CoChat

Effective radiation doses of CT examinations in Japan: a nationwide questionnaire-based study

Open access

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: The aims of this study were to estimate the effective radiation doses from CT examinations of both adults and children in Japan and to study the impact of various scan parameters on the effective doses. METHODS: A questionnaire, which contained detailed questions on the CT scan parameters employed, was distributed to 3000 facilities throughout Japan. For each scanner protocol, the effective doses for head (non-helical and helical), chest and upper abdomen acquisitions were estimated using ImPACT CT Patient Dosimetry Calculator software v. 1.0.4 (St George's Hospital, London, UK). RESULTS: The mean effective doses for chest and abdominal examinations using 80-110 kV were significantly lower than those using 120 kV. However, there was no statistically significant difference in the mean effective doses for head scans between facilities employing 80-110 kV and 120 kV. In chest and abdominal examinations, the mean effective doses using CT scanners from Western manufacturers [Siemens (Forchheim, Germany), Philips (Eindhoven, Netherlands) and GE Medical Systems (Milwaukee, WI)] were significantly lower than those of examinations using Japanese scanners [Hitachi (Kashiwa, Japan) and Toshiba (Otawara, Tochigi, Japan)], except for in paediatric chest examinations. CONCLUSION: The mean effective doses for adult head, chest and abdominal CT examinations were 2.9, 7.7 and 10.0 mSv, respectively, whereas the corresponding mean effective doses for paediatric examinations were 2.6, 7.1 and 7.7 mSv, respectively. ADVANCES IN KNOWLEDGE: Facilities using CT scanners by Western manufacturers commonly adopt low-tube-voltage techniques, and low-tube-voltage CT may be useful for reducing the radiation doses to the patients, particularly for the body region.

Overview

Integrity signals

Registry

Crossref · 10.1259/bjr.20150671

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 5

  1. The International Commission on Radiological Protection, 2007, Ann ICRP, 37, 1
  2. The International Commission on Radiological Protection, 2007, Ann ICRP, 37, 1
  3. United Nations Scientific Committee on the Effects of Atomic Radiation, 2010, UNSCEAR 2008 Report to the General Assembly with scientific Annexes
  4. Matsunaga Y, 2015, Radiat Prot Dosimetry
  5. Kawaguchi A, 2014, Radiat Prot Dosimetry

Cited by

See all 31

Metadata

Authors
Matsunaga, Y., Kawaguchi, A., Kobayashi, K., Kobayashi, M., Asada, Y., Minami, K., Suzuki, S., & Chida, K.
Affiliations
  • Tohoku University (JP)
  • Fujita Health University Hospital (JP)
  • Fujita Health University (JP)
Venue
The British Journal of Radiology
Published
2016-02
Volume
89
Issue
1058
Pages
20150671
ISSN
  • 0007-1285 (ISSN-L)
  • 1748-880X
OpenAlex
W2190596340
Cited by
29
References
30
Citations by year
2025: 1 · 2024: 2 · 2023: 6 · 2022: 5 · 2021: 5 · 2020: 2 · 2019: 1 · 2018: 2 · 2017: 4
FWCI
1.89
Type
journal article
Language
en
Open access
Locations
  • British Journal of Radiology (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Funders
Fujita Health University
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
  • Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Digital Radiography and Breast Imaging
Keywords
effective dose, CT examination, pediatric CT, head CT, chest CT, abdominal CT, scanning parameters, patient dosimetry, Japan
MeSH terms
Adult, Child, Humans, Japan, Surveys and Questionnaires, Radiation Dosage, Radiometry, Tomography, X-Ray Computed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.