The DOI matches its Crossref record; 80 of the 80 references it cites were found in a registry or an index.
Live-cell microscopy – tips and tools
Abstract
Imaging of living cells and tissue is now common in many fields of the life and physical sciences, and is instrumental in revealing a great deal about cellular dynamics and function. It is crucial when performing such experiments that cell viability is at the forefront of any measurement to ensure that the physiological and biological processes that are under investigation are not altered in any way. Many cells and tissues are not normally exposed to light during their life cycle, so it is important for microscopy applications to minimize light exposure, which can cause phototoxicity. To ensure minimal light exposure, it is crucial that microscope systems are optimized to collect as much light as possible. This can be achieved using superior-quality optical components and state-of-the-art detectors. This Commentary discusses how to set up a suitable environment on the microscope stage to maintain living cells. There is also a focus on general and imaging-platform-specific ways to optimize the efficiency of light throughput and detection. With an efficient optical microscope and a good detector, the light exposure can be minimized during live-cell imaging, thus minimizing phototoxicity and maintaining cell viability. Brief suggestions for useful microscope accessories as well as available fluorescence tools are also presented. Finally, a flow chart is provided to assist readers in choosing the appropriate imaging platform for their experimental systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Communication in the presence of noise
Shannon, C. E. (1949) · Proceedings of the IRE · doi:10.1109/jrproc.1949.232969 · Cited by 6,539
A guided tour into subcellular colocalization analysis in light microscopy
BOLTE, S., & CORDELIÈRES, F. P. (2006) · Journal of Microscopy · doi:10.1111/j.1365-2818.2006.01706.x · Cited by 5,324
Communication In The Presence Of Noise
Shannon, C. E. (1998) · Proceedings of the IEEE · doi:10.1109/jproc.1998.659497 · Cited by 4,804
Deep tissue two-photon microscopy
Helmchen, F., & Denk, W. (2005) · Nature Methods · doi:10.1038/nmeth818 · Cited by 4,153
Handbook Of Biological Confocal Microscopy
(2006) · Springer eBooks · doi:10.1007/978-0-387-45524-2 · Cited by 3,637
Certain Topics in Telegraph Transmission Theory
Nyquist, H. (1928) · Transactions of the American Institute of Electrical Engineers · doi:10.1109/t-aiee.1928.5055024 · Cited by 3,089
A guide to choosing fluorescent proteins
Shaner, N. C., Steinbach, P. A., & Tsien, R. Y. (2005) · Nature Methods · doi:10.1038/nmeth819 · Cited by 2,840
Nagai, T., Ibata, K., Park, E. S., Kubota, M., Mikoshiba, K., & Miyawaki, A. (2002) · Nature Biotechnology · doi:10.1038/nbt0102-87 · Cited by 2,753
Partitioning of Lipid-Modified Monomeric GFPs into Membrane Microdomains of Live Cells
Zacharias, D. A., Violin, J. D., Newton, A. C., & Tsien, R. Y. (2002) · Science · doi:10.1126/science.1068539 · Cited by 2,235
Handbook of Biological Confocal Microscopy
(1995) · Springer eBooks · doi:10.1007/978-1-4757-5348-6 · Cited by 1,848
Cited by
Phototoxicity in live fluorescence microscopy, and how to avoid it
Icha, J., Weber, M., Waters, J. C., & Norden, C. (2017) · BioEssays · doi:10.1002/bies.201700003 · Cited by 622
An optogenetic toolbox designed for primates
Diester, I., Kaufman, M. T., Mogri, M., Pashaie, R., Goo, W., Yizhar, O., Ramakrishnan, C., Deisseroth, K., & Shenoy, K. V. (2011) · Nature Neuroscience · doi:10.1038/nn.2749 · Cited by 443
Tutorial: guidance for quantitative confocal microscopy
Jonkman, J., Brown, C. M., Wright, G. D., Anderson, K. I., & North, A. J. (2020) · Nature Protocols · doi:10.1038/s41596-020-0313-9 · Cited by 401
Self-citationSingle Cell Optical Imaging and Spectroscopy
Stender, A. S., Marchuk, K., Liu, C., Sander, S., Meyer, M. W., Smith, E. A., Neupane, B., Wang, G., Li, J., Cheng, J.-X., et al. (2013) · Chemical Reviews · doi:10.1021/cr300336e · Cited by 292
Gradient light interference microscopy for 3D imaging of unlabeled specimens
Nguyen, T. H., Kandel, M. E., Rubessa, M., Wheeler, M. B., & Popescu, G. (2017) · Nature Communications · doi:10.1038/s41467-017-00190-7 · Cited by 259
Mechanosensing via cell-matrix adhesions in 3D microenvironments
Doyle, A. D., & Yamada, K. M. (2016) · Experimental Cell Research · doi:10.1016/j.yexcr.2015.10.033 · Cited by 253
Present Application and Perspectives of Organoid Imaging Technology
Fei, K., Zhang, J., Yuan, J., & Xiao, P. (2022) · Bioengineering · doi:10.3390/bioengineering9030121 · Cited by 65
Mwale, P. F., Hsieh, C.-T., Yen, T.-L., Jan, J.-S., Taliyan, R., Yang, C.-H., & Yang, W.-B. (2025) · Molecular Neurodegeneration · doi:10.1186/s13024-025-00801-8 · Cited by 47
Optical stimulation of neural tissue
Richardson, R. T., Ibbotson, M. R., Thompson, A. C., Wise, A. K., & Fallon, J. B. (2020) · Healthcare Technology Letters · doi:10.1049/htl.2019.0114 · Cited by 40
“such as the cochlea is of equal concern for the optogenetic stimulation as it is for INS, as is phototoxicity from the use of high intensity visible light that is well known in the field of live cell microscopy [101, 102].”
BackgroundShi, M., Calaruso, P., & Mody, C. H. (2012) · Cellular Microbiology · doi:10.1111/cmi.12027 · Cited by 32
Metadata
- Authors
- Frigault, M. M., Lacoste, J., Swift, J. L., & Brown, C. M.
- Venue
- Journal of Cell Science
- Publisher
- The Company of Biologists
- Published
- 2009-03-15
- Volume
- 122
- Issue
- 6
- Pages
- 753-767
- ISSN
- 0021-9533 (ISSN-L)
- 1477-9137
- OpenAlex
- W1978372216
- Cited by
- 304
- References
- 80
- FWCI
- 10.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.