Non-invasive measurement of perfusion: a critical review of arterial spin labelling techniques
The DOI matches its Crossref record; 101 of the 101 references it cites were found in a registry or an index.
Abstract
The non-invasive nature of arterial spin labelling (ASL) has opened a unique window into human brain function and perfusion physiology. High spatial and temporal resolution makes the technique very appealing not only for the diagnosis of vascular diseases, but also in basic neuroscience where the aim is to develop a more comprehensive picture of the physiological events accompanying neuronal activation. However, low signal-to-noise ratio and the complexity of flow quantification make ASL one of the more demanding disciplines within MRI. In this review, the theoretical background and main implementations of ASL are revisited. In particular, the perfusion quantification methods, including the problems and pitfalls involved, are thoroughly discussed in this article. Finally, a brief summary of applications is provided.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain magnetic resonance imaging with contrast dependent on blood oxygenation.
Ogawa, S., Lee, T. M., Kay, A. R., & Tank, D. W. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.24.9868 · Cited by 6,483 · cited 1×
“Following a neuronal activation paradigm, the classical blood oxygen level dependent (BOLD) contrast [70] is a result of T2* changes due to alterations of CBF and CBV, as well as the cerebral metabolic rate of oxygen uptake (CMRO2).”
BackgroundJUNCTIONAL COMPLEXES IN VARIOUS EPITHELIA
Farquhar, M. G., & Palade, G. E. (1963) · The Journal of Cell Biology · doi:10.1083/jcb.17.2.375 · Cited by 3,635
Kety, S. S., & Schmidt, C. F. (1948) · Journal of Clinical Investigation · doi:10.1172/jci101994 · Cited by 2,059
THE THEORY AND APPLICATIONS OF THE EXCHANGE OF INERT GAS AT THE LUNGS AND TISSUES
KETY, S. S. (1951) · Pharmacological Reviews · doi:10.1016/s0031-6997(25)07246-1 · Cited by 1,663
Detre, J. A., Leigh, J. S., Williams, D. S., & Koretsky, A. P. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910230106 · Cited by 1,571
Magnetic resonance imaging of perfusion using spin inversion of arterial water.
Williams, D. S., Detre, J. A., Leigh, J. S., & Koretsky, A. P. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.1.212 · Cited by 1,546
Østergaard, L., Weisskoff, R. M., Chesler, D. A., Gyldensted, C., & Rosen, B. R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360510 · Cited by 1,512
Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivo
Wolff, S. D., & Balaban, R. S. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910100113 · Cited by 1,482
On the Theory of the Indicator-Dilution Method for Measurement of Blood Flow and Volume
Meier, P., & Zierler, K. L. (1954) · Journal of Applied Physiology · doi:10.1152/jappl.1954.6.12.731 · Cited by 1,274
A general kinetic model for quantitative perfusion imaging with arterial spin labeling
Buxton, R. B., Frank, L. R., Wong, E. C., Siewert, B., Warach, S., & Edelman, R. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400308 · Cited by 1,263
Cited by
Super-resolution Ultrasound Imaging
Christensen-Jeffries, K., Couture, O., Dayton, P. A., Eldar, Y. C., Hynynen, K., Kiessling, F., O'Reilly, M., Pinton, G. F., Schmitz, G., Tang, M.-X., et al. (2020) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2019.11.013 · Cited by 558
Perfusion MRI: The Five Most Frequently Asked Technical Questions
Essig, M., Shiroishi, M. S., Nguyen, T. B., Saake, M., Provenzale, J. M., Enterline, D., Anzalone, N., Dörfler, A., Rovira, À., Wintermark, M., et al. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9543 · Cited by 366
Perfusion MRI: The Five Most Frequently Asked Clinical Questions
Essig, M., Nguyen, T. B., Shiroishi, M. S., Saake, M., Provenzale, J. M., Enterline, D. S., Anzalone, N., Dörfler, A., Rovira, À., Wintermark, M., et al. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9544 · Cited by 344
A neuroradiologist’s guide to arterial spin labeling MRI in clinical practice
Grade, M., Hernandez Tamames, J. A., Pizzini, F. B., Achten, E., Golay, X., & Smits, M. (2015) · Neuroradiology · doi:10.1007/s00234-015-1571-z · Cited by 298
Self-citationCommon Data Elements in Radiologic Imaging of Traumatic Brain Injury
Duhaime, A.-C., Gean, A. D., Haacke, E. M., Hicks, R., Wintermark, M., Mukherjee, P., Brody, D., Latour, L., & Riedy, G. (2010) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2010.07.238 · Cited by 250
Arterial spin labeling in neuroimaging
Petcharunpaisan, S. (2010) · World Journal of Radiology · doi:10.4329/wjr.v2.i10.384 · Cited by 225
Arterial input function in perfusion MRI: A comprehensive review
Calamante, F. (2013) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2013.04.002 · Cited by 219
Mandell, D. M., Han, J. S., Poublanc, J., Crawley, A. P., Stainsby, J. A., Fisher, J. A., & Mikulis, D. J. (2008) · Stroke · doi:10.1161/strokeaha.107.506709 · Cited by 219
Measuring brain perfusion with intravoxel incoherent motion (IVIM): Initial clinical experience
Federau, C., O'Brien, K., Meuli, R., Hagmann, P., & Maeder, P. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24195 · Cited by 204
Durduran, T., Zhou, C., Buckley, E. M., Kim, M. N., Yu, G., Choe, R., Gaynor, J. W., Spray, T. L., Durning, S. M., Mason, S. E., et al. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3425884 · Cited by 196
Common data elements in radiologic imaging of traumatic brain injury
Haacke, E. M., Duhaime, A. C., Gean, A. D., Riedy, G., Wintermark, M., Mukherjee, P., Brody, D. L., DeGraba, T., Duncan, T. D., Elovic, E., et al. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22259 · Cited by 180
Järnum, H., Steffensen, E. G., Knutsson, L., Fründ, E.-T., Simonsen, C. W., Lundbye-Christensen, S., Shankaranarayanan, A., Alsop, D. C., Jensen, F. T., & Larsson, E.-M. (2010) · Neuroradiology · doi:10.1007/s00234-009-0616-6 · Cited by 179
Functional MRI in ADHD: a systematic literature review
Paloyelis, Y., Mehta, M. A., Kuntsi, J., & Asherson, P. (2007) · Expert Review of Neurotherapeutics · doi:10.1586/14737175.7.10.1337 · Cited by 171
Effects of working memory training on functional connectivity and cerebral blood flow during rest
Takeuchi, H., Taki, Y., Nouchi, R., Hashizume, H., Sekiguchi, A., Kotozaki, Y., Nakagawa, S., Miyauchi, C. M., Sassa, Y., & Kawashima, R. (2013) · Cortex · doi:10.1016/j.cortex.2012.09.007 · Cited by 162
Selective reduction of blood flow to white matter during hypercapnia corresponds with leukoaraiosis
Mandell, D. M., Han, J. S., Poublanc, J., Crawley, A. P., Kassner, A., Fisher, J. A., & Mikulis, D. J. (2008) · Stroke · doi:10.1161/strokeaha.107.501692 · Cited by 114
Cerebral oxygen delivery is reduced in newborns with congenital heart disease
Lim, J. M., Kingdom, T., Saini, B., Chau, V., Post, M., Blaser, S., Macgowan, C., Miller, S. P., & Seed, M. (2016) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2016.05.027 · Cited by 86
Magnetic Resonance Imaging in (Near-)Term Infants with Hypoxic-Ischemic Encephalopathy
Parmentier, C. E. J., de Vries, L. S., & Groenendaal, F. (2022) · Diagnostics · doi:10.3390/diagnostics12030645 · Cited by 85
Wolf, R. C., Thomann, P. A., Sambataro, F., Vasic, N., Schmid, M., & Wolf, N. D. (2012) · European Archives of Psychiatry and Clinical Neuroscience · doi:10.1007/s00406-012-0303-1 · Cited by 54
Effects of Fast Simple Numerical Calculation Training on Neural Systems
Takeuchi, H., Nagase, T., Taki, Y., Sassa, Y., Hashizume, H., Nouchi, R., & Kawashima, R. (2016) · Neural Plasticity · doi:10.1155/2016/5940634 · Cited by 5
Metadata
- Authors
- Petersen, E. T., Zimine, I., Ho, Y.-C. L., & Golay, X.
- Venue
- The British Journal of Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2006-08
- Volume
- 79
- Issue
- 944
- Pages
- 688-701
- ISSN
- 0007-1285 (ISSN-L)
- 1748-880X
- OpenAlex
- W2102564020
- Cited by
- 352
- References
- 101
- FWCI
- 11.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.