CoChat

Accelerometer-based Physical Activity: Total Volume per Day and Standardized Measures

BASSETT, DAVID R., TROIANO, RICHARD P., MCCLAIN, JAMES J., WOLFF, DANA L. · 2015 · Medicine & Science in Sports & Exercise
Cited by 177

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Abstract

The use of accelerometers in physical activity (PA) research has increased exponentially over the past 20 yr. The first commercially available accelerometer for assessing PA, the Caltrac, was worn on the waist and estimated PA energy expenditure in kilocalories. Around 1995, the emphasis shifted to measuring minutes of moderate-to-vigorous PA (MVPA), especially for bouts of 10 min or longer. Recent studies, however, show that light-intensity PA and intermittent (nonbout) MVPA also have important health benefits. The total volume of PA performed is an important variable because it takes the frequency, intensity, and duration of activity bouts and condenses them down into a single metric. The total volume of PA is appropriate for many research applications and can enhance comparisons between studies. In the future, machine learning algorithms will provide improved accuracy for activity type recognition and estimation of PA energy expenditure. However, in the current landscape of objectively measured PA, total activity counts per day (TAC/d) is a proxy for the total volume of PA. TAC/d percentiles for age- and gender-specific groups have been developed from the National Health and Nutrition Examination Survey ActiGraph data (2003-2006), providing a novel way to assess PA. The use of TAC/d or standardized units of acceleration could harmonize PA across studies. TAC/d should be viewed as an additional metric, not intended to replace other metrics (e.g., sedentary time, light-intensity PA, moderate PA, and vigorous PA) that may also be related to health. As future refinements to wearable monitors occur, researchers should continue to consider metrics that reflect the total volume of PA in addition to existing PA metrics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1249/mss.0000000000000468

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Cited by

See all 177

Metadata

Authors
BASSETT, D. R., TROIANO, R. P., MCCLAIN, J. J., & WOLFF, D. L.
Venue
Medicine & Science in Sports & Exercise
Published
2015-04
Volume
47
Issue
4
Pages
833-838
ISSN
0195-9131 (ISSN-L)
OpenAlex
W1984246512
Cited by
177
References
15
FWCI
11.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accelerometer-based Physical Activity: Total Volume per Day and Standardized Measures. https://app.cochat.ai/papers/10.1249/mss.0000000000000468
The paper
BASSETT, D. R., TROIANO, R. P., MCCLAIN, J. J., & WOLFF, D. L. (2015). Accelerometer-based Physical Activity: Total Volume per Day and Standardized Measures. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/mss.0000000000000468

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.