Is CO2 an Indoor Pollutant? Direct Effects of Low-to-Moderate CO2 Concentrations on Human Decision-Making Performance
Open accessAbstract
Background: Associations of higher indoor carbon dioxide (CO2) concentrations with impaired work performance, increased health symptoms, and poorer perceived air quality have been attributed to correlation of indoor CO2 with concentrations of other indoor air pollutants that are also influenced by rates of outdoor-air ventilation. Objectives: We assessed direct effects of increased CO2, within the range of indoor concentrations, on decision making. Methods: Twenty-two participants were exposed to CO2 at 600, 1,000, and 2,500 ppm in an office-like chamber, in six groups. Each group was exposed to these conditions in three 2.5-hr sessions, all on 1 day, with exposure order balanced across groups. At 600 ppm, CO2 came from outdoor air and participants’ respiration. Higher concentrations were achieved by injecting ultrapure CO2. Ventilation rate and temperature were constant. Under each condition, participants completed a computer-based test of decision-making performance as well as questionnaires on health symptoms and perceived air quality. Participants and the person administering the decision-making test were blinded to CO2 level. Data were analyzed with analysis of variance models. Results: Relative to 600 ppm, at 1,000 ppm CO2, moderate and statistically significant decrements occurred in six of nine scales of decision-making performance. At 2,500 ppm, large and statistically significant reductions occurred in seven scales of decision-making performance (raw score ratios, 0.06–0.56), but performance on the focused activity scale increased. Conclusions: Direct adverse effects of CO2 on human performance may be economically important and may limit energy-saving reductions in outdoor air ventilation per person in buildings. Confirmation of these findings is needed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Low ventilation rates and CO2 concentrations normally found in office buildings (approximately 1,000 ppm) have been recently associated with impairment in multiple domains of high-order cognitive function [45,46].”
From Reduced cognitive function during a heat wave among residents of non-air-conditioned buildings: An observational study of young adults in the summer of 2016 (2018) · cites this paper as [45]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Seppanen, O. A., Fisk, W. J., & Mendell, M. J. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.00003.x · Cited by 876
Self-citationWARGOCKI, P., WYON, D. P., SUNDELL, J., CLAUSEN, G., & FANGER, P. O. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004222.x · Cited by 688
Associations between classroom CO2 concentrations and student attendance in Washington and Idaho
Shendell, D. G., Prill, R., Fisk, W. J., Apte, M. G., Blake, D., & Faulkner, D. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00251.x · Cited by 462
Self-citationCarbon Dioxide and the Cerebral Circulation
Brian, J. E. (1998) · Anesthesiology · doi:10.1097/00000542-199805000-00029 · Cited by 395
MILTON, D. K., GLENCROSS, P. M., & WALTERS, M. D. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004212.x · Cited by 364
Behavior in the complex environment.
Streufert, S., & Streufert, S. C. (1978) · Cited by 302
Self-citationPhysiological Impact of the N95 Filtering Facepiece Respirator on Healthcare Workers
Roberge, R. J., Coca, A., Williams, W. J., Powell, J. B., & Palmiero, A. J. (2010) · Respiratory Care · doi:10.4187/respcare.10550569 · Cited by 276
Woods, S. W. (1988) · Archives of General Psychiatry · doi:10.1001/archpsyc.1988.01800250051007 · Cited by 265 · cited 2×
“Inhaled CO2 at concentrations of tens of thousands of ppm has been associated with changes in respiration, cerebral blood flow, cardiac output, and anxiety (Brian Jr 1998; Kaye et al. 2004; Lipsett et al. 1994; Roberge et al. 2010; Woods et al. 1988).”
BackgroundErdmann, C. A., & Apte, M. G. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00298.x · Cited by 147 · cited 1×
“…perceptions of poor air quality, increased prevalence of acute health symptoms (e.g., headache, mucosal irritation), slower work performance, and increased absence (Erdmann and Apte 2004; Federspiel et al. 2004; Milton et al. 2000; Seppanen et al. 1999; Shendell et al. 2004; Wargocki et al. 2000).”
BackgroundKaye, J., Buchanan, F., Kendrick, A. H., Johnson, P. L., Lowry, C. A., Bailey, J., Nutt, D., & Lightman, S. L. (2004) · Journal of Neuroendocrinology · doi:10.1111/j.0953-8194.2004.01158.x · Cited by 134 · cited 2×
“CO2 is the key regulator of respiration and arousal of behavioral states in humans (Kaye et al. 2004).”
Background
Research works printed but not linked: 7
- ACGIH (American Conference of Governmental Industrial Hygienists), 2011, TLVs and BEIs
- Corsi, 2002, Carbon dioxide levels and dynamics in elementary schools: results of the TESIAS Study. In: Indoor Air 2002, 9th International Conference on Indoor Air Quality and Climate (Levin H, ed)
- Knibbs, 2008, On-road quantification of the key characteristics of automobile HVAC systems in relation to in-cabin submicrometer particle pollution [Abstract]. In: 11th International Conference on Indoor Air Quality and Climate: Indoor Air 2008. Copenhagen, Denmark.
- Mudarri, 1997, Potential correction factors for interpreting CO2 measurements in buildings., ASHRAE Transactions, 103, 244
- Persily, 1997, Evaluating building IAQ and ventilation with carbon dioxide., ASHRAE Transactions, 103, 193
- Satish, 2009, Novel assessment of psychiatry residents: SMS simulations. Accreditation Council for Graduate Medical Education (ACGME) Bulletin, 18–23 January.
- Swezey, 1998, Preliminary development of a computer-based team performance assessment simulation., Int J Cogn Ergonomics, 2, 163
Cited by
Allen, J. G., MacNaughton, P., Satish, U., Santanam, S., Vallarino, J., & Spengler, J. D. (2016) · Environmental Health Perspectives · doi:10.1289/ehp.1510037 · Cited by 977
“However, this conventional thinking is being challenged as the evidence mounts for CO2 as a direct pollutant, not just a marker for other pollutants (Satish et al. 2012).”
BackgroundMethodInfluentialSelf-citationDirect human health risks of increased atmospheric carbon dioxide
Jacobson, T. A., Kler, J. S., Hernke, M. T., Braun, R. K., Meyer, K. C., & Funk, W. E. (2019) · Nature Sustainability · doi:10.1038/s41893-019-0323-1 · Cited by 609
Carbon dioxide generation rates for building occupants
Persily, A., & de Jonge, L. (2017) · Indoor Air · doi:10.1111/ina.12383 · Cited by 566
A state–of–the-art review on indoor air pollution and strategies for indoor air pollution control
González-Martín, J., Kraakman, N. J. R., Pérez, C., Lebrero, R., & Muñoz, R. (2021) · Chemosphere · doi:10.1016/j.chemosphere.2020.128376 · Cited by 562
Azuma, K., Kagi, N., Yanagi, U., & Osawa, H. (2018) · Environment International · doi:10.1016/j.envint.2018.08.059 · Cited by 403
Zhang, X., Wargocki, P., Lian, Z., & Thyregod, C. (2017) · Indoor Air · doi:10.1111/ina.12284 · Cited by 360
“…fatigue, eye, nose and respiratory tract symptoms even in buildings where CO 2 levels were below 5,000 ppm; the prevalence of symptoms continued to decrease with the CO 2 level even below 800 ppm (e.g., Myhrvold et al., 1996; Seppänen et al., 1999; Tsai et al., 2012; Norbäck et al., 2013).”
BackgroundThe ventilation problem in schools: literature review
Fisk, W. J. (2017) · Indoor Air · doi:10.1111/ina.12403 · Cited by 333
“15 with all other factors constant, improve cognitive performance([49-52]).”
BackgroundSelf-citationProviding better thermal and air quality conditions in school classrooms would be cost-effective
Wargocki, P., & Wyon, D. P. (2013) · Building and Environment · doi:10.1016/j.buildenv.2012.10.007 · Cited by 309
Volatile Organic Compound Emissions from Humans Indoors
Tang, X., Misztal, P. K., Nazaroff, W. W., & Goldstein, A. H. (2016) · Environmental Science & Technology · doi:10.1021/acs.est.6b04415 · Cited by 295
Wargocki, P., & Wyon, D. P. (2017) · Building and Environment · doi:10.1016/j.buildenv.2016.11.020 · Cited by 290
“Experiments by Satish et al. (2012) exposing subjects for 2.5 hours to CO2 levels that had been raised by releasing chemically pure CO2 and by Allen et al. (2015), who exposed subjects similarly for an entire working day, then demonstrated conclusively that exposures to CO2 at levels as low as…”
InfluentialThe next generation of low-cost personal air quality sensors for quantitative exposure monitoring
Piedrahita, R., Xiang, Y., Masson, N., Ortega, J., Collier, A., Jiang, Y., Li, K., Dick, R. P., Lv, Q., Hannigan, M., et al. (2014) · Atmospheric Measurement Techniques · doi:10.5194/amt-7-3325-2014 · Cited by 283
“Elevated concentrations have also been 20 found to affect decision-making and exam performance (Satish et al., 2012).”
BackgroundWolkoff, P., Azuma, K., & Carrer, P. (2021) · International Journal of Hygiene and Environmental Health · doi:10.1016/j.ijheh.2021.113709 · Cited by 279
Dong, H., Xue, M., Xiao, Y., & Liu, Y. (2021) · Science of The Total Environment · doi:10.1016/j.scitotenv.2020.143688 · Cited by 255
Persily, A. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.02.026 · Cited by 249
“A chamber study of individuals completing computer-based tests showed statistically significant decreases in decision-making performance at CO2 concentrations as low as 1800 mg/m(3) [54].”
BackgroundHow indoor environmental quality affects occupants’ cognitive functions: A systematic review
Wang, C., Zhang, F., Wang, J., Doyle, J. K., Hancock, P. A., Mak, C. M., & Liu, S. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.107647 · Cited by 243
Sick building syndrome: are we doing enough?
Ghaffarianhoseini, A., AlWaer, H., Omrany, H., Ghaffarianhoseini, A., Alalouch, C., Clements-Croome, D., & Tookey, J. (2018) · Architectural Science Review · doi:10.1080/00038628.2018.1461060 · Cited by 238
Li, S., Dong, Y., Zhou, J., Liu, Y., Wang, J., Gao, X., Han, Y., Qi, P., & Wang, B. (2018) · Energy & Environmental Science · doi:10.1039/c8ee00415c · Cited by 226
The impact of working in a green certified building on cognitive function and health
MacNaughton, P., Satish, U., Laurent, J. G. C., Flanigan, S., Vallarino, J., Coull, B., Spengler, J. D., & Allen, J. G. (2017) · Building and Environment · doi:10.1016/j.buildenv.2016.11.041 · Cited by 219
“More detailed methodology about the cognitive testing is described elsewhere [19,29,39].”
BackgroundMethodSelf-citationMa, N., Aviv, D., Guo, H., & Braham, W. W. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2020.110436 · Cited by 217
Pleil, J. D., Ariel Geer Wallace, M., Davis, M. D., & Matty, C. M. (2021) · Journal of Breath Research · doi:10.1088/1752-7163/ac2589 · Cited by 212
Cedeño Laurent, J. G., Williams, A., Oulhote, Y., Zanobetti, A., Allen, J. G., & Spengler, J. D. (2018) · PLoS Medicine · doi:10.1371/journal.pmed.1002605 · Cited by 205
Kumar, P., Skouloudis, A. N., Bell, M., Viana, M., Carotta, M. C., Biskos, G., & Morawska, L. (2016) · Science of The Total Environment · doi:10.1016/j.scitotenv.2016.04.032 · Cited by 201
Valladares, W., Galindo, M., Gutiérrez, J., Wu, W.-C., Liao, K.-K., Liao, J.-C., Lu, K.-C., & Wang, C.-C. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.03.038 · Cited by 200
Children's well-being at schools: Impact of climatic conditions and air pollution
Salthammer, T., Uhde, E., Schripp, T., Schieweck, A., Morawska, L., Mazaheri, M., Clifford, S., He, C., Buonanno, G., Querol, X., et al. (2016) · Environment International · doi:10.1016/j.envint.2016.05.009 · Cited by 198
Effects of Classroom Ventilation Rate and Temperature on Students’ Test Scores
Haverinen-Shaughnessy, U., & Shaughnessy, R. J. (2015) · PLOS ONE · doi:10.1371/journal.pone.0136165 · Cited by 194
“Low ventilation rates can result in an increased exposure to indoor air pollutants, assumed to be the primary reason for adverse effects on occupant health and performance [5–7].”
BackgroundIndoor CO 2 concentrations and cognitive function: A critical review
Du, B., Tandoc, M. C., Mack, M. L., & Siegel, J. A. (2020) · Indoor Air · doi:10.1111/ina.12706 · Cited by 190
Indoor Air Quality Assessment Using a CO2 Monitoring System Based on Internet of Things
Marques, G., Ferreira, C. R., & Pitarma, R. (2019) · Journal of Medical Systems · doi:10.1007/s10916-019-1184-x · Cited by 182
Indoor air quality and academic performance
Stafford, T. M. (2015) · Journal of Environmental Economics and Management · doi:10.1016/j.jeem.2014.11.002 · Cited by 178
The self-powered CO2 gas sensor based on gas discharge induced by triboelectric nanogenerator
Zhao, K., Gu, G., Zhang, Y., Zhang, B., Yang, F., Zhao, L., Zheng, M., Cheng, G., & Du, Z. (2018) · Nano Energy · doi:10.1016/j.nanoen.2018.09.057 · Cited by 179
Liu, W., Zhong, W., & Wargocki, P. (2017) · Building and Environment · doi:10.1016/j.buildenv.2016.12.020 · Cited by 169
“Carbon dioxide is gradually increasing in ambient air and there is a new evidence that the concentrations below occupational level set at 5,000 ppm [14] may influence the ability to make decisions [15,16] although these levels have not been shown to cause negative effects on health or comfort, or result in measurable…”
Law, J., Van Baalen, M., Foy, M., Mason, S. S., Mendez, C., Wear, M. L., Meyers, V. E., & Alexander, D. (2014) · Journal of Occupational & Environmental Medicine · doi:10.1097/jom.0000000000000158 · Cited by 168
Zhang, X., Wargocki, P., & Lian, Z. (2017) · Indoor Air · doi:10.1111/ina.12286 · Cited by 164
Vehviläinen, T., Lindholm, H., Rintamäki, H., Pääkkönen, R., Hirvonen, A., Niemi, O., & Vinha, J. (2016) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2015.1076160 · Cited by 163
“These findings are in accordance with the recent study reporting that even a relatively low ambient CO2 level (600–1000 ppm) is related to a reduction in the decisionmaking performance but not to focused activity.[12] The increased somnolence is supported by the finding in HRV.”
ResultBen-David, T., & Waring, M. S. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.05.007 · Cited by 159
Liu, Z., Ma, S., Cao, G., Meng, C., & He, B. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.07.050 · Cited by 146
Maddalena, R. L., Mendell, M. J., Eliseeva, K., Chan, W. R., Sullivan, D. P., Russell, M., Satish, U., & Fisk, W. J. (2014) · Indoor Air · doi:10.1111/ina.12149 · Cited by 153
Self-citationContribution of human-related sources to indoor volatile organic compounds in a university classroom
Liu, S., Li, R., Wild, R. J., Warneke, C., de Gouw, J. A., Brown, S. S., Miller, S. L., Luongo, J. C., Jimenez, J. L., & Ziemann, P. J. (2015) · Indoor Air · doi:10.1111/ina.12272 · Cited by 158
Energy and comfort assessment in educational building: Case study in a French university campus
Allab, Y., Pellegrino, M., Guo, X., Nefzaoui, E., & Kindinis, A. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.11.028 · Cited by 150
Self-powered environmental monitoring via a triboelectric nanogenerator
Chang, A., Uy, C., Xiao, X., Xiao, X., & Chen, J. (2022) · Nano Energy · doi:10.1016/j.nanoen.2022.107282 · Cited by 148
Association of carbon dioxide with indoor air pollutants and exceedance of health guideline values
Ramalho, O., Wyart, G., Mandin, C., Blondeau, P., Cabanes, P., Leclerc, N., Mullot, J., Boulanger, G., & Redaelli, M. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.03.018 · Cited by 143
CO2 in indoor environments: From environmental and health risk to potential renewable carbon source
López, L. R., Dessì, P., Cabrera‐Codony, A., Rocha-Melogno, L., Kraakman, B., Naddeo, V., Balaguer, M. D., & Puig, S. (2022) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2022.159088 · Cited by 163
Environmental perceptions and health before and after relocation to a green building
MacNaughton, P., Spengler, J. D., Vallarino, J., Santanam, S., Satish, U., & Allen, J. G. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.05.011 · Cited by 132
“The more strategic domains of cognitive function, such as crisis response, information usage, and strategy were the most significantly impacted [18,30].”
BackgroundSelf-citationSnow, S., Boyson, A., Paas, K. H. W., Gough, H., King, M., Barlow, J. F., Noakes, C. J., & schraefel, M. C. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.04.010 · Cited by 146
“2260 ppm [12] 2500 ppm [7] or 3000 ppm [1,2,9].”
MethodExposure to indoor air pollutants during physical activity in fitness centers
Ramos, C. A., Wolterbeek, H. T., & Almeida, S. M. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.08.026 · Cited by 138
“Previous studies showed that changes in CO2 concentrations were associated with statistically significant and meaningful reductions in decisionmaking performance [59].”
BackgroundTowards practical indoor air phytoremediation: A review
Pettit, T. J., Irga, P. J., & Torpy, F. R. (2018) · Chemosphere · doi:10.1016/j.chemosphere.2018.06.048 · Cited by 133
Low Level Carbon Dioxide Indoors—A Pollution Indicator or a Pollutant? A Health-Based Perspective
Lowther, S. D., Dimitroulopoulou, S., Foxall, K., Shrubsole, C., Cheek, E., Gadeberg, B., & Sepai, O. (2021) · Environments · doi:10.3390/environments8110125 · Cited by 142
“Satish et al., 2012 1000 Lab: Moderate and statistically significant reductions were seen for 6 out of9 markers of decision-making performance relative to 600 ppm. 2500 Lab: Large and statistically significant reductions were seen for 7 out of 9 of the markers.”
BackgroundExploring the consequences of climate change for indoor air quality
Nazaroff, W. W. (2013) · Environmental Research Letters · doi:10.1088/1748-9326/8/1/015022 · Cited by 150
“A recent study by (Satish et al 2012) is one of the first investigations to isolate CO2 from other contaminants and to explore its consequences for human health and well being.”
BackgroundIndoor air quality (IAQ) in naturally-ventilated primary schools in the UK: Occupant-related factors
Korsavi, S. S., Montazami, A., & Mumovic, D. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.106992 · Cited by 127
Shan, X. J., Yang, E., Zhou, J. Z., & Chang, V. W.-C. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.12.004 · Cited by 128
Boubekri, M., Lee, J., MacNaughton, P., Woo, M. K., Schuyler, L., Tinianov, B. D., & Satish, U. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17093219 · Cited by 140
Self-citationProbability of occupant operation of windows during transition seasons in office buildings
Li, N., Li, J., Fan, R., & Jia, H. (2014) · Renewable Energy · doi:10.1016/j.renene.2014.05.065 · Cited by 118
Zhang, X., Wargocki, P. L., & Lian, Z. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.02.014 · Cited by 119
Amine-Functionalized MIL-101 Monoliths for CO 2 Removal from Enclosed Environments
Lawson, S., Griffin, C., Rapp, K., Rownaghi, A. A., & Rezaei, F. (2019) · Energy & Fuels · doi:10.1021/acs.energyfuels.8b04508 · Cited by 116
Tang, H., Ding, Y., & Singer, B. C. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.106462 · Cited by 121
“30 negatively impact performance on complex cognitive tasks [51,57], whereas others have found that CO2 did not impact performance on simpler cognitive tasks or perceived IAQ [52,58].”
BackgroundNazaroff, W. W., & Weschler, C. J. (2020) · Indoor Air · doi:10.1111/ina.12670 · Cited by 124
Forecasting office indoor CO2 concentration using machine learning with a one-year dataset
Kallio, J., Tervonen, J., Räsänen, P., Mäkynen, R., Koivusaari, J., & Peltola, J. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.107409 · Cited by 108
Johnson, D. L., Lynch, R. A., Floyd, E. L., Wang, J., & Bartels, J. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.03.040 · Cited by 117
Current State of Indoor Air Phytoremediation Using Potted Plants and Green Walls
Bandehali, S., Miri, T., Onyeaka, H. N., & Kumar, P. (2021) · Atmosphere · doi:10.3390/atmos12040473 · Cited by 109
“A study by [13] shows that even at low and moderate CO2 levels (1000 and 2500 ppm), significant decrements occur in decision-making performance.”
BackgroundShan, X., Zhou, J. Z., Chang, V. W.-C., & Yang, E. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.03.025 · Cited by 101
Traffic-related Air Pollution and Attention in Primary School Children
Sunyer, J., Suades-González, E., García‐Esteban, R., Rivas, I., Pujol, J., Álvarez‐Pedrerol, M., Forns, J., Querol, X., & Basagaña, X. (2016) · Epidemiology · doi:10.1097/ede.0000000000000603 · Cited by 108
Building energy audit, thermal comfort, and IAQ assessment of a school building: A case study
Merabtine, A., Maalouf, C., Hawila, A. A.-W., Martaj, N., & Polidori, G. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.09.015 · Cited by 99
Pacitto, A., Amato, F., Moreno, T., Pandolfi, M., Fonseca, A. S., Mazaheri, M., Stabile, L., Buonanno, G., & Querol, X. (2019) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2019.135673 · Cited by 103
Haddad, S., Synnefa, A., Padilla-Marcos, M. Á., Paolini, R., Delrue, S., Prasad, D. K., & Santamouris, M. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.110838 · Cited by 100
Maula, H., Hongisto, V. O., Naatula, V., Haapakangas, A., & Koskela, H. (2017) · Indoor Air · doi:10.1111/ina.12387 · Cited by 105
“051 N- backb Speed (reaction time, ms) 600 (23) 580 (21) .”
Ho, R., Zhang, M. W., Ho, C. S. H., Pan, F., Lu, Y., & Sharma, V. K. (2014) · BMC Psychiatry · doi:10.1186/1471-244x-14-81 · Cited by 108
“[24] emphasized the need to measure perceived air quality as it is known to be associated with higher indoor pollutant levels, which in turn, associated with impaired work performance and increased health symptoms.”
BackgroundStabile, L., Buonanno, G., Frattolillo, A., & Dell’Isola, M. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.04.001 · Cited by 99
Alawneh, R., Ghazali, F. E. M., Ali, H. H., & Sadullah, A. F. M. (2019) · Sustainable Cities and Society · doi:10.1016/j.scs.2019.101612 · Cited by 114
Fernández-Agüera, J., Domínguez-Amarillo, S., Alonso, C., & Martín-Consuegra, F. (2019) · Energy and Buildings · doi:10.1016/j.enbuild.2019.06.052 · Cited by 94
Fossil Fuel Combustion Is Driving Indoor CO2 Toward Levels Harmful to Human Cognition
Karnauskas, K. B., Miller, S. L., & Schapiro, A. C. (2020) · GeoHealth · doi:10.1029/2019gh000237 · Cited by 102
Allen, J. G., MacNaughton, P., Laurent, J. G. C., Cao, X., Flanigan, S. S., Vallarino, J., Rueda, F., Donnelly-McLay, D., & Spengler, J. D. (2018) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/s41370-018-0055-8 · Cited by 98
Carbon dioxide absorption spectroscopy with a mid-infrared silicon photonic waveguide
Briano, F. O., Errando-Herranz, C., Rödjegård, H., Martin, H., Sohlstrom, H. B., & Gylfason, K. B. (2019) · Optics Letters · doi:10.1364/ol.45.000109 · Cited by 92
Capsules of Reactive Ionic Liquids for Selective Capture of Carbon Dioxide at Low Concentrations
Lee, Y., Edgehouse, K. J., Klemm, A., Mao, H., Pentzer, E., & Gurkan, B. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c01622 · Cited by 90
Varjo, J., Hongisto, V. O., Haapakangas, A., Maula, H., Koskela, H., & Hyönä, J. (2015) · Journal of Environmental Psychology · doi:10.1016/j.jenvp.2015.08.001 · Cited by 100
“In contrast, decision-making performance has been shown to decline by high carbon dioxide (CO2) concentrations (Satish et al., 2012).”
BackgroundHeart Rate Variability and Performance of Commercial Airline Pilots during Flight Simulations
Cao, X., MacNaughton, P., Cadet, L. R., Laurent, J. G. C., Flanigan, S. S., Vallarino, J., Donnelly-McLay, D., Christiani, D. C., Spengler, J. D., & Allen, J. G. (2019) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph16020237 · Cited by 101
Marques, G., Miranda, N., Bhoi, A. K., García-Zapirain, B., Hamrioui, S., & Díez, I. D. L. T. (2020) · Sensors · doi:10.3390/s20030720 · Cited by 96
“Numerous authorities define the thresholds for CO2 in different countries [53,54].”
BackgroundScully, R. R., Basner, M., Nasrini, J., Lam, C., Hermosillo, E., Gur, R. C., Moore, T. M., Alexander, D. J., Satish, U., & Ryder, V. E. (2019) · npj Microgravity · doi:10.1038/s41526-019-0071-6 · Cited by 98
Self-citationLu, X., Pang, Z., Fu, Y., & O’Neill, Z. D. (2022) · Building and Environment · doi:10.1016/j.buildenv.2022.109116 · Cited by 98
Magzamen, S. L., Mayer, A., Barr, S., Bohren, L., Dunbar, B. H., Manning, D. T., Reynolds, S. J., Schaeffer, J. W., Suter, J. F., & Cross, J. E. (2017) · Journal of School Health · doi:10.1111/josh.12505 · Cited by 92
The German approach to regulate indoor air contaminants
Fromme, H., Dębiak, M., Sagunski, H., Röhl, C., Kraft, M., & Kolossa‐Gehring, M. (2019) · International Journal of Hygiene and Environmental Health · doi:10.1016/j.ijheh.2018.12.012 · Cited by 88
A ventilation intervention study in classrooms to improve indoor air quality: the FRESH study
Rosbach, J., Vonk, M., Duijm, F., Ginkel, J. T. V., Gehring, U., & Brunekreef, B. (2013) · Environmental Health · doi:10.1186/1476-069x-12-110 · Cited by 89
Shared Air: A Renewed Focus on Ventilation for the Prevention of Tuberculosis Transmission
Richardson, E. T., Morrow, C. D., Kalil, D. B., Bekker, L., & Wood, R. (2014) · PLoS ONE · doi:10.1371/journal.pone.0096334 · Cited by 83
“It should be recognized that the benefits of increased ventilation are not limited to prevention of TB transmission: decreased respiratory illness, fewer school absences, and improved cognitive function have been demonstrated in the literature [30–32].”
Li, Y., Yuan, Y., Li, C., Han, X., & Zhang, X. (2018) · Building and Environment · doi:10.1016/j.buildenv.2017.12.038 · Cited by 81
An integrative health framework for wellbeing in the built environment
Engineer, A., Gualano, R. J., Crocker, R. L., Smith, J. L., Maizes, V., Weil, A., & STERNBERG, E. M. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.108253 · Cited by 103
A CO 2 optical sensor based on self-assembled metal–organic framework nanoparticles
Chocarro-Ruiz, B., Pérez‐Carvajal, J., Avcı, C., Calvo-Lozano, O., Alonso, M. I., Maspoch, D., & Lechuga, L. M. (2018) · Journal of Materials Chemistry A · doi:10.1039/c8ta02767f · Cited by 79
Shriram, S., Ramamurthy, K., & Ramakrishnan, S. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.12.015 · Cited by 82
Creative and productive workplaces: a review
Clements-Croome, D. J. (2015) · Intelligent Buildings International · doi:10.1080/17508975.2015.1019698 · Cited by 98
Jung, H., Grady, M. L., Victoroff, T. M., & Miller, A. L. (2017) · Atmospheric Environment · doi:10.1016/j.atmosenv.2017.04.014 · Cited by 82
“Given research suggesting that CO2 concentrations below 2000 ppm can have a negative effect cognitive function (Allen et al., 2015; Kajtar et al., 2003, 2006; Maddalena et al., 2015; Satish et al., 2012), it may be desirable to set a lower target for CO2 concentration during real-world application of this concept.”
BackgroundInfluentialCarbon dioxide accumulation inside vehicles: The effect of ventilation and driving conditions
Hudda, N., & Fruin, S. A. (2017) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2017.08.105 · Cited by 78
Model predictive control of indoor microclimate: Existing building stock comfort improvement
Ryzhov, A., Ouerdane, H., Gryazina, E. N., Bischi, A., & Turitsyn, K. S. (2018) · Energy Conversion and Management · doi:10.1016/j.enconman.2018.10.046 · Cited by 77
“Note that CO2 concentration deserves particular attention: levels recorded in houses may reach values as high as 5000 ppm, which dramatically affects people’s behavior as recently shown in dedicated studies [5, 6]; in fact, even at moderate levels of concentrations, say 2500 ppm, routinely reached in classes and confe…”
BackgroundA review of encapsulated ionic liquids for CO2 capture
Solangi, N. H., Hussin, F., Anjum, A., Nizamuddin, S., Mazari, S. A., Mubarak, N. M., Aroua, M. K., Siddiqui, M. T. H., & Qureshi, S. S. (2023) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2023.121266 · Cited by 77
On the Development of Health-Based Ventilation Guidelines: Principles and Framework
Carrer, P., Fernandes, E. D. O., Santos, H., Hänninen, O., Kephalopoulos, S., & Wargocki, P. L. (2018) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph15071360 · Cited by 82
“Some studies have however shown that CO2 levels as low as 1000 ppm can produce negative effects on cognitive performance in the form of a reduced ability to make complex decisions [47,48].”
BackgroundMagaña, V. C., Scherz, W. D., Seepold, R., Madrid, N. M., Pañeda, X. G., & García, R. (2020) · Sensors · doi:10.3390/s20185274 · Cited by 82
“In [12], the researchers concluded that decision-making performance decreased when participants were exposed to CO2 concentrations between 1000 and 2500 ppm.”
BackgroundHou, F., Ma, J., Kwok, H. L., & Cheng, J. C. P. (2022) · Building and Environment · doi:10.1016/j.buildenv.2022.109576 · Cited by 75
Indoor environment in bedrooms in 79 Greenlandic households
Kotol, M., Rode, C., Clausen, G., & Nielsen, T. R. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.05.016 · Cited by 77
Indoor Air Quality in Brazilian Universities
Jurado, S. R., Bankoff, A. D. P., & Sanchez, A. (2014) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph110707081 · Cited by 73
Indoor Air Quality and Strategic Decision Making
Künn, S., Palacios, J., & Pestel, N. (2023) · Management Science · doi:10.1287/mnsc.2022.4643 · Cited by 78
“Indoor concentrations of CO 2 are a proxy for changes in the ventilation rates in the room, together with changes in the number and activity patterns of occupants, such as breathing patterns (e.g., Satish et al. 2012, Allen et al. 2016, Roth 2016).”
BackgroundMuscatiello, N. A., McCarthy, A., Kielb, C. L., Hsu, W.-H., Hwang, S., & Lin, S. (2014) · Indoor Air · doi:10.1111/ina.12136 · Cited by 80
Carbon dioxide increases with face masks but remains below short-term NIOSH limits
Rhee, M. S. M., Lindquist, C. D., Silvestrini, M. T., Chan, A. C. Y., Ong, J. J. Y., & Sharma, V. K. (2021) · BMC Infectious Diseases · doi:10.1186/s12879-021-06056-0 · Cited by 71
“Symptoms related to an increase in CO2 concentration are believed to start above the NIOSH 8-h threshold of 5000 ppm [2, 17].”
BackgroundZhang, X., Fan, L., Zhang, L., Zhao, Z., & Norbäck, D. (2014) · PLoS ONE · doi:10.1371/journal.pone.0112933 · Cited by 84
“One recent study has reported that at 1000 ppm CO2, compared to a CO2-level of 600 ppm, decision-making performance was reduced [34].”
BackgroundSensory evaluation and chemical analysis of exhaled and dermally emitted bioeffluents
Tsushima, S., Wargocki, P. L., & Tanabe, S. (2017) · Indoor Air · doi:10.1111/ina.12424 · Cited by 77
Metadata
- Authors
- Satish, U., Mendell, M. J., Shekhar, K., Hotchi, T., Sullivan, D., Streufert, S., & Fisk, W. J.
- Affiliations
- SUNY Upstate Medical University (US)
- Lawrence Berkeley National Laboratory (US)
- Corresponding author
- Mendell, Mark J.
- Venue
- Environmental Health Perspectives
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-09-20
- Volume
- 120
- Issue
- 12
- Pages
- 1671-1677
- ISSN
- 0091-6765 (ISSN-L)
- 1552-9924
- PMC
- PMC3548274
- OpenAlex
- W2089734242
- Cited by
- 1,064
- References
- 24
- Citations by year
- 2026: 105 · 2025: 119 · 2024: 103 · 2023: 108 · 2022: 92 · 2021: 123 · 2020: 94 · 2019: 80 · 2018: 63 · 2017: 47 · 2016: 44 · 2015: 34 · 2014: 33 · 2013: 16 · 2012: 1
- FWCI
- 18.60
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- public-domain
- creativecommons.org/licenses/by/4.0/ (vor, 1926 d)
- Locations
- Environmental Health Perspectives (publishedVersion, public-domain)
- Europe PMC (PubMed Central) (publishedVersion, public-domain)
- PubMed Central (publishedVersion, public-domain)
- PubMed (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
- Funders
- U.S. Environmental Protection Agency
- Syracuse University
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Air Quality and Health Impacts
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Keywords
- indoor carbon dioxide, decision performance, cognitive performance, indoor air quality, ventilation rate, health symptoms, perceived air quality, CO2 exposure, office buildings
- MeSH terms
- Adolescent, Adult, Air Pollutants, Analysis of Variance, Carbon Dioxide, Decision Making, Dose-Response Relationship, Drug, Environmental Exposure, Environmental Monitoring, Female, Humans, Male, Surveys and Questionnaires, Ventilation, Air Pollution, Indoor, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.