Non-rigid image registration: theory and practice
The DOI matches its Crossref record; 113 of the 113 references it cites were found in a registry or an index.
Abstract
Image registration is an important enabling technology in medical image analysis. The current emphasis is on development and validation of application-specific non-rigid techniques, but there is already a plethora of techniques and terminology in use. In this paper we discuss the current state of the art of non-rigid registration to put on-going research in context and to highlight current and future clinical applications that might benefit from this technology. The philosophy and motivation underlying non-rigid registration is discussed and a guide to common terminology is presented. The core components of registration systems are described and outstanding issues of validity and validation are confronted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A method for registration of 3-D shapes
Besl, P. J., & McKay, N. D. (1992) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.121791 · Cited by 18,103
Press, W. H., Teukolsky, S. A., Vetterling, W. T., & Flannery, B. P. (1994) · Cited by 15,411
Numerical recipes in Pascal: the art of scientific computing
(1990) · Choice Reviews Online · doi:10.5860/choice.27-5158 · Cited by 11,811
Image registration methods: a survey
Zitová, B., & Flusser, J. (2003) · Image and Vision Computing · doi:10.1016/s0262-8856(03)00137-9 · Cited by 6,423 · cited 1×
“For more specific aspects of image registration, the reader is referred to other reviews; there is good technical coverage in Hill et al [1], Brown [15], Lester and Arridge [16], Maintz and Viergever [17] and Zitova and Flusser [18], reviews of cardiac applications in Makela et al [19], nuclear medicine in Hutton et a…”
MethodNonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265 · cited 4×
“Early work by Davis et al [117] and Rueckert et al [25] used elastic-body splines and B-splines, respectively, to correct for motion before and after contrast injection and between scans acquired over time, e.g. to track response to chemotherapy.”
BackgroundMethodInfluentialSelf-citationPrincipal warps: thin-plate splines and the decomposition of deformations
Bookstein, F. L. (1989) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.24792 · Cited by 4,913
A Voxel-Based Morphometric Study of Ageing in 465 Normal Adult Human Brains
Good, C. D., Johnsrude, I. S., Ashburner, J., Henson, R. N. A., Friston, K. J., & Frackowiak, R. S. J. (2001) · NeuroImage · doi:10.1006/nimg.2001.0786 · Cited by 4,561
Numerical Recipes in C: The Art of Scientific Computing.
Birchenhall, C., Press, W. H., Teukolsky, S. A., Vetterling, W. T., & Flannery, B. P. (1994) · The Economic Journal · doi:10.2307/2234664 · Cited by 4,355
A survey of image registration techniques
Brown, L. G. (1992) · ACM Computing Surveys · doi:10.1145/146370.146374 · Cited by 4,057
A survey of medical image registration
Maintz, J. B. A., & Viergever, M. A. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80026-8 · Cited by 3,327
Cited by
Fast free-form deformation using graphics processing units
Modat, M., Ridgway, G. R., Taylor, Z. A., Lehmann, M., Barnes, J., Hawkes, D. J., Fox, N. C., & Ourselin, S. (2010) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2009.09.002 · Cited by 1,085
Generalized Overlap Measures for Evaluation and Validation in Medical Image Analysis
Crum, W. R., Camara, O., & Hill, D. L. G. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.880587 · Cited by 776
“Registration refers to a set of techniques with the shared goal of establishing anatomical or functional correspondence between images acquired at different times, of different subjects, or with different modalities [1], [2].”
BackgroundSelf-citationMedical image registration: a review
Oliveira, F. P. M., & Tavares, J. M. R. S. (2014) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255842.2012.670855 · Cited by 737
MRI Segmentation of the Human Brain: Challenges, Methods, and Applications
Despotović, I., Goossens, B., & Philips, W. (2015) · Computational and Mathematical Methods in Medicine · doi:10.1155/2015/450341 · Cited by 701
Registration of 3D Point Clouds and Meshes: A Survey from Rigid to Nonrigid
Tam, G. K. L., Cheng, Z.-Q., Lai, Y.-K., Langbein, F. C., Liu, Y., Marshall, D., Martin, R. R., Sun, X.-F., & Rosin, P. L. (2013) · IEEE Transactions on Visualization and Computer Graphics · doi:10.1109/tvcg.2012.310 · Cited by 679
Lung Segmentation in Chest Radiographs Using Anatomical Atlases With Nonrigid Registration
Candemir, S., Jaeger, S., Palaniappan, K., Musco, J. P., Singh, R. K., Xue, Z., Karargyris, A., Antani, S., Thoma, G., & McDonald, C. J. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2290491 · Cited by 674
DRAMMS: Deformable registration via attribute matching and mutual-saliency weighting
Ou, Y., Sotiras, A., Paragios, N., & Davatzikos, C. (2011) · Medical Image Analysis · doi:10.1016/j.media.2010.07.002 · Cited by 407
A Review of Geometric Transformations for Nonrigid Body Registration
Holden, M. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.904691 · Cited by 369
Inflammatory Breast Cancer: The Disease, the Biology, the Treatment
Robertson, F. M., Bondy, M., Yang, W., Yamauchi, H., Wiggins, S., Kamrudin, S., Krishnamurthy, S., Le-Petross, H., Bidaut, L., Player, A. N., et al. (2010) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.20082 · Cited by 366
Anjari, M., Srinivasan, L., Allsop, J. M., Hajnal, J. V., Rutherford, M. A., Edwards, A. D., & Counsell, S. J. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.01.035 · Cited by 321
A Partial Intensity Invariant Feature Descriptor for Multimodal Retinal Image Registration
Chen, J., Tian, J., Lee, N., Zheng, J., Smith, R. T., & Laine, A. F. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2042169 · Cited by 311
The ANACONDA algorithm for deformable image registration in radiotherapy
Weistrand, O., & Svensson, S. (2015) · Medical Physics · doi:10.1118/1.4894702 · Cited by 284
Wu, G., Kim, M., Wang, Q., Munsell, B. C., & Shen, D. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2496253 · Cited by 278
Image-guidance for surgical procedures
Peters, T. M. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/14/r01 · Cited by 249
Implementation and evaluation of various demons deformable image registration algorithms on a GPU
Gu, X., Pan, H., Liang, Y., Castillo, R., Yang, D., Choi, D., Castillo, E., Majumdar, A., Guerrero, T., & Jiang, S. B. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/1/012 · Cited by 243
“To realize the clinical application of DIR, much effort has been invested to develop fast and accurate algorithms (Hill et al. , 2001; Crum et al. , 2004; Holden, 2008).”
MethodDeep reinforcement learning in medical imaging: A literature review
Zhou, S. K., Le, H. N., Luu, K., V Nguyen, H., & Ayache, N. (2021) · Medical Image Analysis · doi:10.1016/j.media.2021.102193 · Cited by 215
Mass preserving nonrigid registration of CT lung images using cubic B‐spline
Yin, Y., Hoffman, E. A., & Lin, C. (2009) · Medical Physics · doi:10.1118/1.3193526 · Cited by 207
Navigation in Endoscopic Soft Tissue Surgery: Perspectives and Limitations
Baumhauer, M., Feuerstein, M., Meinzer, H.-P., & Rassweiler, J. (2008) · Journal of Endourology · doi:10.1089/end.2007.9827 · Cited by 181
“A survey of segmentation of ultrasound images is given by Noble et al, 60 and nonrigid image-to-image registration has been reviewed by Crum et al. 61 Regardless of whether navigation targets are defined pre-or intraoperatively, a further registration, referred to as image-to-patient registration, is usually performed…”
Advances in 4D Medical Imaging and 4D Radiation Therapy
Li, G., Citrin, D., Camphausen, K., Mueller, B., Burman, C., Mychalczak, B., Miller, R. W., & Song, Y. (2008) · Technology in Cancer Research & Treatment · doi:10.1177/153303460800700109 · Cited by 177
Islam, S., Aziz, M. T., Nabil, H. R., Jim, J. R., Mridha, M. F., Kabir, M. M., Asai, N., & Shin, J. (2024) · IEEE Access · doi:10.1109/access.2024.3370848 · Cited by 164
Bayesian Characterization of Uncertainty in Intra-subject Non-rigid Registration
Risholm, P., Janoos, F., Norton, I., Golby, A. J., & Wells, W. M. (2013) · Medical Image Analysis · doi:10.1016/j.media.2013.03.002 · Cited by 62
“The usual aim of non-rigid registration (Crum et al., 2004) is to find a high-dimensional displacement field u ( x ) : x ∈ Ω f ↦ u ( x ) + x ∈ Ω m that minimizes an energy function composed of an image dissimilarity measure E s ( u ; f, m) and a regularization term E r ( u ) on the displacements.”
BackgroundMa, D., Holmes, H. E., Cardoso, M. J., Modat, M., Harrison, I. F., Powell, N. M., O’Callaghan, J. M., Ismail, O., Johnson, R. A., O’Neill, M. J., et al. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00011 · Cited by 36
Discriminative segmentation-based evaluation through shape dissimilarity
Konukoglu, E., Glocker, B., Ye, D. H., Criminisi, A., & Pohl, K. M. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2216281 · Cited by 14
Metadata
- Authors
- Crum, W. R., Hartkens, T., & Hill, D. L. G.
- Venue
- The British Journal of Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2004-12
- Volume
- 77
- Issue
- suppl_2
- Pages
- S140-S153
- ISSN
- 0007-1285 (ISSN-L)
- 1748-880X
- OpenAlex
- W2142853128
- Cited by
- 719
- References
- 113
- FWCI
- 18.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.