Effect of Monitor Placement and of Activity Setting on the MTI Accelerometer Output
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
PURPOSE: To examine the effect of monitor placement (hip vs back) and of activity setting (treadmill vs track) on the output from the Manufacturing Technology Inc. (MTI), activity monitor (model WAM 7164). METHODS: In a laboratory study, 28 subjects (14 men, 14 women) walked at a normal pace, walked at a fast pace, and jogged at a comfortable pace on an indoor track. These activities were repeated on a treadmill using the individual speeds from the track locomotion. Oxygen uptake was measured simultaneously using a portable metabolic system. One activity monitor was worn on the hip and one on the lower back. In a field study, 34 subjects (18 men, 16 women) each wore two monitors (hip and low back placement) for seven consecutive days. In the laboratory study, ANOVA showed significant effects of placement ( P = 0.009) and setting ( P < 0.001), indicating that activity counts differ between different body sites and different settings (track vs treadmill). Gross energy expenditure predictive equations were developed and thereafter evaluated in the field study. Time spent at moderate and vigorous intensity of physical activity was 38% and 85% ( P < 0.001) higher when calculated from the treadmill-based equations as compared to the track-based equations. Free-living physical activity estimates were not affected by the placement. CONCLUSION: The relationship between activity counts and energy expenditure during laboratory locomotion is placement and setting-specific. When habitual physical activity is assessed in free-living subjects, the treadmill derived relationship between energy expenditure and activity counts may overestimate time spent at moderate intensity of physical activity, whereas the placement of the monitor does not influence on the interpretation of the data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
New methods for calculating metabolic rate with special reference to protein metabolism
Weir, J. B. D. V. (1949) · The Journal of Physiology · doi:10.1113/jphysiol.1949.sp004363 · Cited by 5,603
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825 · cited 7×
“(8]; Equation 2; locomotor activities [Hendelman et al.”
BackgroundMethodInfluentialValidity of the computer science and applications (CSA) activity monitor in children
TROST, S. G., WARD, D. S., MOOREHEAD, S. M., WATSON, P. D., RINER, W., & BURKE, J. R. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199804000-00023 · Cited by 769
Cited by
Physical Activity in the United States Measured by Accelerometer
TROIANO, R. P., BERRIGAN, D., DODD, K. W., MÂSSE, L. C., TILERT, T., & MCDOWELL, M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815a51b3 · Cited by 7,638
“adolescents (ages 18 or older), intensity thresholds were calculated as a weighted average of criteria determined from four studies that based criteria on treadmill or track walking (4,10,14,35).”
MethodConducting accelerometer-based activity assessments in field-based research
TROST, S. G., MCIVER, K. L., & PATE, R. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185657.86065.98 · Cited by 2,033
Hagströmer, M., Oja, P., & Sjöström, M. (2006) · Public Health Nutrition · doi:10.1079/phn2005898 · Cited by 1,958
Self-citationPhysical Activity in U.S. Adults
Tucker, J. M., Welk, G. J., & Beyler, N. K. (2011) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2010.12.016 · Cited by 977
Calibration of Accelerometer Output for Adults
MATTHEW, C. E. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185659.11982.3d · Cited by 659
Direct measurement of human movement by accelerometry
Godfrey, A., Conway, R., Meagher, D., & ÓLaighin, G. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.09.005 · Cited by 591
Ekelund, U., Sardinha, L. B., Anderssen, S. A., Harro, M., Franks, P. W., Brage, S., Cooper, A. R., Andersen, L. B., Riddoch, C., & Froberg, K. (2004) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/80.3.584 · Cited by 428
Self-citationPhysical Activity and Inactivity in an Adult Population Assessed by Accelerometry
HAGSTRÖMER, M., OJA, P., & SJÖSTRÖM, M. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3180a76de5 · Cited by 397
Self-citationDowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
“Study methodologies included the wearing of devices over the left and right hip [337, 370, 385, 387, 406, 413, 415, 417], over the hip and lower back [409], the wearing of devices side by side at the same location on the hip [301, 344, 411, 414, 416–418], devices worn at 3 intercostal space and just below the apex of…”
MethodSelf-citationEstimating energy expenditure using accelerometers
Crouter, S. E., Churilla, J. R., & Bassett, D. R. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-006-0307-5 · Cited by 366
Physical Activity in US Youth: Effect of Race/Ethnicity, Age, Gender, and Weight Status
BELCHER, B. R., BERRIGAN, D., DODD, K. W., EMKEN, B. A., CHOU, C.-P., & SPRUIJT-METZ, D. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181e1fba9 · Cited by 355
on behalf of the HELENA Study Group, Hagströmer, M., Bergman, P., De Bourdeaudhuij, I., Ortega, F. B., Ruiz, J. R., Manios, Y., Rey-López, J. P., Phillipp, K., von Berlepsch, J., et al. (2008) · International Journal of Obesity · doi:10.1038/ijo.2008.182 · Cited by 349
Self-citationA novel method for using accelerometer data to predict energy expenditure
Crouter, S. E., Clowers, K. G., & Bassett, D. R. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00818.2005 · Cited by 345
Accelerometer-based measures in physical activity surveillance: current practices and issues
Pedišić, Ž., & Bauman, A. (2015) · British Journal of Sports Medicine · doi:10.1136/bjsports-2013-093407 · Cited by 330
Vähä-Ypyä, H., Vasankari, T., Husu, P., Mänttäri, A., Vuorimaa, T., Suni, J., & Sievänen, H. (2015) · PLOS ONE · doi:10.1371/journal.pone.0134813 · Cited by 277
Hagstromer, M., Troiano, R. P., Sjostrom, M., & Berrigan, D. (2010) · American Journal of Epidemiology · doi:10.1093/aje/kwq069 · Cited by 271
International Physical Activity Questionnaire: Reliability and validity in a Spanish population
Roman‐Viñas, B., Serra‐Majem, L., Hagströmer, M., Ribas‐Barba, L., Sjöström, M., & Segura‐Cardona, R. (2010) · European Journal of Sport Science · doi:10.1080/17461390903426667 · Cited by 258
Self-citationComparison of a subjective and an objective measure of physical activity in a population sample
Hagstromer, M., Ainsworth, B. E., Oja, P., & Sjostrom, M. (2010) · Journal of Physical Activity and Health · doi:10.1123/jpah.7.4.541 · Cited by 255
“The threshold criteria used in this study for the time required for wearing the Actigraph is also consistent with the procedures used in the international IPAQ validity study(3) and in other studies using.(11,16) The Actigraph data were uploaded onto a computer and analyzed by software based on Microsoft Access.”
MethodLoyen, A., Clarke-Cornwell, A. M., Anderssen, S. A., Hagströmer, M., Sardinha, L. B., Sundquist, K., Ekelund, U., Steene-Johannessen, J., Baptista, F., Hansen, B. H., et al. (2017) · Sports Medicine · doi:10.1007/s40279-016-0658-y · Cited by 182
“Even though studies have shown that there are no significant differences between accelerometer placement on the hip or lower back [33], there is some discussion about the comparability of the results of the two ActiGraph models [34–36].”
ResultSelf-citationPhysical activity levels in patients with early knee osteoarthritis measured by accelerometry
Farr, J. N., Going, S. B., Lohman, T. G., Rankin, L., Kasle, S., Cornett, M., & Cussler, E. (2008) · Arthritis Care & Research · doi:10.1002/art.24007 · Cited by 181
“A number of studies have demonstrated its durability, reliability, and validity in adults against criterion methods such as heart rate monitoring and indirect calorimetry (25-29).”
InfluentialMeasurement Methods for Physical Activity and Energy Expenditure: a Review
Ndahimana, D., & Kim, E.-K. (2017) · Clinical Nutrition Research · doi:10.7762/cnr.2017.6.2.68 · Cited by 179
“Some of equations permit to calculate energy expenditure as metabolic equivalents (METs) [58-60] or kcal/min [60,61].”
BackgroundComparing the performance of three generations of ActiGraph accelerometers
Rothney, M. P., Apker, G. A., Song, Y., & Chen, K. Y. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.90641.2008 · Cited by 177
Validity of Physical Activity Intensity Predictions by ActiGraph, Actical, and RT3 Accelerometers
Rothney, M. P., Schaefer, E. V., Neumann, M. M., Choi, L., & Chen, K. Y. (2008) · Obesity · doi:10.1038/oby.2008.279 · Cited by 175
Comparison of PAEE from Combined and Separate Heart Rate and Movement Models in Children
Corder, K., Brage, S., Wareham, N. J., & Ekelund, U. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000176466.78408.cc · Cited by 170
Self-citationSchmid, D., Ricci, C., & Leitzmann, M. F. (2015) · PLOS ONE · doi:10.1371/journal.pone.0119591 · Cited by 159
“Moderate to vigorous physical activity was defined as a minimum of 2,020 counts per minute, which represents the weighted average cutpoint for moderate to vigorous physical activity from published calibration studies [25, 26, 28, 29] as described by Metzger et al.”
Physical Activity and Modernization among Bolivian Amerindians
Gurven, M., Jaeggi, A. V., Kaplan, H., & Cummings, D. (2013) · PLoS ONE · doi:10.1371/journal.pone.0055679 · Cited by 129
“equation [31] otherwise: 1.”
Brage, S., Brage, N., Ekelund, U., Luan, J., Franks, P. W., Froberg, K., & Wareham, N. J. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-005-0112-6 · Cited by 127
“2000) and lower back during treadmill activity but not during free-living (Yngve et al. 2003).”
BackgroundSelf-citationModerate to vigorous physical activity and weight outcomes: does every minute count?
Fan, J. X., Brown, B. B., Hanson, H., Kowaleski-Jones, L., Smith, K. R., & Zick, C. D. (2013) · American Journal of Health Promotion · doi:10.4278/ajhp.120606-qual-286 · Cited by 84
Predicting walking METs and energy expenditure from speed or accelerometry
BROOKS, A. G., GUNN, S. M., WITHERS, R. T., GORE, C. J., & PLUMMER, J. L. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000170074.19649.0e · Cited by 73
Ten Hoor, G. A., Rutten, G. M., Van Breukelen, G. J. P., Kok, G., Ruiter, R. A. C., Meijer, K., Kremers, S. P. J., Feron, F. J. M., Crutzen, R., Schols, A. M. J. W., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-018-0727-8 · Cited by 33
Metadata
- Authors
- YNGVE, A., NILSSON, A., SJ??STR??M, M., & EKELUND, U.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2003-02
- Volume
- 35
- Issue
- 2
- Pages
- 320-326
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2036623705
- Cited by
- 192
- References
- 4
- FWCI
- 3.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.