Effective radiation doses of CT examinations in Japan: a nationwide questionnaire-based study
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The aims of this study were to estimate the effective radiation doses from CT examinations of both adults and children in Japan and to study the impact of various scan parameters on the effective doses. METHODS: A questionnaire, which contained detailed questions on the CT scan parameters employed, was distributed to 3000 facilities throughout Japan. For each scanner protocol, the effective doses for head (non-helical and helical), chest and upper abdomen acquisitions were estimated using ImPACT CT Patient Dosimetry Calculator software v. 1.0.4 (St George's Hospital, London, UK). RESULTS: The mean effective doses for chest and abdominal examinations using 80-110 kV were significantly lower than those using 120 kV. However, there was no statistically significant difference in the mean effective doses for head scans between facilities employing 80-110 kV and 120 kV. In chest and abdominal examinations, the mean effective doses using CT scanners from Western manufacturers [Siemens (Forchheim, Germany), Philips (Eindhoven, Netherlands) and GE Medical Systems (Milwaukee, WI)] were significantly lower than those of examinations using Japanese scanners [Hitachi (Kashiwa, Japan) and Toshiba (Otawara, Tochigi, Japan)], except for in paediatric chest examinations. CONCLUSION: The mean effective doses for adult head, chest and abdominal CT examinations were 2.9, 7.7 and 10.0 mSv, respectively, whereas the corresponding mean effective doses for paediatric examinations were 2.6, 7.1 and 7.7 mSv, respectively. ADVANCES IN KNOWLEDGE: Facilities using CT scanners by Western manufacturers commonly adopt low-tube-voltage techniques, and low-tube-voltage CT may be useful for reducing the radiation doses to the patients, particularly for the body region.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“It is also documented that CT is a known significant contributor to the individual and population radiation exposure dose [1].”
From Adult Computed Tomography examinations in Uganda: Towards determining the National Diagnostic Reference Levels (2022) · cites this paper as [1]
Citations
Cites
Preface, Executive Summary and Glossary
(2007) · Annals of the ICRP · doi:10.1016/j.icrp.2007.10.003 · Cited by 2,106
Effective Doses in Radiology and Diagnostic Nuclear Medicine: A Catalog
Mettler, F. A., Huda, W., Yoshizumi, T. T., & Mahesh, M. (2008) · Radiology · doi:10.1148/radiol.2481071451 · Cited by 2,008
Risk of cancer from diagnostic X-rays: estimates for the UK and 14 other countries
de González, A. B., & Darby, S. (2004) · The Lancet · doi:10.1016/s0140-6736(04)15433-0 · Cited by 1,718
Benefits and costs, an eternal balance
Dixon, A. K. (2007) · Annals of the ICRP · doi:10.1016/j.icrp.2007.09.001 · Cited by 1,355
1990 Recommendations of the International Commission on Radiological Protection.
(1991) · PubMed · Cited by 908
AAPM/RSNA Physics Tutorial for Residents: Topics in CT: Radiation Dose in CT
McNitt-Gray, M. F. (2002) · RadioGraphics · doi:10.1148/rg.226025128 · Cited by 612
National survey of doses from CT in the UK: 2003
Shrimpton, P. C., Hillier, M. C., Lewis, M. A., & Dunn, M. (2006) · The British Journal of Radiology · doi:10.1259/bjr/93277434 · Cited by 568
Effective dose: how should it be applied to medical exposures?
Martin, C. J. (2007) · The British Journal of Radiology · doi:10.1259/bjr/25922439 · Cited by 377
(1991) · Annals of the ICRP · doi:10.1016/0146-6453(91)90009-6 · Cited by 295
Influence of patient age on normalized effective doses calculated for CT examinations
Khursheed, A., Hillier, M. C., Shrimpton, P. C., & Wall, B. F. (2002) · The British Journal of Radiology · doi:10.1259/bjr.75.898.750819 · Cited by 191
Research works printed but not linked: 5
- The International Commission on Radiological Protection, 2007, Ann ICRP, 37, 1
- The International Commission on Radiological Protection, 2007, Ann ICRP, 37, 1
- United Nations Scientific Committee on the Effects of Atomic Radiation, 2010, UNSCEAR 2008 Report to the General Assembly with scientific Annexes
- Matsunaga Y, 2015, Radiat Prot Dosimetry
- Kawaguchi A, 2014, Radiat Prot Dosimetry
Cited by
Chida, K. (2022) · Radiological Physics and Technology · doi:10.1007/s12194-022-00660-8 · Cited by 110
Self-citationMatsunaga, Y., Chida, K., Kondo, Y., Kobayashi, K., Kobayashi, M., Minami, K., Suzuki, S., & Asada, Y. (2019) · The British Journal of Radiology · doi:10.1259/bjr.20180290 · Cited by 65
Self-citationBerlin, S. C., Weinert, D. M., Vasavada, P. S., Martinez‐Rios, C., Parikh, R. A., Wien, M. A., Jordan, D. W., & Novak, R. D. (2015) · American Journal of Roentgenology · doi:10.2214/ajr.14.12698 · Cited by 32
Erem, G., Ameda, F., Otike, C., Olwit, W., Mubuuke, A. G., Schandorf, C., Kisolo, A., & Kawooya, M. G. (2022) · BMC Medical Imaging · doi:10.1186/s12880-022-00838-x · Cited by 26
“CT is a known significant contributor to the individual and population radiation exposure dose [1].”
BackgroundMatsunaga, Y., Haba, T., Kobayashi, M., Suzuki, S., Asada, Y., & Chida, K. (2021) · Journal of Applied Clinical Medical Physics · doi:10.1002/acm2.13171 · Cited by 23
Self-citationAssessment of breast dose and cancer risk for young females during CT chest and abdomen examinations
Tamam, N. M., Sulieman, A., Omer, H. B., Toufig, H., Alsaadi, M. J., Salah, H., Mattar, E. H., Khandaker, M. U., & Bradley, D. A. (2022) · Applied Radiation and Isotopes · doi:10.1016/j.apradiso.2022.110452 · Cited by 18
Radiation Exposure to the Brains of Interventional Radiology Staff: A Phantom Study
Ohno, S., Shindo, R., Konta, S., Yamamoto, K., Inaba, Y., & Chida, K. (2024) · Bioengineering · doi:10.3390/bioengineering11111083 · Cited by 15
Self-citationPATIENT EXPOSURE DURING PLAIN RADIOGRAPHY AND MAMMOGRAPHY IN JAPAN IN 1974–2014
Matsunaga, Y., Kawaguchi, A., KOBAYASHI, K. P., Kobayashi, M., Asada, Y., Minami, K., Suzuki, S., & Chida, K. (2017) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncx017 · Cited by 15
Self-citationMasjedi, H., Omidi, R., Zamani, H., Perota, G., & Zare, M. H. (2020) · European Journal of Radiology · doi:10.1016/j.ejrad.2020.108932 · Cited by 13
Novel pregnant model phantoms for measurement of foetal radiation dose in x-ray examinations
Matsunaga, Y., Haba, T., Kobayashi, M., Suzuki, S., Asada, Y., & Chida, K. (2021) · Journal of Radiological Protection · doi:10.1088/1361-6498/ac125c · Cited by 12
Self-citationESTIMATION OF RADIATION DOSES FROM ABDOMINAL COMPUTED TOMOGRAPHY SCANS
Lahham, A., & ALMasri, H. (2018) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncy054 · Cited by 11
Matsunaga, Y., Haba, T., Kobayashi, M., Suzuki, S., Asada, Y., & Chida, K. (2022) · Journal of Applied Clinical Medical Physics · doi:10.1002/acm2.13884 · Cited by 9
Self-citationEvaluation of radiation dose reduction in head CT using the half-dose method
Nakai, Y., Miyazaki, O., Kitamura, M., Imai, R., Okamoto, R., Tsutsumi, Y., Miyasaka, M., Ogiwara, H., Miura, H., Yamada, K., et al. (2023) · Japanese Journal of Radiology · doi:10.1007/s11604-023-01410-5 · Cited by 8
“Funding This article was supported by a grant from the National Center for Child Health and Development, Japan (2019–19).”
BackgroundInfluentialKawauchi, S., Chida, K., Hamada, Y., & Tsuruta, W. (2023) · Tomography · doi:10.3390/tomography9050134 · Cited by 7
Self-citationVOLUME CT DOSE INDEX AND DOSE-LENGTH PRODUCT VALUES ACCORDING TO FACILITY SIZE IN JAPAN
Matsunaga, Y., Kondo, Y., KOBAYASHI, K. P., Kobayashi, M., Minami, K., Suzuki, S., Chida, K., & Asada, Y. (2019) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncz284 · Cited by 7
Self-citationOkamoto, H., Kito, S., Tohyama, N., Yonai, S., Kawamorita, R., Nakamura, M., Fujimoto, T., Tani, S., Yomoda, A., Isobe, T., et al. (2020) · Journal of Radiation Research · doi:10.1093/jrr/rraa088 · Cited by 5
Probability of induced cancers related to computed tomography examinations
Alashban, Y. I., & Shubayr, N. (2023) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2023.111020 · Cited by 5
Kito, S., Suda, Y., Tanabe, S., Takizawa, T., Nagahata, T., Tohyama, N., Okamoto, H., Kodama, T., Fujita, Y., Miyashita, H., et al. (2023) · Journal of Radiation Research · doi:10.1093/jrr/rrad098 · Cited by 6
Effective and organ doses from common CT examinations in one general hospital in Tehran, Iran
Khoramian, D., & Hashemi, B. (2017) · Polish Journal of Medical Physics And Engineering · doi:10.1515/pjmpe-2017-0013 · Cited by 5
“There are lots of similar reports [14, 15] indicat ng relatively a high level of doses contributed from CT exams in commutative doses, an increasing rate of the use of this modality, and finally the lack of a comprehensive s tudy including various CT protocols used nowadays in mul ti detector machines.”
BackgroundMatsunaga, Y., Haba, T., Kobayashi, M., Suzuki, S., Asada, Y., & Chida, K. (2024) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncae058 · Cited by 4
Self-citationMatsunaga, Y., Kobayashi, M., Suzuki, S., Asada, Y., & Chida, K. (2025) · Physica Medica · doi:10.1016/j.ejmp.2025.105021 · Cited by 3
Self-citationPitfalls in chest CT findings of COVID-19 patients infected during hospitalisation
Shirota, G., Sato, Y., Itoh, D., Gonoi, W., Hayashi, T. Y., Sugita, Y., & Makita, K. (2021) · Clinical Imaging · doi:10.1016/j.clinimag.2021.03.017 · Cited by 3
EFFECTIVE DOSES RADIATION TO THE PATIENTS IN EXAMINATIONS PERFORMED IN THREE CT SCANNERS IN BRAZIL†
Ney, M. S. C. J., dos Santos, A. A. S. M. D., Fonseca, G. V. D. S., & Lodi, C. S. (2017) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncx030 · Cited by 3
Yamaguchi, I. (2017) · Japanese Journal of Health Physics · doi:10.5453/jhps.52.27 · Cited by 2
Ota, J., Yokota, H., Higashida, R., Komiya, R., Kawakami, Y., Chida, K., Masuda, Y., & Uno, T. (2022) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncac057 · Cited by 2
Self-citationDruzhinina, P. S., Pozdnyakov, A. V., Kapyrina, Y. N., Ivanov, D. O., Petrenko, Y. V., & Пузырев, В. Г. (2021) · Radiacionnaâ gigiena · doi:10.21514/1998-426x-2021-14-3-91-100 · Cited by 1
Effective Doses of Children During X-Ray Diagnostic Examinations: A Literary Review
Shatskiy, I. G., Druzhinina, P. S., Kapyrina, Y. N., & Осипов, М. В. (2023) · Medical Radiology and radiation safety · doi:10.33266/1024-6177-2023-68-6-27-41 · Cited by 1
Evaluation of Radiation Doses from Computed Tomography Conducted in Al Jouf Region (Saudi Arabia)
Alrowaili, Z. A., & Ashari, M. (2021) · Journal of Medical Imaging and Health Informatics · doi:10.1166/jmihi.2021.3668
Femia, M., Lecchi, M., Vercelli, R., Paternò, M., & Cariati, M. (2023) · Springer eBooks · doi:10.1007/978-3-031-11910-1_4
Untersuchung zum Stellenwert der Sialendoskopie in Deutschland
Kiefer, M., & Justus Liebig University Giessen (2019) · University writing server of the Justus Liebig University Giessen (Justus-Liebig-Universität Gießen) · doi:10.22029/jlupub-14803
Evaluation and Risk Estimation of Adult Head CT in A Police Health Facility
Islamiyah, I., Gumelar, A., Santoso, M. I., Ahya, R. N., Hakikillah, A., Yueniwati, Y., & Widodo, C. S. (2026) · Nusantara Science and Technology Proceedings · doi:10.11594/nstp.2026.5428
“The total effective dose of this study was lower than the effective dose of Radaideh et al. (2023) and Matsunaga (2016) but higher than other countries according to Table 2.”
Metadata
- Authors
- Matsunaga, Y., Kawaguchi, A., Kobayashi, K., Kobayashi, M., Asada, Y., Minami, K., Suzuki, S., & Chida, K.
- Affiliations
- Tohoku University (JP)
- Fujita Health University Hospital (JP)
- Fujita Health University (JP)
- ORCID
- Venue
- The British Journal of Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2016-02
- Volume
- 89
- Issue
- 1058
- Pages
- 20150671
- ISSN
- 0007-1285 (ISSN-L)
- 1748-880X
- PMC
- PMC4985214
- OpenAlex
- W2190596340
- Cited by
- 29
- References
- 30
- Citations by year
- 2025: 1 · 2024: 2 · 2023: 6 · 2022: 5 · 2021: 5 · 2020: 2 · 2019: 1 · 2018: 2 · 2017: 4
- FWCI
- 1.89
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- British Journal of Radiology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Fujita Health University
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Digital Radiography and Breast Imaging
- Keywords
- effective dose, CT examination, pediatric CT, head CT, chest CT, abdominal CT, scanning parameters, patient dosimetry, Japan
- MeSH terms
- Adult, Child, Humans, Japan, Surveys and Questionnaires, Radiation Dosage, Radiometry, Tomography, X-Ray Computed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.