The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Coagulation Monitoring: Current Techniques and Clinical Use of Viscoelastic Point-of-Care Coagulation Devices
Open accessAbstract
Perioperative monitoring of blood coagulation is critical to better understand causes of hemorrhage, to guide hemostatic therapies, and to predict the risk of bleeding during the consecutive anesthetic or surgical procedures. Point-of-care (POC) coagulation monitoring devices assessing the viscoelastic properties of whole blood, i.e., thrombelastography, rotation thrombelastometry, and Sonoclot analysis, may overcome several limitations of routine coagulation tests in the perioperative setting. The advantage of these techniques is that they have the potential to measure the clotting process, starting with fibrin formation and continue through to clot retraction and fibrinolysis at the bedside, with minimal delays. Furthermore, the coagulation status of patients is assessed in whole blood, allowing the plasmatic coagulation system to interact with platelets and red cells, and thereby providing useful additional information on platelet function. Viscoelastic POC coagulation devices are increasingly being used in clinical practice, especially in the management of patients undergoing cardiac and liver surgery. Furthermore, they provide useful information in a large variety of clinical scenarios, e.g., massive hemorrhage, assessment of hypo- and hypercoagulable states, guiding pro- and anticoagulant therapies, and in diagnosing of a surgical bleeding. A surgical etiology of bleeding has to be considered when viscoelastic test results are normal. In summary, viscoelastic POC coagulation devices may help identify the cause of bleeding and guide pro- and anticoagulant therapies. To ensure optimal accuracy and performance, standardized procedures for blood sampling and handling, strict quality controls and trained personnel are required.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ferraris, V. A., Ferraris, S. P., Saha, S. P., Hessel, E. A., Haan, C. K., Royston, B. D., Bridges, C. R., Higgins, R. S. D., Despotis, G., Brown, J. R., et al. (2007) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2007.02.099 · Cited by 964
Thromboelastography-Guided Transfusion Algorithm Reduces Transfusions in Complex Cardiac Surgery
Shore-Lesserson, L., Manspeizer, H. E., DePerio, M., Francis, S., Vela-Cantos, F., & Ergin, M. A. (1999) · Anesthesia & Analgesia · doi:10.1097/00000539-199902000-00016 · Cited by 845
Kang, Y. G., Martin, D. J., Marquez, J., Lewis, J. H., Bontempo, F. A., Shaw, B. W., Starzl, T. E., & Winter, P. M. (1985) · Anesthesia & Analgesia · doi:10.1213/00000539-198509000-00008 · Cited by 684
Di Nisio, M., Middeldorp, S., & Büller, H. R. (2005) · New England Journal of Medicine · doi:10.1056/nejmra044440 · Cited by 655
Thrombelastography/thromboelastometry
LUDDINGTON, R. J. (2005) · Clinical and Laboratory Haematology · doi:10.1111/j.1365-2257.2005.00681.x · Cited by 655
Blutgerinnungsstudien mit der Thrombelastographie, einem neuen Untersuchungsverfahren
Hartert, H. (1948) · Klinische Wochenschrift · doi:10.1007/bf01697545 · Cited by 615
Multi-centre investigation on reference ranges for ROTEM thromboelastometry
Lang, T., Bauters, A., Braun, S. L., Pötzsch, B., von Pape, K.-W., Kolde, H.-J., & Lakner, M. (2005) · Blood Coagulation & Fibrinolysis · doi:10.1097/01.mbc.0000169225.31173.19 · Cited by 503
Diagnosis of early coagulation abnormalities in trauma patients by rotation thrombelastography
RUGERI, L., LEVRAT, A., DAVID, J. S., DELECROIX, E., FLOCCARD, B., GROS, A., ALLAOUCHICHE, B., & NEGRIER, C. (2007) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2007.02319.x · Cited by 491
MALLETT, S. V., & COX, D. J. A. (1992) · British Journal of Anaesthesia · doi:10.1093/bja/69.3.307 · Cited by 431
Reverter, J. C., Béguin, S., Kessels, H., Kumar, R., Hemker, H. C., & Coller, B. S. (1996) · Journal of Clinical Investigation · doi:10.1172/jci118859 · Cited by 393
Cited by
Management of severe perioperative bleeding: Guidelines from the European Society of Anaesthesiology
Kozek-Langenecker, S. A., Afshari, A., Albaladejo, P., Santullano, C. A. A., De Robertis, E., Filipescu, D. C., Fries, D., Görlinger, K., Haas, T., Imberger, G., et al. (2013) · European Journal of Anaesthesiology · doi:10.1097/eja.0b013e32835f4d5b · Cited by 909
Point-of-care testing (POCT): Current techniques and future perspectives
Luppa, P. B., Müller, C., Schlichtiger, A., & Schlebusch, H. (2011) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2011.01.019 · Cited by 660
Schöchl, H., Nienaber, U., Hofer, G., Voelckel, W., Jambor, C., Scharbert, G., Kozek-Langenecker, S., & Solomon, C. (2010) · Critical Care · doi:10.1186/cc8948 · Cited by 637
ROURKE, C., CURRY, N., KHAN, S., TAYLOR, R., RAZA, I., DAVENPORT, R., STANWORTH, S., & BROHI, K. (2012) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2012.04752.x · Cited by 553
Functional definition and characterization of acute traumatic coagulopathy
Davenport, R., Manson, J., DeʼAth, H., Platton, S., Coates, A., Allard, S., Hart, D., Pearse, R., Pasi, K. J., MacCallum, P., et al. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e3182281af5 · Cited by 520
Platelet function tests: a comparative review
Paniccia, R., Priora, R., Alessandrello Liotta, A., & Abbate, R. (2015) · Vascular Health and Risk Management · doi:10.2147/vhrm.s44469 · Cited by 505
The incidence and magnitude of fibrinolytic activation in trauma patients
RAZA, I., DAVENPORT, R., ROURKE, C., PLATTON, S., MANSON, J., SPOORS, C., KHAN, S., De'ATH, H. D., ALLARD, S., HART, D. P., et al. (2013) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.12078 · Cited by 481
Bolliger, D., Seeberger, M. D., & Tanaka, K. A. (2012) · Transfusion Medicine Reviews · doi:10.1016/j.tmrv.2011.07.005 · Cited by 397
Holcomb, J. B., Minei, K. M., Scerbo, M. L., Radwan, Z. A., Wade, C. E., Kozar, R. A., Gill, B. S., Albarado, R., McNutt, M. K., Khan, S., et al. (2012) · Annals of Surgery · doi:10.1097/sla.0b013e3182658180 · Cited by 387
Anticoagulation and Coagulation Management for ECMO
Oliver, W. C. (2009) · Seminars in Cardiothoracic and Vascular Anesthesia · doi:10.1177/1089253209347384 · Cited by 357
Blood Coagulation: Hemostasis and Thrombin Regulation
Tanaka, K. A., Key, N. S., & Levy, J. H. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31819bcc9c · Cited by 342
Haas, T., Spielmann, N., Mauch, J., Madjdpour, C., Speer, O., Schmugge, M., & Weiss, M. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aer342 · Cited by 335
Whiting, P., Al, M., Westwood, M., Ramos, I. C., Ryder, S., Armstrong, N., Misso, K., Ross, J., Severens, J., & Kleijnen, J. (2015) · Health Technology Assessment · doi:10.3310/hta19580 · Cited by 310
Early Platelet Dysfunction: An Unrecognized Role in the Acute Coagulopathy of Trauma
Wohlauer, M. V., Moore, E. E., Thomas, S., Sauaia, A., Evans, E., Harr, J., Silliman, C. C., Ploplis, V., Castellino, F. J., & Walsh, M. (2012) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2012.01.050 · Cited by 291
Development and Applications of Portable Biosensors
Srinivasan, B., & Tung, S. (2015) · SLAS Technology · doi:10.1177/2211068215581349 · Cited by 262
Thrombelastography and tromboelastometry in assessing coagulopathy in trauma
Johansson, P. I., Stissing, T., Bochsen, L., & Ostrowski, S. R. (2009) · Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine · doi:10.1186/1757-7241-17-45 · Cited by 255
Haas, T., Fries, D., Tanaka, K. A., Asmis, L., Curry, N. S., & Schöchl, H. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aeu303 · Cited by 249
Jain, A., Graveline, A., Waterhouse, A., Vernet, A., Flaumenhaft, R., & Ingber, D. E. (2016) · Nature Communications · doi:10.1038/ncomms10176 · Cited by 182
Larsen, O. H., Fenger-Eriksen, C., Christiansen, K., Ingerslev, J., & Sørensen, B. (2011) · Anesthesiology · doi:10.1097/aln.0b013e318220755c · Cited by 117
Venema, L. F., Post, W. J., Hendriks, H. G., Huet, R. C., de Wolf, J. T., & de Vries, A. J. (2010) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181e368bc · Cited by 92
Hill, J. S., Devenie, G., & Powell, M. (2012) · Anaesthesia and Intensive Care · doi:10.1177/0310057x1204000612 · Cited by 50
Metadata
- Authors
- Ganter, M. T., & Hofer, C. K.
- Venue
- Anesthesia & Analgesia
- Published
- 2008-05
- Volume
- 106
- Issue
- 5
- Pages
- 1366-1375
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2025778465
- Cited by
- 677
- References
- 34
- FWCI
- 31.09
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.