The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Mechanisms of Smooth Muscle Cell Proliferation and Endothelial Regeneration After Vascular Injury and Stenting - Approach to Therapy -
Open accessAbstract
Bare metal stents (BMS) successfully prevented abrupt artery closure and reduced the restenosis rate compared with balloon angioplasty. This review summarizes laboratory and recent clinical investigations concerning neointimal formation and endothelial regeneration after vascular injury. BMS efficacy was severely hampered by proliferating vascular smooth muscle cells (VSMCs), and the resultant neointimal hyperplasia, which is the only mechanism responsible for restenosis after metal stent placement. The advent of drug-eluting stents (DES) in 2002 have since then revolutionized interventional cardiology. By using the stent struts as a platform coated with polymers to elute drugs targeting VSMC proliferation, a substantial attenuation of in-stent restenosis is feasible. As with any medical innovation this technology still has restrictive factors, and novel approaches are promoted to improve the safety and efficacy of DES. Indeed, the antiproliferative properties of DES impair and/or delay endothelialization, hence leading to late stent thrombosis. Improvements in percutaneous coronary intervention procedures include the use of the so-called "second-generation DES", together with new coating technologies, bioabsorbable stents, and non-drug-based stent coatings. Particular emphasis will be placed on the concept that endothelial regeneration might be pursued as well as reduction of VSMC proliferation to allow stable successful revascularization after DES deployment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Serruys, P. W., de Jaegere, P., Kiemeneij, F., Macaya, C., Rutsch, W., Heyndrickx, G., Emanuelsson, H., Marco, J., Legrand, V., Materne, P., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310801 · Cited by 4,556
Moses, J. W., Leon, M. B., Popma, J. J., Fitzgerald, P. J., Holmes, D. R., O'Shaughnessy, C., Caputo, R. P., Kereiakes, D. J., Williams, D. O., Teirstein, P. S., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035071 · Cited by 4,224
Iakovou, I. (2005) · JAMA · doi:10.1001/jama.293.17.2126 · Cited by 3,132
A Polymer-Based, Paclitaxel-Eluting Stent in Patients with Coronary Artery Disease
Stone, G. W., Ellis, S. G., Cox, D. A., Hermiller, J., O'Shaughnessy, C., Mann, J. T., Turco, M., Caputo, R., Bergin, P., Greenberg, J., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032441 · Cited by 2,749
Pathology of Drug-Eluting Stents in Humans
Joner, M., Finn, A. V., Farb, A., Mont, E. K., Kolodgie, F. D., Ladich, E., Kutys, R., Skorija, K., Gold, H. K., & Virmani, R. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.03.042 · Cited by 2,744
Long-Term Outcomes with Drug-Eluting Stents versus Bare-Metal Stents in Sweden
Lagerqvist, B., James, S. K., Stenestrand, U., Lindbäck, J., Nilsson, T., & Wallentin, L. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa067722 · Cited by 1,197
Incomplete Stent Apposition and Very Late Stent Thrombosis After Drug-Eluting Stent Implantation
Cook, S., Wenaweser, P., Togni, M., Billinger, M., Morger, C., Seiler, C., Vogel, R., Hess, O., Meier, B., & Windecker, S. (2007) · Circulation · doi:10.1161/circulationaha.106.658237 · Cited by 839
Serruys, P. W., Ormiston, J. A., Onuma, Y., Regar, E., Gonzalo, N., Garcia-Garcia, H. M., Nieman, K., Bruining, N., Dorange, C., Miquel-Hébert, K., et al. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60325-1 · Cited by 820
Kedhi, E., Joesoef, K. S., McFadden, E., Wassing, J., van Mieghem, C., Goedhart, D., & Smits, P. C. (2010) · The Lancet · doi:10.1016/s0140-6736(09)62127-9 · Cited by 687
Windecker, S., Serruys, P. W., Wandel, S., Buszman, P., Trznadel, S., Linke, A., Lenk, K., Ischinger, T., Klauss, V., Eberli, F., et al. (2008) · The Lancet · doi:10.1016/s0140-6736(08)61244-1 · Cited by 653
Hypersensitivity Cases Associated With Drug-Eluting Coronary Stents
Nebeker, J. R., Virmani, R., Bennett, C. L., Hoffman, J. M., Samore, M. H., Alvarez, J., Davidson, C. J., McKoy, J. M., Raisch, D. W., Whisenant, B. K., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.07.071 · Cited by 610
Morphological Predictors of Restenosis After Coronary Stenting in Humans
Farb, A., Weber, D. K., Kolodgie, F. D., Burke, A. P., & Virmani, R. (2002) · Circulation · doi:10.1161/01.cir.0000019071.72887.bd · Cited by 593
Kirtane, A. J., Gupta, A., Iyengar, S., Moses, J. W., Leon, M. B., Applegate, R., Brodie, B., Hannan, E., Harjai, K., Jensen, L. O., et al. (2009) · Circulation · doi:10.1161/circulationaha.108.826479 · Cited by 577
Lemos, P. A., Serruys, P. W., van Domburg, R. T., Saia, F., Arampatzis, C. A., Hoye, A., Degertekin, M., Tanabe, K., Daemen, J., Liu, T. K. K., et al. (2004) · Circulation · doi:10.1161/01.cir.0000109138.84579.fa · Cited by 543
Jasti, V., Ivan, E., Yalamanchili, V., Wongpraparut, N., & Leesar, M. A. (2004) · Circulation · doi:10.1161/01.cir.0000146338.62813.e7 · Cited by 410
Lafont, A., Guzman, L. A., Whitlow, P. L., Goormastic, M., Cornhill, J. F., & Chisolm, G. M. (1995) · Circulation Research · doi:10.1161/01.res.76.6.996 · Cited by 310
Inhibition of cellular ras prevents smooth muscle cell proliferation after vascular injury in vivo
Indolfi, C., Avvedimento, E. V., Rapacciuolo, A., Lorenzo, E. D., Esposito, G., Stabile, E., Feliciello, A., Mele, E., Giuliano, P., Condorelli, G., et al. (1995) · Nature Medicine · doi:10.1038/nm0695-541 · Cited by 228
Self-citationBalakrishnan, B., Tzafriri, A. R., Seifert, P., Groothuis, A., Rogers, C., & Edelman, E. R. (2005) · Circulation · doi:10.1161/circulationaha.104.512475 · Cited by 210
Molecular Basis of Restenosis and Novel Issues of Drug-Eluting Stents
Inoue, T., & Node, K. (2009) · Circulation Journal · doi:10.1253/circj.cj-09-0059 · Cited by 186
Long-Term Clinical Outcomes Following Drug-eluting and Bare Metal Stenting in Massachusetts
Mauri, L., Silbaugh, T. S., Wolf, R., Zelevinsky, K., Lovett, A. F., Zhou, Z., Resnic, F. S., & Normand, S. (2008) · Circulation · doi:10.1161/circulationaha.108.781377 · Cited by 152
Indolfi, C., Esposito, G., Lorenzo, E. D., Rapacciuolo, A., Feliciello, A., Porcellini, A., Avvedimento, V. E., Condorelli, M., & Massimo Chiariello, A. (1995) · Circulation · doi:10.1161/01.cir.92.5.1230 · Cited by 136
Self-citationImpaired Endothelial Vasomotor Function After Sirolimus-Eluting Stent Implantation
Fuke, S., Maekawa, K., Kawamoto, K., Saito, H., Sato, T., Hioka, T., & Ohe, T. (2007) · Circulation Journal · doi:10.1253/circj.71.220 · Cited by 114
Indolfi, C., Torella, D., Cavuto, L., Davalli, A. M., Coppola, C., Esposito, G., Carriero, M. V., Rapacciuolo, A., Lorenzo, E. D., Stabile, E., et al. (2001) · Circulation · doi:10.1161/01.cir.103.24.2980 · Cited by 106
Self-citationIndolfi, C., Torella, D., Coppola, C., Curcio, A., Rodríguez, F., Bilancio, A., Leccia, A., Arcucci, O., Falco, M. L., Leosco, D., et al. (2002) · Circulation Research · doi:10.1161/01.res.0000046233.94299.d6 · Cited by 95
Self-citationIndolfi, C., Pavía, M., & Angelillo, I. F. (2005) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2005.01.040 · Cited by 89
Self-citationSilent Myocardial Ischemia in Patients With Diabetes Mellitus
Massimo Chiariello, A., & Indolfi, C. (1996) · Circulation · doi:10.1161/01.cir.93.12.2089 · Cited by 82
Self-citationTorella, D., Curcio, A., Gasparri, C., Galuppo, V., Serio, D. D., Surace, F. C., Cavaliere, A. L., Leone, A., Coppola, C., Ellison, G. M., et al. (2007) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00887.2006 · Cited by 74
Self-citationSirolimus for the Prevention of In-Stent Restenosis in a Coronary Artery
Marks, A. R. (2003) · New England Journal of Medicine · doi:10.1056/nejmp038141 · Cited by 72
Indolfi, C., Lorenzo, E. D., Rapacciuolo, A., Stingone, A. M., Stabile, E., Leccia, A., Torella, D., Caputo, R., Ciardiello, F., Tortora, G., et al. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00679-3 · Cited by 71
Self-citationAging exacerbates negative remodeling and impairs endothelial regeneration after balloon injury
Torella, D., Leosco, D., Indolfi, C., Curcio, A., Coppola, C., Ellison, G. M., Russo, V. G., Torella, M., Volti, G. L., Rengo, F., et al. (2004) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01119.2003 · Cited by 64
Self-citationIndolfi, C., Stabile, E., Coppola, C., Gallo, A., Perrino, C., Allevato, G., Cavuto, L., Torella, D., Lorenzo, E. D., Troncone, G., et al. (2001) · Circulation Research · doi:10.1161/01.res.88.3.319 · Cited by 49
Self-citation
Cited by
The vascular smooth muscle cell in arterial pathology: a cell that can take on multiple roles
Lacolley, P., Regnault, V., Nicoletti, A., Li, Z., & Michel, J.-B. (2012) · Cardiovascular Research · doi:10.1093/cvr/cvs135 · Cited by 701
Wu, J., Jin, L., Tan, J.-Y., Chen, X.-F., Wang, Q.-Q., Yuan, G.-Y., & Chen, T.-X. (2021) · Annals of Translational Medicine · doi:10.21037/atm-21-1375 · Cited by 17
Metadata
- Authors
- Curcio, A., Torella, D., & Indolfi, C.
- Venue
- Circulation Journal
- Publisher
- Japanese Circulation Society
- Published
- 2011
- Volume
- 75
- Issue
- 6
- Pages
- 1287-1296
- ISSN
- 1346-9843 (ISSN-L)
- 1347-4820
- OpenAlex
- W2326531080
- Cited by
- 262
- References
- 31
- FWCI
- 20.79
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.