The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
In vivo local determination of tissue optical properties: applications to human brain
Open accessAbstract
Local and superficial near-infrared (NIR) optical-property characterization of turbid biological tissues can be achieved by measurement of spatially resolved diffuse reflectance at small source-detector separations (<1.4 mm). However, in these conditions the inverse problem, i.e., calculation of localized absorption and the reduced scattering coefficients, is necessarily sensitive to the scattering phase function. This effect can be minimized if a new parameter of the phase function gamma, which depends on the first and the second moments of the phase function, is known. If gamma is unknown, an estimation of this parameter can be obtained by the measurement, but the uncertainty of the absorption coefficient is increased. A spatially resolved reflectance probe employing multiple detector fibers (0.3-1.4 mm from the source) is described. Monte Carlo simulations are used to determine gamma, the reduced scattering and absorption coefficients from reflectance data. Probe performance is assessed by measurements on phantoms, the optical properties of which were measured by other techniques [frequency domain photon migration (FDPM) and spatially resolved transmittance]. Our results show that changes in the absorption coefficient, the reduced scattering coefficient, and gamma can be measured to within +/-0.005 mm(-1), +/-0.05 mm(-1), and +/-0.2, respectively. In vivo measurements performed intraoperatively on a human skull and brain are reported for four NIR wavelengths (674, 811, 849, 956 nm) when the spatially resolved probe and FDPM are used. The spatially resolved probe shows optimum measurement sensitivity in the measurement volume immediately beneath the probe (typically 1 mm(3) in tissues), whereas FDPM typically samples larger regions of tissues. Optical-property values for human skull, white matter, scar tissue, optic nerve, and tumors are reported that show distinct absorption and scattering differences between structures and a dependence on the phase-function parameter gamma.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Absorption and Scattering of Light by Small Particles
Bohren, C. F., & Huffman, D. R. (1998) · doi:10.1002/9783527618156 · Cited by 18,474
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Farrell, T. J., Patterson, M. S., & Wilson, B. (1992) · Medical Physics · doi:10.1118/1.596777 · Cited by 1,378
Light scattering in lntralipid-10% in the wavelength range of 400–1100 nm
van Staveren, H. J., Moes, C. J. M., van Marie, J., Prahl, S. A., & van Gemert, M. J. C. (1991) · Applied Optics · doi:10.1364/ao.30.004507 · Cited by 1,106
Refractive index of some mammalian tissues using a fiber optic cladding method
Bolin, F. P., Preuss, L. E., Taylor, R. C., & Ference, R. J. (1989) · Applied Optics · doi:10.1364/ao.28.002297 · Cited by 522
Kienle, A., Lilge, L., Patterson, M. S., Hibst, R., Steiner, R., & Wilson, B. C. (1996) · Applied Optics · doi:10.1364/ao.35.002304 · Cited by 495
Measurement of the optical properties of the skull in the wavelength range 650-950 nm
Firbank, M., Hiraoka, M., Essenpreis, M., & Delpy, D. T. (1993) · Physics in Medicine and Biology · doi:10.1088/0031-9155/38/4/002 · Cited by 305
Tromberg, B. J., Coquoz, O., Fishkin, J. B., Pham, T., Anderson, E. R., Butler, J., Cahn, M., Gross, J. D., Venugopalan, V., & Pham, D. (1997) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1997.0047 · Cited by 267
Self-citationFantini, S., Franceschini, M. A., Fishkin, J. B., Barbieri, B., & Gratton, E. (1994) · Applied Optics · doi:10.1364/ao.33.005204 · Cited by 259
Fishkin, J. B., Coquoz, O., Anderson, E. R., Brenner, M., & Tromberg, B. J. (1997) · Applied Optics · doi:10.1364/ao.36.000010 · Cited by 259
Self-citationSpectroscopic diagnosis of bladder cancer with elastic light scattering
Mourant, J. R., Bigio, I. J., Boyer, J., Conn, R. L., Johnson, T., & Shimada, T. (1995) · Lasers in Surgery and Medicine · doi:10.1002/lsm.1900170403 · Cited by 250
Extinction and absorption coefficients and scattering phase functions of human tissues in vitro
Marchesini, R., Bertoni, A., Andreola, S., Melloni, E., & Sichirollo, A. E. (1989) · Applied Optics · doi:10.1364/ao.28.002318 · Cited by 225
Flock, S. T., Wilson, B. C., & Patterson, M. S. (1987) · Medical Physics · doi:10.1118/1.596010 · Cited by 212
Optical properties of human dermis in vitro and in vivo
Graaff, R., Dassel, A. C. M., Koelink, M. H., de Mul, F. F. M., Aarnoudse, J. G., & Zijlstra, W. G. (1993) · Applied Optics · doi:10.1364/ao.32.000435 · Cited by 177
Time-gated transillumination of biological tissues and tissuelike phantoms
Mitić, G., Kölzer, J., Otto, J., Plies, E., Sölkner, G., & Zinth, W. (1994) · Applied Optics · doi:10.1364/ao.33.006699 · Cited by 133
Statistics of Penetration Depth of Photons Re-emitted from Irradiated Tissue
Weiss, G. H., Nossal, R., & Bonner, R. F. (1989) · Journal of Modern Optics · doi:10.1080/09500348914550381 · Cited by 113
Clinical determination of tissue optical properties by endoscopic spatially resolved reflectometry
Bays, R., Wagnières, G., Robert, D., Braichotte, D. R., Savary, J., Monnier, P., & van den Bergh, H. (1996) · Applied Optics · doi:10.1364/ao.35.001756 · Cited by 89
Optimal probe geometry for near-infrared spectroscopy of biological tissue
Kumar, G., & Schmitt, J. M. (1997) · Applied Optics · doi:10.1364/ao.36.002286 · Cited by 83
Bevilacqua, F. P., Marquet, P. P., Depeursinge, C. D., & de Haller, E. B. (1995) · Optical Engineering · doi:10.1117/12.204799 · Cited by 46
Self-citationMarquet, P. P., Bevilacqua, F. P., Depeursinge, C. D., & de Haller, E. B. (1995) · Optical Engineering · doi:10.1117/12.204798 · Cited by 44
Self-citation
Cited by
Optical properties of biological tissues: A review
Jacques, S. L. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/11/r37 · Cited by 4,008
Bashkatov, A. N., Genina, E. A., Kochubey, V. I., & Tuchin, V. V. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/15/004 · Cited by 1,720
Aravanis, A. M., Wang, L.-P., Zhang, F., Meltzer, L. A., Mogri, M. Z., Schneider, M. B., & Deisseroth, K. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/3/s02 · Cited by 970
OPTICAL PROPERTIES OF SKIN, SUBCUTANEOUS, AND MUSCLE TISSUES: A REVIEW
BASHKATOV, A. N., GENINA, E. A., & TUCHIN, V. V. (2011) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545811001319 · Cited by 761
Boas, D. A., Dale, A. M., & Franceschini, M. A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.011 · Cited by 721
Metadata
- Authors
- Bevilacqua, F., Piguet, D., Marquet, P., Gross, J. D., Tromberg, B. J., & Depeursinge, C.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1999-08-01
- Volume
- 38
- Issue
- 22
- Pages
- 4939
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2074531748
- Cited by
- 456
- References
- 20
- FWCI
- 11.85
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.