The DOI matches its Crossref record; 101 of the 101 references it cites were found in a registry or an index.
Non-invasive measurement of perfusion: a critical review of arterial spin labelling techniques
Abstract
The non-invasive nature of arterial spin labelling (ASL) has opened a unique window into human brain function and perfusion physiology. High spatial and temporal resolution makes the technique very appealing not only for the diagnosis of vascular diseases, but also in basic neuroscience where the aim is to develop a more comprehensive picture of the physiological events accompanying neuronal activation. However, low signal-to-noise ratio and the complexity of flow quantification make ASL one of the more demanding disciplines within MRI. In this review, the theoretical background and main implementations of ASL are revisited. In particular, the perfusion quantification methods, including the problems and pitfalls involved, are thoroughly discussed in this article. Finally, a brief summary of applications is provided.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain magnetic resonance imaging with contrast dependent on blood oxygenation.
Ogawa, S., Lee, T. M., Kay, A. R., & Tank, D. W. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.24.9868 · Cited by 6,483
JUNCTIONAL COMPLEXES IN VARIOUS EPITHELIA
Farquhar, M. G., & Palade, G. E. (1963) · The Journal of Cell Biology · doi:10.1083/jcb.17.2.375 · Cited by 3,635
Kety, S. S., & Schmidt, C. F. (1948) · Journal of Clinical Investigation · doi:10.1172/jci101994 · Cited by 2,059
THE THEORY AND APPLICATIONS OF THE EXCHANGE OF INERT GAS AT THE LUNGS AND TISSUES
KETY, S. S. (1951) · Pharmacological Reviews · doi:10.1016/s0031-6997(25)07246-1 · Cited by 1,663
Detre, J. A., Leigh, J. S., Williams, D. S., & Koretsky, A. P. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910230106 · Cited by 1,571
Magnetic resonance imaging of perfusion using spin inversion of arterial water.
Williams, D. S., Detre, J. A., Leigh, J. S., & Koretsky, A. P. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.1.212 · Cited by 1,546
Østergaard, L., Weisskoff, R. M., Chesler, D. A., Gyldensted, C., & Rosen, B. R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360510 · Cited by 1,512
Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivo
Wolff, S. D., & Balaban, R. S. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910100113 · Cited by 1,482
On the Theory of the Indicator-Dilution Method for Measurement of Blood Flow and Volume
Meier, P., & Zierler, K. L. (1954) · Journal of Applied Physiology · doi:10.1152/jappl.1954.6.12.731 · Cited by 1,274
A general kinetic model for quantitative perfusion imaging with arterial spin labeling
Buxton, R. B., Frank, L. R., Wong, E. C., Siewert, B., Warach, S., & Edelman, R. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400308 · Cited by 1,263
Nonlinear Responses in fMRI: The Balloon Model, Volterra Kernels, and Other Hemodynamics
Friston, K. J., Mechelli, A., Turner, R., & Price, C. J. (2000) · NeuroImage · doi:10.1006/nimg.2000.0630 · Cited by 1,130
Mr contrast due to intravascular magnetic susceptibility perturbations
Boxerman, J. L., Hamberg, L. M., Rosen, B. R., & Weisskoff, R. M. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340412 · Cited by 1,008
Kim, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340303 · Cited by 1,001
Quantitative interpretation of magnetization transfer
Henkelman, R. M., Huang, X., Xiang, Q., Stanisz, G. J., Swanson, S. D., & Bronskill, M. J. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290607 · Cited by 734
What is the Correct Value for the Brain-Blood Partition Coefficient for Water?
Herscovitch, P., & Raichle, M. E. (1985) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1985.9 · Cited by 705
Edelman, R. R., Siewert, B., Darby, D. G., Thangaraj, V, Nobre, A. C., Mesulam, M. M., & Warach, S. (1994) · Radiology · doi:10.1148/radiology.192.2.8029425 · Cited by 700
Quantitative imaging of perfusion using a single subtraction (QUIPSS and QUIPSS II)
Wong, E. C., Buxton, R. B., & Frank, L. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390506 · Cited by 689
Comparative Overview of Brain Perfusion Imaging Techniques
Wintermark, M., Sesay, M., Barbier, E., Borbély, K., Dillon, W. P., Eastwood, J. D., Glenn, T. C., Grandin, C. B., Pedraza, S., Soustiel, J.-F., et al. (2005) · Stroke · doi:10.1161/01.str.0000177884.72657.8b · Cited by 592
Wong, E. C., Buxton, R. B., & Frank, L. R. (1997) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199706/08)10:4/5<237::aid-nbm475>3.0.co;2-x · Cited by 584
Luh, W.-M., Wong, E. C., Bandettini, P. A., & Hyde, J. S. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199906)41:6<1246::aid-mrm22>3.0.co;2-n · Cited by 506
Chalela, J. A., Alsop, D. C., Gonzalez-Atavales, J. B., Maldjian, J. A., Kasner, S. E., & Detre, J. A. (2000) · Stroke · doi:10.1161/01.str.31.3.680 · Cited by 481
Mr perfusion studies with t1‐weighted echo planar imaging
Kwong, K. K., Chesler, D. A., Weisskoff, R. M., Donahue, K. M., Davis, T. L., Ostergaard, L., Campbell, T. A., & Rosen, B. R. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340613 · Cited by 477
Methodology of brain perfusion imaging
Barbier, E. L., Lamalle, L., & Décorps, M. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1073 · Cited by 404
Multisection cerebral blood flow MR imaging with continuous arterial spin labeling.
Alsop, D. C., & Detre, J. A. (1998) · Radiology · doi:10.1148/radiology.208.2.9680569 · Cited by 404
Experimental design and the relative sensitivity of BOLD and perfusion fMRI
Aguirre, G. K., Detre, J. A., Zarahn, E., & Alsop, D. C. (2002) · NeuroImage · doi:10.1006/nimg.2001.0990 · Cited by 403
Silver, M. S., Joseph, R. I., & Hoult, D. I. (1985) · Physical Review A · doi:10.1103/physreva.31.2753 · Cited by 400
Warmuth, C., Günther, M., & Zimmer, C. (2003) · Radiology · doi:10.1148/radiol.2282020409 · Cited by 364
Localized cerebral blood flow response at submillimeter columnar resolution
Duong, T. Q., Kim, D.-S., Uğurbil, K., & Kim, S.-G. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.191101098 · Cited by 342
Tissue specific perfusion imaging using arterial spin labeling
Detre, J. A., Zhang, W., Roberts, D. A., Silva, A. C., Williams, D. S., Grandis, D. J., Koretsky, A. P., & Leigh, J. S. (1994) · NMR in Biomedicine · doi:10.1002/nbm.1940070112 · Cited by 335
Ye, F. Q., Berman, K. F., Ellmore, T., Esposito, G., van Horn, J. D., Yang, Y., Duyn, J., Smith, A. M., Frank, J. A., Weinberger, D. R., et al. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200009)44:3<450::aid-mrm16>3.0.co;2-0 · Cited by 317
Arterial spin labeling perfusion fMRI with very low task frequency
Wang, J., Aguirre, G. K., Kimberg, D. Y., Roc, A. C., Li, L., & Detre, J. A. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10437 · Cited by 316
Model‐free arterial spin labeling quantification approach for perfusion MRI
Petersen, E. T., Lim, T., & Golay, X. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20784 · Cited by 305
Self-citationYe, F. Q., Mattay, V. S., Jezzard, P., Frank, J. A., Weinberger, D. R., & McLaughlin, A. C. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370215 · Cited by 294
Technical aspects and utility of fMRI using BOLD and ASL
Detre, J. A., & Wang, J. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00038-x · Cited by 291 · cited 1×
“The ASL signal, on the other hand, is an absolute measure of CBF changes, which makes this technique more reproducible over time, as well as in between subjects [71–73].”
Projection angiograms of blood labeled by adiabatic fast passage
Dixon, W. T., Du, L. N., Faul, D. D., Gado, M., & Rossnick, S. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030311 · Cited by 282
Amiry-Moghaddam, M., Frydenlund, D. S., & Ottersen, O. P. (2004) · Neuroscience · doi:10.1016/j.neuroscience.2004.08.049 · Cited by 275
Arterial transit time imaging with flow encoding arterial spin tagging (FEAST)
Wang, J., Alsop, D. C., Song, H. K., Maldjian, J. A., Tang, K., Salvucci, A. E., & Detre, J. A. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10559 · Cited by 275
Sicard, K., Shen, Q., Brevard, M. E., Sullivan, R., Ferris, C. F., King, J. A., & Duong, T. Q. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200304000-00011 · Cited by 263
Perfusion Imaging Using Arterial Spin Labeling
Golay, X., Hendrikse, J., & Lim, T. C. C. (2004) · Topics in Magnetic Resonance Imaging · doi:10.1097/00002142-200402000-00003 · Cited by 256
Self-citationObata, T., Liu, T. T., Miller, K. L., Luh, W.-M., Wong, E. C., Frank, L. R., & Buxton, R. B. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.08.040 · Cited by 252
Pediatric perfusion imaging using pulsed arterial spin labeling
Wang, J., Licht, D. J., Jahng, G., Liu, C., Rubin, J. T., Haselgrove, J., Zimmerman, R. A., & Detre, J. A. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10372 · Cited by 238
Kim Cmrr, S., & Uĝurbil, K. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380110 · Cited by 220
Noninvasive MRI evaluation of cerebral blood flow in cerebrovascular disease
Detre, J. A., Alsop, D. C., Vives, L. R., Maccotta, L., Teener, J. W., & Raps, E. C. (1998) · Neurology · doi:10.1212/wnl.50.3.633 · Cited by 209
Models of Brain Function in Neuroimaging
Friston, K. J. (2005) · Annual Review of Psychology · doi:10.1146/annurev.psych.56.091103.070311 · Cited by 202
Frequency offset corrected inversion (FOCI) pulses for use in localized spectroscopy
Ordidge, R. J., Wylezinska, M., Hugg, J. W., Butterworth, E., & Franconi, F. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360410 · Cited by 199
Flow Territory Mapping of the Cerebral Arteries With Regional Perfusion MRI
Hendrikse, J., van der Grond, J., Lu, H., van Zijl, P. C. M., & Golay, X. (2004) · Stroke · doi:10.1161/01.str.0000120312.26163.ec · Cited by 164
Self-citationMulti‐Slice MRI of Rat Brain Perfusion During Amphetamine Stimulation Using Arterial Spin Labeling
Silva, A. C., Zhang, W., Williams, D. S., & Koretsky, A. P. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330210 · Cited by 161
Sustained Poststimulus Elevation in Cerebral Oxygen Utilization after Vascular Recovery
Lu, H., Golay, X., Pekar, J. J., & van Zijl, P. C. M. (2004) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/01.wcb.0000124322.60992.5c · Cited by 160
Self-citationNMR Measurement of Perfusion Using Arterial Spin Labeling Without Saturation of Macromolecular Spins
Zhang, W., Silva, A. C., Williams, D. S., & Koretsky, A. P. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330310 · Cited by 158
Multislice imaging of quantitative cerebral perfusion with pulsed arterial spin labeling
Yang, Y., Frank, J. A., Hou, L., Ye, F. Q., McLaughlin, A. C., & Duyn, J. H. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390520 · Cited by 155
Mai, V. M., & Berr, S. S. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199903)9:3<483::aid-jmri18>3.0.co;2-# · Cited by 154
Hoge, R. D., Franceschini, M. A., Covolan, R. J. M., Huppert, T. J., Mandeville, J. B., & Boas, D. A. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.12.032 · Cited by 145
Multislice perfusion and perfusion territory imaging in humans with separate label and image coils
Zaharchuk, G., Ledden, P. J., Kwong, K. K., Reese, T. G., Rosen, B. R., & Wald, L. L. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199906)41:6<1093::aid-mrm4>3.0.co;2-0 · Cited by 141
Calamante, F., Lythgoe, M. F., Pell, G. S., Thomas, D. L., King, M. D., Busza, A. L., Sotak, C. H., Williams, S. R., Ordidge, R. J., & Gadian, D. G. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199903)41:3<479::aid-mrm9>3.0.co;2-2 · Cited by 140
Imaging oxygen consumption in forepaw somatosensory stimulation in rats under isoflurane anesthesia
Liu, Z. M., Schmidt, K. F., Sicard, K. M., & Duong, T. Q. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20148 · Cited by 140
Zhang, W., Williams, D. S., & Koretsky, A. P. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290323 · Cited by 139
Detre, J. A., Samuels, O. B., Alsop, D. C., Gonzalez-Atavales, J. B., Kasner, S. E., & Raps, E. C. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199911)10:5<870::aid-jmri36>3.0.co;2-d · Cited by 127
Floyd, T. F., Ratcliffe, S. J., Wang, J., Resch, B., & Detre, J. A. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10416 · Cited by 124
Belle, V., Kahler, E., Waller, C., Rommel, E., Voll, S., Hiller, K., Bauer, W. R., & Haase, A. (1998) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880080610 · Cited by 121
Sickle Cell Disease: Continuous Arterial Spin-labeling Perfusion MR Imaging in Children
Oğuz, K. K., Golay, X., Pizzini, F. B., Freer, C. A., Winrow, N., Ichord, R., Casella, J. F., van Zijl, P. C. M., & Melhem, E. R. (2003) · Radiology · doi:10.1148/radiol.2272020903 · Cited by 118
Self-citationde BAZELAIRE, C., Rofsky, N. M., Duhamel, G., Michaelson, M. D., George, D. J., & Alsop, D. C. (2005) · Academic Radiology · doi:10.1016/j.acra.2004.12.012 · Cited by 114
Two-Compartment Exchange Model for Perfusion Quantification Using Arterial Spin Tagging
Zhou, J., Wilson, D. A., Ulatowski, J. A., Traystman, R. J., & van Zijl, P. C. M. (2001) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200104000-00013 · Cited by 113
Whole‐brain 3D perfusion MRI at 3.0 T using CASL with a separate labeling coil
Talagala, S. L., Ye, F. Q., Ledden, P. J., & Chesnick, S. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20124 · Cited by 110
In vivo flow territory mapping of major brain feeding arteries
van Laar, P. J., Hendrikse, J., Golay, X., Lu, H., van Osch, M. J. P., & van der Grond, J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.07.011 · Cited by 109
Self-citationImaging blood flow in brain tumors using arterial spin labeling
Silva, A. C., Kim, S., & Garwood, M. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200008)44:2<169::aid-mrm1>3.0.co;2-u · Cited by 108
Lawrence, K. S., Frank, J. A., & McLaughlin, A. C. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200009)44:3<440::aid-mrm15>3.0.co;2-6 · Cited by 108
Schwarzbauer, C., Morrissey, S., & Haase, A. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350413 · Cited by 107
Golay, X., Stuber, M., Pruessmann, K. P., Meier, D., & Boesiger, P. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199903)9:3<454::aid-jmri14>3.0.co;2-b · Cited by 105
Self-citationSiewert, B., Schlaug, G., Edelman, R. R., & Warach, S. J. (1997) · Neurology · doi:10.1212/wnl.48.3.673 · Cited by 102
Kim, S., Tsekos, N. V., & Ashe, J. (1997) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199706/08)10:4/5<191::aid-nbm460>3.0.co;2-r · Cited by 101
The efficiency of adiabatic inversion for perfusion imaging by arterial spin labeling
Maccotta, L., Detre, J. A., & Alsop, D. C. (1997) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199706/08)10:4/5<216::aid-nbm468>3.0.co;2-u · Cited by 93
Quantitation of renal perfusion using arterial spin labeling with FAIR-UFLARE
Karger, N., Biederer, J., Lüsse, S., Grimm, J., Steffens, J.-C., Heller, M., & Glüer, C.-C. (2000) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(00)00155-7 · Cited by 89
Radioactive microsphere validation of a volume localized continuous saturation perfusion measurement
Walsh, E. G., Minematsu, K., Leppo, J. A., & Moore, S. C. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310208 · Cited by 87
Yen, Y., Field, A. S., Martin, E. M., Ari, N., Burdette, J. H., Moody, D. M., & Takahashi, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10140 · Cited by 86
Assessment of brain perfusion with MRI: methodology and application to acute stroke
Grandin, C. B. G. (2003) · Neuroradiology · doi:10.1007/s00234-003-1024-y · Cited by 76
Assessment of brain perfusion with MRI: methodology and application to acute stroke
Grandin, C. B. G. (2004) · Neuroradiology · doi:10.1007/s00234-004-1162-x · Cited by 71
Cerebral Perfusion Imaging by Bolus Tracking
Østergaard, L. (2004) · Topics in Magnetic Resonance Imaging · doi:10.1097/00002142-200402000-00002 · Cited by 70
Ewing, J. R., Wei, L., Knight, R. A., Pawa, S., Nagaraja, T. N., Brusca, T., Divine, G., & Fenstermacher, J. D. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/01.wcb.0000046147.31247.e8 · Cited by 70
Lawrence, K. S., Ye, F. Q., Lewis, B. K., Frank, J. A., & McLaughlin, A. C. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10502 · Cited by 68
Roberts, D. A., Rizi, R. R., Lenkinski, R. E., & LEIGH, J. S. J. (1996) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880060217 · Cited by 68
Hendrikse, J., Lu, H., van der Grond, J., van Zijl, P. C. M., & Golay, X. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10525 · Cited by 67
Self-citationMcLaughlin, A. C., Ye, F. Q., Pekar, J. J., Santha, A. K. S., & Frank, J. A. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370406 · Cited by 57
Continuous artery‐selective spin labeling (CASSL)
Werner, R., Norris, D. G., Alfke, K., Mehdorn, H. M., & Jansen, O. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20475 · Cited by 54
Four‐phase single‐capillary stepwise model for kinetics in arterial spin labeling MRI
Li, K., Zhu, X., Hylton, N. M., Jahng, G., Weiner, M. W., & Schuff, N. W. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20390 · Cited by 53
STAR‐HASTE: Perfusion imaging without magnetic susceptibility artifact
Chen, Q., Siewert, B., Bly, B. M., Warach, S. J., & Edelman, R. R. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380308 · Cited by 50
Lythgoe, M. F., Thomas, D. L., Calamante, F., Pell, G. S., King, M. D., Busza, A. L., Sotak, C. H., Williams, S. R., Ordidge, R. J., & Gadian, D. G. (2000) · Magnetic Resonance in Medicine · Cited by 47
Zaharchuk, G., Yamada, M., Sasamata, M., Jenkins, B. G., Moskowitz, M. A., & Rosen, B. R. (2000) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200009000-00009 · Cited by 44
Lawrence, K. S., Ye, F. Q., Lewis, B. K., Weinberger, D. R., Frank, J. A., & McLaughlin, A. C. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10111 · Cited by 42
FAIR excluding radiation damping (FAIRER)
Zhou, J., Mori, S., & van Zijl, P. C. M. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400511 · Cited by 42
Noninvasive perfusion imaging of human brain tumors with EPISTAR
Gaa, J., Warach, S. J., Wen, P. Y., Thangaraj, V., Wielopolski, P. A., & Edelman, R. R. (1996) · European Radiology · doi:10.1007/bf00182486 · Cited by 38
Perioperative changes in cerebral blood flow after cardiac surgery: influence of anemia and aging
Floyd, T. F., McGarvey, M. L., Ochroch, E. A., Cheung, A. T., Augoustides, J. A., Bavaria, J. E., Acker, M. A., Pochettino, A. A., & Detre, J. A. (2003) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(03)01074-9 · Cited by 35
Magnetic resonance prediction of outcome after thrombolytic treatment
Pillekamp, F., Grüne, M., Brinker, G., Franke, C., Uhlenküken, U., Hoehn, M., & Hossmann, K. (2001) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(01)00293-4 · Cited by 33
Magnetic resonance imaging of perfusion in rat cerebral 9L tumor after nicotinamide administration
Brown, S. L., Ewing, J. R., Kolozsvary, A. J. J., Butt, S., Cao, Y., & Kim, J. H. (1999) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(98)00422-2 · Cited by 31
Water filtration and diffusion across the blood brain barrier in man.
Paulson, O. B., Hertz, M. M., Tg, B., & Lassen, N. A. (1977) · PubMed · Cited by 26
Werner, R., Norris, D. G., Alfke, K., Mehdorn, H. M., & Jansen, O. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20443 · Cited by 22
BASE imaging: A new spin labeling technique for measuring absolute perfusion changes
Schwarzbauer, C., & Heinke, W. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390508 · Cited by 15
A model of the inversion process in an arterial inversion experiment
Marro, K. I., Hayes, C. E., & Kushmerick, M. J. (1997) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199710)10:7<324::aid-nbm491>3.0.co;2-l · Cited by 14
Wang, Z., Gu, H., Silbersweig, D., et al. (2002) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(02)00525-8 · Cited by 11
Robertson, C., Hendrich, K. S., Kochanek, P. M., Jackson, E. K., Melick, J. A., Graham, S. H., Marion, D. W., Williams, D. S., & Ho, C. (2000) · Springer eBooks · doi:10.1007/978-3-7091-6346-7_37 · Cited by 9
Wheeler-Kingshott (2000) · doi:10.1002/1522-2594(200011)44:5
Grieve (2000) · doi:10.1002/(sici)1522-2594(200005)43:5
Cited by
Super-resolution Ultrasound Imaging
Christensen-Jeffries, K., Couture, O., Dayton, P. A., Eldar, Y. C., Hynynen, K., Kiessling, F., O'Reilly, M., Pinton, G. F., Schmitz, G., Tang, M.-X., et al. (2020) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2019.11.013 · Cited by 558
Perfusion MRI: The Five Most Frequently Asked Technical Questions
Essig, M., Shiroishi, M. S., Nguyen, T. B., Saake, M., Provenzale, J. M., Enterline, D., Anzalone, N., Dörfler, A., Rovira, À., Wintermark, M., et al. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9543 · Cited by 366
Perfusion MRI: The Five Most Frequently Asked Clinical Questions
Essig, M., Nguyen, T. B., Shiroishi, M. S., Saake, M., Provenzale, J. M., Enterline, D. S., Anzalone, N., Dörfler, A., Rovira, À., Wintermark, M., et al. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9544 · Cited by 344
A neuroradiologist’s guide to arterial spin labeling MRI in clinical practice
Grade, M., Hernandez Tamames, J. A., Pizzini, F. B., Achten, E., Golay, X., & Smits, M. (2015) · Neuroradiology · doi:10.1007/s00234-015-1571-z · Cited by 298
Self-citationFunctional MRI in ADHD: a systematic literature review
Paloyelis, Y., Mehta, M. A., Kuntsi, J., & Asherson, P. (2007) · Expert Review of Neurotherapeutics · doi:10.1586/14737175.7.10.1337 · Cited by 171
Metadata
- Authors
- Petersen, E. T., Zimine, I., Ho, Y.-C. L., & Golay, X.
- Venue
- The British Journal of Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2006-08
- Volume
- 79
- Issue
- 944
- Pages
- 688-701
- ISSN
- 0007-1285 (ISSN-L)
- 1748-880X
- OpenAlex
- W2102564020
- Cited by
- 352
- References
- 101
- FWCI
- 11.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.