Breathing · doi:10.1007/s11325-013-0924-2 · Cited by 94
Validation of the Nox-T3 Portable Monitor for Diagnosis of Obstructive Sleep Apnea in Chinese Adults
Xu, L., Han, F., Keenan, B. T., Kneeland-Szanto, E., Yan, H., Dong, X., Chang, Y., Zhao, L., Zhang, X., Li, J., et al. (2017) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.6582 · Cited by 86
Vana, K. D., Silva, G. E., & Goldberg, R. (2013) · Research in Nursing & Health · doi:10.1002/nur.21512 · Cited by 85
The Utility of Three Screening Questionnaires for Obstructive Sleep Apnea in a Sleep Clinic Setting
Kim, B., Lee, E. M., Chung, Y.-S., Kim, W.-S., & Lee, S.-A. (2015) · Yonsei Medical Journal · doi:10.3349/ymj.2015.56.3.684 · Cited by 65
Predicting sleep disordered breathing in outpatients with suspected OSA
Cowan, D. C., Allardice, G., MacFarlane, D., Ramsay, D., Ambler, H., Banham, S., Livingston, E., & Carlin, C. (2014) · BMJ Open · doi:10.1136/bmjopen-2013-004519 · Cited by 63
Cited by
International Consensus Statement on Obstructive Sleep Apnea
Chang, J. L., Goldberg, A. N., Alt, J. A., Mohammed, A., Ashbrook, L., Auckley, D., Ayappa, I., Bakhtiar, H., Barrera, J. E., Bartley, B. L., et al. (2023) · International Forum of Allergy & Rhinology · doi:10.1002/alr.23079 · Cited by 350
Pivetta, B., Chen, L., Nagappa, M., Saripella, A., Waseem, R., Englesakis, M., & Chung, F. (2021) · JAMA Network Open · doi:10.1001/jamanetworkopen.2021.1009 · Cited by 210
“Sensitivity Log scale diagnostic odds ratio Point estimate (95% CI) I2, % Coefficient (SE) P value Point estimate (95% CI) I2, % Coefficient (SE) P value Apnea-hypopnea index ≥5 (45) Age (42) 91.0 (85.6 to 94.5) 98 0.064 (0.057) .26 1.72 (0.82 to 2.62) 98 0.115 (0.105) .28 Gender (45) 91.4 (86.4 to 94.6) 98 –0.010 (0.…”
InfluentialHwang, M., Nagappa, M., Guluzade, N. A., Saripella, A., Englesakis, M. F., & Chung, F. F. (2022) · BMC Anesthesiology · doi:10.1186/s12871-022-01912-1 · Cited by 99
Anesthesia for morbidly obese patients
Hardt, K., & Wappler, F. (2023) · Deutsches Ärzteblatt international · doi:10.3238/arztebl.m2023.0216 · Cited by 74
Dominguez, J. E., Cantrell, S. E., Habib, A. S., Izci‐Balserak, B., Lockhart, E., Louis, J. M., Miskovic, A., Nadler, J. W., Nagappa, M., O'Brien, L. M., et al. (2023) · Obstetrics and Gynecology · doi:10.1097/aog.0000000000005261 · Cited by 40
Metadata
- Authors
- Christensson, E., Franklin, K. A., Sahlin, C., Palm, A., Ulfberg, J., Eriksson, L. I., Lindberg, E., Hagel, E., & Jonsson Fagerlund, M.
- Affiliations
- Karolinska University Hospital (SE)
- Surgical and Perioperative Sciences, Surgery
- Umeå University (SE)
- Uppsala University (SE)
- Sleep Apnea Clinic, Capio Läkargruppen, Örebro, Sweden
- Karolinska Institutet (SE)
- Function Perioperative Medicine and Intensive Care, Karolinska University Hospital, Stockholm, Sweden
- Corresponding author
- Christensson, Eva
- Eriksson, Lars I.
- Hagel, Eva
- Venue
- Anesthesia & Analgesia
- Published
- 2018-09
- Volume
- 127
- Issue
- 3
- Pages
- 736-743
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2810457191
- Cited by
- 26
- References
- 26
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 2 · 2023: 3 · 2022: 6 · 2021: 6 · 2020: 2 · 2019: 1
- FWCI
- 1.54
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Anesthesia & Analgesia (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Chronic Obstructive Pulmonary Disease (COPD) Research
- Keywords
- obstructive sleep apnea, STOP-BANG questionnaire, pulse oximetry, oxygen desaturation index, sleep apnea screening, apnea-hypopnea index, diagnostic accuracy, preoperative screening
- MeSH terms
- Adult, Aged, Female, Humans, Hypertension, Male, Middle Aged, Oximetry, Preoperative Care, Prospective Studies, Surveys and Questionnaires, Snoring, Sweden, Body Mass Index, Polysomnography, Sleep Apnea, Obstructive
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›