The DOI matches its Crossref record; 86 of the 86 references it cites were found in a registry or an index.
Ozone’s Impact on Public Health: Contributions from Indoor Exposures to Ozone and Products of Ozone-Initiated Chemistry
Open accessAbstract
OBJECTIVE: The associations between ozone concentrations measured outdoors and both morbidity and mortality may be partially due to indoor exposures to ozone and ozone-initiated oxidation products. In this article I examine the contributions of such indoor exposures to overall ozone-related health effects by extensive review of the literature as well as further analyses of published data. FINDINGS: Daily inhalation intakes of indoor ozone (micrograms per day) are estimated to be between 25 and 60% of total daily ozone intake. This is especially noteworthy in light of recent work indicating little, if any, threshold for ozone's impact on mortality. Additionally, the present study estimates that average daily indoor intakes of ozone oxidation products are roughly one-third to twice the indoor inhalation intake of ozone alone. Some of these oxidation products are known or suspected to adversely affect human health (e.g., formaldehyde, acrolein, hydroperoxides, fine and ultrafine particles). Indirect evidence supports connections between morbidity/mortality and exposures to indoor ozone and its oxidation products. For example, cities with stronger associations between outdoor ozone and mortality tend to have residences that are older and less likely to have central air conditioning, which implies greater transport of ozone from outdoors to indoors. CONCLUSIONS: Indoor exposures to ozone and its oxidation products can be reduced by filtering ozone from ventilation air and limiting the indoor use of products and materials whose emissions react with ozone. Such steps might be especially valuable in schools, hospitals, and childcare centers in regions that routinely experience elevated outdoor ozone concentrations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lung cancer, cardiopulmonary mortality, and long-term exposure to fine particulate air pollution
Pope III, C. A. (2002) · JAMA · doi:10.1001/jama.287.9.1132 · Cited by 8,447
Fine Particulate Air Pollution and Hospital Admission for Cardiovascular and Respiratory Diseases
Dominici, F., Peng, R. D., Bell, M. L., Pham, L., McDermott, A., Zeger, S. L., & Samet, J. M. (2006) · JAMA · doi:10.1001/jama.295.10.1127 · Cited by 2,634
Gas-phase tropospheric chemistry of biogenic volatile organic compounds: a review
Atkinson, R., & Arey, J. (2003) · Atmospheric Environment · doi:10.1016/s1352-2310(03)00391-1 · Cited by 1,385
Ozone and short-term mortality in 95 US urban communities, 1987–2000
Bell, M. L. (2004) · JAMA · doi:10.1001/jama.292.19.2372 · Cited by 1,202
Cleaning products and air fresheners: exposure to primary and secondary air pollutants
Nazaroff, W. W., & Weschler, C. J. (2004) · Atmospheric Environment · doi:10.1016/j.atmosenv.2004.02.040 · Cited by 846
Self-citationOzone in Indoor Environments: Concentration and Chemistry
WESCHLER, C. J. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004269.x · Cited by 758
Self-citationBell, M. L., Dominici, F., & Samet, J. M. (2005) · Epidemiology · doi:10.1097/01.ede.0000165817.40152.85 · Cited by 624
Concentrations of Volatile Organic Compounds in Indoor Air - A Review
Brown, S. K., Sim, M. R., Abramson, M. J., & Gray, C. N. (1994) · Indoor Air · doi:10.1111/j.1600-0668.1994.t01-2-00007.x · Cited by 559
Bell, M. L., Peng, R. D., & Dominici, F. (2006) · Environmental Health Perspectives · doi:10.1289/ehp.8816 · Cited by 481 · cited 2×
“Given that even low levels of ozone have been associated with increased risk of premature mortality (Bell et al. 2006), indoor intakes should not be ignored.”
BackgroundAssociation of low-level ozone and fine particles with respiratory symptoms in children with asthma
Gent, J. F. (2003) · JAMA · doi:10.1001/jama.290.14.1859 · Cited by 477
Acute Effects of Ozone on Mortality from the “Air Pollution and Health
Gryparis, A., Forsberg, B., Katsouyanni, K., Analitis, A., Touloumi, G., Schwartz, J., Samoli, E., Medina, S., Anderson, H. R., Niciu, E. M., et al. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200403-333oc · Cited by 449
Docherty, K. S., Wu, W., Lim, Y. B., & Ziemann, P. J. (2005) · Environmental Science & Technology · doi:10.1021/es050228s · Cited by 432
Associations Between Ozone and Daily Mortality: Analysis and Meta-Analysis
Ito, K., De Leon, S. F., & Lippmann, M. (2005) · Epidemiology · doi:10.1097/01.ede.0000165821.90114.7f · Cited by 384
Cogliano, V. J., Grosse, Y., Baan, R. A., Straif, K., Secretan, M. B., Ghissassi, F. E., & the Working Group for Volume 88 (2005) · Environmental Health Perspectives · doi:10.1289/ehp.7542 · Cited by 375
Characterization of Indoor Particle Sources Using Continuous Mass and Size Monitors
Long, C. M., Suh, H. H., & Koutrakis, P. (2000) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2000.10464154 · Cited by 364
Singer, B. C., Destaillats, H., Hodgson, A. T., & Nazaroff, W. W. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2005.00414.x · Cited by 324
Indoor ozone/terpene reactions as a source of indoor particles
Weschler, C. J., & Shields, H. C. (1999) · Atmospheric Environment · doi:10.1016/s1352-2310(99)00083-7 · Cited by 319
Self-citationOzone Exposure and Mortality: An Empiric Bayes Metaregression Analysis
Levy, J. I., Chemerynski, S. M., & Sarnat, J. A. (2005) · Epidemiology · doi:10.1097/01.ede.0000165820.08301.b3 · Cited by 302
Risk in cleaning: chemical and physical exposure
Wolkoff, P., Schneider, T., Kildesø, J., Degerth, R., Jaroszewski, M., & Schunk, H. (1998) · Science of The Total Environment · doi:10.1016/s0048-9697(98)00110-7 · Cited by 287
Destaillats, H., Lunden, M. M., Singer, B. C., Coleman, B. K., Hodgson, A. T., Weschler, C. J., & Nazaroff, W. W. (2006) · Environmental Science & Technology · doi:10.1021/es052198z · Cited by 284
Self-citationOzone and limonene in indoor air: a source of submicron particle exposure.
Wainman, T., Zhang, J., Weschler, C. J., & Lioy, P. J. (2000) · Environmental Health Perspectives · doi:10.1289/ehp.001081139 · Cited by 274
Self-citationMathematical modeling of chemically reactive pollutants in indoor air
Nazaroff, W. W., & Cass, G. R. (1986) · Environmental Science & Technology · doi:10.1021/es00151a012 · Cited by 259
Potential reactions among indoor pollutants
Weschler, C. J., & Shields, H. C. (1997) · Atmospheric Environment · doi:10.1016/s1352-2310(97)00219-7 · Cited by 257
Self-citationFormation of Strong Airway Irritants in Terpene/Ozone Mixtures
WOLKOFF, P., CLAUSEN, P. A., WILKINS, C. K., & NIELSEN, G. D. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010002082.x · Cited by 253
McDonnell, W. F., Abbey, D. E., Nishino, N., & Lebowitz, M. D. (1999) · Environmental Research · doi:10.1006/enrs.1998.3894 · Cited by 249
HODGSON, A. T., RUDD, A. F., BEAL, D., & CHANDRA, S. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010003178.x · Cited by 240
Indoor chemistry: ozone, volatile organic compounds, and carpets
Weschler, C. J., Hodgson, A. T., & Wooley, J. D. (1992) · Environmental Science & Technology · doi:10.1021/es00036a006 · Cited by 233
Self-citationSarnat, J. A., Brown, K. W., Schwartz, J., Coull, B. A., & Koutrakis, P. (2005) · Epidemiology · doi:10.1097/01.ede.0000155505.04775.33 · Cited by 223
Hazardous air pollutants and asthma.
Leikauf, G. D. (2002) · Environmental Health Perspectives · doi:10.1289/ehp.02110s4505 · Cited by 217
Volatile Organic Compounds Sources, Measurements, Emissions, and the Impact on Indoor Air Quality
Wolkoff, P. (1995) · Indoor Air · doi:10.1111/j.1600-0668.1995.tb00017.x · Cited by 210
Production of the Hydroxyl Radical in Indoor Air
Weschler, C. J., & Shields, H. C. (1996) · Environmental Science & Technology · doi:10.1021/es960032f · Cited by 208
Self-citationEffect of air pollution on daily mortality in Hong Kong.
Wong, C. M., Ma, S., Hedley, A. J., & Lam, T. H. (2001) · Environmental Health Perspectives · doi:10.1289/ehp.01109335 · Cited by 206
Variations of formaldehyde and VOC levels during 3 years in new and older homes
Park, J. S., & Ikeda, K. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2005.00408.x · Cited by 201
Thornberry, T., & Abbatt, J. P. D. (2004) · Physical Chemistry Chemical Physics · doi:10.1039/b310149e · Cited by 193
Fan, Z., Lioy, P., Weschler, C., Fiedler, N., Kipen, H., & Zhang, J. (2003) · Environmental Science & Technology · doi:10.1021/es026231i · Cited by 188
Self-citationOzone Interactions with Carpet: Secondary Emissions of Aldehydes
Morrison, G. C., & Nazaroff, W. W. (2002) · Environmental Science & Technology · doi:10.1021/es0113089 · Cited by 185
Selected oxidized fragrance terpenes are common contact allergens
Matura, M., Sköld, M., Börje, A., Andersen, K. E., Bruze, M., Frosch, P., Goossens, A., Johansen, J. D., Svedman, C., White, I. R., et al. (2005) · Contact Dermatitis · doi:10.1111/j.0105-1873.2005.00605.x · Cited by 182
Ozonolysis at vegetation surfaces
Fruekilde, P., Hjorth, J., Jensen, N. R., Kotzias, D., & Larsen, B. (1998) · Atmospheric Environment · doi:10.1016/s1352-2310(97)00485-8 · Cited by 178
Contact allergy to oxidized d‐limonene among dermatitis patients
Karlberg, A., & Dooms‐Goossens, A. (1997) · Contact Dermatitis · doi:10.1111/j.1600-0536.1997.tb00270.x · Cited by 168
Hydroxyl radicals in indoor environments
Sarwar, G., Corsi, R., Kimura, Y., Allen, D., & Weschler, C. J. (2002) · Atmospheric Environment · doi:10.1016/s1352-2310(02)00278-9 · Cited by 167
Self-citationHealth-Related Benefits of Attaining the 8-Hr Ozone Standard
Hubbell, B. J., Hallberg, A., McCubbin, D. R., & Post, E. (2005) · Environmental Health Perspectives · doi:10.1289/ehp.7186 · Cited by 166
Ozone and daily mortality in Shanghai, China
Zhang, Y., Huang, W., London, S. J., Song, G., Chen, G., Jiang, L., Zhao, N., Chen, B., & Kan, H. (2006) · Environmental Health Perspectives · doi:10.1289/ehp.9014 · Cited by 163
Using Sulfur as a Tracer of Outdoor Fine Particulate Matter
Sarnat, J. A., Long, C. M., Koutrakis, P., Coull, B. A., Schwartz, J., & Suh, H. H. (2002) · Environmental Science & Technology · doi:10.1021/es025796b · Cited by 163
Products of Ozone-Initiated Chemistry in a Simulated Aircraft Environment
Wisthaler, A., Tamás, G., Wyon, D. P., Strøm-Tejsen, P., Space, D., Beauchamp, J., Hansel, A., Märk, T. D., & Weschler, C. J. (2005) · Environmental Science & Technology · doi:10.1021/es047992j · Cited by 162
Self-citationWeschler, C. J., & Shields, H. C. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010002092.x · Cited by 149
Self-citationFiedler, N. L., Laumbach, R. J., Kelly‐McNeil, K., Lioy, P. J., Fan, Z. T., Zhang, J. J., Ottenweller, J. E., Ohman‐Strickland, P., & Kipen, H. M. (2005) · Environmental Health Perspectives · doi:10.1289/ehp.8132 · Cited by 148
Sköld, M., Börje, A., Matura, M., & Karlberg, A. (2002) · Contact Dermatitis · doi:10.1034/j.1600-0536.2002.460504.x · Cited by 147
Weisel, C. P., Zhang, J. J., Turpin, B. J., Morandi, M. T., Colome, S. D., Stock, T. H., Spektor, D. M., Korn, L. R., Winer, A. M., Kwon, J., et al. (2005) · PubMed · Cited by 145
Grøntoft, T., & Raychaudhuri, M. R. (2003) · Atmospheric Environment · doi:10.1016/j.atmosenv.2003.10.010 · Cited by 145
Indoor Fine Particles: The Role of Terpene Emissions from Consumer Products
Sarwar, G., Olson, D. A., Corsi, R. L., & Weschler, C. J. (2004) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2004.10470910 · Cited by 141
Self-citationEffect of Ozone on Nicotine Desorption from Model Surfaces: Evidence for Heterogeneous Chemistry
Destaillats, H., Singer, B. C., Lee, S. K., & Gundel, L. A. (2006) · Environmental Science & Technology · doi:10.1021/es050914r · Cited by 134
The effects of evaporating essential oils on indoor air quality
Su, H.-J. J., Chao, C.-J., Chang, H., & Wu, P.-C. (2006) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.09.044 · Cited by 134
Chemical and biological evaluation of a reaction mixture of R-(+)-limonene/ozone
Clausen, P. A., Wilkins, C. K., Wolkoff, P., & Nielsen, G. D. (2001) · Environment International · doi:10.1016/s0160-4120(01)00035-6 · Cited by 128
Sarwar, G., Corsi, R. L., Allen, D. T., & Weschler, C. J. (2003) · Atmospheric Environment · doi:10.1016/s1352-2310(02)01013-0 · Cited by 119
Self-citationRohr, A., Weschler, C. J., Koutrakis, P., & Spengler, J. D. (2003) · Aerosol Science and Technology · doi:10.1080/02786820300892 · Cited by 118
Self-citationOzone-Initiated Secondary Emission Rates of Aldehydes from Indoor Surfaces in Four Homes
Wang, H., & Morrison, G. (2006) · Environmental Science & Technology · doi:10.1021/es060080s · Cited by 118
Rohr, A., Wilkins, C. K., Clausen, P. A., et al. (2002) · Inhalation Toxicology · doi:10.1080/08958370290084575 · Cited by 116
Wallace, L. A., Williams, R. W., Rea, A. W., & Croghan, C. W. (2005) · Atmospheric Environment · doi:10.1016/j.atmosenv.2005.08.042 · Cited by 113
Hodgson, A. T., Wooley, J. D., & Daisey, J. M. (1993) · Air & Waste · doi:10.1080/1073161x.1993.10467136 · Cited by 103
Taucher, J., Hansel, A., Jordan, A., Fall, R., Futrell, J. H., & Lindinger, W. (1997) · Rapid Communications in Mass Spectrometry · Cited by 102
Ozone Reactive Chemistry on Interior Latex Paint
Reiss, R., Ryan, P. B., Koutrakis, P., & Tibbetts, S. J. (1995) · Environmental Science & Technology · doi:10.1021/es00008a007 · Cited by 100
Personal reactive clouds: Introducing the concept of near-head chemistry
Corsi, R. L., Siegel, J. A., Karamalegos, A., Simon, H., & Morrison, G. (2007) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.07.054 · Cited by 100
Weschler, C. J., Brauer, M. D., & Koutrakis, P. (1992) · Environmental Science & Technology · doi:10.1021/es00025a022 · Cited by 99
Self-citationFull-Scale Chamber Investigation and Simulation of Air Freshener Emissions in the Presence of Ozone
Liu, X., Mason, M., Krebs, K. A., & Sparks, L. (2004) · Environmental Science & Technology · doi:10.1021/es030544b · Cited by 95
Ozone Decay Rates in Residences
Lee, K., Vallarino, J., Dumyahn, T. S., Özkaynak, H., & Spengler, J. D. (1999) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.1999.10463913 · Cited by 95
Reiss, R., Ryan, P. B., Tibbetts, S. J., & Koutrakis, P. (1995) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.1995.10467411 · Cited by 95
Klen�, J., & Wolkoff, P. (2004) · International Archives of Occupational and Environmental Health · doi:10.1007/s00420-003-0502-1 · Cited by 92
Patch testing with oxidized R‐(+)‐limonene and its hydroperoxide fraction
Matura, M., Goossens, A. E., Bordalo, O., García‐Bravo, B., Magnusson, K., Wrangsjö, K., & Karlberg, A. (2003) · Contact Dermatitis · doi:10.1111/j.0105-1873.2003.00135.x · Cited by 91
Wilkins, C. K., Clausen, P. A., Wolkoff, P., et al. (2001) · Environmental Health Perspectives · doi:10.1289/ehp.01109937 · Cited by 91
The effect on human eye blink frequency of exposure to limonene oxidation products and methacrolein
Nøjgaard, J. K., Christensen, K. B., & Wolkoff, P. (2005) · Toxicology Letters · doi:10.1016/j.toxlet.2004.11.013 · Cited by 89
New Directions: Ozone-initiated reaction products indoors may be more harmful than ozone itself
Weschler, C. J. (2004) · Atmospheric Environment · doi:10.1016/j.atmosenv.2004.08.001 · Cited by 87
Self-citationFormation of strong airway irritants in a model mixture of (+)-α-pinene/ozone
Wolkoff, P. (1999) · Atmospheric Environment · doi:10.1016/s1352-2310(98)00292-1 · Cited by 86
Ozone in Residential Air: Concentrations, I/O Ratios, Indoor Chemistry, and Exposures
Zhang, J. J., & Lioy, P. J. (1994) · Indoor Air · doi:10.1111/j.1600-0668.1994.t01-2-00004.x · Cited by 82
Fine organic particulate matter dominates indoor-generated PM2.5 in RIOPA homes
Polidori, A., Turpin, B. J., Meng, Q. Y., Lee, J., Weisel, C. P., Morandi, M. T., Colome, S. D., Stock, T. H., Winer, A., Zhang, J., et al. (2006) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jes.7500476 · Cited by 76
Peroxyacetyl nitrate: review of toxicity
Vyskočil, A., Viau, C., & Lamy, S. (1998) · Human & Experimental Toxicology · doi:10.1177/096032719801700403 · Cited by 68
Indoor Hydrogen Peroxide Derived from Ozone/ d -Limonene Reactions
Li, T.-H., Turpin, B. J., Shields, H. C., & Weschler, C. J. (2002) · Environmental Science & Technology · doi:10.1021/es015842s · Cited by 63
Self-citationModeling Ozone Levels in and around Southern California Homes
Avol, E. L., Navidi, W. C., & Colome, S. D. (1998) · Environmental Science & Technology · doi:10.1021/es970351m · Cited by 61
Short-term air pollution exposures and responses in Los Angeles area schoolchildren.
Linn, W. S., Shamoo, D. A., Anderson, K. R., Peng, R.-C., Avol, E., Hackney, J. D., & Gong, H. (1996) · PubMed · Cited by 59
Use of Personal Measurements for Ozone Exposure Assessment: A Pilot Study
Liu, L. J., Koutrakis, P., Suh, H. H., Mulik, J. D., & Burton, R. M. (1993) · Environmental Health Perspectives · doi:10.1289/ehp.93101318 · Cited by 50
Ozone air pollution and daily mortality in Genoa, Italy between 1993 and 1996
Parodi, S., Vercelli, M., Garrone, E., Fontana, V., & Izzotti, A. (2005) · Public Health · doi:10.1016/j.puhe.2004.10.007 · Cited by 47
Personal and Fixed-Site Ozone Measurements with a Passive Sampler
Brauer, M. D., & Brook, J. R. (1995) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.1995.10467384 · Cited by 42
Indoor air chemistry and physics
Nazaroff, W. W., Weschler, C. J., & Corsi, R. L. (2003) · Atmospheric Environment · doi:10.1016/j.atmosenv.2003.09.021 · Cited by 40
Self-citationFormation of oxidation products in a ventilation system
Fick, J. B., Nilsson, C., & Andersson, B. A. V. (2004) · Atmospheric Environment · doi:10.1016/j.atmosenv.2004.08.020 · Cited by 40
Evaluation of Indoor Ozone Concentration and Predictors of Indoor-Outdoor Ratio in Mexico City
Romieu, I., Lugo, M. C., Colome, S., García, A. M., Hernández‐Ávila, M., Geyh, A., Ruiz‐Velasco, S., & Rendón, E. P. (1998) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.1998.10463684 · Cited by 37
Nørgaard, A. W., Nøjgaard, J. K., Larsen, K., Sporring, S., Wilkins, C. K., Clausen, P. A., & Wolkoff, P. (2006) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.02.007 · Cited by 32
Indoor air chemistry: cleaning agents, ozone and toxic air contaminants.
Nazaroff, W. W. (2006) · Cited by 29
Cited by
Al horr, Y., Arif, M., Katafygiotou, M., Mazroei, A., Kaushik, A., & Elsarrag, E. (2016) · International Journal of Sustainable Built Environment · doi:10.1016/j.ijsbe.2016.03.006 · Cited by 817
Ventilation rates and health: Multidisciplinary review of the scientific literature
Sundell, J., Levin, H., Nazaroff, W. W., Cain, W. S., Fisk, W. J., Grimsrud, D. T., Gyntelberg, F., Li, Y., Persily, A. K., Pickering, A. C., et al. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2010.00703.x · Cited by 740
Self-citationChanges in indoor pollutants since the 1950s
Weschler, C. J. (2009) · Atmospheric Environment · doi:10.1016/j.atmosenv.2008.09.044 · Cited by 669
Self-citationPöschl, U., & Shiraiwa, M. (2015) · Chemical Reviews · doi:10.1021/cr500487s · Cited by 657
Indoor air pollutants in office environments: Assessment of comfort, health, and performance
Wolkoff, P. (2013) · International Journal of Hygiene and Environmental Health · doi:10.1016/j.ijheh.2012.08.001 · Cited by 342
Metadata
- Authors
- Weschler, C. J.
- Venue
- Environmental Health Perspectives
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-10
- Volume
- 114
- Issue
- 10
- Pages
- 1489-1496
- ISSN
- 0091-6765 (ISSN-L)
- 1552-9924
- OpenAlex
- W2088435402
- Cited by
- 481
- References
- 86
- FWCI
- 12.84
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.