Hands-on robotic unicompartmental knee replacement: A PROSPECTIVE, RANDOMISED CONTROLLED STUDY OF THE ACROBOT SYSTEM
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
We performed a prospective, randomised controlled trial of unicompartmental knee arthroplasty comparing the performance of the Acrobot system with conventional surgery. A total of 27 patients (28 knees) awaiting unicompartmental knee arthroplasty were randomly allocated to have the operation performed conventionally or with the assistance of the Acrobot. The primary outcome measurement was the angle of tibiofemoral alignment in the coronal plane, measured by CT. Other secondary parameters were evaluated and are reported. All of the Acrobot group had tibiofemoral alignment in the coronal plane within 2° of the planned position, while only 40% of the conventional group achieved this level of accuracy. While the operations took longer, no adverse effects were noted, and there was a trend towards improvement in performance with increasing accuracy based on the Western Ontario and McMaster Universities Osteoarthritis Index and American Knee Society scores at six weeks and three months. The Acrobot device allows the surgeon to reproduce a pre-operative plan more reliably than is possible using conventional techniques which may have clinical advantages.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rationale, of The Knee Society Clinical Rating System
INSALL, J. N., DORR, L. D., SCOTT, R. D., & NORMAN, W. (1989) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198911000-00004 · Cited by 4,793
The Oxford medial unicompartmental arthroplasty: A TEN-YEAR SURVIVAL STUDY
Murray, D. W., Goodfellow, J. W., & O’Connor, J. J. (1998) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.80b6.0800983 · Cited by 770
Bäthis, H., Perlick, L., Tingart, M., Lüring, C., Zurakowski, D., & Grifka, J. (2004) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.86b5.14927 · Cited by 667
Bellamy, N. (1988) · Medical Entomology and Zoology · Cited by 552
Primary and Revision Total Hip Replacement Using the Robodoc?? System
Bargar, W. L., Bauer, A., & B??rner, M. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199809000-00011 · Cited by 419
The Swedish knee arthroplasty register: A nation-wide study of 30,003 knees 1976-1992
Knutson, K., Lewold, S., Robertsson, O., & Lidgren, L. (1994) · Acta Orthopaedica · doi:10.3109/17453679408995475 · Cited by 306
Navigation Improves Accuracy of Rotational Alignment in Total Knee Arthroplasty
St??ckl, B., Nogler, M., Rosiek, R., Fischer, M., Krismer, M., & Kessler, O. (2004) · Clinical Orthopaedics and Related Research · doi:10.1097/01.blo.0000136835.40566.d9 · Cited by 286
Technique and first clinical results of robot-assisted total knee replacement
Siebert, W., Mai, S., Kober, R., & Heeckt, P. F. (2002) · The Knee · doi:10.1016/s0968-0160(02)00015-7 · Cited by 281
The First Clinical Application of a “Hands-On” Robotic Knee Surgery System
Jakopec, M., Harris, S., y Baena, F. R., Gomes, P., Cobb, J. P., & Davies, B. (2001) · Computer Aided Surgery · doi:10.1002/igs.10023 · Cited by 225
Self-citationKENNEDY, W. R., & WHITE, R. P. (1987) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198708000-00037 · Cited by 206
Jenny, J., & Boéri, C. (2001) · Computer Aided Surgery · doi:10.3109/10929080109146086 · Cited by 159
The reliability of the American Knee Society Score
Liow, R., Walker, K. A., Wajid, M. A., Bedi, G., & Lennox, C. M. E. (2000) · Acta Orthopaedica Scandinavica · doi:10.1080/000164700317362244 · Cited by 124
Excessive heat generation during cutting of cement in the Robodoc hip-revision procedure
Nogler, M., Krismer, M., Haid, C., Ogon, M., Bach, C. M., & Wimmer, C. (2001) · Acta Orthopaedica Scandinavica · doi:10.1080/000164701317269012 · Cited by 31
Cited by
A history of robots: from science fiction to surgical robotics
Hockstein, N. G., Gourin, C. G., Faust, R. A., & Terris, D. J. (2007) · Journal of Robotic Surgery · doi:10.1007/s11701-007-0021-2 · Cited by 271
Robotic Arm-assisted UKA Improves Tibial Component Alignment: A Pilot Study
Lonner, J. H., John, T. K., & Conditt, M. A. (2010) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-009-0977-5 · Cited by 215
van der List, J. P., Chawla, H., Joskowicz, L., & Pearle, A. D. (2016) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-016-4305-9 · Cited by 200
“als (RCTs) [27, 65, 93, 113, 114] have shown that robotic-”
Surgical robotics: Reviewing the past, analysing the present, imagining the future
Gomes, P. (2011) · Robotics and Computer-Integrated Manufacturing · doi:10.1016/j.rcim.2010.06.009 · Cited by 200
Self-citationMarchand, R., Sodhi, N., Khlopas, A., Sultan, A., Harwin, S., Malkani, A., & Mont, M. (2017) · The Journal of Knee Surgery · doi:10.1055/s-0037-1607450 · Cited by 195
Metadata
- Authors
- Cobb, J., Henckel, J., Gomes, P., Harris, S., Jakopec, M., Rodriguez, F., Barrett, A., & Davies, B.
- Venue
- The Journal of Bone and Joint Surgery. British volume
- Published
- 2006-02
- Volume
- 88-B
- Issue
- 2
- Pages
- 188-197
- ISSN
- 0301-620X (ISSN-L)
- 2044-5377
- OpenAlex
- W2615266555
- Cited by
- 333
- References
- 13
- FWCI
- 9.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.